Garrison Engineer
Garrison Engineer Chandimandir Panchkula Haryana 134107
GE/CHM-56/2021-2022 REPAIR AND MAINTENANCE OF COOLING APPLIANCES, INSTALLED IN VARIOUS UNITS AT CHANDIMANDIR
2021_MES_461999_1
GE/CHM-56/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer
₹70,000
Yes
28 Oct 2021
23 Jul 2021
30 Aug 2021
23 Jul 2021
28 Aug 2021
14 Aug 2021
60 days
Amount
Periodical maint of window type Air conditioner/split type air conditioner of 1/1.5/2.0 ton cap any make any size which includes the following :- (i) Taking out the entire unit from the window after unscrewing front cover, packing material, ply or any type of front cover. (ii) Servicing/cleaning the entire unit with elect blower and cleaning with collin or equivalent agent . (iii) Testing and refixing complete all as directed Note :- (i) Spare parts any reqd shall be measuread and paid separetely as supply only . (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the plants shall be handed over on daily basis through proper documentation . (iv) Penal charges @ Rs. 1000 per plant per day shall be charged for not following the schedule. (v) Through care / protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning . (vi) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost . (vii) Each service shall be measured and paid separetly as each job
Attending the daily complaints which includs the following (Complaint pertaints to ACs/ water coolers/ Refrigerator/ Deep freezer/ Desert coolers/ Voltage stabilizer) :- (i) Checking elect circuit, tightning of loose elect connection including internal circuit of plant and ensure the functioning of the plant. Note :- (i) For authentication complaints shall be fwd through telephone / SMS/ written post . (ii) The deployed tradesman shall have technical qualification in the field and necessary documentary proof shall be produced by the contractor . (iii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iv) For non adherance of complaints with in 24 Hrs penal charges @ Rs 1000 per complaint per day shall be charged
Supply only double shaft blower motor for window type AC of capacity 1.5/ 2 ton single phase, 230 Volt, 1500 RPM complete all as specified and as directed. Make : Crompton / Kirloskar suitable for AC of make Fedder Lloyd/ Blue star/ LG/ Carrier/ Samsung.
Taking out unserviceable sealed unit compressor from existing window type/ split type air conditioner of capacity 1.5 ton of any make and Supply and fixing new hermetically sealed unit compressor of existing type make Tosiba/ Carrier/ Kirloskar/ Tecumseh/LG as per existing make as approved by GE including cleaning & painting the base plate and charging of refrigerant R-22/ R-410 gas to obtain adequate cooling complete all as specified and as directed.
All as per item 4 here-in-before but of capacity 2.0 ton. NOTE for serial item No 4 & 5 : (i) Supply and charging of regrigerant gas shall be measured and paid separately (ii) New compressor shall be brought at site in original packing of manufacturer with complete details of compressor. (iii) New Compressor shall be procured from OEM's authorised dealer/ distributor. Invoice with test certificate shall be produced.
Supply only starting relay LT 85002 single phase 240 volts AC, 50 Hz, 20 Amps Make : Techno / Kirloskar.
Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp, AC1 rating 45 Amp complete all as specified and as directed. Make : L&T/ BCH/ C&S/ABB/Havells
All as per item 7 here-in- before but AC3 rating 32 Amp, AC1 rating 55 Amp.
All as per item 7 here-in- before but AC3 rating 40 Amp, AC1 rating 55 Amp three pole.
Supply only remote control hand set for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar and of cap 1.5/2 ton with required pencil cells complete all as specified and as directed.
Supply only 50 Mfd running capacitor of window/split type Air conditioner complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified & directed by Engineer-in-charge.
Supply and fix sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces after taking out old unserviceable sub main wiring complete by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 06 sqmm and one single core of 06 sqmm cable along with PVC conduit shall be considered as 1 running metre. (ii) cutting chases and PVC conduit will be measured and paid separately
Supply and fix sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces after taking out old unserviceable sub main wiring complete by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core of 10 sqmm cable along with PVC conduit shall be considered as 1 running metre. (ii) cutting chases and PVC conduit will be measured and paid separately
Supply only fan blade PVC suitable for window type AC complete . Make : LG/ Carrier/ Voltas / samsung/ fedder loyed
Supply & fixi in repair mild steel stand/ frame/ base support for window/Split type ACs 1.5/2 Ton/ desert coolers/ water coolers in various sizes made of MS angle iron 35x35x5mm or any other section conforming to Fe-410.0 or Fe-310.0 including necessary welding and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and as directed.
Supply only kit for window type AC, comprising cooling, condensing coil, blower motor (1.5 TR) and electrical accessories, testing complete all as specified and as directed. Make: Opel/ LG/ Voltas/ Viva.
Supply only front grill of window type AC with shutters (as per sample) complete all as specified and as directed.
Supply only thermostatic switch single phase 230 volt 50 Hz suitable for fedder Lloyd/ Bluestar/ Voltas/ Carrier/ LG/ Samsung window type air conditioner complete all as specified and as directed. Make : Indofoss/ Danfoss
Supply only starting capacitor of capacity exceeding 100Mfd and not exceeding 120Mfd in plastic container complete all as specified and as directed.Make :- Sharda/ Tibcon / Epcos.
All as per item 20 here-in- before but capacity 80 to100 Mfd. Make :- Sharda/ Tibcon / Epcos.
Supply only capacitor oil based 50 mfd complete for window/split AC 1/1.5/2 TR cap Make :- Sharda/ Tibcon / Epcos.
All as per item 22 here-in- before but but 36 mfd. complete for window/split AC 1/1.5/2 TR cap Make :- Sharda/ Tibcon / Epcos.
All as per item 22 here-in- before but 120-150 mfd. complete for window AC 1/1.5/2 TR cap Make :- Sharda/ Tibcon / Epcos.
Carrying out pressure leak test by Nitrogen gas pressure for detecting the leakage in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing flushing out by nitrogen gas, vacummnation and M&L charging of refrigerant gas R-22 into the system for 1.5/2 TR capacity split/window type AC including transporting & carrying Tools & Plants required at site complete all as specified and as directed. Note :- Refrigerrant gas R-22 will be measured and paid under relevant item
Supply & charging (Topping up) the AC unit of window/split type/ refrigerators/ water coolers/ deep freezer etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed.
Supply only charging R-32 gas for inverter type split AC hot cold type complete all as specified and as directed.
Supply only 1/2'' and 1/4'' reverse valve for split AC valve complete all as specified and as directed.Make : Carrier / Voltas/ LG
Supply only of material for providing insulation on and around suction and discharge copper tube of size 3/8"and 5/8" with 6mm thick flexible thermocoal heat resistance for split type AC complete all as specified and as directed.
Supply only of 5/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed. Note : 1 meter of 5/8" dia copper pipe, 1 meter of 3/8" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
All as per item 30 here-in- before but size 1/2” and 1/4” dia, Note : 1 meter of 1/2" copper pipe, 1 meter of 1/4" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
Supply only 3 core copper wire size 4 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.Make : Finolex/ Rallison/ L&T/ Grandlay
Supply only swing motor for 1.5 TR /2 TR split AC indoor unit for any type and make complete all as specified and as directed. Make: LG / Carrier / Voltas
Supply only cooling coil motor 1/35 HP, three speed, single phase, 230 volt 50 Hz suitable for split AC 1.5/2 ton complete all as specified and as directed. Make: Carrier/LG/Samsung/Daikin.
Supply only FRLSH PVC insulation & PVC sheathed multi core cable 3 core of size 0.75 Sqmm no of standard dia 24/0.2 (no/mm) with electrolytic grade/ annealed copper conductor suitable upto 1100 volts grade conforming / generally conforming to IS 694 Note : Each core of the wire is in different colour of identification. make havells, polycab, grandlay, complete all as specified and as directed.
Taking down of existing window type AC from its location and refixing in new location after overhauling by oiling & cleaning by liquid soap and testing after installtion complete all as specified and as directed.
Supply only suction valve size 3/8" for 1.5/ 2 TR split AC complete all as specified and as directed.Make:- BAP / TAK Cassel
Supply only discharge valve size 1/2" for 1.5/ 2 TR split AC complete all as specified and as directed.Make:- BAP / TAK Cassel
Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 1.5 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay condensing/ outdoor motor with blade complete all as specified and as directed.Make :- Opel/ Accent/ Skoda/ LG/ Carrier
Supply and fix in renewal defective indoor unit 1.5 TR inverter, Antibacterial - coating dust-filter, Air -Purifier type, hot cold type, power source corded electic brand voltas modal No185V-JZJ(R32) make voltas split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Note : Supply and charging refrigerant gas as required shall be measured and paid for separately.
All as per item 40 here-in- before but 2 ton indoor unit
Disconnecting electric connection from defective blower motor and taking out from window type/ split AC outdoor unit capacity 1.5/2 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit, PCB, visual eye damp plates, unserviceable cordless electronic remote control and fixing the new wiring, cordless electronic remote control, PCB, visual eye damp plate in place of damaged items of split AC of capacity 1.5 TR/ 2TR including matching the existing system all as specified and as directed. Make of AC & remote: Carrier/ LG/ Hi series/ Samsung.
Periodical maint of water cooler of capacity 40/80,60/120,150 ltr of any make any size , Regrigerator 165 / 180 / 240 / 300 / 310 L, Deep freezer 100/300/625L, voltage stabilizer 0.5 KVA to 5 KAV which includes the following :- (i) Descaling the water cooler by suitable chemical (ii) Servicing/cleaning the entire unit with elect blower. (iii) Testing and refixing complete all as directed Note :- (i) Spare parts any reqd shall be measuread and paid separetely as supply only . (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the plants shall be handed over on daily basis through proper documentation . (iv) Penal charges @ Rs. 1000 per plant per day shall be charged for not following the schedule. (v) Through care / protection of elect circuit plate shall be kept to avoid any kind of damage while servicing/ cleaning . (vi) Each service shall be measured and paid separetly as each job
S&F 25 mm bore GI tube medium grade, galvanized with all fitting like elbows, tees, socket etc and fixed to walls, ceiling or laid in floors/ wall after taking down old tubing complete all as specified and as directed. Make : Jindal / Swastic / TATA.
Supply & fixing in renewal stop valve cast copper alloy (weight not less than 400g) ISI marked, screwed down, high pressure, 15 mm bore complete all as specified and as directed.
Material and labour for renewal PTMT of PVC ball valve for 15 mm bore dia pipe with 01 No. polythene ball and aluminum rod both ends screwed with check nut and rubber washer complete all as specified and as directed. Make : Paryag / Aristo / Sicco.
Supply only condenser fan motor 1/32 HP single phase 50 HZ, 230 volts with blade suitable for water coolers of capacity 40/80L complete all as specified and as directed. Make : Sidwal / Voltas / Blue Star / USHA.
Supply only condenser fan motor 1/10 HP single phase 50 HZ, 230 volts with blade suitable for water coolers of capacity 60/120L complete all as specified and as directed. Make : Sidwal / Voltas / Blue Star / USHA.
Material and labour preparation of old painted surfaces of water cooler capacity 40/80L by scraping, necessary denting, cutting, welding, Supply and fixing in repair PGI sheet of existing thickness and area not exceeding 0.2sqm each and spray painting with two coats of synthetic enamel paint of approved tint/ colour over a coat of red oxide primer. Before painting it should be cleaned with emery paper without disturbing the components & wiring etc complete all as specified and as directed.
All as per item 50 here-in- before but for capacity 60/120L
Material and labour renewal of brass ball valve for 15 mm bore dia pipe with 01 No. polythene ball and aluminum rod both ends screwed with check nut and rubber washer complete all as specified and as directed.
Supply only chromium plated brass water tap of size not exceeding 15mm (push /lift type) complete all as specified and as directed. Make : Seiko / Viking / Ess Ess.
Supply anf fx in renewal steel top cover with rubber gasket & accessories like hinges etc, for water cooler of capacity not exceeding 150 litre matching with existing body colour complete all as specified and as directed.
Material and labor detecting any leakage from cooling and condensing coil of water cooler capacity 40/80L of any make with the help of high pressure nitrogen gas and repairing the leakage by welding / brazing of cooling and condensing coils including renewal of filter, capillary tube and testing the unit complete all as specified and as directed. Note for item No 55 to 58:- Supply & charging of refrigerant gas R-22/R-134 will be measured and paid for separately
All as per item 55 here-in- before but for 60/120L capacity.
All as per item 55 here-in- before but refrigerator for 165/180/240/300/310 Ltr of any make
All as per item 55 here-in- before but deep freezer for 300/625 Ltr of any make
Taking down old unserviceable compressor of any make/ model from water coolers cap 40/80L of Make : Sidwal/ Voltas/ Usha/ Blue star & Supply and fixing new sealed compressor, replacing liquid line filter and capillary tube suitable for refrigerant with necessary brazing work, flushing the cooling including charging of refrigerant R-22/R-134 to obtain adequate cooling complete all as specified and as directed. Make : Kirloskar or Tecumseh
All as per item 59 here-in- before but for capacity of water coolers 60/120L compressor Model No. 2612. Make : Kirloskar or Tecumseh.
Material and labour repair inner water tank and replace with new water tank of 40/80 ltr cooling capacity including all outer side puffing etc all as directed by EIC.
All as per item 59 here-in- before but for deep freezer of capacity 100/300/325 L compressor Model No. 2425. Make : Kirloskar/Tecumseh/LG /Copeland.
All as per item 59 here-in- before but for refrigerator 165/180/240/300/310 Ltr of any make. Make of Comressor: Godrej/Usha/Tecumseh/LG/Copeland
Supply only starting capacitor 40/60 mfd for water cooler 40/80 L, 60/120 L complete all as specified and as directed. Make : Sharda/ Asian/ Unistar/ Tesla/ Epcos
Supply only running capacitor 10 mfd for water cooler 40/80 L, 60/120 L complete all as specified and as directed. Make : Sharda/ Asian/ Unistar/ Tesla/ Epcos
Supply only starting relay LT 85002 complete all as specified and as directed.
Supply only starting relay OLP No. 4440 complete all as specified and as directed.
Supply only rubber waste pipe /drain pipe with clamps suitable for water cooler any capacity complete all as specified and as directed.
Material and labour base standing support comprising frame of size equal to length & width of water cooler and height of legs (04 Nos) 1 feet each , including painting with two coat of synthetic, enamel paint over a coat of red oxide primer made out of angle iron of size 35mm x 35mm x 6mm suitable for 40/80L and 60/120 water cooler of any make complete all as specified and as directed.
Supply only door gasket suitable for 300/625 ltr deep freezer doors complete all as specified and as directed.
Supply and fix in renewal, condensing coil for water cooler capacity 40/80L of any make and charging refrigerant R-134/R-22 to obtain adequate cooling complete all as specified and as directed.
All as per item 71 here-in-before but 60/120 ltr capacity.
Supply and fix in renewal, front panel for water cooler capacity 40/80 and 60/120 L of any make made of 22 gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in renewal, condensing coil for refrigerator 160L capacity including disconnecting condensing coil from refrigerator, Nitrogen Pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified and as directed.
Supply and fixing in renewal, condensing coil for refrigerator 286/300 L capacity including disconnecting condensing coil from refrigerator, Nitrogen pressure testing and flushing out the system and charging of refrigerant gas up to required cooling level complete all as specified and as directed.
Material and labour preparation of old painted surfaces of refrigerator 286/300 L capacity including necessary denting cutting and welding S&F PGI sheet of existing thickness and area not exceeding 0.2sqm each and preparation of surface, filling putty, rubbing to make the surface smooth and spray painting with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer and without disturbing the components & wiring etc complete all as specified and as directed.
Supply only starting relay for refrigerator of any capacity complete all as specified and as directed.
Supply only over load protector for refrigerator of any capacity complete all as specified and as directed.
Supply only thermostat defrost type ISI marked for refrigerator of any capacity complete all as specified and as directed.
Supply only freezer door for refrigerator of capacity 286/300 L completeall as specified and as directed.
Supply only defrost tray for refrigerator of any capacity complete all as specified and as directed.
Supply only gas filter flair type ¾” x ½” flare for refrigerator of any capacity complete all as specified and as directed.
Supply and fix in renewal, copper capillary for refrigerator of any capacity all as directed by Engineer-in-Charge.
Dismantling the worn out base of fan motor of water coolers and supply & fixing new base for fan motor made out of MS sheet of 16 gauge and size 450mm x 450mm complete all as specified and as directed.
Supply and fix in renewal, plastic front cover inner liner complete with fixture accessories such as bottle strip, egg tray cheese tray etc suitable for any capacity refrigerator complete all as specified and as directed.
Material and labour providing angle iron stand for water cooler of suitable size made out of 35mm x 35mm x 6mm size MS angle iron including necessary welding and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of surfaces complete all as specified and as directed.
Supply only starting relay ISI marked for deep freezer of capacity upto 625 L complete all as specified and as directed.
Supply only over load protector ISI marked for deep freezer of capacity upto 625 L complete all as specified and as directed.
Supplyonly thermostat ISI marked for deep freezer of capacity upto 625 L complete all as specified and as directed.
Supply only running capacitor 36 mfd ISI marked for deep freezer of capacity upto 625 L complete all as specified and as directed. Make :- Sharda/ Asian/ Unistar/ Tesla/ Epcos.
Supply only starting capacitor 60-80 mfd ISI marked for deep freezer of capacity upto 625L complete Make :- Sharda/ Asian/ Unistar/ Tesla/ Epcos.
Supply only handle for door of deep freezer in place of broken door handle complete all as specified and as directed.
Supply only capacitor of 3.15 mfd ISI marked for blower motor of water cooler any make and any capacity complete all as specified and as directed.
Supply and fix in replacement, freezer assembly alongwith evaporative coil for refrigerator of any capacity by disconnecting cooling coil from refrigerator, Nitrogen pressure testing and flushing out the system and charging of refrigerant gas upto required cooling level complete all as specified and as directed.
Supply only , top plug 3 pin 5 Amp in white colour complete all as specified and as directed. Make : SSK / CONA / FINE.
Supply only , top plug 3 pin 15 Amp in white colour complete all as specified and as directed. Make : SSK / CONA / FINE.
Supply & fix in replacement cable FRLSH PVC insulation & PVC sheathed multi two core of size 0.5 Sqmm no of standard dia 16/0.2 (no/mm) with electrolytic grade/ annealed copper conductor suitable upto 1100 volts grade conforming / generally conforming to IS 694 complete all as specified and directed. Note each core of the eire is in different colour of identification. make havells, polycab, grandlay cut to pieces all as required, drawn into conduit/pipe fixed to wall or pole complete
Supply & fix in replacement cable FRLSH PVC insulation & PVC sheathed multi three core of size 2.5 Sqmm no of standard dia 50/0.25 (no/mm) with electrolytic grade/ annealed copper conductor suitable upto 1100 volts grade conforming / generally conforming to IS 694 complete all as specified and directed. Note each core of the eire is in different colour of identification. make havells, polycab, grandlay cut to pieces all as required, drawn into conduit/pipe fixed to wall or pole complete.
Supply and charging gas R-134 for top up for regrigerator of any make and capacity complete all as specified and as directed.
Supply and charging R-600 for deep regrigerator of any make and capacity complete all as specified and as directed.
Supply and charging R-134 A/R-600 for water cooler of any make and capacity complete all as spefified and directed.
Strip opening of voltage stablizers after unscrewing nut, bolts, srew etc, any make any type of 1 KVA for undertaking following repairs,including rerassembling, testing complete . NOTE : Spare parts reqd shall be measured and paid separately under relevant items :
(a) Taking out burnt winding after carefully strip opening stamping etc rewinding with super enammeld copper wire of gauge matching with manufactrur design both in turns and guage , varnishing , provision of insulating material reassembling , refixing , testing complete
(b) Transformer 1 KVA copper wound complete with terminal plate 3 step( + - ) up and down, single phase 230V nominal operating voltage range 180V to 280V suitable for 1 KVA
( c) Contactor Single phase 230V CTR ,25A, type MR 11W . Cat No CS94176, of L&T or equivalent suitable for 1 KVA stbilizer Make : AE/V Guard/ Ranutrol/ABB/ Legrand/L&T ,BCH
(d) Standard PCB board suitable for 1 KVA , 230V AC stabilizer of Make V Guard/ AE
(e) Terminal plate 8 way with brass contacts complete Note:- Labour element for (a to e) shall be part of Item No 102
Strip opening of voltage stablizers after unscrewing nut, bolts, srew etc, any make any type of 2/3 KVA for undertaking following repairs and rerassembling, testing complete NOTE : Spare parts reqd shall be measured and paid separately under relevant items :
(a) Taking out burnt winding after carefully strip opening stamping etc rewinding with super enammeld copper wire of gauge matching with manufactrur design both in turns and guage , varnishing , provision of insulating material reassembling , refixing , testing complete
(b) Transformer 2/3 KVA copper wound complete with terminal plate 3 step( + - ) up and down, single phase 230V nominal operating voltage range 180V to 280V
( c) Contactor Single phase 230V CTR ,25A, type MR 11W . Cat No CS94176, of L&T or equivalent suitable for 2/3 KVA stbilizer Make : AE/V Guard/ Ranutrol/ABB/Legrand/L&T ,BCH
(d) Standard PCB board suitable for 2/3 KVA , 230V AC stabilizer of Make V Guard/ AE
(e) Terminal plate 8 way with brass contacts complete Note:- Labour element for (a to e) shall be part of Item No 103
Strip opening of voltage stablizers after unscrewing nut, bolts, srew etc, any make any type of 4 KVA for undertaking following repairs and rerassembling, testing complete . Spare parts reqd shall be measured and paid separately under relevant items :
(a) Taking out burnt winding after carefully strip opening stamping etc rewinding with super enammeld copper wire of gauge matching with manufactrur design both in turns and guage , varnishing , provision of insulating material reassembling , refixing , testing complete
(b) Transformer 4 KVA copper wound complete with terminal plate 3 step( + - ) up and down, single phase 230V nominal operating voltage range 180V to 280V
( c) Contactor Single phase 230V CTR ,25A, type MR 11W . Cat No CS94176, of L&T or equivalent suitable for 4 KVA stbilizer Make : AE/V Guard/ Ranutrol/ABB/Legrand/L&T ,BCH
(d) Standard PCB board suitable for 4 KVA , 230V AC stabilizer of Make V Guard/ AE
(e) Terminal plate 8 way with brass contacts complete Note:- Labour element for (a to e) shall be part of Item No 103
Strip opening of voltage stablizers after unscrewing nut, bolts, srew etc, any make any type of 5 KVA for undertaking following repairs and rerassembling, testing complete . Spare parts reqd shall be measured and paid separately under relevant items :
(a) Taking out burnt winding after carefully strip opening stamping etc rewinding with super enammeld copper wire of gauge matching with manufactrur design both in turns and guage , varnishing , provision of insulating material reassembling , refixing , testing complete
(b) Transformer 5 KVA copper wound complete with terminal plate 3 step( + - ) up and down, single phase 230V nominal operating voltage range 180V to 280V
( c) Contactor Single phase 230V CTR ,25A, type MR 11W . Cat No CS94176, of L&T or equivalent suitable for 5 KVA stbilizer Make : AE/V Guard/ Ranutrol/ABB/Legrand/L&T ,BCH
(d) Standard PCB board suitable for 5 KVA , 230V AC stabilizer of Make V Guard/ AE
(e) Terminal plate 8 way with brass contacts complete Note:- Labour element for (a to e) shall be part of Item No 103
Taking down old unserviceable voltmeter and supply & fixing new voltmeter 0 to 300 volts range 95x95mm square complete all as specified and as directed. Make : AE/ Mavi/ Havells/Pricol
Taking down old unserviceable Ammeter 0-30 Amps and S&F new Ammeter 0-30 Amp round type 95mm dia complete all as specified and as directed. Make : AE/ Mavi/ Havells/Pricol
Periodical maint of desert cooler of any make any size which includs the following :-(i) Removing old Khas Khas pad and fix new Khas khas pad (ii) Servicing/cleaning the entire unit with elect blower. (iii) Testing and refixing complete all as directed Note :- (i) Spare parts any reqd shall be measuread and paid separetely as supply only . (ii) Labour element for fixing of any defective spare part shall be part of the item (iii) All the plants shall be handed over on daily basis through proper documentation . (iv) Penal charges @ 200 per plant per day shall be charged for not following the schedule. (v) Through care / protection of elect circuit plate shall be kept to avoid any kind of damage while servicing/ cleaning . (vi) Each service shall be measured and paid separetly as each job
Supply and fix in renewal submersible FEDUS WATER PUMP 14 WATT for desert cooler air cooler is a powerful and heavy duty pump of voltage 165-250 Ac/ 50Hz power 14hz 1 phase output : 750Hz max: 1.2 M (3.9 feet approx ) weight of pump 250 grams complete all as specified and as directed. . Make: FEDUS, Dingo, Zoom
Supply and fix in renewal PVC water pipe with PVC distributor & PVC elbow for desert cooler complete all as specified and as directed.
Supply and fix in renewal desert cooler fan motor of shaft height 48.40mm 1325mtr cube per hour stack height 21.9mm output watts 107, copper wound, single phase, 50 Hz, 230 volts with blade, motor holding clips/ brackets etc complete all as specified and as directed Make : KHAITAN / BAJAJ / CROMPTON GREAVES.
Material and labour testing water leakage of desert cooler bottom of tank and repairing and replacing the damaged rusted bottom with bottom tank dimension W x D x H 1200mm x 725mm x 250mm made by 0.8mm GI sheet all four corners of bottom shall be completely welded including preparation/ scraping of old painted surface of desert cooler of any make approx dimension 2’x2’x3’ and repainting of steel sheets of the cooler inside & outside with two coats of synthetic enamel paint (superior Ist quality) including front grill with black paint and applying anti corrosive black paint inside the bottom of water tank including removing and refixing at site complete all as specified and as directed.
Supply and fixing in renewal capacitor of 4 mfd ISI marked for motor of desert cooler complete all as specified and as directed. Make :- Sharda / Asian / Unistar / Tesla / Epcos.
Periodical maintenance of AC's (Hot & Cold) of capacity 8.5 Ton ductable AC- 31 Nos. ACs of make LG, 3 ton pillar type 02 Nos of ACs of make LG and 3 ton cassette type AC - 33 Nos. of make LG & 4 Nos of Hitachi , 5.0 ton ductable -17 Nos of make Amtrex by disconnecting of indoor and outdoor unit at site and refixing the same after repair/replacement of the defective spare parts (spare parts where required to be replaced shall be measured and paid separetly as supply only). Servicing of the ducts, drain pipe, cooling coil, condensing coil and adjusting the duct slope for free flow of drain water, testing of the complete set of Hot/Cold at desired temperature complete all as specified and as directed. Note:- (i) Gas charging, spare parts shall be measured and paid for separately under respective items here-in-after. (ii) The contractor shall provide only the experienced and qualified staff for handling the sensitive works. (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging , leak testing etc (iii) All the plants shall be handed over on daily basis through proper documentation . (iv) Penal charges @ 1000 per plant per day shall be charged for not following the schedule. (v) Through care / protection of PCB plate shall be kept to avoid any kind of damage while servicing/ cleaning . (vi) Each service shall be measured and paid separetly as each job
Supply only of material for providing insulation on and around suction and discharge copper tube of size 3/8"and 5/8" with 6mm thick flexible thermocoal heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mm dia complete all as specified and directed.
Supply only of AC contactor three phase of capacity 25 Amp suitable for pillar type AC-3 TR complete all as specified and directed.Make : L&T/BCH/ABB
All as per serial item No 136 hereinbefore but capacity 32 Amp suitable for 5 TR capacity ductable type AC complete
All as per serial item No 136 hereinbefore but capacity 40 Amp suitable for LG 8.5 TR capacity ductable type AC complete
Supply only liquid line drier filter suitable for 8.5 ton ductale AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note:- Refrigerent will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
All as per item 139 here-in-before but for 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
All as per item 139 here-in-before but for 3 TR pillar /cassette type AC.
Supply only of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
All as per item 142 here-in-before but for 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
All as per item 142 here-in-before but for 3 TR pillar / cassette type AC.
Supply only of low / high pressure switch for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
All as per item 145 here-in-before but for 5 TR/3 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
Taking out unserviceable sealed unit compressor from cassttee/ pillar type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and Supply and fixing new scroll compressor of capacity 3 ton including charging of refrigerant gas R-22/ R-410 upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland NOTE : Supply and charging refrigerent gas will be measured and paid separately under relavent itmes
All as per item 147 here-in-before but three phase compressor of capacity 4.25 TR suitable for 8.5 TR suitalbe for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
All as per item 147 here-in-before but three phase compressor of capacity 5 TR suitalbe for 5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
Carrying out pressure leak test of 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed.
M&L for MCB single pole 240 volts 5 to 30 amps asper site requirment , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), biconnect upper and lower terminals , integrated label holder to ensure circuit identification, Make : Hager,Legrand , Schinder (Acti-9)/Havells
Supply and fix in replacement MCB double pole 240 volts any rating from 5 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make : Hager,Legrand , Schinder (Acti-9)/Havells
Supply & charging (Topping up) the ductable split type AC etc with refrigerant gas R-410 in required quantity for desired cooling complete all as specified and as directed.
Supply only thermal relay 15 A to 30 Amps, 415 Volt, single phase suitable for pillar/ cassette type AC of 3 TR/5 TR/8.5 TR capacity as per sample complete all as specified and as directed. Make : LG / Hitech/Indo Asian/L&T/Tecumseh.
Supply only PCB (circuit plate) of out-door unit of 8.5 TR ductable split AC complete all as specified and as directed.
All as per item 155 here-in-before but for pillar /ductable/ casette / any type AC 5.0 TR
All as per item 155 here-in-before but for pillar /ductable/ casette / any type AC 3 TR.
Supply only PCB (circuit plate) of in-door unit of 8.5 TR ductable split AC complete all as specified and as directed.
All as per item 158 here-in-before but for pillar /ductable/ casette / any type AC 5.0 TR
All as per item 158 here-in-before but for pillar /ductable/ casette / any type AC 3 TR.
Supply only single phase preventor, 230 volt, 50 HZ, AC supply complete all as specified and as directed. Make : L&T / Seimens / Hagger.
Supply only heating strip/coil capacity 3 KW suitable for 8.5 TR ductable split AC complete .
Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity 3 Ton complete all as specified and as directed.
Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity 5Ton complete all as specified and as directed.
Supply only indoor blower motor for cooling coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 8.5 TR / TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only indoor blower motor for cooling coil 1/3 HP, 230 volt, 930 RPM including blower suitable for pillar/ cassette type AC of 3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only indoor blower motor for cooling coil 1/3 HP, 230 volt, 930 RPM including blower suitable for pillar/ cassette type AC of 5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only outdoor fan motor suitable for small shaft condensing coil 1/3 HP, 230 volt, 930 RPM including blade suitable for ductable AC of 8.5 TR / 5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only outdoor fan motor suitable for small shaft condensing coil 1/3 HP, 230 volt, 930 RPM including blade suitable for pillar/ cassettte AC of 3 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only outdoor fan motor suitable for small shaft condensing coil 1/3 HP, 230 volt, 930 RPM including blade suitable for pillar/ cassettte AC of 5TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
Supply only wall mount remote kit with wire and complete assembly suitable for ductable AC of 3/8.5 TR complete all as specified and directed
Supply only drain pipe of PVC medium grade of 25mm with all accessories like elbow, socket, tees etc complete all as specified and as directed.
Supply only three phase electronic timer (415 Volt) for outdoor unit suitable for 8.5 TR ductable AC complete
Supply and fix, Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in trench complete all as specified and directed.
Supply and fix, Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in trench complete all as specified and directed.
Supply Laying, jointing and testing LT underground electric cable XLPE insulated PVC sheathed armoured heavy duty 1100 volts grade with multistranded aluminum conductor of cross sectional area 25 Sqmm 3.5 Core laid in ducts through pipe on floor or road with suitable arrangement including taking down existing unserviceable cable complete all as specified and directed
Supply only starter 3 phase ,415V, 40A suitable for ductable AC of cap 5 TR complete all as specified and as directed. Make: L&T/BCH/ABB
Disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 3/8 / 5/5 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
Taking out of defective wiring of indoor/ outdoor unit of PCB, visual eye damp plates, fixing the new wiring in place of damaged items of capacity of AC 3/8 / 5/5 TR including matching the existing system all as specified and as directed. Make of AC : LG/ Hitachi/ Amtrex.
Material and labour point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
M/S Trilok chand sharma
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .