Loading…
Loading…
Tender Value
₹16.2 Cr
EMD Value
₹26.2 L
Closing Date
16 May 2026, 3:00 pmClosed
EXECUTIVE ENGINEER BUILDING DIVISION KHAGARIA
EXECUTIVE ENGINEER
Chitragupta Nagar, Near Town Hall, Khagaria
SUPERINTENDING ENGINEER BUILDING CIRCLE BHAGALPUR
SUPERINTENDING ENGINEER BUILDING CIRCLE BHAGALPUR
CONSTRUCTION OF TYPE A,B &C QUARTER RESIDENCE AT SUBDIVISONAL CIVIL COURT GOGRI DISTT KHAGARIA
129567
NIT-16/BCD/KHAGARIA/2025-26
Open Tender
GENERAL
Khagaria
• Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given.
Total Bid Security Amount in Rupees Rs. 2621000.00
• (i) Legal Status of Bidder
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid
• Total value of civil engineering construction work, in Rupees, Performed in last five years. minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work of at least the equal to the 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year
2020-21
2021-22
2022-23
2023-24
2024-25
• Amount in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost
• Minimum Quantities of work done as prime contractor in any one year during last five years, units shall be same as in Requirement column
Items Unit 50% Quantity/Amount
Earthwork - 2289 m3
PCC - 110 m3
RCC - 1604 m3
Brick Work - 881 m3
Tiles - 2428.8 m2
Fire - 1.675 Lacs
PHE - 36.3 Lacs
Electrical - 1.01 crore
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year
• (a) Amount of Existing commitments and ongoing works in Rupees
(b) Amount of Work for which Bid already submitted, in Rupees
• Numbers and Maximum age of Equipments with bidder Type of Equipment Nos. Maxm. Age
Concrete Mixer with Integral weigh Batching facility 2 5
Water Tanker 1 5
Steel shuttering 3000 sft 5
Vibrator (Plate & Niddle) 4 5
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification
Site Engineer / B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 1 No.
Site Supervisor /Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 2 No.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid).
Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment
Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not)
Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct.
• Undertaking Select from drop down list. Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract.
• Time of Completion in months AS PER NIT
• Registration No.
IT.& GST
Labour License
Character Certificate
NOC for Debar (If required)
GENERAL
PERCENTAGE
L1
1
11 documents required · 11 mandatory
₹10,000
Processing Fee: 5900
₹26.2 L
Pre-Bid meeting on 07-05-2026 03:00 pm at OFFICE OF C.E, SOUTH, BCD PATNA
21 Apr 2026
21 Apr 2026
18 May 2026
21 Apr 2026
16 May 2026
21 Apr 2026
29 Apr 2026
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed
Filling available excavated earth do - do all complet job
Extra for every additional lift of 1.5 m or part thereof in
Supplaying and filling Local Sand do - do all complet job
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing designation 100 A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:3:6(1 Cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength andadmixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.
Extra for R.C.C work above floor V level for each four floors or part thereof.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete:All work upto plinth level
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete All work from plinth level upto floor V level.Walls, columns, pillars, posts and struts
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete All work from plinth level upto floor V level.Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C. Walls columns, pillars, posts cind strutsAll work above Plinth level upto floor V Level.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C Extra for R.C.C work above floor V level for each floor or part there of.
Beams, plinth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.All works upto floor V level
Beams, plinth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.Extra for R.C.C work above floor V level for each four floors or part there of
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Reinforcement for R.C.C. work including straightening, cutting, bending,
centring and shuttering
Providing 100A B/W with fly ash in CM (1:6) do - do all complet job
Brick work with bricks with fly ash bricks as per IS 12894(2002) & 3495 in foundation and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for Brick work in superstructure above plinth level upto floor V level
Extra for providing and placing in position 2 Nos, 6 mm dia , MS bars at every third course of half brick masonry (with F. P. S. bricks)
Brickwork with bricks of class designation 100A in foundation and plinth:cement mortar 1:6(1cement :6 coarse sand)
Providing 100 A Brick work with fly ash bricks in CM(1:4) do - do all complet job
Extra for providing and placing in position 2 Nos, 6 mm dia , MS bars at every third course of half brick masonry (with F. P. S. bricks)
Providing 100A B/W with fly ash in CM (1:6) do - do all complet job
Extra for brick work in su[er structure above floor V levels for each four floor or part therefore
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :ement mortar 1:6 (1 cement: 6 coarse sand ):Extra tor Brick work in superstructure above plinth level upto floor V cum Extra for brick work in superstructure above floor V level for each four floors or part thereof.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :ement mortar 1:4 (1 cement: 4 coarse sand ):Extra tor Brick work in superstructure above plinth level upto floor V cum Extra for brick work in superstructure above floor V level for each four floors or part thereof.
12 mm cement plaster of mix:
15 mm cement plaster on rough side of single or half brick wall of mix.
Extra for plastering exterior walls of height more than 10m from ground Level for every additional height of 3m or part there of
6 mm cement plaster to ceiling of mix
12mm cement plaster to ceiling of mix :1:3(1 cement: 3 coarse sand)with floating coat of cement punning
15mm cement plaster to ceiling of mix :1:3(1 cement: 3 coarse sand)with floating coat of cement punning
Finishing walls with Acrylic Smooth exterior paint of required shade
Applying one coat of cement primer of approved brand and manufacture on wall surface:Distemper primer :Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete:Two or more coats on new work
Distempering with oil bound washa ble distemper of approved brand and manufacture to give an even shade .New work (two or more coats ) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade
Applying one coat of cement primer of approved brand and manufacture on wall surface:Distemper primer
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade New work (three or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.Two or more coats on new work
Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel prime
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer
Providing and fixing steel glazed doors, windows and ventilatrs of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with woodenplugs and screws or raw) plugs and screws or with fixing dips or with bolts and nuts as required, including providing and fixing of glass panes with glazing dips and special metal-sash putty pf approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc.
Extra for providing and fixing steel beading of approved shape and section with screws instread of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.Steel windows
Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer
Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including stainless steel butt hinges with necessary screwssqm
Providing and fixing pressed steel door confirming IS code 4351 manufactured from commerical mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechnical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
Providing and fixing bright finished brass peg stays 300 mm long of minimum weight 330 gms.to side hung steel windows with necessary welding and machine screws etc. complete
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ),transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete:
Providing and fixing aluminium hanging floor door stopper, ISInmarked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete
Providing and fixing 100mm brass mortice locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer in-chargePowder coated minimum thickness 50 micron aluminium
Providing and fixing bright finished brass 100 mm mortice latch andlock, ISI marked, with six levers and a pair of anodised (anodiccoating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete
Applying priming coat
With ready mixed zinc chromate yellow primer of approvedbrand and manufacture on steel galvanized iron/steel works
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixedwith pigment to match the shade of the slab including rubbing and polishing completeBasewith1:1:1(1lime1surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse san
Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Details of cost for 10 s
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
52 mm thick cement concrete flooring with metallic concrete hardener topping under layer 40 mm thick cement concrete 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick metallic concrete hardener consisting of mix 1:2 (1 cement hardener mix:2 stone aggregate 6 mm nominal size) by volume @ 2 liter per 50 kg of cement or as per manufacture specification. This includes cost of cement slurry, etc. but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting (upto 30 cm hieght) with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement.18 mm thick
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
Providing edge moulding to 18 mm thick marble stone counters,vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete.
Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound conforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and specifed by the Engineer-in-Charge.
Providing and fixing 10 mm thick acid and / or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding,
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class wood battens 25 mm minimum depth on all edges of shutters (Over all area of door shutter to be measured).
Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws,the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer’s specification and direction of Engineer -in- charge.
35 mm thick factory made Solid panel PVC Door shutter, made out ofsingle piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm,out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mmto be flat and 20 mm to be tapered at both end s, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel,all complete as per manufacturer’s specification and direction of Engineer-in-chargeNon decorative finish (matt finish)
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick,95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30 mm thick plain PVC door shutters
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New steel work (two or more coats)
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and softwood)
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing 250mm wide fly ash brick drain in cement mortar (1:6) with av. 150mm.Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions.(ii) 11 nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) Illrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) Ivth course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni).
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc.,with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on backside of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge,all complete.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONL do - do all complet job
Along external Wall where the apron
Along external Wall below concrete
Treatment of Soil under existing floor do - do all complet job.
Construction of granular sub base by providing close graded Material conforming to specification mixing in a mechanical mix plant at OMC carriage of mixed material by tipper to work site for all leads & lifts
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as permanufacturer’s specifications & direction of Engineer -in-Charge:
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including ntegrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern,with fittings, standard size C.P. brass lush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P Brass brackets and guard rails complete fixed with 40mm long screws, rawl plugs etc.complete.
Providing and fixing toilet paper holder:
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangem ent of approved quality and colour.
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing C.P. brass shower rose with 15 o r 20 m m in let :
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete75 mm
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete110 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Making connection of G.I distribution branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
Providing and fixing brass stop cock of approved quality :
Providing & fixing gun metal gate valve with C.I. wheel of approved quality, (screwed end) :
20 mm nominal bore
Providing and fixing gun metal non-return valve of approved quality (screwed end).
Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS :8931
Providing and fixing PTMT grating of approved quality and colour.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy aluminium rod with L.P / H.P.H.D plastic ball.
roviding and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
Excavating trenches of required width for pipe cables etc
Constructing brick masonry chamber forunderground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.EHD - 35 Circular shape 560 mm internal dia
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20 mm diameter round bar
Making soak pit 2.5m diameter 3.0 metre deep with 45x45cm dry brick honey comb shaft with bricks of class designation 75 and S.W drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. Dia 150mm
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipeswith ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.Dia 75mm
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150 mm dia
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Extra for depth for manholes
Time of completion :-
Date of Opening Tender:-
Code No.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing batten/angle holder including connection etc as required.
S/F electronic musical call bell suitable for single phase 230 volts complete bell as required.
S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.(15sq.ft extra for metering. unit for every qtr.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number additional pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioingi, protective covering and refilling the trench etc. as reqd.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements.(Make- Otis, Kone, Schindler, Mitshubishi, Thyssen Krupp)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
300 mm sweep
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
P/F/F sheet metal main switch disconnector fuse unit in existing metal board with rewirable type fuses, including drilling holes in metal board, making connection as reqd.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing batten/angle holder including connection etc as required.
S/F electronic musical call bell suitable for single phase 230 volts complete bell as required.
S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
63 Amp, double pole (for every Qtr)
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as require
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc. (15sq.ft extra for metering. unit for every qtr.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number additional pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioingi, protective covering and refilling the trench etc. as reqd.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements.(Make- Otis, Kone, Schindler, Mitshubishi, Johnson/Thyssen Krupp)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
P/F/F sheet metal main switch disconnector fuse unit in existing metal board with rewirable type fuses, including drilling holes in metal board, making connection as reqd.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conducter SC cable in surface / recessed medium class PVC conduit as required.
2X 10 sq mm + 1 X 6 sq mm (for Power DB)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed PVC conduit as required
1x1.5 sq.mm (for inverter)
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. As required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.
Supplying and fixing 2 pin, 5/6 amps ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing batten/angle holder including connection etc as required.
S/F electronic musical call bell suitable for single phase 230 volts complete bell as required.
S/F following way single pole & neutral, sheet-steel, MCB DB - 240 V on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar,interconnections, powder painted including earthing etc as required.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F following rating, 240/415 volts, 'C' curve circuit breaket suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as reqd.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Earthing with copper earth plate 600 mm x 600mm x3mm G.I thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal /coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying & fixing of following types lamp in the existing electrical fitting/fixtures etc. As reqd.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
P/F following capacity rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc. (9sq.ft extra for metering. unit for every qtr.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supplying of copper strip of all sizes for bus bar strip/interconnection including drilling holes etc as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supply of following sizes and core PVC/XLPE insulated, PVCsheathed (heavy duty) armoured electrical power cablewith aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number additional pvc insulated and pvc sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioingi, protective covering and refilling the trench etc. as reqd.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements.(Make- Otis, Kone, Schindler, Mitshubishi, Johnson/Thyssen Krupp)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As reqd.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
P/F/F sheet metal main switch disconnector fuse unit in existing metal board with rewirable type fuses, including drilling holes in metal board, making connection as reqd.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
P/F/F bus bar chamber with 4 strips of suitable size made of copper heavy duty complete with all accessoires including connection earthing the body etc.as reqd.
Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required.
Supplying and connection of following sizes ISI marked FR PVC insulated, single core copper conductor cable etc as reqd.
2 x 1.5 sq. mm
Fabrication, supply, Installation testing and commissioning of Street Light Feeder Pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, digital ammeter & voltmeter, RYB LED lamp, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals etc. complete in all respect, suitable for following incoming and Outgoings as required. (CPRI Approved Panel Mfg.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
CHECK LIST AND OTHER DOCUMENTS.pdf
NIT • 14.19 MB
NIT 01.pdf
NIT • 0.66 MB
SBD_NIT 1.doc
NIT • 0.85 MB
BOQ.xlsx
NIT • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .