Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹84.3 L
Closing Date
31 Jul 2026, 4:00 pm5d left
Gruop A- DHDT Unit_Electrical Drive Package
Gruop A- DHDT Unit _ Mandatory Spares _List as per MR
Gruop A- DHDT Unit_ Site Training
Gruop A- DHDT Unit _ Site Supervision of Erection or Installation
Testing and commissioning
Group -B-CHT Unit _ Electrical Drive Package
Group -B-CHT Unit _ Mandatory Spares _List as per MR
Group -B-CHT Unit _ Site Training
Group -B-CHT Unit _ Site Supervision of Erection or Installation
Group-C-DCU Unit _ Electrical Drive Package
Group-C-DCU Unit _ Mandatory Spares_List as per MR
Group-C-DCU Unit _ Site Training
Group-C-DCU Unit _ Site Supervision of Erection_ Installation
9179972
GEM/2026/B/7405985
Two Packet Bid
Gruop A- DHDT Unit_Electrical Drive Package,Gruop A- DHDT Unit _ Mandatory Spares _List as per MR,G
Dakshina Kannada, Karnataka
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
GM Finance, Refinery Division-Mangalore Refinery & Petrochemicals Ltd, Kuthethoor, Mangalore-575030, Karnatak State,, Materials Department, Mangalore Refinery & Petrochemicals Limited, Ministry of Petroleum and Natural, (Mrpl)
₹84.3 L
31 Jul 2026
1 Apr 2026
31 Jul 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Gruop A- DHDT Unit_Electrical Drive Package | Gruop A- DHDT Unit
A.1. Electrical Drive Package _Motor+ VFD+ Transformer+Coupling + Accessories_including engineering required for inetgration of package ..... Refer detailed description enclosed under Section 8 of SOR/BOQ
A.1.1 - High speed Ex d induction motor
A.1.2 - VFD _air_water cooled with provision of adding hot standby redundant VFD in future
A.1.3 - Converter duty transformer _K-rated, ONAN_ONAF type
A.1.4 - All other associated items required as per technical specification and detailed Engineering | 1 | Nos | DINESH_MAINT | 480 |
| 2 | Gruop A- DHDT Unit _ Mandatory Spares _List as per MR | A.2 - Mandatory Spares _List as per MR for Gruop A- DHDT Unit | 1 | Lot | DINESH_MAINT | 480 |
| 3 | Gruop A- DHDT Unit_ Site Training | A.3 -Site Training for Gruop A- DHDT Unit | 4 | man-day | DINESH_MAINT | 480 |
| 4 | Gruop A- DHDT Unit _ Site Supervision of Erection or Installation, Testing and commissioning | A.4 - Site Supervision of Erection / Installation, Testing and commissioning for electrical drive package as per requirements specifid in MR for Gruop A- DHDT Unit Day - upto 8 hours work | 90 | man-day | DINESH_MAINT | 480 |
| 5 | Group -B-CHT Unit _ Electrical Drive Package | Group -B-CHT Unit
B.1 - Electrical Drive Package _Motor + VFD + Transformer +Coupling + Accessories_ including engineering required for inetgration of package..... Refer detailed description enclosed under Section 8 of SOR/BOQ
B.1.1 - High speed Ex d induction motor
B.1.2 - VFD _air_water cooled with provision of adding hot standby redundant VFD in future
B.1.3 - Converter duty transformer _K-rated, ONAN_ONAF type
B.1.4 - 6.6kV CICO Vacuum Circuit Breaker _VCB_ panel
B.1.5 - All other associated items required as per technical specification and detailed Engineering | 1 | Nos | DINESH_MAINT | 480 |
| 6 | Group -B-CHT Unit _ Mandatory Spares _List as per MR | B.2 - Mandatory Spares _List as per MR for Group -B-CHT Unit | 1 | Lot | DINESH_MAINT | 480 |
| 7 | Group -B-CHT Unit _ Site Training | B.3 -Site Training for Group -B-CHT Unit | 4 | Man day | DINESH_MAINT | 480 |
| 8 | Group -B-CHT Unit _ Site Supervision of Erection or Installation, Testing and commissioning | B.4 - Site Supervision of Erection _ Installation, Testing and commissioning for electrical drive package as per requirements specifid in MR for Group -B-CHT Unit Day - upto 8 hours work | 90 | Man day | DINESH_MAINT | 480 |
| 9 | Group-C-DCU Unit _ Electrical Drive Package | Group-C-DCU Unit
C.1 - Electrical Drive Package _Motor + VFD + Transformer +Coupling + Accessories_ including engineering required for inetgration of package..... Refer detailed description enclosed under Section 8 of SOR/BOQ
C.1.1 - High speed Ex d induction motor
C.1.2 - VFD _air_water cooled with provision of adding hot standby redundant VFD in future
C.1.3 - Converter duty transformer _K-rated, ONAN_ONAF type
C.1.4 - All other associated items required as per technical specification and detailed Engineering | 1 | Nos | DINESH_MAINT | 480 |
| 10 | Group-C-DCU Unit _ Mandatory Spares_List as per MR | Charges for Mandatory Spares_List as per MR_Group-C-DCU Unit | 1 | Lot | DINESH_MAINT | 480 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9179972.pdf
GEM_BID • 0.15 MB
ts_mrpl_2026-03-31-20-10-29_0f33cf58cb369705e42e13afc03be849.pdf
GEM_BOQ • 22.14 MB
boq_item_sample_file2_2026-03-31-20-10-29_4038887c4ee91eb2907ae52df97b1985.csv
GEM_BOQ • 0.00 MB
1774971652.pdf
GEM_OTHER
1774971667.pdf
GEM_OTHER
1774975357.xlsx
GEM_OTHER • 0.06 MB
0gc1hdaf7b180e80d432693c48fecaf399228.pdf
GEM_OTHER • 0.08 MB
ATC_d410b0aa-ddd2-4227-bd831775029017294_PSTALIN_PROJECTS.pdf
GEM_OTHER • 6.62 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.71 MB
corrigendum_4342399.pdf
PDF • 0.05 MB
corrigendum_4291615.pdf
PDF • 0.05 MB
corrigendum_4233974.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].