| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | ₹4.7 L Quoted ₹5.0 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹5.1 LRejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | ₹5.1 L | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹5.1 LRejected-Finance | ₹5.1 L | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹6.1 LRejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | ₹6.1 L | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹6.4 LRejected-Finance 17 BRAHAMPUTRA COMPLEX KALA AAM BULANDSHAHR BULANDSHAHR UTTAR PRADESH 203001 UDYAM UP 18 0025566 | BULANDSHAHR | UTTAR PRADESH | 203001 | ₹6.4 L | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | H C CONSTRUCTION L3 | Industrial Traders L2 | M/s JS Constructions L4 | M/S Husna Electrical Works L1 | HINDUSTAN TRADING COMPANY L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the unseviceable geyser of any capacity and in any position horizontal or vertical and disconnection of electric/water supply lines for repair/over hauling/replacement of unserviceable parts and re-fixing the geyser in serviceable condition after assembling, testing & reconnecting the electric & water supply line complete all as specified and directed. | 100 | Each | 50 ₹5,000 | 100 ₹10,000 | 50 ₹5,000 | 100 ₹10,000 | 90 ₹9,000 |
| 2.00 | S&F in repair heating element of geyser of capacity 2 KW any shape suitable for existing geyser 'ISI marked' complete all as specified and directed | 80 | Each | 550 ₹44,000 | 500 ₹40,000 | 600 ₹48,000 | 400 ₹32,000 | 330 ₹26,400 |
| 3.00 | S&F in repair heating element of geyser 1.5 KW any shape suitable for existing geyser 'ISI marked' complete all as specified and directed | 20 | Each | 400 ₹8,000 | 450 ₹9,000 | 500 ₹10,000 | 400 ₹8,000 | 330 ₹6,600 |
| 4.00 | S&F in repair thermostat of size geyser 200mm long 'ISI marked' suitable for existing geyser complete all as specified and directed | 80 | Each | 300 ₹24,000 | 200 ₹16,000 | 300 ₹24,000 | 150 ₹12,000 | 90 ₹7,200 |
| 5.00 | S&F in repair indicating LED lamp of any shape for geyser complete all as specified and directed | 30 | Each | 25 ₹750 | 30 ₹900 | 40 ₹1,200 | 20 ₹600 | 15 ₹450 |
| 6.00 | M&L for glass wool filled in any type of geyser | 2 | Kg | 80 ₹160 | 110 ₹220 | 140 ₹280 | 100 ₹200 | 60 ₹120 |
| 7.00 | M&L for repairing of leakage of inner tank of geyser by brazing complete including required denting etc for any type and make & capacity of Geyser complete all as specified & directed. | 20 | Each | 200 ₹4,000 | 380 ₹7,600 | 440 ₹8,800 | 250 ₹5,000 | 50 ₹1,000 |
| 8.00 | S&F in repair heat resistant stainless steel braided connection/ hose pipe 600 mm long heavy duty for geyser with two stainless steel coupling nut suitable for 15mm bore GI pipe complete all as speified & directed. | 150 | Each | 160 ₹24,000 | 150 ₹22,500 | 180 ₹27,000 | 150 ₹22,500 | 98 ₹14,700 |
| 9.00 | M&L for Painting of Geyser of capacity 25/50 Litre complete with two coat synthetic enamelled paint by spraying including cavities with filter after cleaning all dust etc including writing the MES No,complete all as specified and directed. | 25 | Each Job | 50 ₹1,250 | 120 ₹3,000 | 145 ₹3,625 | 100 ₹2,500 | 90 ₹2,250 |
| 10.00 | Supply and fix in repair geyser fastner 4'' to 6" steel with all accessories complete all as specified and directed | 50 | Each | 45 ₹2,250 | 55 ₹2,750 | 55 ₹2,750 | 100 ₹5,000 | 40 ₹2,000 |
Tender Value
₹6.6 L
EMD Value
₹13,500
Closing Date
12 Dec 2023, 6:00 pmClosed
GE (AF) BKT
GE (AF) BKT, LUCKNOW
REPAIR/ MAINT OF DBs, EARTHING, GEYSER AND OTHER CONNECTED WORKS AT AF STN BKT
2023_MES_628408_1
8738/BKT/E8
Open Tender
Civil Works
180 days
GE (AF) BKT
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹13,500
24 Jun 2026
15 Nov 2023
14 Dec 2023
15 Nov 2023
12 Dec 2023
29 Nov 2023
Amount
Taking down the unseviceable geyser of any capacity and in any position horizontal or vertical and disconnection of electric/water supply lines for repair/over hauling/replacement of unserviceable parts and re-fixing the geyser in serviceable condition after assembling, testing & reconnecting the electric & water supply line complete all as specified and directed.
S&F in repair heating element of geyser of capacity 2 KW any shape suitable for existing geyser 'ISI marked' complete all as specified and directed
S&F in repair heating element of geyser 1.5 KW any shape suitable for existing geyser 'ISI marked' complete all as specified and directed
S&F in repair thermostat of size geyser 200mm long 'ISI marked' suitable for existing geyser complete all as specified and directed
S&F in repair indicating LED lamp of any shape for geyser complete all as specified and directed
M&L for glass wool filled in any type of geyser
M&L for repairing of leakage of inner tank of geyser by brazing complete including required denting etc for any type and make & capacity of Geyser complete all as specified & directed.
S&F in repair heat resistant stainless steel braided connection/ hose pipe 600 mm long heavy duty for geyser with two stainless steel coupling nut suitable for 15mm bore GI pipe complete all as speified & directed.
M&L for Painting of Geyser of capacity 25/50 Litre complete with two coat synthetic enamelled paint by spraying including cavities with filter after cleaning all dust etc including writing the MES No,complete all as specified and directed.
Supply and fix in repair geyser fastner 4'' to 6" steel with all accessories complete all as specified and directed
S&F in repair 15 mm dia chromium plated (CP) brass angle valve for geysers with both end screwed, complete all as specified & approved.
S&Fin repair Non return valve (ISI Marked) brass 15mm dia heavy duty complete all as specified & approved by EIC.
S&F in repair safety valve ISI marked for any make of geyser, complete all as specified and approved.
S&F in repair fuseable plug for any make of geyser, complete all as specified and approved.
S&F in geyser inner tank made of steel of capacity 25 ltrs for any make of geyser ' ISI marked' , complete all as specified and approved.
S&F in geyser inner tank made of copper of capacity 25 ltrs for any make of geyser ' ISI marked' , complete all as specified and approved.
S&F in repair Geyser syphon assembly 25 / 50 ltrs 06/ 09 holes, geyser assembly' ISI marked' , complete all as specified and approved.
S&F in repair GI tubing 15mm dia 'medium grade' with all fittings fixed on walls / floors as vent pipe including complete all as specified & directed.
M&L for point wiring with two single core PVC insulated unsheathed multi stranded FRLS-H copper conductor cable of size 2.5 Sqmm 1100 volts grade in and including PVC conceled conduit of medium grade of size 20 to 25 mm including making good the disturbed surface of wall with colour washing /distempering the surface to match the existing one with all accessories with suitable size of 1 to 8 module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc including provision of one single core PVC insulated and unsheathed multi stranded copper cable of size 2.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dolly switch board complete all as specified and directed.
S&F socket outlet 5 pin 20 Amps modular type, 2 module with suitable size of module metal flux boxes including modular front cover plate and back plate for mounting modular type switch & socket with one single pole switch 15 Amps (1 module) including electrical connection complete all as specified & directed.
Supply and laying PVC insulated, PVC sheathed 2 core alluminium flexible round cable of each core size 2.5 Sqmm, 1100 volt, 50 HZ complete all as specified and directed.
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multistranded FRLS-H copper conductor cable of size 10 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 10 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic concealed conduit of size 25 mm on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as specified and directed (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the quoted unit rate).
S&F in repair plug top 3, pin 15 Amp complete all as specified & directed.
S&F in repair sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F in repair sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as directed.
S&F in repair sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F in repair sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way verticall type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.
S&F in repair sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.
S&F in repair industrial socket 5 pin, 3P+E 240V, AC of rating 32 Amps with industrial plug top complete with triple pole MCB and all fixing accessories all as specified & directed.
S&F in repair industrial socket 3 pin, 2P+E 240V, AC of rating 20 Amps with industrial plug top complete with double pole MCB and all fixing accessories all as specified & directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB single pole, 32 to 40 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB DP 40 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ 25 KA breaking capacity complete all as directed.
Supply & fix exhaust fan of size 350mm sweep having 1200 RPM, 50 Hz, 230 V, Copper winding made of sturdy engineering plastic complete with louvers shutter complete all as directed.
M&L for flame proof point wiring with two single core FRLS-H PVC insulated & PVC unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including stove enamelled steel conduit of size 25 mm dia with all accessories and one single core PVC insulated & PVC sheathed solid FRLS copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps switch one way complete. (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the quoted unit rate).
M&L for switch flame proof rotory type with termination box in LM 6, 16 A,single phase 250 volts,complete all as specified and directed
Supply and fixing LED Light Fitting 1x16 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Material, labour (Technician & Helper) and T&P including testing eqpts for carring outs comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & admin area by tightening of nut bolts arranging earth lead in allighnment manner replacing unservicable earthing lead ,funnel ,pit cover and PCC pits etc (which will be paid as supply only) and testing of earthing and recording result in register (as per procedure provided as directed ,If result found more than permissible limit reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing result and recordsing in register including levelling refilling of earth settle down near pit. Note-(i) Necessary compound required for recharging shall be measured and paid separately under item No 2 here-in-after. (ii) During AMC of earthing , if any parts of the earthing is required to be replaced the same will be done by the contractyor as per directed by EIC . The cost of such parts shall deemed to be included in the unit rate quoted by th contractor for AMC. (iii) Pouring of salt/chemical/charcoal water in the earth pit is included in the rate quoted. (iv) Total no of earthing to be checked in amonth-100-130 nos
M& L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC base 1:4:8 type using 40 mm agregrate of size 750x750x100 mm thick with precast RCC cover 40 mm thick in PCC 1:2:4 type B1 using 20 mm graded stone aggregrate with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed. including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified ny EIC complete including testing on completion complete all as specified and directed.
Same all as item no. 3 above here in before but connected to galvanised earth strip 32x6 mm as earthing lead complete all as specified and directed.
S&F 15mm dia GI pipe medium grade in any length fixed to wall/ floor with required GI medium grade ISI mark fitting including all necessary fittings, clamps, etc complete all as specified and directed.
Industrial Traders
H C CONSTRUCTION
M/s JS Constructions
HINDUSTAN TRADING COMPANY