| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | ₹19.1 L Quoted ₹21.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹22.2 L+₹70,021 (3.26%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹22.2 L+₹70,021 (3.26%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹24.4 L+₹2.9 L (13.6%)Rejected-Finance | ₹24.4 L+₹2.9 L (13.6%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹26.4 L+₹4.9 L (22.9%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | ₹26.4 L+₹4.9 L (22.9%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹32.0 L+₹10.5 L (48.7%)Rejected-Finance | ₹32.0 L+₹10.5 L (48.7%) | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Jul 2024, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin 305601
DAY TO DAY MAINTS OF INTERNAL ELECTRIFICATION INCLUDING ELECTRIC METERS, GEYSERS AND CEILING FANS/EXHAUST FAN IN MD AND OTM ACCN AT GE NASIRABAD
2024_MES_659962_1
8456/E8
Open Tender
Civil Works
Works
335 days
GE NASIRABAD
MES Contractor enlisted as Class D and above and category b I Low tension works upto 1100 Volts having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to
6 documents required · 6 mandatory
₹500
Yes
₹90,000
Yes
9 Sept 2024
14 Jun 2024
10 Jul 2024
14 Jun 2024
8 Jul 2024
26 Jun 2024
14 Jun 2024 - 20 Jun 2024
Amount
Taking down old Ceiling / Wall / Exhaust fan of any sweep, dismantling blades for rewinding complete all as specified and directed by Engr-in-Charge.
Dismantling blades carefully and cutting down and removing old copper wire winding of following size and type of fan of any make and rewinding with new super enamelled copper wire of existing gauge as per old copper winding including providing insulation by varnishing (golden), cleaning, oiling, greasing etc and assemble all the parts complete and testing in E/M store yard and hanging ceiling/wall/exhaust fans connecting up complete all as specified and directed by Engr-in-Charge. :- Note :- (i)The super enamelled winding wire shall be any one make of Devidayal / Chetak / National of appropriate gauge as directed by Engineer-in-Charge. (ii) Any unserviceable parts required for replacement shall be measured and paid separately under respective item of 'BOQ' as supply only.
All as per Item No-2.00 above but Ceiling fan of size 1200mm sweep
All as per Item No-2.00 above but Ceiling fan of size 1400mm sweep
All as per Item No-2.00 above but Ceiling fan of size 1500mm sweep
All as per Item No-2.00 above but Wall fan of size 400mm sweep
All as per Item No-2.00 above but Wall fan of size 600mm sweep
All as per Item No-2.00 above but Exhaust fan of size 250mm sweep
All as per Item No-2.00 above but Exhaust fan of size 300mm sweep
All as per Item No-2.00 above but Exhaust fan of size 380/400mm sweep
All as per Item No-2.00 above but Exhaust fan of size 450mm sweep
Taking down carefully old ceiling fan/exhaust fan of following sizes from ceiling/wall after disconnecting the electric cable including dismantling carefully all parts of ceiling fan/exhaust fan and refixing the same to old or new location after cleaning, oiling, greasing and testing and making serviceable complete all as specified and directed by Engr-in-Charge. :- Note : Any unserviceable parts required for replacement shall be measured and paid separately under respective item of 'BOQ' as supply only.
All as per Item No-3.00 above but Ceiling fan of size 1200mm/1400mm/1500mm sweep.
All as per Item No-3.00 above but Exhaust fan of size 250mm/300mm/380mm/400mm /450mm sweep
Supply only against Ser item No 1.00 & 2.00 above here-in-before ball bearing double Z type, both end sealed suitable for ceiling/ exhaust fans of different sizes complete all as specified and directed by Engr-in-Charge. MAKE:- NBC/TATA/SKF
All as per Item No-4.00 above but Ball bearing No 6201
All as per Item No-4.00 above but Ball bearing No 6202
All as per Item No-4.00 above but Ball bearing No 6203
All as per Item No-4.00 above but Ball bearing No 6204
Supply only against Ser item No 1.00 & 2.00 above here-in-before gun metal bush of suitable size for 1200mm/1400mm/1500mm sweep of ceiling fans complete all as specified and directed by Engr-in-Charge.
Supply only against Ser item No 1.00 & 2.00 above here-in-before rotar shaft for following sizes of ceiling / exhaust fan complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-6.00 above but Ceiling fan of size 1200mm/1400mm/1500mm sweep.
All as per Item No-6.00 above but Exhaust fan of size 250/300mm sweep
All as per Item No-6.00 above butExhaust fan of size 380mm/400mm /450mm sweep
Supply only against Ser item No 1.00 & 2.00 above here-in-before shackle assembly complete with rubber reel, brackets 3 X nuts & bolts with quarter pin suitable for fixing ceiling fan of any type sweep and make complete all as specified and directed by Engr-in-Charge.
Supply only against Ser item No 1.00 & 2.00 above here-in-before three core copper flexible wire of size 23/0.0076 PVC insulated 1100 Volts, for ceiling fan / Exhaust fan complete all as specified and directed by Engr-in-Charge. Make :- Havells / Plaza / Finolex.
Supply only against Ser item No 1.00 & 2.00 above here-in-before capacitor of following capacity, paper insulated with PVC/ aluminium body, ISI marked complete all as specified and directed by Engr-in-Charge. Make :- Havells /Bajaj / AMCAP.
All as per Item No-9.00 above but 2.5 Mfd
All as per Item No-9.00 above but 3.15 Mfd
All as per Item No-9.00 above but 4.00 Mfd
Taking out old unserviceable capacitor and S & F capacitor of 2.5 Mfd capacity, paper insulated with PVC/ aluminium body, ISI marked complete all as specified and directed by Engr-in-Charge. Make :- Havells /Bajaj / AMCAP.
Supply only against Ser item No 1.00 & 2.00 above here-in-before capacitor holding clamp suitable for any type of rod complete all as specified and directed by Engr-in-Charge.
S & F in repair mild steel clamp made out of flat iron of size 32 x 6mm of suitable length with nuts, bolts & washer for hanging of ceiling fan (any type, sweep and make) complete all as specified and directed by Engr-in-Charge.
S & F in repair plastic canopy suitable for ceiling fan of 1200mm/1400mm/1500mm sweep complete all as specified and directed by Engr-in-Charge. NOTE:- Make match with existing provisions
S & F in repair blade made of aluminium suitable for ceiling fan of 1200mm/1400mm/1500mm sweep complete all as specified and directed by Engr-in-Charge. NOTE:- Make match with existing provisions
S&F in repair stepped type (switch type) electronic ceiling fan regulator, flush type, AC, 230 volts complete all as specified and directed by Engr-in-Charge.
S & F in repair 15mm dia down rod made out of high density mild steel, 30cm long including drilling the hole for split pin and duly painted same as existing colour of fan complete all as specified and directed by Engr-in-Charge.
S & F in repair 15mm dia down rod made out of high density mild steel, 45cm long including drilling the hole for split pin and duly painted same as existing colour of fan complete all as specified and directed by Engr-in-Charge.
S & F in repair exhaust fan louvers for following size complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-18.00 above but 300/380 mm Sweep
All as per Item No-18.00 above but 450 mm Sweep
M & L for painting of ceiling fan of any sweep complete in situ with one coat of synthetic enamel white paint by spray painting including filling cavities with filler after cleaning of dust etc complete all as specified and directed by Engr-in-Charge.
M & L for painting of exhaust fan of any sweep complete in situ with one coat of synthetic enamel black / grey paint by spray painting including filling cavities with filler after cleaning of dust etc complete all as specified and directed by Engr-in-Charge.
S&F switch in repair piano flush type 5/6 amps, single pole one way 240 volts, 50Hz, AC, ISI marked complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair socket out let 2 in 1,multipurpose 3 pin 5/6 Amp flush type, 240 volts, AC complete all, as specified & directed. Make : Cona / SSK / Havells
S&F in repair socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete all, as specified & directed. Make : Cona / SSK / Havells
S&F in repair switch socket combination 2 in 1, 3 Pin 5/6 Amp flush type, 230 Volt AC complete all as specified & directed. Make : Cona / SSK / Havells
S&F in repair socket out let 2 in 1,multipurpose 3 pin 15/16 Amp, 230 Volts, AC< flush type ISI marked complete all, as specified & directed. Make : Cona / SSK / Havells
S&F in repair bell push piano flush button type 5 Amp, 240 Volt, 50Hz, AC, ISI marked complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair ceiling rose surface bakelite, 3 terminals, 63.5 x 17 mm complete all as specified & directed. Make : Cona / SSK / Havells
S&F in repair bell ding dong type AC 240 volt complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair modular switch 1 way 6/10 Amp, 1 moudle, 230 Volt, AC 50Hz complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair modular switch 1 way 15/16 Amp, 1 moudle, 230 Volt, AC 50Hz complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair modular socket 15/16 Amp, 2/3 pin combined 2 module, 230 Volt, AC, 50 Hz complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair modular socket 5/6 Amp, 2/3 pin combined 2 module, 230 Volt, AC, 50 Hz complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair modular ceiling fan regulator, AC 120W, 2 moudle complete all as specified and directed by Engr-in-Charge. Make: Cona / SSK / Havells
S & F in repair top plug three pin 15 Amp complete all as specified and directed by Engr-in-Charge. Make : Cona/ SSK/ Havells
S & F in repair lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. Make : Cona / SSK / Havells
S&F in repair LED driver suitable for 2x2', 36 W LED light fitting, 240 volts. 50 Hz complete all as specified and directed by Engr-in-Charge. MAKE: Bajaj / Wipro / CG / Philips / Havells as approved by GE.
S&F in repair single core 1.5 sqmm PVC insulated and unsheathed stranded copper conductor complete all as specified and directed by Engr-in-Charge.
S&F in repair single core 2.5 sqmm PVC insulated and unsheathed stranded copper conductor complete all as specified and directed by Engr-in-Charge.
S&F in repair single core 4 sqmm PVC insulated and unsheathed stranded copper conductor complete all as specified and directed by Engr-in-Charge.
S&F in repair MCB single pole 240 volt 10 KA breaking capacity, 6 to 32 Amp conforming to IS 8828 of 1996, Curve 'C' including connection with suitable size aluminium lugs complete all as specified and directed by Engr-in-Charge. Make : Legrand/ Siemens/ Schneider
S&F in repair MCB single pole and neutral 240 Volt 10 KA breaking capacity, 25 to 32 amp conforming to IS 8828 of 1996, Curve 'C' including connection with suitable size aluminium lugs complete all as specified and directed by Engr-in-Charge. Make : Legrand/ Siemens/ Schneider
M&L in repair software support and sim charges including software hosting, software AMC, GPRS Charges, RF Network monitoring and troubleshooting and repair/replacement of meter/DCU with manufacturing defect for AMR meters complete all as speicifed and directed by Engr-in-Charge.
S&F in repair LED tube light fitting in acrylic linear tube (1x 18 watt),230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S & F in repair LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in repair testing and commissioning energy saving street light luminaire 25/30/35/36 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by Engr-in-Charge.
S&F in repair street light bracket made of GI pipe, fixed with two nos of clamp , nut and bolts for fixing of street light complete all as specified and directed by Engr-in-Charge.
S & F in repairs heating element round / triangle base including rubber ring, washer, holding clamps and nuts of following capacity complete all as specified and directed by Engr-in-Charge. Make :- BAJAJ / RECOLD / THEETA or any other ISI marked as approved by GE.
All as per Item No-49.00 above but 1.50 KW capacity
All as per Item No-49.00 above but 2.00 KW capacity
S & F in repairs thermostat of temperature variation ranging from 0 degree centigrade to 80 degree centigrade suitable for 25 litres and 50 litres capacity geyser complete all as specified and directed by Engr-in-Charge. Make :- Ranutrol / Indofoss or any other ISI marked as approved by GE.
S & F in repairs heating element 2KW with inbuilt thermostat including rubber ring, washer, holding clamps and nuts of following capacity complete all as specified and directed by Engr-in-Charge. Make :- BAJAJ / RECOLD / THEETA or any other ISI marked as approved by GE.
Taking down old unserviceable PVC connection and S & F PVC connection, Mesh type heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable apparatus plate assembly and supply & fix new apparatus plate with rubber gasket, nuts and bolts of suitable size for following capacity of Storage type heater (geyser) vertical type complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-53.00 above but 25 Litres capacity
All as per Item No-53.00 above but 50 Litres capacity
M & L for preparation of old outer surfaces of storage type heater (geyser) of following capacity, type and applying two coat of synthetic enamel paint (1st quality) of approved tint by spray and including writing MES No, figure (BLOCK, ROMAN or INDIAN) with black synthetic enamel paint (1st quality) 2cm high of complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-54.00 above but 25 Litres capacity
All as per Item No-54.00 above but 50 Litres capacity
S&F in repair geyser inner tank of following capacity made out of stainless steel sheet of existing gauge confirming to IS 6/8/9 hole as per existing geyser complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-55.00 above but 25 Litres capacity
All as per Item No-55.00 above but 50 Litres capacity
Disconnecting & taking down carefully storage type water heater (geyser) 25/50 Ltr capacity, taking out heating element, thermostat and cleaning inner container by removing all scales etc and refixing of heating element, thermostat and reconnecting the same complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm dia down rod of length as per site requirement , made out of high density mild steel, including drilling the hole for split pin and duly painted same as existing colour of fan complete all as specified and directed by Engr-in-Charge.
S & Fix in repair LED indicator red/green colour of any type of geyser complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair modular white cover plate with frame for fixing of modular switches of complete all as specified and directed by Engr-in-Charge. :-
All as per Item No-59.00 above but 12 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 8 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 6 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 4 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 3 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 2 module Make: Cona / SSK / Havells
All as per Item No-59.00 above but 1 module Make: Cona / SSK / Havells
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' series for geyser & AC complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable and refix after repair/replacement shadowless surgical lights/lamp and control panel including (Sterile handle, siphonium, rotating arm, balance arm) complete all as speicifed and directed by Engr-in-Charge. Make: As per existing. Note: The rate of any unserviceable parts required for repair / replacement shall be included under respective item.
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed by Engr-in-Charge. Note: - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
M/s Shiv Builder and Suppliers
ENGINEER CORPORATION OF INDIA
PD GUPTA AND COMPANY
Bhawna Emporium
AIRCOM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .