| 1 | L1₹22.0 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹22.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.8 L+₹5.8 L (26.6%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | ₹27.8 L+₹5.8 L (26.6%) | L2 | Rejected-Finance Quoted amount is more than L1 |
| 3 | L3₹31.1 L+₹9.1 L (41.3%)Rejected-Finance | ₹31.1 L+₹9.1 L (41.3%) | L3 | Rejected-Finance Quoted amount is more than L1 |
| 4 | L4₹32.2 L+₹10.2 L (46.2%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | ₹32.2 L+₹10.2 L (46.2%) | L4 | Rejected-Finance Quoted amount is more than L1 |
| 5 | L5₹32.4 L+₹10.4 L (47.2%)Rejected-Finance | ₹32.4 L+₹10.4 L (47.2%) | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Nov 2022, 6:00 pmClosed
Major S Rakesh
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/REPLACEMENT OF ELECTRIC FITTING AND FUXTURES INCLUDING REWIRING TO CERTAIN MD QTRS AT 1 I R O FLIGHT, VEERLINE, ENGINEER LINE, TPT LINE AND REST CAMP AREA UNDER GE RANCHI
2022_MES_556529_1
8400/1160/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹60,000
Yes
13 Dec 2022
8 Oct 2022
5 Nov 2022
9 Oct 2022
3 Nov 2022
22 Oct 2022
Amount
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc for re use to be measured separetly including making good the disturbed portion/surface complete all as specified and as directed.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed..
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 6 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and as directed.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified and as directed.
S & F ceiling fan regulator switch type, step type, flush type heavy duty, 120 watts suitable to work on 230 volts Ac supply including removal of old unserviceable one complete all as specified and as directed.
S & F for Bell push modular 6 Amps single module complete all as specified and as directed.
S&F bell push , flush type, 5 amp , complete all as specified and as directed.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C complete all as specified and as directed.
S & F for Lamp holder, PVC body suitable for batten fitting with LED bulb 9 W complete all as specified and as directed. Make : Havells, HPL, Bajaj
S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified and as directed.
S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified and as directed..
S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified and as directed.
S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 2.5 sqmm cable and one run of PVC casing caping will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 10.0 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including with two runs of PVC insulated 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- four runs of 10.0 sqmm cable, two runs of 6.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit.
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified and as directed.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified and as directed.
S&F 20W LED 6000K (4’) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, optics diffused, complete all as specified and as directed. CA number, Two Years Warranty End Date & Phone number of Contractor to be endorsed in the item with indelibile ink. Make : Phillips/Havells/ Crompton.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including provosion of LED bulb 10/11 watts complete all as specified and directed. Make- Havells, Philips, Bajaj.
S & F for LED 10 watts batten aluminium extruded (mirror light) with decorative end caps complete all as specified and directed. Make- Bajaj, Havells, Philips.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and directed. Make :- Bajaj , Philips, Havells.
S&F IP 65 rated LED bollard with robust design and efficient light distribution 10 Watt complete all as specified and as directed. Make: Crompton/ Havells/ Philips
S & F for Energy Efficent Exhaust Fan of 450 mm sweep made of metal body Ventil Air -Ds type complete with louver with bolts and nits & washers size of the bolt 15 cm long 12 mm dia embeded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from cieling rose to exhasut fan base complete all specified and directed. Cost of point wiring & suitable opening for fixing of exhast fan is deemded to be included in the overall rate quoted, complete all as specified and as directed. Make Havells, Philips, Crompton
S &F of bulding security light energy conservation LED roadway lighting luminaires 25W based deep drawn aluminium housing in grey finish with clear acrylic and cast alum pipe mounting attachment IP66 protection including security light brackets and Supply & Fixing Bracket made out of GI light grade pipe of 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 500 and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified & directed. Make: Philips/Havells/crompton
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed.
S & F for casing and capping size 40 mm including removal of old unserviceable one complete all as specified and directed
S & F for casing and capping size 25 mm including removal of old unserviceable one complete all as specified and directed
S & F for casing and capping size 20 mm including removal of old unserviceable one complete all as specified and directed
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S & F for MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S & F for MCB Single pole and neutral rated capacity 63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S & F for MCB Single pole rated capacity 40 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S & F for MCB Single pole rated capacity 63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and directed.
S&F in replacement of flexible wire twin core copper conductor of size 23/0.0076 for fans and tube lights/ pendant fittings connection all as specified and directed
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replacing 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire, one twin core cable of size 10 Sqmm multi -strand complete all as specified and directed.
All as per item No 55 above but size 6 sqmm twin core cable.
All as per item No 55 above but size 4 sqmm twin core cable.
S&F Fan condenser, 2.5 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp at different locations as per site given by Engineer-in-Charge
Taking down old burnt electric single phase meter of any type, submitting it to MES Store and S&F CRCA sheet metal enclosure double door, outdoor type suitable size including single phase Energy meter Fixed with cable terminals incl 3 nos HDPE gland fixed on pole/wall/panel/where direction by Engr in charge with clamp nuts,bolts, PCC along with new waterproof wooden box etc, complete all as specified and directed. Make:-Indoasian/Havells / HPL / L&T .
Taking down old burnt electric single phase meter of any type, submitting it to MES Store and S&F CRCA sheet metal enclosure double door, outdoor type suitable size including single phase Energy meter Fixed with cable terminals incl 3 nos HDPE gland fixed on pole/wall/panel/where direction by Engr in charge with clamp nuts,bolts, PCC along with new waterproof wooden box etc, complete all as specified and as directed.Make:-Indoasian/Havells / HPL / L&T .
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 15mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991.Note :(a)Three photos covering the steps involved in installation with the electrode plate be atttached witht the bills for payments. (b) The item should be connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
BHARATI ENTERPRISES
Commercial Electric Co.
arics infrastructure
SHARDA CONSTRUCTIONS
M/s Shobha Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .