Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.3 LAdmitted-Finance | ₹97.3 L | L1 | Admitted-Finance |
| 2 | L2₹98.4 LAdmitted-Finance | ₹98.4 L | L2 | Admitted-Finance |
| 3 | L3₹99.6 LAdmitted-Finance | ₹99.6 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Techno-Commercially not qualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Techno-Commercially not qualified |
| Sl No | Description | Qty | Unit | JK Electric Engineers Pvt. Ltd. L3 | TZ Engineering Works L1 | M/S R R ELECTRICAL SERVICES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Erection of 11 Mtr. Long Pole ( ST-410 SP56) complete along with pit excavation and 1/6 th of pole embedded in soil with base plate and cap as per relevant REC standards (Complete Job). | 8 | No | 26,000 ₹2.1 L | 23,000 ₹1.8 L | 24,000 ₹1.9 L |
| 2.00 | Supply of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS (Single Circuit + one spare cable) as per relevant IS Standards | 1,400 | Mtr | 3,900 ₹54.6 L | 4,875 ₹68.3 L | 4,500 ₹63 L |
| 3.00 | Supply of HDPE Pipe ( PN4,PE63/6PN80) Outer Dia 200mm & Inner Dia 176 mm | 1,400 | Mtr | 750 ₹10.5 L | 710 ₹9.9 L | 900 ₹12.6 L |
| 4.00 | Laying / Installation , testing & commissioning of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS using HDD( Boring) method, trenchless digging along with laying & installation of HDPE Pipe (200 mm OD) for laying of 33KV, 400 Sqmm 3-Core Cable, inclusive of all required pulling pits etc. required as per site conditions/ as per the directions of site Engineer ( Complete Job). The pulling pits (if any ) needs to be restored to its original surface. | 1,320 | Mtr | 1,600 ₹21.1 L | 710 ₹9.4 L | 900 ₹11.9 L |
| 5.00 | Laying / Installation , testing & commissioning of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS above ground level to be laid along side ST Poles along with Laying of HDPE Pipe (200 mm OD) for laying of 33KV, 400 Sqmm 3-Core Cable, ( Complete Job). | 80 | Mtr | 700 ₹56,000 | 100 ₹8,000 | 300 ₹24,000 |
| 6.00 | Supply, Installation, Testing & Commissioning of 33 KV isolator with earthing blades (36 KV, 800 Amps, outdoor, 25KA) with clamps as per relevant Standards | 2 | Set | 85,000 ₹1.7 L | 45,000 ₹90,000 | 75,000 ₹1.5 L |
| 7.00 | Supply, Installation, Testing & Commissioning of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) with clamps as per relevant Standards | 3 | No | 12,000 ₹36,000 | 1,000 ₹3,000 | 20,000 ₹60,000 |
| 8.00 | Supply, Laying, Stringing and binding of 200 mm² ACSR Conductor for 33 kv line as per relevant Standards | 0.1 | Kms | 4,00,000 ₹40,000 | 10,000 ₹1,000 | 3,00,000 ₹30,000 |
| 9.00 | Providing / Fabrication & Fixing of GI Channel / Angle Iron duly fabricated as per site requirement & as per relevant Standards | 2,200 | Kg | 140 ₹3.1 L | 150 ₹3.3 L | 130 ₹2.9 L |
| 10.00 | Supply, Installation, Testing & Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards | 12 | No | 800 ₹9,600 | 600 ₹7,200 | 650 ₹7,800 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
13 Dec 2025, 3:00 pmClosed
Executive Engineer STD-I
PDD Complex Bemina Srinagar
LAYING OF 33 KV XLPE, (3C X 400 MM2 SINGLE CIRCUIT, THREE CORE WITH ONE SPARE) ALUMINIUM ARMOURED UNDERGROUND CABLE INSIDE/ OUTSIDE Tulip and Botonical Garden ( For 33kv - O/H Cheshmashi-TRC line) by means of HDD Boring Method.
2025_PDD_296100_1
e-NIT No. STD I / 20 of 2025-26 Dated 22.11.2025
Open Tender
Electrical Works
60 days
Srinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Executive Engineer STD-1
₹2.3 L
13 Jan 2026
24 Nov 2025
15 Dec 2025
24 Nov 2025
13 Dec 2025
25 Nov 2025
24 Nov 2025 - 24 Nov 2025
Amount
Supply & Erection of 11 Mtr. Long Pole ( ST-410 SP56) complete along with pit excavation and 1/6 th of pole embedded in soil with base plate and cap as per relevant REC standards (Complete Job).
Supply of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS (Single Circuit + one spare cable) as per relevant IS Standards
Supply of HDPE Pipe ( PN4,PE63/6PN80) Outer Dia 200mm & Inner Dia 176 mm
Laying / Installation , testing & commissioning of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS using HDD( Boring) method, trenchless digging along with laying & installation of HDPE Pipe (200 mm OD) for laying of 33KV, 400 Sqmm 3-Core Cable, inclusive of all required pulling pits etc. required as per site conditions/ as per the directions of site Engineer ( Complete Job). The pulling pits (if any ) needs to be restored to its original surface.
Laying / Installation , testing & commissioning of 33kV, Three core 400 mm2 Aluminium ,round wire Armoured XLPE Cable , FRLS above ground level to be laid along side ST Poles along with Laying of HDPE Pipe (200 mm OD) for laying of 33KV, 400 Sqmm 3-Core Cable, ( Complete Job).
Supply, Installation, Testing & Commissioning of 33 KV isolator with earthing blades (36 KV, 800 Amps, outdoor, 25KA) with clamps as per relevant Standards
Supply, Installation, Testing & Commissioning of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) with clamps as per relevant Standards
Supply, Laying, Stringing and binding of 200 mm² ACSR Conductor for 33 kv line as per relevant Standards
Providing / Fabrication & Fixing of GI Channel / Angle Iron duly fabricated as per site requirement & as per relevant Standards
Supply, Installation, Testing & Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards
Supply, Installation, Testing & Commissioning of 33 kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting as per relevant Standards
Providing & Fixing of 0.2 PG Clamps suitable for 0.2 ACSR conductor as per relevant REC standards
Providing & Fixing of Galvanised Nuts & Bolts with washers as per relevant Standards
Supply & Fixing of route Marker as per relevant standards.
Supply, Installation, Testing & Commissioning of Cable Termination Kits (Indoor/Outdoor) suitable for Three core 400 mm2 Cable as per relevant REC standards.
Supply, Installation, Testing & Commissioning of Straight Through Jointing Kit for 400 mm² Cable as per relevant REC standards.
Providing and painting of 11 mtr S.T Poles with single coat of Red Oxide and two coats of Aluminium Paint as per relevant IS standards
Providing and fitting of Anti-Climbing Device with Clamps as per relevant standards
Providing and laying of Cement bottoming 1:2:4 mix as per REC Standards 0.66 cum /pole (Complete Job)
Construction of Brick Masonary Chamber (900x900x1050)mm with pre-cast RCC top slab, Cast Iron cover in CI Frame (38Kg) for cable loop as per relevant REC standards at termination points. The surface needs to be restored to its original position after construction of Brick Masonry chamber.
Construction of Brick Masonary Chamber (1830x1524x1050)mm with pre-cast RCC top slab, Cast Iron cover in CI Frame (126 kg) for straight joint as per relevant REC standards ( Jointing Pit) . The surface needs to be restored to its original position after construction of Jointing pit.
Providing & Fixing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI strip 25x3mm as per relevant REC Standards
Dismantling of existing 11mtr Long ST poles along with allied accessories including their carriage upto divisional stores (Complete Job)
Dismantling of existing 0.2 ACSR along with allied accessories including their carriage upto divisional stores (Complete Job)
M/S R R ELECTRICAL SERVICES (BID ID -2668871)
JK Electric Engineers Pvt. Ltd. (BID ID -2667174)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
0.30 MB
Tender Documents
Tender Documents • 0.71 MB
BOQ
BOQ • 0.33 MB
Download all tender documents and submit your bid