| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAdmitted-Finance | ₹14.4 L | L1 | Admitted-Finance |
| 2 | L2₹14.9 LAdmitted-Finance | ₹14.9 L | L2 | Admitted-Finance |
| 3 | L3₹15.6 LAdmitted-Finance | ₹15.6 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S R P ENTERPRISES L2 | SIDDHI ENTERPRISES L3 | P.S. ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Safe carriage, loading and unloading of following material from ESC Daliganj Lucknow in work site J.E. dump store | ||||||
| 1.01 | PCC Pole 8.5/9 Mtr long. | 25 | Nos | 475 ₹11,875 | 495 ₹12,375 | 450 ₹11,250 |
| 1.02 | S.T.P. Pole 9/11 Mtr. Long | 20 | Nos | 525 ₹10,500 | 545 ₹10,900 | 500 ₹10,000 |
| 1.03 | Carriage of ABC 3X95+3X120+1X70+1X16 | 2,000 | Mtr | 4 ₹8,000 | 5 ₹10,000 | 3 ₹6,000 |
| 2.00 | Fabrication and erection of missing/damaged wire mesh fencing 02 Mtr. Height with a gate and with retaining grouting of Fabrication M.S. Angle 65x65x6 mm support (05 Nos. in a Sub- Station). Plinthing of fencing/support with all material as per specification/drawing complete in all respect. | 50 | Rmt | 2,550 ₹1.3 L | 2,625 ₹1.3 L | 2,400 ₹1.2 L |
| 3.00 | Construction of Damaged part of masonry transformer Plinth of size as per required at site to maintain the height of 1.5M with brick cement coarse sand and brick ballast, filling of sand in the hallow space. Plastering of surface in ratio 1:4:5 and top of the plinth 4 thinkness concealing. (All material, Labour And T&P will be provided by the contractor | 10 | Cub. Mtr. | 12,100 ₹1.2 L | 12,900 ₹1.3 L | 10,000 ₹1 L |
| 4.00 | Repairing of damage/Rusted Steel Tubular Pole by digging of pit up to2 for proper position, Putting 3 Nos. Angle From of size 35x35x6 mm, 3 Long properly welding on 3 circle with pole than Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast, (All material, labour and T&P will be provided by the Contractor) | 25 | Nos | 3,800 ₹95,000 | 4,050 ₹1.0 L | 3,600 ₹90,000 |
| 5.00 | Construction of masonry type transformer plinth of size 2x2x1.5 M with brick, Cement, coarse sand , sand & brick ballast, filling of sand in the hallow space plastering outer surface in ratio 1:4;6 top of the plinth 4 thickness grouting of 2 nos. MS Channel of size 100x50x2000mm on the top of the plinth for placement of transformer (All the Material will be arranged by the contractor at his own cost) | 5 | Nos | 26,900 ₹1.3 L | 27,800 ₹1.4 L | 26,000 ₹1.3 L |
| 6.00 | Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor. | 12 | No. | 13,900 ₹1.7 L | 14,250 ₹1.7 L | 13,500 ₹1.6 L |
| 7.00 | Stringing,Sagging,winding and jumpering of LT line with AB Cable (3X95+3X120+1X70+1X16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook, suspension clamp and dead end clamp arranged by contractor .) | 2,000 | Mtr | 35 ₹70,000 | 37 ₹74,000 | 32 ₹64,000 |
Tender Value
₹14.0 L
EMD Value
₹14,500
Closing Date
24 Jan 2026, 12:00 pmClosed
SE-Technical
Office of the SE-Technical, Central Zone, Lucknow
52/SE(T)/LCZ/2025-26
2026_MVVNL_1107052_1
52/SE(T)/LCZ/2025-26
Open Tender
Electrical Works
365 days
Executive Engineer- 11 KV and LT Rajbhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Central bank of India
₹14,500
19 Feb 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
24 Jan 2026
19 Jan 2026
Safe carriage, loading and unloading of following material from ESC Daliganj Lucknow in work site J.E. dump store
PCC Pole 8.5/9 Mtr long.
S.T.P. Pole 9/11 Mtr. Long
Carriage of ABC 3X95+3X120+1X70+1X16
Fabrication and erection of missing/damaged wire mesh fencing 02 Mtr. Height with a gate and with retaining grouting of Fabrication M.S. Angle 65x65x6 mm support (05 Nos. in a Sub- Station). Plinthing of fencing/support with all material as per specification/drawing complete in all respect.
Construction of Damaged part of masonry transformer Plinth of size as per required at site to maintain the height of 1.5M with brick cement coarse sand and brick ballast, filling of sand in the hallow space. Plastering of surface in ratio 1:4:5 and top of the plinth 4 thinkness concealing. (All material, Labour And T&P will be provided by the contractor
Repairing of damage/Rusted Steel Tubular Pole by digging of pit up to2 for proper position, Putting 3 Nos. Angle From of size 35x35x6 mm, 3 Long properly welding on 3 circle with pole than Grouting and Plinthing 300 mm Above level with cement concrete and sand and bricks ballast, (All material, labour and T&P will be provided by the Contractor)
Construction of masonry type transformer plinth of size 2x2x1.5 M with brick, Cement, coarse sand , sand & brick ballast, filling of sand in the hallow space plastering outer surface in ratio 1:4;6 top of the plinth 4 thickness grouting of 2 nos. MS Channel of size 100x50x2000mm on the top of the plinth for placement of transformer (All the Material will be arranged by the contractor at his own cost)
Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor.
Stringing,Sagging,winding and jumpering of LT line with AB Cable (3X95+3X120+1X70+1X16) conductor as per RESSPO Norms.(AB Cable provided by deptt and balance material like holding clamp,eye hook, suspension clamp and dead end clamp arranged by contractor .)
Supply Of Fixing of Henley type taleless fuse unit on LT distribution pilled box with Clamping of lug required size of side in LT PVC cable
500Amp / 600 Volts
300 Amp / 650 Volts
Re sagging of L.T, O/H, ABC Line, opening of ABC at service point from distribution box and opening of Consumer service cable after Re-sagging of ABC Re Connection of Consumer Service cable on ST Pole/PCC. (All the material will be arranged by the Contractor)
Fixing of Cu L Piece of size 300x65x6 mm 400/250 KVA L/T Bushing Rod for proper Connection of LT cable. (All the material will be arranged by the contractor)
Re sagging of L.T/H.T. line along with spare parts for various spans
Straightening of PCC pole with the help of ropes & chain pulley and required.
Straightening of ST pole with the help of ropes & chain pulley and required.
Replacement of broken /damaged PCC Pole (As per RESPO Norms)
Installation of D.O. arrangement including mounting of clamps with nuts & bolt, 11 KV Pin insulator with pin (All material will be provided by the contractor)
Proper dressing of LT and 11 KV cable of 11/0.4 S/S with fixing accessories
Cleaning of 11/0.4 KV S/s removed of garbage dump and stacking it out side the fencing area
Checking of oil in Transformer
Replacement Of LT Cable lead wherever (Required Material provided by Deppt.)
Replacement of burnt jumpers of LT Line.
Replacement of burnt jumpers of HT Line.
Replacement of Disc insulator & insulator in 11 KV Line
Attending Breakdown of 11 Kv Feeder (By opening & Closing of cable at different exposures.)
Providing and fixing of guarding angle on existing 11 KV support with clamp nut bolts.
Supply & Replacement of damaged LT Cable box 3.5x240 Sqmm/3.5x400 Sqmm
Tightening of Bus bar of LT Compartment
Lug punching with replacement of damaged Lugs with nut & bolt in LT 11/0.4 KV 400 KVA T/F.
Lug punching with replacement of damaged Lugs with nut & bolt in LT 11/0.4 KV 250 KVA T/F.
All taxes as applicable shall be paid time to time extra
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_2042738.xls
BOQ • 0.25 MB
Doc52.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid