Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.6 LAdmitted-Finance | -8.99% | ₹3.6 L | L1 | Admitted-Finance |
Tender Value
₹3.9 L
EMD Value
₹7,860
Closing Date
18 Feb 2026, 6:00 pmClosed
SPD, RCSCE, Jaipur, Block No. 6, Dr. Radha Krishan
SPD, RCSCE, Jaipur, Block No. 6, Dr. Radha Krishan Siksha Sankul, JLN Marg, Oppsite of OTS, Jaipur
Major Repair Work at GPS UDAK GAON, JHOTWARA CITY, JAIPUR
2026_RCSCE_535061_41
NIT15 (CIVIL)/2025-26/6940 DATE 02-02-2026 ADPC SMSA JAIPUR
Open Tender
Civil Works
60 days
Major Repair Work at GPS UDAK GAON, JHOTWARA CITY
As per Tender Documents, NIB Documents
2 documents required · 2 mandatory
₹1,000
DPC RMSA JAIPUR / MD RISL JAIPUR
₹7,860
11 Mar 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
Building & Sainatary Work Based on BSR PWD - 2022, Jaipur Circle, Electric Work Based on BSR PWD 2022, Jaipur Circle, Part -A Civil Work
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
PCC in foundation : Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 graded stone aggregate 20 mm nominal size).
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks in Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
External Plaster : Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished 20 mm thick
Grading roof for water proofing treatment with water proffing compound: Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size)
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.
Exterior finishing :- Finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. New work (two or more coat applied @1.67/ ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm.)
R/R Dry stone kharanja under floor
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc Complete 75mm thick with 20mm thick nominal size aggregate.
Nano technology water proofing, thermal insulation protection coating : Nano technology water proofing, thermal insulation protectioncoating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. 15.28.2 Nano technology water proofing, thermal insulation protection coating 9 layer process for increasing life of building and damage control protection for walls.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in 2 coats non silicon based thermal insulation coating highly elasticity in nature with 2 coats with 1000 micron thickness 2 top coats of anti slippery, natural transparent high shine chemical for better life of the treatment. Nano technology water proofing or anti stain protection coating 5-7 layer process for increasing life of all stone fascia/facades/flooring or stone building and damage control protection, life 7-9 years, warranty 5 years-- before coating washing of stone and degreasing of that area is done 1 coat. (Removing of algae/moss/blackness/stains/rust etc. is extra) then after drying doing 1 coat of Nono technology hydrophobic prime. After this on dry area Nano technology water proofing treatment in 3 coats wet on wet. In case of anti stain treatment 2 top coats of anti stain, anti slippery, natural transparent high shine or matt chemical treatment is done. BSR_B15 S
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required Partly fixed and partly openable [ fixed area not to exceed 33%]
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
Guard Bar - Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 12mmx12mm
Internal Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick Sqm
External Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick Sqm
6 mm thick cement plaster to celling of mix 1:3 ( 1Cement :3Fine sand)
Kota stone slabs 25 mm thick inover 20mm (Av) thick base laid over and jointed with grey cement slirry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 ( 1 cement :4 coarse sand )te For area of each slab 2001 to 5000 Sqcm
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete
Internal Finishing: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
Internal Finishing: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats )
Exterior finishing :- Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work
Exterior finishing :- Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision Old Work
Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 13.49 MB
NIT15Civilandspcial.pdf
Tender Documents • 22.78 MB
BOQ_955301.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid