| 1 | L1₹42.3 CrAccepted-AOC F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹42.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹42.4 CrRejected-Finance | ₹42.4 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹42.7 CrRejected-Finance | ₹42.7 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹43.8 CrRejected-Finance | ₹43.8 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹45.3 CrRejected-Finance | ₹45.3 Cr | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | GEMINI PROMOTERS AND BUILDERS PVT. LTD. L2 | ASHISH JINDAL BUILDERS PVT. LTD. L4 | Ram Parkash Constructions Pvt. Ltd. L7 | Pooja Singla Builders And Engineers Pvt Ltd L8 | M/s Khanna Enterprises L6 | Hariom Projects Pvt Ltd L10 | M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd. L14 | RAGHUSONS INFRA ENGINEERING PVT. LTD L13 | Rabina Enterprises Pvt Ltd L15 | SRISHTI INFRASTRUCTURES LIMITED L17 | City Promoter and Buildwell Pvt. Ltd. L1 | Pawansut Infra Projects Pvt. Ltd. L19 | M/s DMR Builders Pvt Ltd L11 | ENGINEER CONSTRUCTION PVT. LTD. L3 | SHRI GURMUKHDAS CONTRACTORS PVT. LTD. L16 | M/s Aadhar Stumbh Infra Pvt Ltd L5 | NAND LAL PURI AND SONS PRIVATE LIMITED L9 | GIRDHARI LAL CONSTRUCTIONS PVT LTD L18 | MUKUL BUILDERS LLP L12 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Designing, fabricating, manufacturing, transporting, erecting, installing of pre-stressed/ precast solid concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories, etc. for construction of boundary wall having height of 4 metres from existing average ground level and 0.9 metres below the existing average ground level comprising as under complete all as specified and as directed: - | 6,000 | RM | 17,000 ₹10.2 Cr | 18,950 ₹11.4 Cr | 19,250 ₹11.6 Cr | 20,000 ₹12 Cr | 18,500 ₹11.1 Cr | 25,000 ₹15 Cr | 24,000 ₹14.4 Cr | 22,000 ₹13.2 Cr | 26,590 ₹16.0 Cr | 27,299 ₹16.4 Cr | 16,370 ₹9.8 Cr | 24,000 ₹14.4 Cr | 24,500 ₹14.7 Cr | 19,900 ₹11.9 Cr | 22,500 ₹13.5 Cr | 19,500 ₹11.7 Cr | 27,000 ₹16.2 Cr | 21,000 ₹12.6 Cr | 25,000 ₹15 Cr |
| 1.01(a) Supply and erecting factory made pre-tensioned pre-stressed concrete column of size 5200 mm (Height) X minimum cross section of 300 mm X 300 mm made with minimum M40(Design Mix) concrete and including minimum 12 Nos 4 mm dia steel high tensile steel strands (IS 6006)/ hard drawn and stress-relieved wire (IS 6003), minimum shear stirrups as required, having provision for fixing with precast panel, provision for fixing with swan neck for laying of concertina coil. (b) Precast solid concrete element for panel of size 3175 mm X 4900 mm X minimum 100 mm thick (02 Nos factory made precast members of size 3175 X 2450 X 100 mm each) made with minimum M30 (Design Mix) concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. | ||||||||||||||||||||||
| 1.02(c) Precast solid concrete element for foundation (minimum 150 mm thickness) in minimum M30 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. (d) Necessary excavations and earthworks including returning, filling and removal upto 50 metres. (e) Provision of 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element. (f) Provision of swan neck (Y type horn) made out of MS angle 50 mm X 50 mm X 6 mm duly galvanized coated of shape and having provision to fix galvanized barbed wire and concertina coil. (g) Provision of 6 Nos galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to swan neck including securing or tying at crossings with and provision of galvanized iron binding wire, GI staples or steel pins, etc. | ||||||||||||||||||||||
| 1.03(h) Provision of punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations. | ||||||||||||||||||||||
| 1.04The boundary walls (in ‘L’ or ‘T’ Shape) of the height 4000 mm and footing depth of 1200 mm with minimum thickness of 100 mm in wall and 150 mm in foundation and minimum M30 (Design Mix) concrete shall alternatively be considered for provision of boundary wall. 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element shall be provided. The provision of swan neck, galvanised barbed wire, concertina coil shall be as mentioned above. The necessary provision for fixing swan neck to precast panel shall be made for laying of concertina coil. | ||||||||||||||||||||||
| 1.05Notes for BOQ srl item No 1.00 above :- (i) the quoted rate shall be based on the reinforcement requirements and dimensions as determined by design calculations, subject to compliance with the minimum reinforcement and dimension as specified in the relevant Indian Standards. In cases where the design calculations indicate a requirement lower than the prescribed minimum standards, the minimum provisions of the Indian Standards shall prevail and be implemented accordingly. (ii) Weep holes of dia 50 mm shall be left at 1000 mm spacing in each panel just above ground level. The necessary extra reinforcement shall be provided around weep holes. (iii) The expansion/ separation joints shall be provided at every 30 metres along the boundary wall. The measurement of the boundary wall for payment purposes shall be made in running metres, including the length occupied by the crumple joints. No extra payment shall be made on account of double provisions of column or any additional components required at the crumple joint locations. (iv) The net bearing capacity shall be 8 t/m2 at 1.2 metre depth from ground level. (v) The Design shall be vetted by the Government Engineering Colleges. (vi) Cost for loading, unloading, transportation /T&P (Hydra crane/crane and vehicle), erecting, inserting shall deemed to be included in the unit rate quoted, nothing extra shall be paid on this account. (vii) For the purpose of Running Payment, the rate for the Provision of punched tape concertina coil and barbed wire fencing on the top of wall shall be restricted to 8% of the quoted rate for BOQ. | ||||||||||||||||||||||
| 2.00 | Designing, fabricating, manufacturing, transporting, erecting, installing of pre-stressed/ precast solid concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories, etc. for construction of boundary wall having height of 3 metres from existing average ground level and 0.9 metres below the existing average ground level comprising as under complete all as specified and as directed: - | 16,440 | RM | 14,500 ₹23.8 Cr | 15,500 ₹25.5 Cr | 16,250 ₹26.7 Cr | 17,000 ₹27.9 Cr | 17,300 ₹28.4 Cr | 14,500 ₹23.8 Cr | 19,300 ₹31.7 Cr | 20,000 ₹32.9 Cr | 18,460 ₹30.3 Cr | 19,999 ₹32.9 Cr | 13,935 ₹22.9 Cr | 20,200 ₹33.2 Cr | 19,000 ₹31.2 Cr | 14,750 ₹24.2 Cr | 20,500 ₹33.7 Cr | 14,990 ₹24.6 Cr | 18,000 ₹29.6 Cr | 19,200 ₹31.6 Cr | 19,000 ₹31.2 Cr |
| 2.01(a) Supply and erecting factory made pre-tensioned pre-stressed concrete column of size 4200 mm (Height) X minimum cross section of 300 mm X 300 mm made with minimum M40(Design Mix) concrete and including minimum 12 Nos 4 mm dia steel high tensile steel strands (IS 6006)/ hard drawn and stress-relieved wire (IS 6003), minimum shear stirrups as required, having provision for fixing with precast panel, provision for fixing with swan neck for laying of concertina coil. (b) Precast solid concrete element for panel of size 3175 mm X 3900 mm X minimum 100 mm thick (02 Nos factory made precast members of size 3175 X 1950 X 100 mm each) made with minimum M30 (Design Mix) concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. | ||||||||||||||||||||||
| 2.02(c) Precast solid concrete element for foundation (minimum 150 mm thickness) in minimum M30 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. (d) Necessary excavations and earthworks including returning, filling and removal upto 50 metres. (e) Provision of 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element. (f) Provision of swan neck (Y type horn) made out of MS angle 50 mm X 50 mm X 6 mm duly galvanized coated of shape and having provision to fix galvanized barbed wire and concertina coil. (g) Provision of 6 Nos galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to swan neck including securing or tying at crossings with and provision of galvanized iron binding wire, GI staples or steel pins, etc. | ||||||||||||||||||||||
| 2.03(h) Provision of punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations. | ||||||||||||||||||||||
Tender Value
₹50.0 Cr
EMD Value
₹15 L
Closing Date
23 Apr 2026, 6:00 pmClosed
Chief Engineer Bathinda zone
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
PROVISION OF SECURITY WALL WITH ALLIED SUPPORT INFRASTRUCTURE (PHASE-II OF TWO PHASES) AT BATHINDA MILITARY STATION
2026_MES_759094_1
84575
Open Tender
Civil Works
548 days
GE (P) Bathinda
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) Bathinda
₹15 L
Yes
7 May 2026
3 Apr 2026
25 Apr 2026
3 Apr 2026
23 Apr 2026
17 Apr 2026
4 Apr 2026 - 23 Apr 2026
Designing, fabricating, manufacturing, transporting, erecting, installing of pre-stressed/ precast solid concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories, etc. for construction of boundary wall having height of 4 metres from existing average ground level and 0.9 metres below the existing average ground level comprising as under complete all as specified and as directed: -
(a) Supply and erecting factory made pre-tensioned pre-stressed concrete column of size 5200 mm (Height) X minimum cross section of 300 mm X 300 mm made with minimum M40(Design Mix) concrete and including minimum 12 Nos 4 mm dia steel high tensile steel strands (IS 6006)/ hard drawn and stress-relieved wire (IS 6003), minimum shear stirrups as required, having provision for fixing with precast panel, provision for fixing with swan neck for laying of concertina coil. (b) Precast solid concrete element for panel of size 3175 mm X 4900 mm X minimum 100 mm thick (02 Nos factory made precast members of size 3175 X 2450 X 100 mm each) made with minimum M30 (Design Mix) concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column.
(c) Precast solid concrete element for foundation (minimum 150 mm thickness) in minimum M30 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. (d) Necessary excavations and earthworks including returning, filling and removal upto 50 metres. (e) Provision of 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element. (f) Provision of swan neck (Y type horn) made out of MS angle 50 mm X 50 mm X 6 mm duly galvanized coated of shape and having provision to fix galvanized barbed wire and concertina coil. (g) Provision of 6 Nos galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to swan neck including securing or tying at crossings with and provision of galvanized iron binding wire, GI staples or steel pins, etc.
(h) Provision of punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations.
The boundary walls (in ‘L’ or ‘T’ Shape) of the height 4000 mm and footing depth of 1200 mm with minimum thickness of 100 mm in wall and 150 mm in foundation and minimum M30 (Design Mix) concrete shall alternatively be considered for provision of boundary wall. 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element shall be provided. The provision of swan neck, galvanised barbed wire, concertina coil shall be as mentioned above. The necessary provision for fixing swan neck to precast panel shall be made for laying of concertina coil.
Designing, fabricating, manufacturing, transporting, erecting, installing of pre-stressed/ precast solid concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories, etc. for construction of boundary wall having height of 3 metres from existing average ground level and 0.9 metres below the existing average ground level comprising as under complete all as specified and as directed: -
(a) Supply and erecting factory made pre-tensioned pre-stressed concrete column of size 4200 mm (Height) X minimum cross section of 300 mm X 300 mm made with minimum M40(Design Mix) concrete and including minimum 12 Nos 4 mm dia steel high tensile steel strands (IS 6006)/ hard drawn and stress-relieved wire (IS 6003), minimum shear stirrups as required, having provision for fixing with precast panel, provision for fixing with swan neck for laying of concertina coil. (b) Precast solid concrete element for panel of size 3175 mm X 3900 mm X minimum 100 mm thick (02 Nos factory made precast members of size 3175 X 1950 X 100 mm each) made with minimum M30 (Design Mix) concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column.
(c) Precast solid concrete element for foundation (minimum 150 mm thickness) in minimum M30 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall and including reinforcement (TMT bar) as per IS 456: 2000, having provision for fixing with pre-tensioned pre-stressed concrete column. (d) Necessary excavations and earthworks including returning, filling and removal upto 50 metres. (e) Provision of 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element. (f) Provision of swan neck (Y type horn) made out of MS angle 50 mm X 50 mm X 6 mm duly galvanized coated of shape and having provision to fix galvanized barbed wire and concertina coil. (g) Provision of 6 Nos galvanized steel barbed wire with two strands of line wire of dia 2.24 mm and barbed with point wire of dia 2 mm at 75 mm spacing straining and fixing to swan neck including securing or tying at crossings with and provision of galvanized iron binding wire, GI staples or steel pins, etc.
(h) Provision of punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations.
The boundary walls (in ‘L’ or ‘T’ Shape) of the height 3000 mm and footing depth of 1200 mm with minimum thickness of 100 mm in wall and 150 mm in foundation and minimum M30 (Design Mix) concrete shall alternatively be considered for provision of boundary wall. 100 mm thick lean concrete in M7.5 (Nominal Mix) below precast foundation element shall be provided. The provision of swan neck, galvanised barbed wire, concertina coil shall be as mentioned above. The necessary provision for fixing swan neck to precast panel shall be made for laying of concertina coil.
Material and labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of approved tint/shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by using paint brush/Roller complete all as specified and directed
Supply & fixing 110mm dia PVC (SWR) pipe single socketed in any length laid in trenches or under floor complete all as specified and as directed.
Surface excavation not exceeding (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint, Consist with Inbuilt junction box with aluminium bus bar suitable for 3 phase & Neutral, 4 wire of capacity 32 Amps and MCB 6 Amps SPN complete with fixing clamps complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge
Supply and fixing LED street light fitting 70Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed.
S & F Three core cord flexible wire, copper conductor multistranded, PVC insulated industrial cable and overall PVC sheathed of size 2.5 Sqmm 1100 Volt complete all as specified and as directed.
M & L for cable route indicator made out of CI plate 100 dia, 8 mm thick, embossed with lettering "MES LT Cable", welded or bolted onto 35 mm X 35 mm X 6 mm angle iron, 500 mm long duly painted with anti-corrosive paint in brown colour & including necessary earthwork and excavation, embedded in PCC M15(Nominal Mix) using 20 nominal size graded crushed stone aggregate of size 400 mm X 400 mm X 300 mm complete all as specified and as directed.
Supply & installation of silent Diesel Engine driven generating set 415 Volts, 3 phase 4 wire, engine as per IS: 10001/ 10002 and alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc of capacity 20 KVA. Having salient Features Below For (a) DG Set :- (i) Current Rarting - 20.86 Amp (ii) Power factor -0.8 (iii) Prime power rating - 20 Kva (b) Engine:- (i) BHP- 24.5 HP (ii) Cooling -water cooled (iii) Aspiration -Natural (iv) Cylinders -02 Nos (Inline) (v) RPM-1500 (vi) lub oil -IS 13656 (c) Alternator :- Brushless type ,Synchronous ,A.C Generators continuously rated 415 Volts ,3 phase,4 wire, 50 Hz ,0.8 power at 1500RPM, 4 pole screen protected ,drip proof ,Horizontal foot-mounted , Self Excited ,self regulated ,with static excitation system ,Class 'H' insulation. The alternator is capable of developing rated output . (d) Control Panel :- (i) APF panel (ii) Protection include -Low lube oil pressure trip, High Engine temperature trip ,Overload protection , Short Circuit protection , Over/under Voltage protection Complete installation as recommendation by OEM (Foundation Etc)
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 150 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 240 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 300 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
M&L for Earthing complete with galvanized iron slotted pipe of dia 40mm bore, 3 mtr long (earth pit not less than 10 mtr deep below normal ground level) surrounded by adequate quantity of charcoal, dust and salt to packed thickness of 15 cm on all sides, connected to GI wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth and rivetted/welded to earth plate at one end and other end of strip connected to equipemnent body/ test point with two nos nuts , bolts including 4 mm GI wire clamp. nuts bolts and washers and also watering pipe 20mm bore GI pipe medium garde from earth p[it to top electrode including funnel, wire mesh,copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40 mm thick PCC 1:2:4 type B1 cover complete all as shown in electrical plate No 3 of SSR Part-I including necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50 mtr complete all as specified and as directed. Note :- PCC Chamber shall be constructed atleast 1.5 Mtr away from the earthing electrode and pipe for watering shall be provided in stanting manner.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed.
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- Incomming :- (a) S&F MCCB 4 Pole 32 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 01 No incoming. (b) Copper Busbar 50 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set OUTGOING :- (d) MCB TPN 16 Amp, 415 V, 10 KA, C-series - 03 Nos (for Street Light and 01 spare ) (e) Astronomical Digital Programmable Timer Switch using power contactor 16A 3 Pole 415 V DIN type time swtich 230V- 02 Nos (f) Multi function VAF meter - 01 No. (g) LED Indicating Lamps R,Y,B - 01 Set of three
M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters "HT Cable" embedded in position in PCC (1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc and getting out complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceeding 1.5mtr but not exceeding 3.00 metre in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc and getting out complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed.
material and labour PCC 1:3:6 type C2 using 40mm graded crushed stone agreegate as in foundation of poles/struts etc including necessary form work complete and all as directed by Engr-in-charge.
material and labour PCC 1:2:4 type B1 using 20mm graded crushed stone agreegate as in coping of poles/struts etc including necessary form work complete and all as directed by Engr-in-charge.
Dismantling old/UNSV concrete pole/struts any size for shifting within 200 mtr and preparation for re-erection by demolishing old concrete and cleaning complete all as specified and directed by Engr - in -Charge.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 110 mm, minimum inside dia 82 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
Supply and fixing Astronomical Street light timer of rating 6 kw , conforms to IS /IEC 60947-4-1, provided with protection Degree IP 54, extended wide band coil, FRLS (Fire retardant low smoke) internal wiring. In-built Short-Circuit Protection, Class H Insulation including 32Amps TP mcb 'C' Curve, 10 KA, 415V one No. and MCB TPN 40A, 'C' curve, 10 KA, 415V one No., complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.10 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
PDFsam_merge.pdf
Tender Documents • 2.66 MB
BOQ_850255.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid