Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.5 L+₹4.7 L (21.6%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹56,600
Closing Date
9 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bhisiana
GE (AF) Bhisiana PIN-151201
As per BOQ/ Price Schedule
2024_MES_641606_1
GE/BHI/CAP/2023-24
Open Tender
Civil Works
Item Rate
150 days
GE (AF) Bhisiana
As per NIT/ Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Bhisiana
₹56,600
22 Mar 2024
9 Feb 2024
11 Mar 2024
9 Feb 2024
9 Mar 2024
23 Feb 2024
9 Feb 2024 - 22 Feb 2024
Amount
34W/CAP-07/2023-24 (B/R WORKS)
Excavating over areas, n exc 1.5m deep and getting out in any type of soil.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for hardcore of broken bricks of gauge n exc. 63 mm , deposited , spread and levelled and compacted in layers n exc. 15 cm thick , watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajja etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchion and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
- ditto- as ser item no 21 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, chajjas, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M/L for rendering 5 mm thick in CM 1 : 4 on brick or concrete surfaces (in ceiling) etc finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 12 mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra cement) etc,complete all as specified and directed.
M & L rendering 15mm thick on cement mortar 1:4 finished fair faces of brick/concrete surfaces even and fair without using extra cement .
M&L applying 1-2 mm thick wall care putty (JK/Birla/berger) on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified.
M & L for applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
M & L for applying distemper oil emulsion over one coat of primer on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for applying Two or more coats of premium quality exterior emulsion paint over old/new plastered/unplastered surfaces of walls, pillars, cornices including priming coat of exterior primer complete.
M & L for 75 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
S&F Curtain rails, mild steel, chromium plated, including fixing of brackets and both ends decorative nobs, complete all as speccified and directed as per approved sample by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonary, built in cement mortar or cement lime mortar.complete all as specified and directed.
Dismantling wall & ceiling board any type, any thickness including cover fillets complete all as specified & directed.
M&L for Anodised aluminium snap grid frame work for false ceiling complete all as specified
M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for Non asbestos fibre cement boards 595x595x4mm thick fixed in ceiling Aluminium frame work with screws complete all as specfied.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified.
M&L for joint free dark shade/double charged vitrified tiles 9 to 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified.
M&L for joint free dark shade/double charged vitrified tiles 9 to 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:3 to receive vertical tiles complete all as specified.
M&L for complete removal of existing treatment of internal wall surface of wall and applying Two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour incl primer complete, as per manufacturer's specification complete all as specified and directed.
M&L for 1-2 mm thick wall care putty on internal surface of wall area complete all as specified & directed.
Taking down chowkats & shutters without taking off shutters from the frame, size of opening exc. 1.50 sqm but not exc 4 sqm each complete all as specified and as directed.
S & F for Anodised aluminium frame for doors, windows ventilators (Powder Coated) with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated Anodised aluminium sliding window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
M & L sheet glass ordinary quality 5.5mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed by Engr-in-Charge.
M&L for solar control film 25 micron reflective type sticked to glass panes as per instruction of manufacturer
Supply and fixing Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tack or galvanised wire staple complete.
S&F Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc. complete all as specified and as directed.
M&L for 10mm thick Screed bed or bedding layer in cement mortar 1:4, laid on roof, mixed with water proofing compound when concrete is green, as per manufacturere instructions complete all as specified. (Note - Water proofing compound shall be measured and paid separately).
Supplying only integral water proofing compound, ISI marked complete all as specified and as directed.
M&L for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in three coats. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. (Make: Asian paints or equivalents). Note: The work shall be executed by the authorized applicator of the manufacturer only.
Surface excavation n. exc. 30 cm deeep and averaging 15 cm in any type of soil getting out complete.
M&L for continuous brick edging with burnt clay brick sub class 'B'; with width equal to the width of the brick; laid dry on end vertically complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base to paving complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and as directed by the Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete.
M&L for PCC type B-2, 1:2:4 (using 40mm graded stone aggregate) for foundation filling, mass concrete and etc complete all as specified and as directed.Cement concrete in foundations, filling and mass concrete
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including
34W/CAP-07/2023-24 (E/M WORKS)
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:- One light/ fan point controlled by one, one way switch
All as per srl Item No. 1.59 here-in-before but for One ceiling fan/exhaust fan point controlled by one way switch 6 Amps.
All as per srl Item No. 1.59 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on independent board.
All as per srl Item No. 1.59 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on same board.
Material and labour for point wiring complete with ISI marked 4 Sqmm PVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 4 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly for 15 Amps switch socket combination all as specified
S&F in repairs modular fan regulator 120watt 240 V AC two module type complete all as directed.
S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body.
S&F in repairs modular Socket 6A-2/3 pin combined two module type complete all as directed.
S&F in repairs modular Socket 6A/16A-2/3 pin combined two module type complete all as directed. :Make: Legrand Britzy/Indo-Asian/L&T
S&F in repairs modular 1 way 6Amp switch 1 module complete all as directed.
S&F in repairs 1 way 15 Amp switch 1 module complete all as directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare diffused light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed. Note : 2 Runs of 4 Sqmm cable 1 run of 4 Sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
Supply and fix in replacement MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed.
Supply and fix in replacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA 'B' curve all as specified and directed.
S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
Supply and Fix GI tubing 15mm dia light grade for protection of GI earth wire complete all as specified and directed.
Supply and install hii wall split units indoor/ outdoor complete with cordless remote control unit and with i n built Heating and Cooling arrangement, 5 Star 4in 1 convertible Digital Inverter split AC twin rotary type,, Turbo tech dual temp display Anti fungal 100 percent copper , Anti dust , Antimicrobial protection , self diagonic 2 way swing 4 step adjustable cooling dual tempreture displa of 1.5 TR capacity and wall mounting type MS bracket for outdoor unit complete all as specified and directed.
Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit from MCB SPN to AC box all as specified and directed. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
Supply and fix voltage stabilizer for Automatic operation, copper wound, single phase natually air cooled indoor type & designed for input variation between 170V to 250V with output valtage stabilized at 230V with accuracy if + 2.5% and of capacity 4 KVA, with low and high voltage cutoff protection, protect equipment from potentially danger voltage , buil in thermal tempreture burnout with latest IC technology and assories complete complete.
S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20A to 32 A complete all as directed.
34W/MW-04/2023-24 (B/R WORKS)
Excavating over areas, not exceeding 1.5m deep and getting out in any type of soil complete all as specified and directed by Engineer in Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer in Charge.
M & L for hardcore of broken bricks of gauge n exc. 63 mm , deposited , spread and levelled and compacted in layers n exc. 15 cm thick , watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajja etc complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete Type B1 1:2:4 (20 mm graded aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc for fair finished complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
All as per ser item no 2.12 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 5 mm thick in CM 1 : 4 on brick or concrete surfaces (in ceiling) etc finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick in CM 1 : 6 on other than fair faces of brick work or concrete surfaces etc finished even and fair without using extra complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15mm thick on cement mortar 1:4 finished fair faces of brick/concrete surfaces even and fair without using extra cement .
M&L for Applying 1-2 mm thick wall care putty (JK/Birla/berger) on walls, including making surface even and smooth using sand paper before applying Priming coat, complete all as specified.
M&L for Applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
M&L for Applying distemper oil emulsion over one coat of primer on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for applying Two or more coats of premium quality exterior emulsion paint over old/new plastered/unplastered surfaces of walls, pillars, cornices including priming coat of exterior primer complete all as specified and directed by Engineer in Charge.
M&L for 75 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M&L for joint free dark shade/double charged vitrified tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) for laying floor finishes complete all as specified and directed by Engineer in Charge.
M&L for joint free dark shade/double charged vitrified tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.42 sqm on vertical surfaces as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement plaster in CM 1:3 to receive vertical tiles complete all as specified and directed by Engineer in Charge.
M&L for Glazed ceramic coloured tiles in vertical surface 350x250x7mm / 450x300x7mm thick including 10mm thick cement plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engineer in Charge.
S&F china wash down water closet padestal pattern white excluding flush and fix to position, including seat cover and connection to drain etc complete all as specified and directed by Engineer in Charge.
S&F Vitreous China wash basin, white , flat back,size 550x400mm including pedestal white incl 32mm brass CP coupling to basins etc, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with waste pipe complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) floor trap (Medium duty), plain with SS grating with hole/without hole including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed by Engineer in Charge.
S&F flush pipe of Polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed by Engineer in Charge.
S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer in Charge.
S&F 15mm dia brass chromium plated centre hole wash hand basin mixer with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed by Engineer in Charge.
S&F 15 mm bore Angle cock, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S &F 15mm dia Bib taps, long body, Chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F CP Health Faucet with 1.20 mtr metalic expandable tube & hook complete all as specified and directed by Engineer in Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer in Charge.
S&F CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer in Charge.
S&F Stainless Steel Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr-in-Charge.
S&F Powder coated Anodised aluminium frame for doors, windows, ventilators, partations with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, mortice locks anodised aluminum snap beading screws etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder coated Anodised aluminium window and ventilator shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium decorative grill of size of mesh 50mmX50mm fixed with doors, window for safety of glass etc. complete all as specified and directed by Engr-in-Charge.
S & F sheet glass 5.5 mm thick ordinary quality and glazing with oil putty/ any type of beading in square/rectangular exceeding 1.00 Sqm in each pane complete all as specified and directed by Engr-in-Charge.
M&L for solar control film 25 micron reflective type sticked to glass panes as per instruction of manufacturer instructions complete all as specified and directed by Engineer in Charge.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed by Engr-in-Charge.
S&F Curtain rails, mild steel, chromium plated, including fixing of brackets and both ends decorative nobs, ( sample approved by GE) complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft and loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonary, built in cement mortar or cement lime mortar complete all as specified and directed by Engineer in Charge.
34W/MW-04/2023-24 (E/M WORKS)
M&L for concealed Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3,Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
All as per Item No 2.35 for One 3 Pin Switch socket Combination 6 amp on the independent board.
All as per Item No 2.35 for One 3 Pin swich socket Combination 6 amp on the same board with other switches.
M&L for concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3,Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed by Engineer in Charge.
S&F Ceiling Rose, 65X17mm 3 Terminals, PVC Polycarbonate, Isolated body and complete all as specified and as directed by Engineer in Charge.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 to 63 Amp, 240 /415 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F MCB Single Pole 40 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth lead wire 4.0 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected up to main LT Panel /Test point and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including demolition of old earthing, excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2020(Part-I) complete all as specified and as directed by Engineer in Charge.
Supply and fixing LED luminaire, 36/40 watt, 220 V AC recessed type suitable for armstrong/ grid ceiling with super bright LES fittings and high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer in Charge.
S&F Single pole and neutral enclosure with a two pin and metallic AC earth plug and socket complete with one single pole MCB of 32A, complete all as specified and directed by Engineer in Charge.
M/s Luxmi Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .