Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹33.9 L+₹1.8 L (5.49%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹34.1 L+₹2.0 L (6.12%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹34.5 L+₹2.4 L (7.36%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹24.4 L
EMD Value
₹48,740
Closing Date
8 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Adm Area Gwalior
GE AF Adm Area AF Station Gwalior
REPAIR MAINT REPLACEMENT OF UG (11 KV) CABLE, JOINTS AND CONNECTED WORKS AT AF STATION GWALIOR
2021_MES_481194_1
8132/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF Station Gwalior
Class E
Category b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE AF Adm Area Gwalior
₹48,740
Yes
3 Jan 2022
12 Oct 2021
15 Nov 2021
12 Oct 2021
8 Nov 2021
26 Oct 2021
12 Oct 2021 - 26 Oct 2021
60 days
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.
Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I
Supplying & Laying unreinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mmx180mmx40mm, factory made complete all as specified and directed.
All as per item no 5 here in before but laying only. Note: Old serviceable cable cover retrieved shall be reused in work.
Disconnecting, taking out and removing old existing unserviceable underground, HT, 11KV cable of any description and in any position complete including taking down protection pipe, cable cover etc all as specified and directed for the following sizes:-
(a) 95 Sqmm to 120 Sqmm, 3 Core
(b) 150 Sqmm to 240 Sqmm, 3 core
Laying, jointing and testing 11 KV, HT underground cable of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :-.
(a) 95 Sqmm to 120 Sqmm, 3 Core
(b) 150 Sqmm to 240 Sqmm, 3 core
(NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work. (ii) Additional quantity of HT cable, if any required, for replacing the defective portion of cable retrieved from dismantling /taking out, shall be measerd and paid under relevent item of sch.
Supply, laying, jointing and testing 11KV (Earthed), aluminium conductor, screened, XLPE insulated, armoured, shielded and PVC sheathed cables confirming to IS 7098 (Part II) laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- Make:-HAVELLS/ Gloster/Polycab/CCI.
(a) 95 Sqmm, 3 core
(b) 120 Sqmm, 3 core
(c) 185 Sqmm, 3 core
(d) 240 Sqmm, 3 core
Excavation for removing/ checking of HT cable joint with draining out water in trenches including returning filling of exisitng soil, sand, PCC cable cover and making good disturbed surfaces complete all as specified and directed.
M&L in replacement jointing and testing of straight through heat shrinkable end termination joint suitable 11 KV, XLPE/PVC insulated cable of following sizes complete including cutting the faulty straight through of any description and in any position complete all as specified and directed:- Make: denson/ 3M/ Rey-Chem/ M-Seal Notes:- (a) All necessary T&P, Blow Lamp, HT Megar shall be arranged by the contractor. (b) The contracor will rectify the joints with in 4 Hours after detecting of faults otherwise a penalty @ Rs 1000/= Per hour shall be recovered from contractor.
(a) 50 Sqmm to 95 Sqmm, 3 core
(a) 120 Sqmm to 185 Sqmm, 3 core
(c) 240 Sqmm to 300 Sqmm, 3 core
M&L in replacement jointing and testing of indoor type heat shrinkable end termination joint suitable 11 KV, XLPE/PVC insulated cable of following sizes complete including cutting the faulty indoor end termination joint of any description and in any position complete all as specified and directed:- Make: denson/ 3M/ Rey-Chem/ M-Seal Notes:- (a) All necessary T&P, Blow Lamp, HT Megar shall be arranged by the contractor. (b) The contracor will rectify the joints with in 4 Hours after detecting of faults otherwise a penalty @ Rs 1000/= Per hour shall be recovered from contractor.
(a) 50 Sqmm to 95 Sqmm, 3 core
(b) 120 Sqmm to 185 Sqmm, 3 core
(c) 240 Sqmm to 300 Sqmm, 3 core
M&L in replacement jointing and testing of outdoor type heat shrinkable end termination joint suitable 11 KV, XLPE/PVC insulated cable of following sizes complete including cutting the faulty indoor end termination joint of any description and in any position complete all as specified and directed:- Make: denson/ 3M/ Rey-Chem/ M-Seal Notes:- (a) All necessary T&P, Blow Lamp, HT Megar shall be arranged by the contractor. (b) The contracor will rectify the joints with in 4 Hours after detecting of faults otherwise a penalty @ Rs 1000/= Per hour shall be recovered from contractor.
(a) 50 Sqmm to 95 Sqmm, 3 core
(b) 120 Sqmm to 185 Sqmm, 3 core
(c) 240 Sqmm to 300 Sqmm, 3 core
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified
M & L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, while concrete is green over 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) with and including to make the road surface making good as per existing surface etc complete all as specified and directed by the Engineer in Charge.
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia sutable for 0.4 mpa working pressure. all as specified and directed by Engineer-in-Charge. (NOTE : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc)
Dismantling and Taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 80 mm bore,light grade (ISI marked) as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. (MAKE : TATA/JINDAL/TT SWASTIK)
Ditto as per item no. 17 above but GI tubing 100 mm bore.
M&L for checking and finding out pin point location of fault in HT 11KV underground cable with the help of fault locating high tech mobile machine complete all as directed. Notes:- (a) Charges for rent and transportation of the fault locating high tech mobile machine including DG set, necessary earth work for repair of HT cable, testing of cable after repair, charges for operator, engineer, electricians etc deemed to be included in the quoted rate. (b) Fault locating high tech mobile machine will be provided as and when required on short notice otherwise an amount of Rs 5000/= per day will be charged as penalty. (c) The quoted rate deemed to be be included irrespective of number of faults in a strech of 500 RM and no extra payment will be made for any number of fault with in the particular strech.
Supply, installation, comissioning and testing factory fabricated, CPRI approved, outdoor Kiosk type HV junction panel of size (L) 1.80 M X (W) 0.90 M X (H) 1.80M for 3 Phase, 11KV, AC, 50 Hz supply with and including Aluminium bus bar of 600 Amp rating, cubicle of appropriate size made out of 3.00 mm thick CRCA sheet and angle iron frame base and legs made out of angle iron of size 25mmX25mmX5mm, totally enclosed with top canopy, free standing, water, dust and vermin proof with IP 65 protection, powder coated internally and externally not less than 50 micron thick after seven tank pretreatment process including locking arrangement and angle iron legs in PCC 1:3:6, type C1 (Using 20 mm graded stone aggregate) complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and comman salt, PCC (1:3:6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for watering and 40mm dia medium earth lead protection pipe complete all as specified and directed.
Bharat Sales Corporation
UNIVERSAL AGENCY
M/s Yashika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .