Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹8.4 L+₹1.4 L (20.0%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹8.6 L+₹1.6 L (22.9%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹8.8 L+₹1.8 L (25.8%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.0 L+₹2.0 L (27.9%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹17,200
Closing Date
21 Sept 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repair Maintenance to Internal Wiring replacement of MCBs DBs in OTM Accn including Repair Maint of cooling appliances at AF Stn Singarsi under AGE I AF Singarsi
2020_MES_375123_1
C/8490/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹17,200
Yes
5 Nov 2020
5 Sept 2020
22 Sept 2020
5 Sept 2020
21 Sept 2020
9 Sept 2020
60 days
Amount
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc removing materials to store for reuse or for taking credit removing from site and making good disturbed surface of walls, floors etc.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site.
M & L for point wiring with FR PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping terminated in PVC block 50 mm deep (sunken) for fixing of switches, sockets, fan regulators etc (PVC box of required size will be measured and paid under relavent item) for One light point or one fan point or bell point controlled by one switch or bell push all as directed.
All as per Item 3 above but One 3/5 pin socket outlet, 5 Amp independent
All as per Item 3 above but One 3/5 pin socket outlet, 5 Amp on the same board with other switches
M & L for point wiring with FR grade PVC insulated unsheathed multistranded copper conductor cables of 2.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm size through and including PVC casing & caping terminated in and including PVC block 50 mm deep (sunken) for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent .
M & L for concealed point wiring with FR grade PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches, sockets, fan regulators etc for One light point or one fan point controlled by one switch [Note: - Modular switch boards and Cutting chases & making good of disturbed surfaces shall be measured and paid separately.
All as per Item 7 above but One 3/5 pin socket outlet, 5 Amp independent
All as per Item 7 above but One 3/5 pin socket outlet, 5 Amp on the same board with other switches
M & L for concealed point wiring with FR grade PVC insulated unsheathed multistranded copper conductor cables of 2.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent [Note: - Modular switch boards and Cutting chases & making good of disturbed surfaces shall be measured and paid separately.
S & F Modular Switch 1 way 6 A, 1 module
S & F Modular Switch 1 way 16 A, 1 module
S & F Modular Socket 6 A, 2/3 pin combined 2 module
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
S & F Modular Fan step regulator, 120 watt, 2 module
S & F Modular Bell push 6A, 1 module
S & F Modular Blank plate, 1 module
S & F Modular type White cover plate with frame 3 module
S & F Modular type White cover plate with frame 4 module
S & F Modular type White cover plate with frame 6 module
S & F Modular type White cover plate with frame 2 module
S & F Modular type White cover plate with frame 1 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 1/2 module
S & F Switch piano, flush type single pole, one way 5 Amp
Fixing only Switch piano, flush type single pole, one way 5 Amp (as retrived against item Ser No 2 here-in-before)
S & F Socket outlet 2 in 1, 3 pin, 5 Amp
Fixing only Socket outlet 2 in 1, 3 pin, 5 Amp (as retrived against item Ser No 2 here-in-before)
S & F Switch socket combination 2 in 1, 5 Amp flush type
Fixing only Switch socket combination 2 in 1, 5 Amp flush type (as retrived against item Ser No 2 here-in-before)
S & F Bell push, flush type, 5 amp
Fixing only Bell push (as retrived against item Ser No 2 here-in-before)
S & F Switch socket combination 5A/ 16A, 5 in 1flush type
Fixing only Switch socket combination 5A/ 16A, 5 in 1flush type (as retrived against item Ser No 2 here-in-before)
S & F Switch piano, flush type single pole, one way 15 Amp
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type
S & F Bell , AC, 230 Volts, single pole
S & F Musical Call Bell
S & F stepped type electronic fan regulator flush type
Fixing only fan regulator any type (as retrived against item Ser No 02 here-in-before)
S & F Ceiling rose, 3 terminal PVC insulated body
Fixing only Ceiling rose any type (as retrived against item Ser No 2 here-in-before)
M&L for dismantling the window type AC of capacity in 1.5 Ton in various location, shifting it to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning the ‘No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by thermocol, ply wood, wooden bit Including replacing of starting capacitor, running capacitor, relay , thermostate, and capillary tube all as directed & specified by Engineer-in-Charge (NOTE: The spare parts measured & paid separately ie compressor, condensing coil, blower motor)
Supply & Fix new compressor sealed unit of suitable capacity / model in the unit properly for 1.5 TR window type AC all as specified and directed by Engr-in-Charge. (As per existing make)
S&F for cooling coil unit for window type AC of any type all as specified and directed by Engr-in-Charge.(As per existing make)
S&F for overload protection coil (1622) 230 Volts for window type AC 1.5 Ton capacity.
M&L for runner made of aluminium suitable and operation knob for window type AC 1.5 ton capacity including taking out old unserviceable runner.
Taking out complete unserviceable wiring for AC window type 1.5 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete.
S&F for replacement of PVC air filter for window type AC of 1.5 ton capacity including taking out old unserviceable air filter.(As per existing make)
Supply only blower motor including fan blade, capacitor complete suitable for window type AC 1.5 ton capacity 1/8 HP, 220 Volts, single phase all as specified and directed by Engr-in-Charge.(As per existing make)
S&F for capacitor for blower motor suitable for window type AC 1.5 ton capacity including taking out old unserviceable capacitor.(As per existing make)
S&F for fan blade for blower motor suitable for window type AC 1.5 ton capacity including taking out old unserviceable fan blade.(As per existing make)
S&F for fan blade for window type AC of any capacity including taking down old unserviceable fan blade all as specified and directed by Engr-in-charge.(As per existing make)
S&F for front grill for window type AC 1.5 ton capacity as directed by Engr-in-charge including taking out old unserviceable front grill.
S&F for swinging motor with louvers as per existing make for window type AC 1.5 ton capacity including taking out old unserviceable swinging motor.(As per existing make)
S&F for PCB for control unit for window type Ac 1.5 ton capacity as per existing and same make.
M&L for dismantling the split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton in various location, shifting to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning “the No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location/new location as directed, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts Including replacing of starting capacitor, running capacitor, over load protection relay are included in the relevent item (compressor, condensing coil measured & paid separately).
Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR split type AC all as specified and directed by Engr-in-charge.(As per existing make)
Supply & Fix new compressor seal unit of suitable capacity/model in the unit properly for 2 TR split type AC all as specified and directed by Engr-in-charge.(As per existing make)
Labour only for charging refrigerant gas in the system of split AC of 1.5 ton capacity all as directed by Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant item No 83,84 & 85 as applicable as supply only.)
Labour only for charging refrigerant gas in the system of split AC of 2.0 ton capacity all as directed by Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant item No 83,84 & 85 as applicable as supply only).
M&L for replacement of capillary tube and stainer for split AC of 1.5 ton/2.0 ton capacity.
Supply only condensing coil unit for split type AC 1.5 / 2.0 ton capacities all as specified and directed by Engr-in-charge.
S&F for cooling coil unit for split type AC of any type all as directed by Engr-in-charge including taking out old unserviceable cooling coil unit.(As per existing make)
S&F for copper pipe 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) for connection indoor and out door unit.
S&F for PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS.
S&F for PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS.
S&F for swinging motor with louvers as pr existing out old unserviceable swinging motor with louvers.(As per existing make)
S&F for blower motor including fan blade, capacitor complete (indoor unit/out door unit) for split type AC 1.5 ton / 2.0 ton capacity 220 volts, single phase including taking out old unserviceable blower motor.
S&F for fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity including taking out old unserviceable blade.
S&F for fan blade for outdoor unit of split type AC of any capacity including taking down old one all as directed by Engr-in-charge.
S&F for LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity including taking out old unserviceable unit.(As per existing make)
S&F for replacement of PVC air filter for AC split type 1.5 / 2.0 ton capacity.(As per existing make)
S&F for PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same make.
M&L for dismantling of storage type refrigerator of 165/310 ltrs capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and sticking a sticker mentioning the “No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location including masonry work all as directed & specified by Engineer-in-Charge.including replacement of relay, thermostate material keeping tray , chiller tray freezer door (indoor) metalic door rubber (NOTE: The spare parts ie compressor, cooling unit measured and paid separately).
Supply & Fix new compressor seal unit of 165 ltrs capacity of existing model in the unit properly for domestic refrigerator of any type all as specified and directed by Engr-in-charge.(As per existing make)
Supply & Fix new compressor seal unit of 310 ltrs capacity of existing model in the unit properly for domestic refrigerator of any type all as specified and directed by Engr-in-charge.(As per existing make)
M&L for replacement of capillary tube and stainer for any type and capacity of domestic refrigerator.(As per existing make)
Supply only cooling coil unit for domestic refrigerator of any type all as specified and directed by Engr-in-charge.(As per existing make)
S&F for timer/bimetallic relay of existing type for domestic refrigerator all as specified and directed by Engr-in-charge.
Supply & Fix refrigerant gas M-22/R-22.
Supply & Fix refrigerant gas 134A.
Supply & Fix refrigerant gas HYDRO CARBON.
S&F for angular valve of size 1/2" suitable for split type AC as in repair.(As per existing make)
S&F for angular valve of size ¼" suitable for split type AC as in repair.(As per existing make)
S&F for angular valve of size 5/8" suitable for split type AC as in repair.(As per existing make)
M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/3.15 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition all as specified and directed by Engr-in-Charge including replacement of timer relay, relay up to 5 KVA capacity
M & L for rewinding of burnt out voltage stablizers (of 3 KVA/3.15 KVA capacity), winding with suitable size of superenamelleed copper wire, varnishing, heating as per manufacturers design and all as directed by Engr-in-Charge.
M & L for rewinding of burnt out voltage stablizers (5 KVA capacity), winding with suitable size of superenamelleed aluminium wire, varnishing, heating as per manufacturers design and all as directed by Engr-in-Charge.
Supply & Fix voltmetre, suitable for voltage stablizer for 3KVA to 5 KVA capacityall as specified and directed.(As per existing make)
Supply & Fix electronic circuit board, suitable for voltage stablizer for 3KVA to 5 KVA capacityall as specified and directed.(As per existing make)
Demolition of brick work built in cement mortar all as directed by Engr-in-Charge.
Cutting holes into concrete block masonry, brick work or stone masonry built in cement mortar for insert of angle iron for fixing of AC with cement concrete (1:2:4), type B1, (using 20mm graded stone aggregate) and making good the disturb surface with cement mortar (1:4) as directed.
M&L for two coats of synthetic enamel paints to new steel surfaces over a coat of red oxide zink chrome primer including preparation of new steel surfaces exceeding 10 cm width or girth complete all as directed.
S & F for Base plate of window type AC 1.5 Ton
M&L for rendering 15mm thick cement plaster in cement mortar (1:6) on fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement all as directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in cement mortar (1:6) all as specified and directed by Engr-in-Charge
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) complete all as specified and directed.
Rounaq Enterprise
M/S KUMAR AVINASH
M/S Subhadip Enterprise
M/S SINGH ENTERPRISE
M/S New Builders Corporation
Kalpana Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .