Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | M/s Vee Kay Constructions ₹11.3 Cr | ₹11.3 Cr | - |
| 2 | Qualified | - | Qualified |
| 3 | Qualified | - | Qualified |
| 4 | Qualified | - | Qualified |
| 5 | Qualified | - | Qualified |
Tender Value
Refer Docs
EMD Value
₹21.8 L
Closing Date
11 May 2022, 11:00 amClosed
KIRAN
Power Grid Corporation of India Limited Northern Region-III Headquarter 12, Rana Pratap Marg Lucknow (UP) - 226001.
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
5002002243/OTHERS/DOM/K00 - NR3 RHQ -1
Open
Civil - All
Works
GORAKHPUR
₹25,000
₹21.8 L
23 Aug 2022
26 Mar 2022
12 May 2022
26 Mar 2022
10 May 2022
26 Mar 2022
PROPOSED INDUSTRIAL TRAINING INSTITUTE FOR POWERGRID AT GORAKHPUR, UTTAR PRADESH
BILL OF QUANTITIES for BUILDING. SITE DEVLOPMENT, WATER SUPPLY & DRAINAGE, PLUMBING & SAINTARY WORK
( BASED ON DSR 2021)
RFX Ref.ofDSR2021Item/MR Item of Work Unit Quantity Amount (Rs.)
4.AA 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil cum 3489.639 716,946.33
4.AB 2.10.1.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 mAll kinds of soilPipes, cables etc, not exceeding 80 mm dia. RM 1.000 255.55
4.AC 2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, exceeding 80 mm dia but not exceeding 300 mm dia. RM 560.000 233,716.00
4.AD 2.10.1.3 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm RM 100.000 65,155.00
4.AE 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).Pipes, exceeding 80 mm dia but not exceeding 300 mm dia. RM 20.000 2,540.00
4.AF 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. cum 817.574 207,622.92
4.AG 2.26.1 Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. All kinds of soil Cum 2500.000 261,250.00
4.AH 2.27 Supplying and filling in plinth with Local sand under floors, including watering, ramming, consolidating and dressing complete. cum 157.000 339,308.40
4.AJ 2.34.1 Supplying chemical emulsion in sealed containers including delivery as specifiedChlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 900.000 180,810.00
4.AK 2.35.3.1 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration sqm 1570.000 402,155.50
4.AL 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cum 296.750 1,877,255.34
4.AM 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) Cum 20.000 121,013.00
4.AN 4.11 Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). sqm 40.000 18,090.00
4.AP 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. sqm 144.000 98,157.60
4.AQ 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete sqm 640.888 197,361.46
4.AR 5.9.2 Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. sqm 1239.913 830,183.75
4.AS 5.9.3 Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform sqm 3680.900 2,821,593.90
4.AT 5.9.4 Centering and shuttering including strutting, propping etc. and removal of form for :Shelves (Cast in situ) sqm 5.000 3,832.75
4.AU 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 4220.874 2,567,768.70
4.AV 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts sqm 2659.676 2,139,044.42
4.AW 5.9.7 Centering and shuttering including strutting, propping etc. and removal of form for :Stairs, (excluding landings) except spiral-staircases sqm 47.520 31,256.28
4.AX 5.9.14 Centering and shuttering including strutting, propping etc. and removal of form for :Extra for shuttering in circular work (20% of respective centering and shuttering items) sqm 5.000 307.95
4.AY 5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars kilogram 243226.622 21,805,266.66
4.AZ 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum cum 618.600 4,947,129.78
4.BA 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum cum 1167.350 11,767,063.10
4.BB 5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal 829.560 571,110.58
4.BC 6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) cum 139.274 927,321.11
4.BD 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) cum 827.101 6,855,302.57
4.BE 6.13.1 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) sqm 569.126 593,655.33
4.BF 6.15 Extra for providing and placing in position 2 Nos 6mm dia with stirrup. M.S. bars at every third course of half brick masonry. sqm 569.126 49,200.94
4.BG 7.38.1.1 Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. Granite stone of any colour and shade sqm 108.600 290,581.02
4.BH 8.2.2.2 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished machine cut granite for kitchen platforms, vanity counters, wondow sills, fascias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels.Granite black (area of slab over 0.50 sqm) Sqm 16.830 74,478.64
4.BJ 8.3.2 Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Granite work metre 25.680 10,756.07
4.BK 8.5 Extra for providing opening of required size and shape for wash basin/kitchen sink in kitchen plateform, vanity counters and similar location in granite work including necessary holes for pillar taps etc. including rubbing and polishing to cut edges etc. complete. each 24.000 19,395.60
4.BL 8.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make in all colours, shades except burgundy, bottle green, black of as approved by Engineer-in-charge in skirting, risers of steps and dado over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 Kg per sqm. including pointing in white cement mixed with pigment of matching shade complete. sqm 381.182 405,368.00
4.BM 9.20.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 145.200 448,101.72
4.BN 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). sqm 145.200 58,283.28
4.BP 9.62.1 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :300 x 16 mm Each 80.000 14,444.00
4.BQ 9.63.1 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm Each 152.000 11,346.80
4.BR 9.66.1 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete125 mm Each 80.000 2,816.00
4.BS 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete Each 57.000 58,462.05
4.BT 9.101.2 Providing and fixing aluminium hanging floor door stopper ISI marked Powder coated transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper Each 78.000 4,855.50
4.BU 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge. mtr 110.000 44,907.50
4.BV 9.139 Providing and fixing panic bar/latch (Double point) fitted with single body,Trim latch & lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer-in-charge,all complete. Nos 14.000 100,042.60
4.BW 9.142.1 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineerin- charge.5 mm thick factory made solid panel PVC door shutter of single piece extruded profile non decorative finished (Matt finished) Non decorative finish (matt finish) sqm 37.800 131,060.16
4.BX 9.161 Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). RM 42.000 75,224.10
4.BY 9.162 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating with vision panel confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mmthick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately). sqm 20.160 196,278.77
4.BZ 9.165.1 Providing and fixing bright/matt finished stainless steel handles of approved quality & make with necessary screws etc. all complete.125 mm Each 14.000 1,406.30
4.CA 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer sqm 9.450 88,804.96
4.CB 10.14.1.1 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb metre 293.900 130,638.55
4.CC 10.25.1 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 2978.040 304,504.59
4.CD 10.26.1 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube kg 486.000 76,374.90
4.CE 10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge kg 11961.150 1,240,371.26
4.CF 11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40mm thick cement concrete 1:2:4(1cement :2 coarsesand :4 graded stone aggregate 20 mm nominal size)and top layer 12 mm thick cement hardner consisting of mix 1:2 (1 cement hardnermix:2 graded stone aggregate 6mm nominal size) by volume,hardening compound mixed @2 litre per 50 kg of cement as per manufacturers specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. sqm 325.040 278,201.74
4.CG 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick sqm 803.944 1,372,010.83
4.CH 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. sqm 148.588 302,904.07
4.CJ 11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. Sqm 242.566 226,944.75
4.CK 11.41.2 Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades , laid on20mm thick cement mortar 1:4 (1 cement :4 coarse sand),including grouting the joints with white cement and matching pigments etc.,completeSize of Tile 600x600 mm Sqm 1014.278 1,436,876.93
4.CL 11.46.2 Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades , laid on20mm thick cement mortar 1:4 (1 cement :4 coarse sand),including grouting the joints with white cement and matching pigments etc.,completeSize of Tile 600x600 mm) Sqm 57.183 83,858.87
4.CM 11.56.1 Providing and laying Polished Granite stone flooring/skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite,Brown,Cat Eye or equivalent sqm 55.461 216,785.96
4.CN 12.21.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase metre 373.000 97,054.60
4.CP 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. each 15.000 3,999.00
4.CQ 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams. Each 9.000 431.10
4.CR 13.1.1 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) Sqm 150.000 44,227.50
4.CS 13.4.1 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) Sqm 50.000 15,362.50
4.CT 13.4.2 Finishing Work 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) sqm 4707.469 1,385,643.50
4.CU 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. sqm 8263.761 1,023,466.80
4.CV 13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. sqm 3026.180 1,397,641.23
4.CW 13.16.1 6 mm cement plaster on ceiling of mix :1:3 (1 cement : 3 fine sand) sqm 3556.292 899,919.69
4.CX 13.41.1 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer sqm 8263.761 1,343,274.35
4.CY 13.45.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) sqm 479.120 117,384.40
4.CZ 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) sqm 2547.060 413,515.19
4.DA 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture sqm 1500.000 287,100.00
4.DB 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth,dressing to camber and consolidations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. sqm 888.000 160,284.00
4.DC 16.2 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). cum 806.659 16,576.84
4.DD 16.3.1 Supplying and stacking at site.90 mm to 45 mm size stone aggregate cum 115.440 223,676.54
4.DE 16.3.2 Supplying and stacking at site 63 mm to 45 mm size stone aggregate cum 115.440 187,532.28
4.DF 16.3.3 Supplying and stacking at site 53 mm to 22.4 mm size stone aggregate cum 115.440 212,092.14
4.DG 16.3.6 Supplying and stacking at site Stone screening 13.2 mm nominal size (Type A) cum 66.600 124,209.00
4.DH M-16.3.9 (16.3.9+2.25) Filling with borrowed earth in foundation, trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 5 KM cum 806.659 708,649.93
4.DJ 16.3.10 Supplying and stacking at site Moorum cum 22.200 19,720.26
4.DK 16.4 Laying,spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness,hand picking,rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber,applying and brooming requisite type of screening/binding material to fill up interstices of coarse aggregate,watering and compacting to the required density. cum 435.120 376,726.90
4.DL 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line,level and urvature,jointed with cement mortar 1:3 (1 cement:3 coarse and),including making joints with or without grooves (thickness of joints except at sharp curve shall not more than 5mm),including making drainage opening wherever required complete etc. cum 20.079 172,951.47
4.DM M16.75(16.75-5.37.1+5.1.2+16.43B) Providing and laying C.C. pavement of mix1:1.5:3 concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge.(The pannel steel (channel) shuttering is inclusive not to be paid sepreately) Cum 71.300 653,033.14
4.DN 16.47.1 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out completeNew work (Two or more coats) sqm 713.000 113,010.50
4.DP 16.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin- Charge.80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. sqm 175.000 176,960.00
4.DQ 17.7.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the wallsWhite Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Each 29.000 86,002.40
4.DR 17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap Each 3.000 8,194.35
4.DS 17.10.1.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm Each 4.000 26,709.60
4.DT 17.28.2.2 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 40mm Dia Each 4.000 417.40
4.DU 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 22.000 31,045.30
4.DV 17.34.1 Providing and fixing toilet paper holder :C.P. brass Each 22.000 14,977.60
4.DW 17.70.1 Providing and fixing PTMT Bottle Trap for Wash basin.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. Each 22.000 7,152.20
4.DX 17.71 Providing & Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same material with snap fittings of approved quality and colour, weighing not less than 105 gms Each 18.000 2,633.40
4.DY 17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. each 3.000 39,109.65
4.DZ 17.80 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. each 12.000 84,053.40
4.EA 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. each 22.000 354,208.80
4.EB 18.7.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal OD RM 50.000 12,795.00
4.EC 18.7.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal OD RM 120.000 39,012.00
4.ED 18.7.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal OD RM 135.000 55,154.25
4.EE 18.7.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.32 mm nominal OD RM 165.000 82,656.75
4.EF 18.7.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.40 mm nominal OD RM 215.000 144,985.25
4.EG 18.7.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.50 mm nominal OD RM 25.000 23,175.00
4.EH 18.8.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc15 mm nominal OD RM 300.000 132,345.00
4.EJ 18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc20 mm nominal OD RM 50.000 25,687.50
4.EK 18.12.8 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.. 80 mm dia RM 100.000 91,910.00
4.EL 18.13.2 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore Each 1.000 1,513.70
4.EM 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore Each 10.000 5,323.50
4.EN 18.17.1A Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore Each 11.000 5,079.25
4.EP 18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore Each 6.000 3,539.40
4.EQ 18.17.3 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore Each 4.000 2,829.20
4.ER 18.17.4 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore Each 1.000 878.25
4.ES 18.17.6 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm dia Each 1.000 2,227.60
4.ET 18.18.1 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore Each 3.000 1,046.55
4.EU 18.19.6.1 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm dia Horizontal Each 1.000 3,134.80
4.EV 18.21.2.1 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length,15 mm nominal bore Each 63.000 5,367.60
4.EW 18.27.1 Providing & laying S & S cast spun pipes conforming to IS : 1536 class 'LA' including all fittings conforming to IS : 1538 e.g. bends, tees, reducers, blank flanges, tyton joints as per IS : 3114, effective proper connection (For External Sewer Line + Bypass line from Equalization tank to municipal sewer) complete i/c excavation/back filling, bed concrete, sand bed, painting two or more coats with synthetic enamel paint over a coat of primer.100 mm dia RM 100.000 120,195.00
4.EX 18.37.1 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 Each 1.000 9,020.80
4.EY 18.48 Providing and placing on terrace storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Litre 45000.000 436,500.00
4.EZ 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore Each 25.000 17,710.00
4.FA 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore Each 88.000 44,030.80
4.FB 18.58.1.2 Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia with 25 mm waste hole Each 50.000 2,262.50
4.FC 18.59.2 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :80mm dia Each 1.000 6,255.45
4.FD 18.60.1 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia Each 1.000 3,266.10
4.FE 18.61.1 Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 80 mm dia Each 1.000 4,135.75
4.FF 19.1.2 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm dia. RM 30.000 17,742.00
4.FG 19.1.3 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :200 mm dia. RM 160.000 132,864.00
4.FH M19.2.1 Providing and laying1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround pipe including as per standard design.100 mm dia UPVC pipe RM 120.000 81,306.00
4.FJ 19.2.1 Providing and laying 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.100 mm dia S.W. pipe RM 10.000 8,955.00
4.FK 19.2.2 Providing and laying 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.150 mm dia S.W. pipe RM 30.000 32,854.50
4.FL 19.2.3 Providing and laying 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.200 mm dia. S.W. pipe RM 160.000 204,272.00
4.FM M19.3.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches as per standard designUPVC pipes under floor, including shuttering and centering for: -160 mm dia RM 10.000 6,897.50
4.FN 19.3.4 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :250 mm dia. RM 200.000 188,780.00
4.FP 19.3.5 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :300 mm dia. RM 200.000 217,820.00
4.FQ 19.4.2.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100mm size 'P' typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 8.000 19,795.20
4.FR 19.6.3 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia RM 200.000 162,230.00
4.FS 19.6.4 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia RM 200.000 180,410.00
4.FT 19.6.5 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :450 mm dia RM 100.000 148,155.00
4.FU 19.7.1.1 Constructing water tight brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement :4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size). Foundation concrete 150 mm thick 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside and outside plastering 12 mm thick with cement plaster 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels and benching in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design,complete with SFRC cover Heavy duty of adequate size as per standard design and approved drawings . (Price shall include the, cost of excavation, back filling, disposal of surplus earth, dewatering & water proofing of manholes as directed at site & other associated civil works).Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 5.000 58,435.50
4.FV 19.7.2.1 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 3.000 73,217.70
4.FW 19.8.1.1 Extra for depth for manholes Size 90x80 cm :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 metre 1.000 8,127.45
4.FX 19.8.2.1 Extra for depth for manholes Size 12X90cm:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 metre 1.000 9,744.25
4.FY 19.9.1.1 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside rought cement planter 15 mm thick with CM 1:3 (1 cement:3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design. 0.91 m deep with S.F.R.C. cover and frame (heavy duty HD-20 grade designation) 560mm dia at top conforming to IS 12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) including excavation in all kinds of soil refilling centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately). With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 26.000 309,047.70
4.FZ 19.10.1 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 RM 7.000 48,907.60
4.GA 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. Each 135.000 65,758.50
4.GB 19.27.1 Constructing brick masonry road gully chamber 50 x 45 x 60 cm unit brick of class designated 75 in cement mortar 1:4 (1 cement :4 coarse sand) including 500 x 450 mm precast RCC horizontal grating with frame complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 30.000 167,683.50
4.GC 20.2.2 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).500 mm dia piles metre 2340.000 5,321,745.00
4.GD 20.3.1 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameterand length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles Mtr 1279.800 3,277,439.82
4.GE 20.6.1.1 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Initial test (Test Load 2.5 times the Safe capacity)Single pile upto 50 tonne Safe capacity per test 31.000 1,596,828.60
4.GF 20.6.1.2 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Initial test (Test Load 2.5 times the Safe capacity)Single pile upto 50 tonne Safe capacityRoutine test (Test Load 1.5 times the Safe capacity Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. per test 85.000 1,569,401.75
4.GG 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 3000.000 1,398,900.00
4.GH 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 3000.000 1,694,400.00
4.GJ 21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness sqm 500.000 662,775.00
4.GK 21.4.1 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, mbedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. Each 4.000 9,795.40
4.GL 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatmentand sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry sqm 138.322 71,457.15
4.GM 22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. sqm 1451.264 2,210,202.51
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 0.000 0.00
4.GN 5.28 Providing and fixing in position 12mm thick bitumen impregnated per cm fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. per cm per 100mtr length 100.000 56,725.00
4.GP 19.1.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm dia. RM 10.000 5,066.50
4.GQ 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge sqm 28.800 130,772.16
5.AA NS Supply and fixing of 304 grade stainless steel ball bearing hinges of size 125 x 89 x 3mm from Ingersoll Rand / Assa Abloy/Dorma / Marshall Nos 42.000 16,800.00
5.AB NS External Treatment on Retaining Wall: Providing and laying 1.6 mm thick, non perforated ,HDPE cross laminated film faced self adhesive bituminous waterproofing membrane Dr. Fixit Samshield XL 1500 over the PCC etc as complete. The elongation (L/T) % should be 230/180 as per ASTM D 882, Tensile strength (L/T) ( N/mSQM) should be 42/48 as per ASTM D 882, Tear Resistance (L/T) (N) 340/310 as per ASTM D 1004 , Puncture Resistance should be more than 220 N as per ASTM E 154 , Hydrostatic pressure more than 50 m as per BS EN 12390 ( Part 8 ), Water absorption @24 hrs (g/SQM) should be 0.14 % as per ASTM D 570 , Water vapor transmission (g/SQM/24 hours) should be less than 0.1 as per ASTM E 96 , Chemical resistance (pH) should be 2.5 – 11.5 as per ASTM D 543 and Crack bridging ability should be more than 1.5 mm as per ASTM C 836. sqm 914.620 1,097,544.00
5.AC NS Providing protection board of geodrain boad of 10mm thick fixed on to the membrane complete as per the specification and drawing. (In client's Scope) sqm 914.620 457,310.00
5.AD NS Termination at vertical Use a C- Shaped aluminium flashing strip or tuck it into a concrete wall of a groove of 12mmx12mm .T he aluminium flashing can be fitted to press the membrane into the groove and then be filled with a single component Dr. fixit PU sealant . sqm 914.620 640,234.00
5.AE NS Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors.110 mm (OD) x 110 mm (OD) Each 40.000 22,402.93
5.AF NS Providing, Fixing, testing and commissioning of UPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work.110 mm OD Each 20.000 13,320.00
5.AG NS Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection)32 mm RM 60.000 18,180.00
5.AH NS Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection)40 mm RM 35.000 11,425.89
5.AJ NS Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection)50MM RM 15.000 6,085.60
5.AK NS Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect.110 mm OD x 63 mm OD Each 10.000 3,760.00
5.AL NS Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.110 mm (OD) SWR Pipe RM 425.000 264,775.00
5.AM NS Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion and with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.160MM OD Per M 100.000 86,000.00
5.AN NS Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion and with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint 110 mm OD Per M 8.000 3,424.00
5.AP NS Providing and fixing forged brass auto air vent valve PN10 (10.00 Kg/cm2) rating including all fitting with ball valve & accessories.15 mm dia Each 2.000 3,000.00
5.AQ NS Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).65 mm dia Each 1.000 4,461.74
5.AR NS Constructing water tight brick masonry grease trap with first class bricks in cement mortar 1:6 (1 cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size, foundation concrete 150 mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement & M.S. foot rests including fixing in 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size), two brick masonry baffle walls each of 500 mm depth deep each of 115 mm thickness, 2 Nos C.I. double seal medium duty covers each of 450 x 450 mm size including excavation, backfilling & disposal of surplus earth with a lead upto 50m complete as per standard design.(Note: Cost shall include dewatering & water proofing of Grease trap as directed at site). Grease Trap (Size 1200 x 900 x 1000 mm overall depth). Each 1.000 35,000.00
5.AS NS RAIN WATER HARVESTING SYSTEM : Construction of rain water harvesting size 3m dia x 3.5m effective depth for the re-charging of storm water run off including the civil work with following specification [Construction of Chamber]. Set 2.000 1,200,000.00
DE-SILTING CHAMBER: 0.00
OIL AND GREASE SEPARATOR CHAMBER: 0.00
Providing and constructing oil and grease separator chamber 1200 x 2500mm x 2000-3700 mm depth with required depth inside with 75 class designated brick work in cement mortar 1:6 (1cement : 6 fine sand) with 560mm dia SFRC Heavy duty manhole cover (2Nos.) top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement foundation concrete 1:5:10 (1cement: 5 fine sand and 10 graded stone aggregate 20mm nominal size including two brick mansonary baffle walls, with necessary excavation, back filling and disposal of surface earth compete with inlet, outlet, PVC coated foot rest. 0.00
Drilling percolation borehole 200mm dia with reverse rotary method in all types of soil 40-45m depty including cost for mobilization of rig and making good the area upon completion of work. Contractor shall arrange for all necessary tools, water and consumable and laying for drilling. 0.00
Providing and laying pea gravel all around the casing pipe.refer schematic section proided in side plan. 0.00
160 mm dia slotted UPVC pipe of 6 Kg/cm2 - 35 m -40m or as per site sub-strata or set as per direction of Engineer- in charge.refer schematic section proided in side plan. 0.00
160 mm dia UPVC blind pipe of 6 Kg/cm2. 0.00
RAIN WATER HARVESTING WELL FILTRATION CHAMBER: 0.00
Providing and constructing rain water harvesting well/filtration chamber of size 3m dia x 3.5m eff. depth inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including 500mm depth. Boulder 10-20mm, 500mm depth, gravel 5-10mm size, 500mm depth coarse sand 1.5-2.0mm including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm dia weep holes @500mm c/c to be provided 1200 c/c above the bottom of wall, 100mm C.I vent pipe -2m height with cowls. 0.00
Rate shall include excavation, back filling and all other operations necessary for completing the job. 0.00
PUDDLE FLANGE FOR WATER TANKS: Providing and fixing M.S fabricated epoxy coated(two layers) galvinised coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size upto 150 mm dia & 7.1 mm thick mm plate for pipe dia above 150 mm dia including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground/ overhead tanks.) 0.00
5.AT NS 25 mm dia Each 8.000 17,973.15
5.AU NS 50 mm dia Each 3.000 11,344.38
5.AV NS 65 mm dia Each 4.000 17,628.32
5.AW NS 80 mm dia Each 6.000 34,201.06
5.AX NS 100 mm dia Each 2.000 12,478.00
5.AY NS Providing and Fixing in position Hindware make or equivalent CP Grab Bar with wall flanges 600 mm to wooden cleats with C.P. brass screws complete in all respects. Each 9.000 27,000.00
5.AZ NS Providing, Fixing, testing and commissioning of C.P. brass wall/counter mounted Single Lever sink mixer with C.P. wall flange, overhead swinging spout/goose neck complete as required and making good Including necessary wall cutting / chasing and making good, as required of make parryware diamond range or equivalent as per direction of Engineer in Charge. HINDWARE make - ELEMENT (Cat No. F360027) / Equivalent Each 4.000 18,000.00
5.BA NS Supply and fixing HINDWARE make or equivalent Health Faucet with 8 mm dia, flexible tube with wall hook and Angle stop cock with wall flange . Etc all as directed by Engineer In-Charge.HINDWARE make Health Fauce - 1.25 Mtr. long (Cat No. F160013)/ Equivalent Each 22.000 39,600.00
5.BB NS Providing and Fixing in position best HINDWARE make Vitreous Chinaware partition slab for urinals, size 690X165X325mm, all as specified and directed. (Cat. No. 61001 of HINDWARE make) / Equivalent Each 12.000 39,600.00
5.BC NS Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. ( Make - Parry Ware Product Code- C500339): Capacity 25 litres. Each 1.000 10,100.00
5.BD NS Providing and fixing G.I. Vent Pipe class 'B' (medium duty) for R.C.C water storage tanks comprising of 600 mm long vertical pipe, return bend with mosquito grating & cast brass perforated coupling including all associated civil work.100 mm dia Each 4.000 10,000.00
5.BE NS Providing and fixing of mosquito overflow grating /Jali of the following diameters including all fitings & accessories :-100 mm dia Each 4.000 2,600.00
Name of Project : PROPOSED INDUSTRIAL TRAINING INSTITUTE FOR POWERGRID AT GORAKHPUR
BOM FOR WTP AND STP.
RFX Description Unit QTY
Water Supply, Drainage Pumps & Water Treatment Equipments
3.AA NS Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Filter Feed Pump (Dom. Water) at Water Supply Pump Room Set 1.00
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 2.0 LPS
3.AB NS Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Raw Water Transfer Pump to STP at Pump Room Set 1.00
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 1.0 LPS
3.AC NS Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Irrigation Pump at STP Pump Room Set 1.00
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 4.0 LPS
3.AD NS Providing, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 100 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects,
including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Domestic Water Supply at Water Supply Pump Room Set 1.00
Set of Two Pumps (1 Working+ 1 Standby)
Capacity 2.5 LPS
3.AE NS Providing, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 100 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects,
including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Flushing Water Supply at STP Pump Rm Set 1.00
Set of Two Pumps ( 1 Working+ 1 Standby)
Capacity 1.5 LPS
3.AF NS Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge.
(Pumps shall be installed in a set of two pumps One working and One standby)
Pump Room Drainage Pumps Set 1.00
(Pumps to be suitable to handle solids upto 30 mm size)
Capacity - 4.0 LPS (Each)
3.AG NS Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
Dual Media Filter For Domestic Water Supply Each 1.00
Capacity- 7200 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
3.AH NS Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
Activated Carbon Filter For Domestic Water Supply Each 1.00
Capacity- 7200 LPH
Filtration rate- 14000 LPH/Sqm.
Filter dia approx. - 1000 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
3.AJ NS Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects.
Chlorination of Domestic Water Each 1.00
3.AK NS Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top or bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
Electric Panel For Water Supply Pumps at Water Supply Pump Room
1 No. 150 amps TPN MCCB with the following accessories:
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.
Three phase indicating lights.
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 200 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.
Four 25 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
01 Nos. TPN MCCB of 63 A with 25 KA service breaking capacity for domestic water hydropneumatic pumps. (Only connection to inbuilt panel of Domestic water hydropneumatic system)
4 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 5 HP pump .
4 Nos. rotary selector switch for selecting mode of operation i.e. auto/manual/off.
4 Nos.cyclic relay for automatic duty changeover of pumps.
4 No. single phase preventors.
4 Nos. square flush mounting 0-30 amps scaled ammeters with three way and OFF selector switch.
Space for 3 Nos. Level Controllers.
Switchgear shall be suitable for the HPS of various motors.
2 Nos. 32 Amp. TPN MCB Spare.
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.
Motor control centre as described above Each 1.00
3.AL NS For Drainage Sump Pump
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top or bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
One incoming main MCCB unit of 63 amps rating.
Copper bus bar is separate chamber fully taped of 100 amps capacity.
Two MCB units of 25 amps
Two fully automatic DOL starters with push buttons and on/off indicating lights.
One rotary duty selector switch
Two manual/auto/off switches.
Two single phasing presenters.
One panel type voltmeter with rotary selector switch for reading voltage between phases.
Two ampere meters one for each motor.
Three neon phase indicating lights on the incoming mains.
Space for one liquid level controllers.
All internal wiring colour coded from incoming mains to various switchgear, starters, meters, indicating lamps and bus bar with a changeover facility to run each pump alternatively with an alarm bell in case of both pump’s running at one time. Switchegear offered must be compatible with the HP of the motors offered.
Motor control centre as described above Each 2.00
3.AM NS Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required.To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.For Water Supply Pump: Each 2.00
3.AN NS Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required.To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing..For Sump Pumps:
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
3.AP NS 50 mm dia MTR 25.00
3.AQ NS 65 mm dia MTR 35.00
3.AR NS 80 mm dia MTR 45.00
3.AS NS 100 mm dia MTR 20.00
Providing & fixing butterfly valve tested to a pressure not less than 25 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required.
3.AT NS 50 mm dia Each 5.00
3.AU NS 65 mm dia Each 10.00
3.AV NS 80 mm dia Each 6.00
3.AW NS 100 mm dia Each 2.00
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 25 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required.
3.AX NS 50 mm dia Each 4.00
3.AY NS 65 mm dia Each 6.00
3.AZ NS 80 mm dia Each 2.00
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm.
3.BA NS 50 mm dia Each 4.00
3.BB NS 65 mm dia Each 4.00
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.
3.BC NS Power cable Copper 3 core 10 sq.mm MTR 25.00
3.BD NS Power cable Copper 3 core 6 sq.mm MTR 35.00
3.BE NS Power cable Copper 3 core 4 sq.mm MTR 35.00
3.BF NS Control cable copper 2 core 1.5 sq.mm MTR 75.00
Providing and fixing CI Y type suction strainer with gunmetal or brass internal parts installed outside water tanks.
3.BG NS 100 mm dia. Each 2.00
Sewage Treatment Plant
3.BH NS Designing, Supply, installation, Testing and commissioning of complete mechanical and electrical Items with stand by pumps as mentioned in the List of Mechanical equipment’s of the STP-25 KLD based on MBBR technology. (Excluding civil works) Job 1.00
List of Electro-Mechanical Equipments Unit Qty
Bar Screen Nos 2
Level Switch Set 1
Sewage lifting pump Nos 2
Plant Room Sump Pump Nos 2
Air Blower Nos 2
Air dispersion system
Fine bubble diffuser Lot 1
corse bubble diffuser Lot 1
Air piping Lot 1
Sludge recirculation pump Nos 2
Filter press (Manual) Nos 1
Screw pump Nos 2
MBBR media Lot 1
Tube settler media Lot 1
Filter feed pump Nos. 2
Multigrade Filter No 1
Activated carbon filter No 1
Pressure guage lot 1
Dosing pump No 1
Piping & Fitting Lot 1
Electrical control panel No 1
Electro Magnetic Flow Meter No 1
Cable & Cable tray No 1
Ulta violet (UV) System No 1
MBBR 1 & 2 Tank (MSFRP) No 2
Tube Settler Tank (MSFRP) No 1
Filter Feed Tank (MSFRP) No 1
Treated Water Storage Tank (MSFRP) No 1
Screen cum Oil & grease chamber No 1
Oil & Grease chamber No 1
Collection Tank No 1
Plant Room No 1
Foundation for equipment No 1
BOM FOR QUANTITIES FOR FIRE PROTECTION WORKS
RFX DSR(for wet riser & sprinkler system)-2019 Description of Item Unit
2.AA 4.2 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
450 lpm at 35 m Head Set 1
PIPES & ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
2.AB 7.1 25 mm dia m 10
2.AC 7.6 80 mm dia m 30
2.AD 7.7 100 mm dia m 80
2.AE 11.5 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
100 mm dia Set 3
2.AF 14.5 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100mm dia Set 1
2.AG 15.2 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
100 mm dia Each 1
2.AH 17.2 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
2.AJ 22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each 1
2.AK DSR E & M-16.8 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required Each 1
2.AL NS Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m ) Each 6
2.AM NS Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2.
2.AN NS Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects.
Power cable 3 core 16 sq mm aluminium conductor armoured cable. Mtr. 10
2.AP NS Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas)
Capacity 4.5 Kg. Each 6
2.AQ NS Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas)
Capacity 6.0 Kg. Each 30
PROPOSED ITI GORAKHPUR
Sl. No. DSR 2018/ MR Item No. RFX sl. No. Description Unit Qty.
1 SUB-HEAD I: HT & LT Cables and Terminations
a) MR 1.AA Supply of cable XLPE -PVC insulated PVC sheathed galvanised steel strip armoured electric power cable with aluminium conductor 11000 volt grade of size 3C X 95 sqmm. Meter 100
b) DSR-2018 8.1.1 1.AB Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 120 Sq-mm Metre 70
c) DSR-2018 8.3.1 1.AC Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/STONE WARE / METAL pipe as required. Upto 120 sq-mm Metre 30
d) DSR-2018 10.1.2 1.AD Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 sqmm Set 2
e) DSR-2018 10.2.2 1.AE Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 95sq. mm Set 2
Total of Subhead-I Carried to Summary
2 SUB-HEAD II: HT & LT Panels
MR 11 KV SWITCHGEAR PANEL :
2.1 Supply, unloading, storing, handling, installation, testing and commissioning of 11 KV 350 MVA,indoor, horizontal isolation, horizontal, drawout, Vacuum circuit breaker, Single Panel switchboard fabricated out of minimum 2 mm thick CRCA sheet as per specification. The panel shall be complete with all accessories & cable termination boxes suitable for 1R x 3C x 300 sqmm XLPE for incoming & 1R x 3C x 300 sqmm each for outgoing.
All Meters shall be digital type & 0.5 accuracy class.
All Indicating lamps shall be LED type.
All C.T. / P.T. shall be cast resin.
The switchboard shall consist of :
a) Incoming & Outgoing :
One (1) No. incomer & outgoing, equipped with the following :
11 KV, 630 Amps, 350 MVA, 18.4 kA Electrically operated horizontal draw out horizontal isolation Vacuum Circuit Breaker complete with anti pumping device, trip free features and 6NO + 6 NC directly breaker control aux. switch contacts.
- TNC switch with lost motion device.
- One (1) Set of 11 KV grade indoor surge arrestor as per specifications and as required..
- One (1) Set of cast resin drawout type potential transformer mounted over separate withdrawable trolley with fuse in primary & secondary, ratio: - 11KV/1.732 / 110/1.732 volts, 100 VA burden per phase and accuracy class 0.5.
- One (1) Set of cast resin, protection class 5P10, ratio 300/160/5-5A, 15VA current transformer for protection.
- One (1) Set of cast resin, accuracy class-0.5, 15 VA, current transformer for instrumentation (C.T. ratio as above).
- Triple pole IDMTL O/C and E/F relay (51 & 51N similar to CDG-31 of M/s ALSTOM or equivalent) complete. Two (2) outer elements connected for over current & middle element for earth fault protection.
● Over current setting : 50% - 200%
● Earth current setting : 10% - 40%
- One (1) No. Digital Multifunction Meter, with RS-485 port suitable for measurement of voltage, current, Power factor, frequency, Power (KW, KVA, KVAR), Energy (KWH, KVAH, KVARH) and Harmonics (EM-6434 of Conzerv or equivalent).
- 24V DC Shunt Trip Coil.
- 240V AC 1 phase spring charging motor.
- Set of phase indication lamps with (Red, Yellow and Blue) with control SPMCB.
- Set of Red/Green indicating lamp for close & open position.
- Amber indicating lamp for Auto Trip.
- Clear indicating lamp for trip circuit healthy.
- Mechanical ON/OFF/Trip indication.
- Blue indicating lamp for spring charged.
- Strip heater to prevent absorption of moisture.
- Panel illumination lamp.
One (1) No. 24V, Power Pack of suitable back-up rating for indications, annunciations and trip coil operations as per specification and as required.
- TNC switch with lost motion device.
- Set of 15/5A, cast resin, protection class 5P10, 15VA current transformer for protection.
- Set of 15/5A, cast resin, accuracy class-0.5, 15VA current transformer for instrumentation.
- Triple pole IDMTL O/C and E/F relay with instantaneous high set over current and earth fault protection 50, 50N, 51 & 51 N (similar to CDG-61 of M/s AREVA or equivalent) having settings range.
i) IDMTL Setting :
- Over current setting : 50% - 200%
- Earth current setting : 10% - 40%
ii) Instantaneous Setting :
- Over current setting : 500% - 2000%
- Earth current setting : 100% - 400%
- Auxilary relay similar to VAA 33 of Areva or equivalent.
- Four (4) Window, Audio / visual annunciation system complete with Transformer trouble & protection trip, LT breaker trip annunciation. It shall be possible to acknowledge the fault from remote, control room. Necessary provision to be left in the acknowledgement circuit for this purpose.
- HT Breaker Trip
- 240V, AC 1-phase spring charging motor.
- 24V DC shunt trip coil.
- Digital Ammeter ( 0-160A) with selector switch.
- Set of Red/Green indicating lamp for close & open position.
- Amber indicating lamp for Auto Trip.
- Clear indicating lamp for trip circuit healthy.
- Mechanical ON/OFF/Trip indication.
- Blue indicating lamp for spring charged.
Panel illumation lamp ----- RATE
- Strip heater to prevent absorption of moisture.
- Service, isolation, test indication.
- Provide Earthing Switch.
1.AF HT Panel Complete as described above Set 1
2.2 MR 11KV/433V TRANSFORMER
Supply and installation testing & commisioning of 200 kVA transformer step down outdoor type complete with standard fittings HT 11 KV 3 phase 4 wire copper wound, delta/star connected (vector group-DYn -11), On load Tap Changer on HV side , oil immersed, naturally oil cooled (ONAN), Distribution transformer complete with following:-
Silica gel breather with connecting pipe and oil seal.
Air release plugs.
Pressure release device. Explosion vent, should be double diaphragm type.
150mm dial magnetic oil level gauge with low level alarm contact.
150 mm dial oil temperature indicator with maximum reading pointer and electrically separate contacts for trip and alarm.
150 mm dial winding temperature indicator with maximum reading pointer and electrically separate sets of contacts for trip and alarm.
Thermometer pockets.
Oil conservator with filter cap, drain plug and plain oil level gauge (with coloured prismatic front).
Double float Buchholz relay with gas release cock, shut-off valve on either side and separate sets of contacts for trip and alarm.
Sampling valve/ Filter valve with threaded adopted (top and bottom).
Drain valve with threaded adopted.
Jacking pads, handling and lifting lugs.
Cover lifting eyes.
Bi-directional rollers and skids( 4 Nos. Roller)
Radiators (Detachable type).
Clamping devices.
Two grounding pads.
Remote tap changer control panel.( RTCC)
Weatherproof marshalling box for housing control equipment and terminal connections.
Rating and terminal marking plates.
LT Neutral bushing with 40x6 cu flat suitably supported
Outdoor HT cable box (Detachable type) suitable to terminate 3C-150 sq. mm 11kV HT cable.
LT side cable box suitable for 2 Nos. 3.5C x 150 Sq. mm Al Arm LT Cables
1.AG 200 KVA Transformer as per above SET 1
3 MR MAIN LT PANEL (35 kA)
630 amps 4P electrically operated fully drawout type air circuit breaker as per specification and with following accessories. Transformer Supply Feeder
630 amps 4P electrically operated fully drawout type air circuit breaker as per specification and with following accessories. DG Supply Feeder
b) Metering & indication for Transformer Supply incoming breaker:
Breaker shall be provided with :
i) One(1) No. multifunction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).
ii) One (1) set 3 Nos. CTs of ratio 630/5A,15VA, Class 1.0 as required.
iii) One (1) set of 250/5 A, C.L 1.0 CTs for input to APFC relay.
iv) One set (3 Nos) phase indication lamp with backup SP MCB.
c) Protection Relays & Interlocking for transformer breaker:
Transformer breaker to be provided with :
i) One(1) set of multifunctional protection relay suitable for 50, 50N, 51, 51N, 27, 59 and 95. with one set of 630/5 A, 5 P10 CTs .
d) Metering & Indication For DG supply breakers:
Each Breaker shall be provided with:-
i) One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, hour run, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).
ii) Two (2) set 3 Nos. CTs of ratio 630/5A,15VA, Class 1.0 as required.
ii) Two (2) set 3 Nos. CTs of ratio 250/5A,15VA, Class 1.0 as required.
iii) Volt & Ammeter of battery/Battery charger system as per specification.
iv) Three (3) nos. phase indicating lamps with backup SP MCB.
v) Load on DG Set indication.
vi) Battery charger and its indication as per specifications.
vii) One no. 12 window Audio/visual annunciator system complete with hooter, Ack, test & Reset PBs for annunciation of low lube oil pressure, high water temperature, Engine over speed, Electrical prot trip, Engine fail to start, low fuel level complete with power supply arrangements.
e) Protection Relays & Interlocking for DG Supply Breaker
Each DG breaker shall be provided with
i) One(1) set of multifunctional protection relay suitable for 50V, 50N, 51V, 51N, 32, 27, 59 and 95. with one set of 630/5 A, 5 P10 CTs .
ii) One(1) set of multifunctional protection relay suitable for 50V, 50N, 51V, 51N, 32, 27, 59 and 95. with one set of 250/5 A, 5 P10 CTs .
1 Above BOQ is for the purpose of scope indentification. However, all items required for sucessful operation, protection inter locks as per operation shceme thru potential free contacts shall be provided in sufficient Nos. as required.
2 Sufficient No. of contacts terminals shall be provided in the panel as required for necessary remote operation and indications etc.
3 Operation interlocks as per specification & drawings indicating sufficient nos. of potential free contacts for interlocking/indication annunciation/ control etc shall be provided by the bidder as required.
f) DG Control System (AMF Panel) :
Each DG breaker Cubicle shall be provided with various components associated with AMF panel and shall comprise of:
The features of AMF logic, Auto/manual/test, start/stop, EM stop operation including 3 attempt start feature, idle running timer, resumption of power supply after some time when EB supply has come back, shall be provided and integrated in the DG breaker cubicle. Set of relays, timer, Aux. Contactor etc as required for meeting the requirement of successful AMF shall be provided.
AMF operation through PLC with all necessary features for manual operation. (to be done when PLC is not available or out of circuit).
1 BOQ given above is for a composite panel identifying the scope of supplies. However, bidder shall include all such components as are necessary for a successful and safe AMF scheme in both manual as well as on auto. DG control panel shall be integrated in the SECTION # 1 & 2.
2 Above BOQ is only for the purpose of scope identification. However all item required for protection interlocks as per operation scheme through potential free contacts for operation & control shall be provided in sufficient number as required.
3 Necessary Co-ordination with the DG Vendor for successful operation shall be done by Panel Vendor without any extra cost.
4 Required interlock should be provided so that transformer and DG supply are not paralleled.
b) Bus Coupler :
One (1) No. 630 Amps, 415 V, 35kA four pole ACB with O/C, E/F protection etc complete as required to be interlocked with the incommers to allow closing of breakers in such a way that either transformer or DG Sets supply can be fed to the buses in all operating condition and necessary interlocking can be achieved as per approved SLD.
1 No. 800A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35kA. Neutral busbar shall be of 100% capacity.
Aluminium Bus bar with colour coded, heat shrinkable sleeves. (with 100% neutral). Separate earth Bus of 40 x 6 mm Aluminium shall be provided.
Each outgoing feeder shall consist of following:
Ammeter each with selector switch & one set of CTs
1 Nos. (0-500A) Volt Meter.
1 Sets supply available indicating lamps with control MCBs.
R-Y-B and ON/OFF indication lamps for incomer
2 Nos. 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current
1 No. 200 Amps TP Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current for capacitor panel.
1 No. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current .
3 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current .
6 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current
1.AH MAIN LT PANEL described as above complete with specifications and enclosed SLD No. 1
4.2 MR CAPACITOR PANEL 70 kVAR ( 35 kA)
Incoming breaker already taken in LT Panel hence not required here.
3 Set of 200 /5A for , CL-1.0, 15VA measuring CTs for Metering
Square flush mounted digital Ammeter of 96 mm sq. scaled 0-200 amps with 3 way and OFF selector switch
1 Set of phase indicating lamps with MCB.
Terminals to receive XLPE insulated cable
8 step APFCR relay microprocessor based to sense and monitor the system power factor and provide impulses for operation of 6 sequential capacitors circuits
Power factor meter ( digital )
250A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.
2 Nos. 63 A TP MCCB each complete with 80A AC 3 duty TP contactor (suitable for automatic switching of 25 kVAR Capacitor bank) with indicating lamps to give status of circuit , 25 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required
2 No. 32 A TP MCCB each complete with 40A AC 3 duty TP contactor ( suitable for automatic switching of 10 kVAR Capacitor bank) with indicating lamps to give status of circuit , 10 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required
1.AJ 70 kVAR Capacitor Panel as described above complete with specifications and enclosed SLD No. 1
3.1 MR MDB-1 (Lighting & Power) Ground Floor
1 Nos. 200A, FP MCCB with Thermal Magnetic based release having overload and short circuit protection. (Ics=100% Icu)
Metering, Indication & Protection:
a 1 Nos. (0-200A) Ammeter each with selector switch & one set of CTs of ratio 200A/5A, CL 1.0, 15 VA.
b 1 Nos. (0-500A) Volt Meter.
c 1 Sets supply available indicating lamps with control MCBs.
d R-Y-B and ON/OFF indication lamps for incomer
250A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.
a 13 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current .
b 3 No. DOL Starter ,suitable for 5.0 Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Starter Near Water Lifting Pumps)
c 3 Nos. 25A TPN MCCB for Water Lifting Pumps.
d 2 Nos. 63A TPN MCCB Spare
1.AK MDB-1 (Lighting & Power) Ground Floor complete described as above as per SLD. Nos. 1
1.3 MR MDB-1.2 UPS (Ground Floor)
1Nos. 100A, DP MCCB with Thermal Magnetic based release having overload and short circuit protection. (Ics=100% Icu)
Metering, Indication & Protection:
a 1 Nos. (0-100A) Ammeter each with selector switch & one set of CTs of ratio 100A/5A, CL 1.0, 15 VA.
b 1 Nos. (0-100A) Volt Meter.
c 1 Sets supply available indicating lamps with control MCBs.
d R-Y-B and ON/OFF indication lamps for incomer
150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 20 kA. Neutral busbar shall be of 100% capacity.
a 3 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current .
b 2 Nos. 40 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current
1.AL MDB-1.2 UPS (Ground Floor)) complete described as above as per SLD. Nos. 1
EXTERNAL FEEDER PILLAR (External Lighting)
Design, fabrication, supply , Installation , testing and commisioning of Feeder Pillar fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door with reinforcement of suitable size angle iron, channel 'T' irons and / or flats wherever necessary. Cable gland plates shall be provided at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications with 2 coats of PU paint primer and final approved shade of PU paint coating. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels.
Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels.
1 no. 63 Amp TPN MCB ( Type C Motor Duty)
1 set of phase indicating lamps with MCB.
100 Amp FP aluminium busbars (Current Density 1A/Sq.mm) with 100% neutral.
1 Nos. 40A 4P MCB
3 Nos. 25A DP MCB
1 No. 40A FP MCB Complete with 1 no 24 hrs programmable timer & contactor for automatic operation of external lighting and with 4 nos. 10A/20A/25A amp 4P MCB, 10 KA with thermal magnetic protective releases as outgoings for external lighting
1.AM Feeder Pillar as Described Above complete. No. 1
Total of Subhead-II Carried to Summary
3 SUB-HEAD III: LT CABLES
b) MR 1.AN 1.1kV 3.5 core, 300 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor RM 80
e) MR 1.AP 3.5 core, 150 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor RM 100
e) MR 1.AQ 3.5 core, 70 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor RM 75
h) MR 1.AR 4 core, 25 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor. RM 165
i) MR 1.AS 4 core, 16 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor. RM 160
MR 1.AT 4 core, 10 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor. RM 100
k) MR 1.AU 3C-6.0Sq. mm Copper Armoured cable RM 75
DSR-2018 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
b) 7.5.1 1.AV Upto 35 sq. mm RM 500
7.5.2 1.AW Above 35 sq. mm and upto 95 sq. mm RM 75
c) 7.5.3 1.AX Above 95 sq. mm and upto 185 sq. mm RM 100
d) 7.5.4 1.AY Above 185 sq. mm and upto 400 sq. mm RM 80
2.1b Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering
7.4.1 1.AZ Upto 35 sq. mm RM 200
7.4.2 1.BA Above 35 sq. mm and upto 95 sq. mm RM 35
7.4.3 1.BB Above 95 sq. mm and upto 185 sq. mm RM 60
7.4.4 1.BC Above 185 sq. mm and upto 400 sq. mm RM 30
DSR-2018 Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.
b) 9.1.30 1.BD 3.1/2 core 300 sq. mm. Set 2
e) 9.1.26 1.BE 3.1/2 core 150 sq. mm. Set 4
g) 9.1.24 1.BF 3.1/2 core 95 sq. mm. Set 2
h) 9.1.23 1.BG 3.1/2 core 70 sq. mm. Set 2
k) 9.1.20 1.BH 3.1/2 core 25sq. mm. Set 8
l) 9.1.33 1.BJ 4core 16sq. mm. Set 8
9.1.32 1.BK 4core 10sq. mm. Set 12
q) M9.1.7 1.BL 3core 6sq. mm. Set 6
a) DSR-2018 4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032)
c) 4.1.15 1.BM 750 mm width X 75 mm depth X 2.0 mm thickness RM 50
4.1.6 1.BN 450 mm width X 50 mm depth X 2.0 mm thickness RM 20
f) 4.1.4 1.BP 300mm width X 50mm depth X 1.6 mm thickness RM 20
4.1.2 1.BQ 150mm width X 50mm depth X 1.6 mm thickness RM 20
Total of Subhead-III Carried to Summary
4 SUBHEAD-IV INTERNAL WIRING AND FINAL DISTRIBUTION BOARDS
1.1 Note:- Rates of only ISI marked M.S. conduit, FRLS PVC insulated copper conductor single core cables, moulded plate type switches in passivated box and FRLS PVC insulated earth wire have been taken in the following items unless otherwise specified and as per specification.
DSR 2018 1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.2 1.10.3 1.BR Group - C Point 305
DSR 2018 1.55 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.3 1.55.3 1.BS Group- C Point 345
DSR 2018 1.11 1.BT Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Point 24
DSR-2018 1.14.2 1.BU Wiring for light / power plug point with 2 x 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 2.5 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 400
DSR-2018 1.14.3 1.BV Wiring for light / power plug point with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 2000
DSR 2018 1.14.4 1.BW Wiring for light / power plug point with 2 x 6 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 6 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Metre 50
DSR-2018 1.31 1.BX Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required. Each 94
DSR-2018 1.32 1.BY Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required. Each 118
DSR-2018 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
1.BZ b) 20A, 3 pin socket outlet controlled by 20A 2P MCB Each 4
DSR-2018 1.21 Supplying and fixing of following size of medium class PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.
1.21.1 1.CA 20mm dia Metre 50
1.21.2 1.CB 25mm dia Metre 50
1.21.3 1.CC 32mm dia Metre 50
2.1 DSR-2018 1.14 Wiring for circuit/ submain wiring alongwith earthfollowing sizes of FRLS PVC insulated copper conductor, single wire with the core cable in surface/ recessed medium class PVC conduit as required.
1.14.1 1.CD 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 500
FINAL DISTIRIBUTION BOARD
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.4.1 1.CE 4 way (4 + 12), Double door Each 4
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.1 1.CF Single Pole Each 48
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.2 1.CG 63A Each 4
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.14.3 1.CCH 63A Each 12
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.4.2 1.CJ 6 way (4 + 18), Double door Each 8
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.1 1.CK Single Pole Each 144
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.2 1.CL 63A Each 8
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.14.3 1.CM 63A Each 24
2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2.5.3 1.CN 12 way (4 + 36), Double door Each 3
2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15.3 1.CP 63 A Each 3
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1 1.CQ 40A Each 3
2.13.2 1.CR 63A Each 3
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.5 1.CS Triple pole and neutral Each 36
2.23 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
2.23.1 1.CT For 6 way, Double door SPN MCBDB Each 2
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.2 1.CU Single Pole and neutral Each 16
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1 1.CV 40A Each 2
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Total of Subhead-IV Carried to Summary
5 SUBHEAD-V SUPPLY AND INSTALLATION OF LIGHT FIXTURES & FANS
Supply and installation of of following type LED/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips /Bajaj/ Wipro/Insta/Forus)
MR 1.CX Supply, Installation, Testing & commissioning of surface/suspended 4' LED luminaire.Extruded aluminium housing fitted with engg. Plastic end caps.Opal diffuser provides smooth light distribution LED populated on PCB comprising of LED’s connected in series parallel. It has a system wattage of 36W providing a luminaire efficacy of >100 lm/W, operating range 150 – 275V AC supply, voltages, LED Colour Temp. from 6500°K ±300°K with PF>0.95 and THD<15%, CRI <80. The system level lifetime is around 50,000 burning hours with 70% percent lumen maintenance. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire and LM 80 for LED source Each 7
MR 1.CY Supply, Installation, Testing & commissioning of surface/suspended 4' LED luminaire.Extruded aluminium housing fitted with engg. Plastic end caps.Opal diffuser provides smooth light distribution LED populated on PCB comprising of LED’s connected in series parallel. It has a system wattage of 2X28W providing a luminaire efficacy of >100 lm/W, operating range 150 – 275V AC supply, voltages, LED Colour Temp. from 6500°K ±300°K with PF>0.95 and THD<15%, CRI <80. The system level lifetime is around 50,000 burning hours with 70% percent lumen maintenance. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire and LM 80 for LED source Each 54
MR 1.CZ Supply, Installation, Testing & commissioning of surface/suspended 4' LED luminaire.Extruded aluminium housing fitted with engg. Plastic end caps.Opal diffuser provides smooth light distribution LED populated on PCB comprising of LED’s connected in series parallel. It has a system wattage of 28W providing a luminaire efficacy of >100 lm/W, operating range 150 – 275V AC supply, voltages, LED Colour Temp. from 6500°K ±300°K with PF>0.95 and THD<15%, CRI <80. The system level lifetime is around 50,000 burning hours with 70% percent lumen maintenance. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire and LM 80 for LED source Each 164
MR 1.DA Supply of Recssed mounted downlighter white CRCA powder coated LED luminaire with total system wattage 18W covered by acrylic diffuser, die cast aluminium housing, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficasy >= 100lm/W and minimum system lumens 1800. Each 159
MR 1.DB Supply, Installation, Testing & commissioning of surface/suspended 4' LED luminaire.Extruded aluminium housing fitted with engg. Plastic end caps. Arrylic diffuser provides smooth light distribution LED populated on PCB comprising of LED’s connected in series parallel. It has a system wattage of 18W providing a luminaire efficacy of >100 lm/W, operating range 150 – 275V AC supply, voltages, LED Colour Temp. from 6500°K ±300°K with PF>0.95 and THD<15%, CRI <80. The system level lifetime is around 50,000 burning hours with 70% percent lumen maintenance. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire and LM 80 for LED source Each 21
MR 1.DC Supply of surface mounted down white CRCA powder coated LED luminaire with total system wattage 9W covered by acrylic diffuser, die cast aluminium housing, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficasy >= 100lm/W and minimum system lumens 1500. Each 75
MR 1.DD Supply of surface mounted Bulk Head Light white CRCA powder coated LED luminaire with total system wattage 9W covered by acrylic diffuser, die cast aluminium housing, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED shall be SMD type, fixture should have minimum efficasy >= 100lm/W and minimum system lumens 1000. Each 14
4.1.6 CEILING FAN
MR 1.DE Supply of 1200mm Dia ceiling sweep Fan with all accesries. Each 161
DSR-2018 1.25 1.DF Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required Each 161
DSR-2018 1.45 1.DG Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 161
MR 1.DH Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required. Each 7
MR 1.DJ Supply and installation of 230 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required. Each 7
MR 1.DK Extra for fixing the louvers/ shutters complete with Frame for a exhaust fan of all sizes Each 14
Total of Subhead-V Carried to Summary
6 SUB-HEAD VI: TELEPHONE, DATA & PA SYSTEM
1 MR Providing, fixing, connecting and testing of following pair solderless telephonetag block, with powder coated box (Krone make ) of required size box with hinged lockable cover and clamps for dressing of wires etc as required.
1.2 MR 1.DL 100 Pair box Each 1
1.3 MR 1.DM 50 Pair box Each 1
1.4 MR 1.DN 20 Pair box Each 1
1.5 MR 1.DP 10 Pair box Each 1
2 MR Supply and laying of following 0.61mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in concealed/ surface system complete as required
2.1 MR 1.DQ 100 pair Cable Mtrs 50
2.3 MR 1.DR 20 pair Cable Mtrs 20
2.4 MR 1.DS 5 pair Cable Mtrs 25
2.5 DSR-2018 1112 1.DT 2 pair Cable Mtrs 3500
3 Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.
3.1 DSR-2018 2.24.6 1.DU 2 Pair telephone cord outlet (RJ-11) Each 37
4 DSR-2018 1.27.1 1.DV Supply and fixing 1 or 2 module ( 75mm X 75mm ) GI Box along with modular base and cover plate for modular switches in recess etc as required Each 37
5 MR 1.DW Supply and fixing of Computer terminal (RJ-45) outlet in existing box with modular plate Each 55
6 MR Supply, installation, testing and commissioning of following Category 6, IDC patch panel prepackaged with wiring block with legs with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs.
6.1 1.DX Supply and fixing of 24 Port Jeck Panel Each 4
7 DSR-2018 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
a 1.21.1 1.DY 20mm dia Metre 50
b 1.21.2 1.DZ 25mm dia Metre 3000
c 1.21.3 1.EA 32mm dia Metre 50
8 MR 1.EB Providing and fixing of UTP CAT 6 Computer LAN/Telephone Cable With Star Separator in existing conduits . RM 2000
MR Supplying, drawing, connecting & testing of HDMI cable for Projector in existing conduit.
a 1.EC HDMI Cable RM 450
10 MR 1.ED Supplying, drawing, connecting & testing of 6 Core Fibre optec Single mode cable from existing Server and connecting to Data racks complete as required. RM 300
11 MR Supply ,installation ,testing and commissioning of following 6 core LIU to termination the Fibre cable for Patch Panel complete as required.
a 1.EE 6 core LIU Nos. 2
12 MR Supply and installation of following 19 inch width rack for ethernet switches with A.C. distribution box, wire manager, fan tray, lockable front tinted glass door and two pair angle to support the switch installed in the rack.
a 1.EF 12 U Rack Nos. 1
13 MR 1.EG Supplying, installation, testing & commissioning of 100W Amplifier with USB, MP3 player, Microphone (including 6 zone button station) with cabnet all necessary accessaries complete as required for Public address system Nos 1
14 MR 1.EH Wall mounted speaker with three tap changers in acoustically treated box with speaker and line matching transformer (2W max). Nos 26
15 MR 1.EJ Supply and laying 32/0.2mm twisted pair cu. wire for speakers RM 850
Note.High Side Equipments EPABX,PATCH Panels, Server, Switches and High End Cabling till Server/MDF are not included as the part of this tender
Total of Subhead-VI Carried to Summary
7 SUB-HEAD VII: EARTHING & UPS
1 DSR-2018 5.6 1.EK Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set 4
2 DSR-2018 5.4 1.EL Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set 12
3 MR 1.EM Supply and laying 40mmX6 MM GI strip at 5.0 meter below ground as strip earth electride including soldering etc as required Metre 100
4 MR 1.EN Supply and laying 40mmX6 MM CU. strip at 5.0 meter below ground as strip earth electride including soldering etc as required Metre 60
7 DSR-2018 5.15 1.EP Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Metre 50
8 DSR-2018 5.16 1.EQ Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Metre 50
GI Pipe Installation
a MR Supply and installation of following sizes of `A' class GI pipe for cable sleeves in recess/ on surface/Ground complete with all accessories pull boxes where ever required, G.I. fish wire, fixing hardware etc. including the chasing of wall/floor, and plastering the chased portion, digging the trench and back filling, making good the damages, sealing of pipe entry etc as required.
1.ER 200 mm dia RM 10
7.2 MR 20.0 UPS SYSTEM:
20.1 ONLINE UPS AS PER IEC 62040-3
A) Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following:
- Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added.
- IGBT Rectifier Modules to achieve less than 2% Input Current distortion and greater than 0.98 PF at Input at all loads.
- Fully microprocessor based with diagnostics capability.
- Dual Input (Separate Input for rectifier and separate input for Bypass)
Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per Annexure-1:-
a) 1.ES 1 No. 15 kVA online UPS (3Ph input & 3Ph output) for Server Set 1
B) 1.ET Design, manufacturing,testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with UPS capacity as mentioned, having back up at full load,with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system.(12V Cells) with 30 Minutes back up. Set 1
Note: Quoted price shall be inclusive of approved rating single core copper conductor cable connecting UPS and batteries.
Total of Subhead-VII Carried to Summary
8 MR SUB HEAD-VIII - DG SETS and BATTERY CHARGER
1.EU Supply, installation, testing and commissioning of 200 KVA, at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories as per specification and layout, drawing with battery charger, battery and battery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for intdoor installation complete as required. Set 1
Supply, laying of following sizes of MS Piping for Exhaust including providing suitable bends, reducers & supporting arrangement at suitable intervals including insulation on entire length of exhaust pipe with 50mm thick Rockwool insulation & painting etc. as required.
a) 1.EV 125mm (NB) MS ERW pipe RM 45
1.EW Supply, installation, testing and commissioning of 2x65 AH capacity 24 volts DC hermetically sealed maintenance free batteries duly charged including battery charger unit with provisions of Boost Charging, and Float charging. Suitable for 240 V, including DC DB single phase AC 50 Hz as per specifications Set 1
Total of Subhead-VIII Carried to Summary
9 SUB-HEAD IX : EXTERNAL LIGHTING (Quantity Assumed)
1 MR Constructing brick chamber with cover for cable entry of following sizes inside dimension) with cement concrete above work in cement mortar 1:5 (1 cement : 5 coarse sand) including making necessary notch for lighting the cover necessary excavation 10cm thick foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside and outside plastering with cement mortar 1:3 (1 cement and 50% coarse sand) with floating coat of neat cement finish complete as per requirement.
a) 1.EX 600 mm X600 mm X 750mm Deep Man hole Each 2
2 MR Erection of mettalic pole of following lengths in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregated 40mm nominal size) foundation included excavation & filling etc complete as required
1.EY Above 4.5 Mtr and Upto 6.5 Mtr Nos. 15
4 MR 1.EZ Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with with 1500mm single arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting with MCB & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete job as required. (but without pole collar). Nos. 15
6 MR 1.FA Supplying and fixing 70W LED type street light with die cas aluminium housing fir ingress protection of IP 65 and complete with all accesories etc on pole / buildingconnection with FR PVC insulated copper conductor and earthing the body as reqd. Each 15
a) MR 1.FB 4 core, 6.0 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor RM 400
b) MR 1.FC 4 core, 10 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor RM 50
8 DSR-2018 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) 7.1.1 1.FD Upto 35 sq. mm RM 400
10 DSR-2018 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) 7.5.1 1.FE Upto 35 sq. mm RM 50
11 DSR-2018 9.1 Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.
b) DSR-2018 9.1.1 1.FF 4C x 6 sq mm Set 30
c) DSR-2018 9.1.32 1.FG 4C x 10 sq mm Set 4
DSR-2018 5.18 1.FH Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. RM 100
MR 1.FJ Supplying and fixing 50mm dia GI pipe on the pole for cable entry to junction box as required. RM 60
DSR-2018 1.14.1 1.FK Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required Metre 150
DSR-2018 1.14.3 1.FL Wiring with 2 x 4.0 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4.0 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required Metre 50
DSR-2018 14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
14.14.2 1.FM 150 mm dia Metre 75
Total of Subhead-IX Carried to Summary
10 SUB-HEAD X: SOLAR SYSTEM :
1 SOLAR MODULES
MR 1.FN Supply , Installation, Testing & Commissioning of Poly Crystalline 320Wp Modules, IEC 61215/IS14286,IEC-61730 Part-1st for construction and Part-2nd for testing/safety IEC-61701/IS 61701,ISO 9001/ISO 14001,With inbuild bypass diode,Frame should be Al anodize,power tolerance of +/-3%,Vmp and Imp shall not vary more than 2%, With junction box arrangement having inbuilt bypass diode,weather proof,IP-65,with RFID tag. Nos. 15.00
2 GRID INVERTER
MR 1.FP Supply , Installation, Testing & Commissioning of 5 KWp Inverter , House MPPT,DG set interactive,output should compatible with grid frequency.IGBT/MOSFET,Microprodessor,DSP,430V,3-Phase,50Hz +/-3%,Ambient tem -20 dec to +50Deg,Humidity 95%, Protection IP-65 outdoor,grid voltage tolerance -20% to +15%, No load losses lees then 1% of rated power,efficiency 93% or above, THD less then 3%,P.F more then 0.9,fully automatic,having internal protections against any fault in feedr,Built-in meter and data logger to monitor plant, inverter desing as per IEC/BIS standard for efficiency and enviornmental tests as per IEC 61683/IS 61683 and IEC 60068-2 (1,2,14,30).MPPT as per IEC 60068-2(1,2,14,30)/BIS.Junction box should be IP-65 for outdoor as per IEC 529.Inverter should be grid as well as DG integrated. Nos. 1.00
3 ELECTRCAL- AC/DC SIDE
3.1 MR 1.FQ AC SIDE : Supply installation and commissioning of 1.6mm CRCA sheet steel encloser complete with interconnection and distribution bus bar, AC distribution board for output of inverters with SPD consists of following equipments:- 1) Incoming 63 A, 4P MCCB 1 No. Nos. 1.00
3.2 MR 1.FR DC SIDE(AJB): Supply , Installation, Testing & Commissioning of Junction Box suitable for outdoor (IP-65), Structure mounted type construction with following items complete as reuired: 1) Incoming 4 Nos. 16A Fuse 2) Outgoing 4 Nos. 16A Link Nos. 1.00
3.3 MR 1.FS Supply installation and commissining of 1c x 4sqmm flexible copper, 1.5KV grade, TUV certified Solar cable of approved make. (DC Solar Cable from PV Module to AJB) RM 100.00
3.4 MR 1.FT Supply installation and commissining of 4 sqmm flexible copper wire ,TUV certified Solar wire of approved make. (DC power cable from AJB to Inverter) RM 50.00
3.5 MR 1.FU 4Cx10 sqmm Al. Arm, 1.5KV grade, Cable. (AC Power Cable) RM 50.00
3.6 MR 1.FV 6 Sq mm copper wire in PVC Flexible/Rigid pipe for earthing like isolator/Inverter. RM 50.00
3.7 MR 1.FW Supply and fixing of 25 mm dia DWC flexible PVC conduit pipe RM 60.00
3.8 DSR-2018 2701 1.FX Supply and fixing of 2mm thick covered type pregalvanized GI cable tray of 100x50x1.6 MM . RM 20.00
3.9 DSR-2018 9.1.32 1.FY Supply and fixing of Brass compression gland suitable for 4Cx10 Sq.mm, Al.Ar, XLPE Cable. No. 2.00
3.10 MR 1.FZ Supply and fixing of suitable Cu. Lugs of round type for 4Sq.mm Cu. Wire for earthing. No. 10.00
3.11 MR 1.GA Supply and fixing of suitable Cu. Lugs of round type for 10 Sq.mm Cu. Wire for earthing. No. 2.00
3.12 MR 1.GE Supply and fixing of MC4 connector Suitable for 320Wp Module(Pair) Pair 5.00
3.13 DSR-2018 5.2 1.GB Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Set 2.00
3.14 DSR-2018 5.9 1.GC Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) RM 100.00
3.15 1.GD Ground mount fixed type structure (Module mounting structure) with all required material for execution and all the civil work Lot 1.00
Name of Package: Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1
: Schedules : General guidelines for filling up the Attachments
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
1 Bidder may note that non-submission of Bid Form shall lead to outright rejection of their bid and no clarification shall be sought from them in this regard.
2 Fill up only green shaded cells in the relevent attachments.
3 Bid Form and Attachment-3, 4, 5, 5A, 6, 7, 8, 9, 10, 11 & 13 are enclosed here in this workbook.
4 Attachment-1 (Bid Security) : To be submitted as per proforma provided in the bidding document. Bid Security should remain valid for 250 days from the original date of Bid Opening of First Envelope.
5 Attachment-2 (Power of Attorney) : No specific format is provided by POWERGRID. Bidder may use their own format.
6 Integrity Pact : To be submitted in line with clause 6(j) of ITB, Volume-IA
7 Safety Pact : To be submitted in line with clause 6(t) of ITB, Volume-IA
8 Attachment: 12 (Declaration of Key Managerial Person and Power of Attorney holder) shall be submitted in the format provided separately in Volume-III of Bidding Documents. Bidders are required to sign and stamp the same and upload the scanned copy in line with provisions of bidding documents
8 Attachment: 14 (Format for Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, 2017), if applicable, shall be submitted on a non-judicial stamp paper of Rs. 100/- in the format provided separately in Volume-III of the bidding documents.
9 Attachement: 15 (Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable [to be submitted on the letter head of the issuer] in the format provided separately in Volume-III of the bidding documents. [NOT APPLICABLE]
9 Attachment: 16 (Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA). [ APPLICABLE]
10 Attachment: 17 (Declaration regarding events encountered pursuant to ITB Clause 2.1). [APPLICABLE]
11 Attachment: 18 (Certification by the Bidder per DoE Order in line with ITB Clause 1.2.1). [APPLICABLE]
11 Attachment: 19 Bid Security Declaration
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
General Instruction to the Bidders for filling up this workbook of Bid Form and Attachments (1 to 11)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not fill the cell by dragging the other cell value in down or adjacent cell.
(vii) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder. Do not leave this cell blank.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-1A (Summary of Taxes and Duties applicable on the Item(s)/Materia(s)/Equipment(s)) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -1A (Taxes & Duties)
● Click at the link to go back to Sch-1A.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -1A (Taxes & Duties)
● Click at the link to go back to Sch-1A.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -1A (Taxes & Duties)
● Click at the link to go back to Sch-1A.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-2A.
● Fill up names & Designation of the representatives of bidder.
● Fill up additional information as required.
Happy Bidding !
Before filling up the Bid Form, the Bidder is required to fill up the details as under :
1 Enter Details of Amendments:
Amendments to Bidding Documents issued:
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Bid Proposal Form 1st Envelope
Bid Proposal Form (First Envelope)
Bid Proposal Reference:
Bidder's Address:
Contracts & Material Department
Power Grid Corporation of India Ltd
Northern Region Transmission System-3
3rd Floor, 12, Rana Pratap Marg the receipt of which is hereby acknowledged, we the undersigned, offer to execute the Works under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 6.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope (containing EMD and Techno-commercial part) and Second Envelope - Price Part (to be opened subsequently)
Lucknow - 226001 (Uttar Pradesh)
Name of Contract: Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
1.0 Having examined the Bidding Documents, including Amendment Nos. dated 00/01/1900, the receipt of which is hereby acknowledged, we the undersigned, offer to execute the Works under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 6.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope (containing EMD and Techno-commercial part) and Second Envelope - Price Part (to be opened subsequently)
1.1 We, including any subcontractors or manufacturers for any part of the contract, do not have any conflict of interest in accordance with ITB clause 1.2.2 .
Our Bid, as said above have been submitted as per the followings: For Attachment-1, bidder has to fill the following data
EMD DETAIL FORM FALSE TRUE
2.0 Attachments to the Bid Form (First Envelope): Are you NSIC/MSME Registered: Yes No We are NSIC/MSME registered under Public Procurement Policy for MSEs order 2012. We have enclosed a copy of NSIC Certificate reference no. dated DD-MM-YYYY and the issued certificate is valid upto and inclusive of DD-MM-YYYY. It is to confirm that the equipment(s)/item(s)/material(s) quoted in our bid is in the list of items indicated in NSIC certificate enclosed. We have submitted Bid Guarantee in the form of Bank Guarantee (Bank Guarantee No.-, dated DD-MM-YYYY issued from ) for a sum of Rupees /-, Valid for a period of 250 days from the original date of Bid Opening as per NIT i.e. upto and inclusive of DD-MM-YYYY. Select only one Option (Yes/No)
In line with the requirement of the Bidding Documents, we enclose herewith the following Documents / Attachments: Select the Form of EMD : Bank Guarantee Bank Guarantee No. Select any one Option (Yes/No)
2.1 Attachment-1:We have submitted Bid Guarantee in the form of Bank Guarantee (Bank Guarantee No.-, dated DD-MM-YYYY issued from ) for a sum of Rupees /-, Valid for a period of 250 days from the original date of Bid Opening as per NIT i.e. upto and inclusive of DD-MM-YYYY. Bank Guarantee No. NSIC Certificate No.
Date of Issuance DD MM YYYY
Valid up to DD MM YYYY
Amount of EMD :
Name of Issuing Bank :
2.2 Attachment-2: Power of Attorney, duly notarized, indicating that the person(s) signing the bid has(ve) the authority to sign the bid and thus that the bid is binding upon the Bidder during full period of its validity, in accordance with ITB Clause 2
2.3 Attachment-3: The documentary evidence in terms of ITB Clause 6.3(c) for the qualification data has been furnished by us All the prices and the price components stated in our bid price are firm in accordance with provisions of the bidding documents. All the prices and other terms and conditions of this proposal are valid for a period of Six [06] calendar Months from the date of opening of the bid
2.4 Attachment-4: The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein
2.5 Attachment-5: Information regarding ex-employees of Owner in our firm.
2.6 Attachment-5A: (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
2.7 Attachment-6: Work Completion Schedule.
2.8 Attachment-7: Declaration Regarding Social Accountability
2.9 Attachment-8: Price Adjustment Data
2.10 Attachment-9 & 9-P: Integrity Pact
2.11 Attachment-10: Additional Information
2.12 Attachment-11: Declaration regarding Price Bid
2.13 Attachment-12: Declaration of Key Managerial Person and Power of Attorney holder
2.14 Attachment-13: (Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises)
2.15 Attachment-14 : Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, 2017 and MoP order December 2018, if applicable.
2.16 Attachment-15: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable.
2.17 Attachment-16:Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
2.18 Attachment-17:Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.
2.19 Attachment-18:Certification by the Bidder per DoE Order in line with ITB Clause 1.2.1
2.20 Attachment-19: Safety Pact
3.0 Second Envelope
In continuation of First Envelope of our Bid, we have submited the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, Accordingly, we the undersigned, offer to execute the Works under the above-named package in full conformity with the said Bidding Documents for the sum specified in our Second Envelope Bid, in accordance with the terms & conditions of the Bidding Documents or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. We hereby confirm that the total amout of our bid is in accordance with the prices quoted by us under different Heads, as detailed below:
i. Erection Charges excluding GST
4.0 Undertakings/Compliances
4.1 We are aware that, in line with Clause No. 17.1 (ITB), our Second Envelope (Price Bid) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope Bid
4.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Works and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced
4.6 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelop (Price Bid) include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Works, in and outside of India
4.7 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN in all the states where the project is located and the states from which we shall make our supply of goods.
4.8 100% of applicable Taxes and Duties i.e. GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.9 We further understand that notwithstanding 4.0 above, in case of award on us, you shall also bear and pay/reimburse to us, GST in respect of Supply of Services by us to you, by the Indian Laws.
5.0 Construction of Contract
5.1 We declare that we have studied clause GCC 12 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us the Contracts covering all goods and related services
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us: GCC Clause 8 & SCC Clause 13 (Taxes, duties and levies/Contract Price) GCC Clause 14 & SCC Clause 18 (Contract Performance Guarantee), GCC Clause 18 & SCC Clause 4 (Time the essence of Contract/Completion Schedule/Period), GCC Clause 26.5 (Patents & Royalties), GCC Clause 45 (Guarantee), GCC Clause 46 (Defect Liability Period), GCC Clause 64 & SCC Clause 15 (Payment on Account/Terms of payment), GCC Clause 66 & SCC Clause 14 (Contract Price adjustment / Price Variation/ adjustment), GCC Clause 69 (Arbitration & laws), GCC Clause 70 (Laws & jurisdiction of Contract)
7.0 We conform that we stand committed to comply with all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records
8.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the Completion of the Works within the time stated in the Bidding Documents
9.0 If our bid is accepted, we undertake to provide Performance Security in the form and amount, and within the time specified in the Bidding Documents
10.0 We agree to abide by this bid for a period of 180 (One Hundred Eighty) days from the date fixed for opening of First Envelope bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
11.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
12.0 We understand that you are not bound to accept the lowest or any bid you may receive.
13.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:
YES Name & Address of agent Amount & Currency Purpose of Commission or Gratuity TRUE
14.0 We hereby declare that only the persons or firms interested in this proposal as principal or principals are named herein and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if we are awarded the contract, that this proposal is made without any connection with any other person, firm or party like-wise submitting a proposal and that this proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For & On Behalf of
Date: DD MM YYYY Name:
Place: Designation:
Business Address: ……………………………………………………………………….
Name of Principal Officer:
Address of Principal Officer:
Note: (Written power of Attorney of Signatories of bid to commit the Bidder must be enclosed with the bid. Bidders may use their own proforma for furnishing the required information with the bid)
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-3
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[DOCUMENTS IN SUPPORT OF MEETING THE SPECIFIED QUALIFYING REQUIREMENT]
Bidder's Address:
Contracts & Materials (NR-III RHQ)
Power Grid Corporation of India Ltd.,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
We submit the required documents/information as per clause ITB 6.3(c) as below:
S No. Particulars For Individual Firm
1 Name of the Firm 01 01 2000
2 Head Office/ Registered Office Address 02 02 2001
3 Telephone 03 03 2002
5 Contact Person 05 05 2004
6 Place of Incorporation/ Registration 06 06 2005
7 Year of Incorporation/ Registration 07 07 2006
8 Nationality of 08 08 2007
Owner (i) 09 09 2008
Owner (ii) 10 10 2009
Owner (iii) 11 11 2010
[Necessary documents to eatablish legal status of the bidder should be uploaded with the bid] 12 12 2011
A1. Average Annual Turnover 13 2012
Sr. No. Financial Year Turnover* (in Rs. Cr) Documents submitted in support of Turnover 14 2013
Average of Best 3 #NUM! 21 2020
* Note- Annual total income as incorporated in the profit & loss account except non-recurring income, i.e., sale of fixed assets.
Sr. No. Financial Year Networth (in Rs. Lakh)
A3. Liquid Assets/evidence of access to or availability of credit facilities
Sr. No. Description in Rs. Cr Documents submitted in support of Liquid Assets/Access to or availability of credit facilities
1 Liquid Assets/Access to or availability of credit facilities
B. Work Experience Details as on originally scheduled date of Bid Opening i.e. on 27.04.2022 23
S. No. Description Work #1 Work #2 Work #3 24
a Name & details of the Work 25
b Ref. No. of Award Letter/Contract/WO 26
c Date of Award Letter/Contract/WO (in dd-mm-yyyy format) dd mm yyyy dd mm yyyy dd mm yyyy 27
d Name of the Client with Contact details 28
e Value of Work as per Award Letter/Contract/WO 29
f Value of Work as per Final Execution 30
g Scheduled Date of Completion as per the Contract (in dd-mm-yyyy format) dd mm yyyy dd mm yyyy dd mm yyyy 31
h Date of actual Completion (in dd-mm-yyyy format) dd mm yyyy dd mm yyyy dd mm yyyy
i Copy of Award Letter/Contract/WO enclosed: (YES/NO)
k Reference Details of Completion Certificate/Performance Certificate/Any Other document like Acceptance of Final Bill by client issued by the client
k1 Ref. No. of Completion/Performance Certificate
k2 Date of issue of Completion/Performance Certificate (in dd-mm-yyyy format) dd mm yyyy dd mm yyyy dd mm yyyy
k3 Name and Designation of person issuing Completion/Performance Certificate
k4 Name of Company/Client who have issued Completion/Performance Certificate
k5 Name of work as per Completion/Performance Certificate
k6 Date of actual Completion as per Completion/Performance Certificate (in dd-mm-yyyy format) dd mm yyyy dd mm yyyy dd mm yyyy
k7 Amount of final work as per Completion/Performance Certificate
k8 Copy of Completion/Performance Certificate attached/enclosed: (YES/NO)
k9 File name by which Completion/Performance Certificate is attached/uploaded YES
C. Status of Firm (Proprietary/ Partnership/ Pvt. Ltd. Company/Public Ltd. Company)
Status of Firm Document Submitted Yes
No Affidavit for Proprietorship
Partnership Deed
D Other Documents Certificate of Incorporation
i PAN Detail Copy of PAN Card Submitted (Y/N)
ii Copy of Partnership Deed/ affidavit for Proprietorship/ Company MoA and AoA or Certificate of Incorporation, as applicable submitted (Y/N)
Date: DD-MM-YYYY Name: 0 Pvt. Ltd. Company
Place: 0 Designation: 0 Public Ltd. Company
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-4
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ALTERNATIVE, DEVIATIONS AND EXCEPTIONS TO THE PROVISIONS]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
Irrespective of whatever has been stated to the contrary anywhere else in our offer, only following are the deviations and variations from and exception to the specifications and tender documents for the above mentioned subject work. These deviations and variations are exhaustive. Except for these deviations the entire work shall be performed as per your specifications and other tender documents. Further, we agree that additional conditions, if any, found in our offer other than those stated below, save that pertaining to any rebates offered shall not be given effect to
Sl. No. Ref. of page, Clause & Name of Documents Description of Deviation Cost of withdrawal (Rs.)
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Tender Enquiry No: 0 Attachment-4
[ALTERNATIVE, DEVIATIONS AND EXCEPTIONS TO THE PROVISIONS]
Sl. No. Ref. of page, Clause & Name of Documents Description of Deviation Cost of withdrawal (Rs.)
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Tender Enquiry No: 0 Schedule-4
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[Technical Deviations Schedule]
Bidder's Address:
The following are the Technical deviations and variations from and exceptions to the specifications and documents for the subject package. These deviations and variations are exhaustive. Except these deviations, the entire work shall be performed as per your specifications and document.
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations/Exceptions
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Tender Enquiry No: 0 Schedule-4
[Technical Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations/Exceptions
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Tender Enquiry No: 0 Schedule-4A
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Deviations on important/critical conditions along with their withdrawal price]
Bidder's Address:
The following are the deviations/variations/exceptions to the provisions of important conditions stipulated in Conditions of Contract, Vol-I. We undertake to execute the contract in line with the provisions of Bidding Documents in respect of above said clauses in case POWERGRID agree to pay- us the withdrawal price indicated below against each such deviations/ variations/ exceptions.
Sl. No. Vol./ Section Clause No./ Page No. Deviations/Variations/Exceptions Withdrawal Price (INR)
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Tender Enquiry No: 0 Schedule-4A
[ Deviations on important/critical conditions along with their withdrawal price]
Sl. No. Vol./ Section Clause No./ Page No. Deviations/Variations/Exceptions Withdrawal Price
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-5
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Information regarding Ex-employees of POWERGRID in our Firm]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
We hereby furnish the details of ex-employees of POWERGRID who had retired/resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us.
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID (DD-MM-YYYY) Date of joining and designation in our organisation
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-5A
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Items, Components, Raw Material, Services Proposed to be sourced from Micro and Small Enterprises]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises(MSEs) for the purposes of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/ sub-contracted Name of Micro and Small Enterprises
Name & Address Category (Micro or Small)
The above is a list of items we propose to procure from MSEs. However, based on the situations during the executions of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEWs carried out by us, as per the format provided at ANNEXURES-(ANNEX)-VOL-I of the bidding document, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-5A
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Items, Components, Raw Material, Services Proposed to be sourced from Micro and Small Enterprises]
Sl. No. Item Description Quantity proposed to be bought/ sub-contracted Name of Micro and Small Enterprises
Name & Address Category (Micro or Small)
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-6 Attachment-6
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Work Completion Schedule]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
The Schedule for completion of various activities shall be as under:
Sl. No. Name of Activity Period from Date of LOA Period from Date of LOA
Commencement Completion Completion
1 Date of Notification of award(NOA) shall be treated as zero date/Commencement date 01.06.2022 01.06.2022
2 Contract Agreement , signing and submission of CPG 01.06.2022 30.06.2022
a Site Handing over
b Site office establishment
c Labour licence, stuatory compliances lnsurance.
d Source approval of materials including all testing as per SFQP requirement to start the works
e Layout & Marking of the buildings,WTP,STP & Boundary wall
3 Main ITI Building 01.07.2022 25.05.2023
a Boring for Pile Foundations
b Bar Bending of Pile Foundations
c RCC of pile foundations
d Testing of Piles as per SFQP
e Casting of Piles cap & raft of building
f Ground Floor (All Civil Works)
g First Floor(All Civil Works)
h Second Floor(All Civil works)
i Terrace Civil Works
j Fixing of doors & windows in both floors
k Fixing of all sanitary fittings indoor & external
l Internal painting of the buildings
m External Painting of the buildings
n Plinth protection of the building
o Drains all along the building
p Internal Electrification of the building including all fittings
q External electrification of the building including all fittings etc complete
r Completion of Terrace floor treatment etc all complete in all aspects
4 Boundary wall 01.07.2022 25.05.2023
a Pile Foundations/ Foundations
b Testing of pile foundations as per SFQP if applicable
c Construction of boundary wall as per drawings
d Brickwork of the boundary wall
e Plastering of the boundary wall
f Fixing of Concertina/Barbed Wire including angles
g Painting of both side of Boundary Wall
h Finishing the boundary wall etc all complete
5 Water Treatment Plant 08.07.2022 05.10.2023
a Excavation of the foundation
b PCC of the foundations
c RCC of the foundations
d Necessary fittings of all fixtures & fittings
e Painting of the Water Treatment Plant
f Electrical Fiitings etc with all connections etc all complete
g Finishing of the Water Treatment Plant etc all complete in all aspects
6 Sewage Treatment Plant & Rain Water Harvesting 08.07.2022 05.10.2023
a Excavation of the foundation
b PCC of the foundations
c RCC of the foundations
d Necessary fittings of all fixtures & fittings
e Painting/ Misc Requirement of the Water Treatment Plant
f Electrical Fittings etc with all conections ets all complete
g Finishing of the Water Treatment Plant etc all complete in all aspects
7 External Roads & Development 08.07.2022 14.12.2023
a Excavation of the roads
b WBM of the roads
c PCC of the roads
d RCC of the roads
e Groove Cutting & joint filling as per specifications
f Final Finishing of the roads including berms & other requirement as per drawings
8 External Electrification 25.08.2023 14.12.2023
a Laying of cables as per approved drawings
b Fixing of lighting poles and fixtures as per layout drawing
c Testing & Commissioning of the system all complete
d Final Finishing & completion of the works in all aspects
9 Finishing Works 09.06.2023 30.09.2023
10 Final Handing Over 15.12.2023 31.01.2024
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-7
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Declaration regarding Social Accountability]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
We conform that we stand committed to comply all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment- 8
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
(Price Adjustment Data)
We hereby furnish the relevant details pertaining to the price adjustment provisions for your specifications and documents . The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
PV Price Component
I. Supply and Placement of Reinforcement Steel:
i) A- WPI-HSD Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Baic Metals Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) A- WPI-HSD Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Cement,Lime and Plaster Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in
C-WPI-Cutting ,Shaping and finishing Stone Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2016= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : G5 Printed Name :
Place : Gurgaon Designation :
Bidder's Address:
Bidder’s name & Address: To
Name : Contracts & Materials Department
Power Grid Corporation of India Limited
Address : #REF! Northern Region Transmission System-III
#REF! 3rd Floor, 12, Rana Pratap Marg,
Lucknow-226001 (Uttar Pradesh)
We hereby furnish the relevant details pertaining to the price adjustment provisions for items as specified in your specifications and documents for the Construction of Industrial Training Institute (ITI) at Gorakhpur under CSRThe necessary documentary evidence are enclosed :
Sl. No. Name of Materials/Labour Name of the published index Value of index (30 days prior to date of opening of bids)
1 Supply & Placement of Reinforcement Steel
A High Speed Diesel coefficient Wholesale Price Index Number for ‘High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour coefficient Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Ferrous Metals coefficient Wholesale Price Index Number for ‘Ferrous Metals’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
2 For Concreting
A High Speed Diesel, coefficient a = Wholesale Price Index Number for High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour, coefficient l = Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Cement & Lime, coefficient b = Wholesale Price Index Number for ‘Cement & Lime’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Structural Clay Products coefficient Wholesale Price Index Number for ‘Structural Clay Products’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
The Bidders are required to indicate the value of indices for various components as of 30 days prior to the date of bid opening. In case bid opening date is extended after submission of bids because of any reason, indices as of 30 days prior to actual date of bid opening shall be considered for placement of award and for payment towards price adjustment.
Date : DD-MM-YYYY Printed Name : 0
Place : 0 Designation : 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-9
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
Bidder’s name & Address:
Address : #REF! #REF!
Contracts & Materials Department
Power Grid Corporation of India Limited
Northern Region Transmission System-III
3rd Floor, 12, Rana Pratap Marg,
Lucknow-226001 (Uttar Pradesh)
Format of Integrity Pact is enclosed in Volume-III of the bidding document
Date : DD-MM-YYYY Printed Name : 0
Place : 0 Designation : 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment- 10
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
(Additional Information)
Bidder's Name & Address:
Address : #REF! #REF! #REF! #REF!
Contracts & Materials Department
Power Grid Corporation of India Limited
Northern Region Transmission System-III
3rd Floor, 12, Rana Pratap Marg,
Lucknow-226001 (Uttar Pradesh)
We have enclosed with our proposal the following additional information for the subject package:
1.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 6.3 (k)]
1.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years. A consistent history of awards invlolving litigation against the Bidder or any patner of JV may result in rejection of Bid. [(Refer ITB Clause 6.3 (k)]
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
2 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government department or any other Company, in any country.
Year Name of Client Details of Transgression of Integrity Pact by the bidder
3 Current Contract Commitments of works in progress
Bidders should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Date: DD-MM-YYYY Printed Name : 0
Place:. 0 Designation : 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 0 Attachment- 10
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
(Additional Information)
Bidder's Name & Address:
Contracts & Materials Department
Power Grid Corporation of India Limited
Northern Region Transmission System-III
3rd Floor, 12, Rana Pratap Marg,
Lucknow-226001 (Uttar Pradesh)
We have enclosed with our proposal the following additional information for the subject package:
S. No. Brief description of Information Ref. and Page No.
Note: The Bidder should accordingly upload the scanned copies of the relevant documents (Refer Clause 6.3 of ITB, Volume - IA of bidding documents).
Date: DD-MM-YYYY Printed Name : 0
Place:. 0 Designation : 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 Attachment-11
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
[ Declaration Regarding Price Bid]
Bidder's Address:
Contracts & Material Department, Northern Region-III
Power Grid Corporation of India Ltd
Northern Region-III Headquarters,
3rd Floor, 12, Rana Pratap Marg
Lucknow - 226001 (Uttar Pradesh)
Further, we hereby confirm that except as mentioned in the Attachment-2 (Alternative, Deviations and Exceptions to the Provisions) hereof and/or the Covering Letter, forming part of Envelope-II of our bid
(i) there are no discrepancies/inconsistencies and deviations/omissions/ reservations to the Bidding Documents, in the Envelope-III bid
We also confirm that in case any discrepancies/inconsistencies and deviations/ omissions/reservations, as referred to in para (i) and (ii) above, is observed in the Second Envelope, the same shall be deemed as withdrawn/rectified without any financial implication, whatsoever to POWERGRID. However, in case of any arithmetical errors, the same shall be governed as per the provisions of ITB Sub-clause 17
Date: DD-MM-YYYY Name: 0
Place: 0 Designation: 0
Specification No.: 5002002243/OTHERS/DOM/K00 - NR3 RHQ -1 ATTACHMENT-13
Construction of Industrial Training Institute (ITI) at Gorakhpur under CSR
(Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts & Materials Deptt
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 3rd Floor
12 Rana Pratap Marg
Lucknow-226001 (UP)
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro & Small Enterprises (MSEs) order 2012 including subsequent Amendment/notification/order (Indicate Yes/No) Yes (Documentary Evidence attached)
Note: Documentary Evidence is to be attached. Please refer remarks at the end of Attachment. No
3. (c ) If 3(b) is 'Yes', please mention whether you are (Proprietary MSE/Private Limited Company) owned by SC/ST Entrepreneurs
3. (d) Are you a MSE owned by Women in line with Public Procurement Policy for Micro & Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro & Small Enterprises (MSEs) Amendment order 2018 including subsequent Amendment/notification/order (Indicate Yes/No)
Note: Documentary Evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
6. GSTIN in the States/UT from where the Supply of Goods takes place
Name of States/UT GSTIN No.
GSTIN in the States/UT from where the Supply of Services takes place (States where the site under the subject package is situated)
Name of States/UT GSTIN No.
9. PF Registration No. of the Company
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Telephone No(s)
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
* The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC/ST.
b. In case of partnership MSE, the SC/ST partners shall be holding atleast 51% shares in the unit.
c. In case of Private Limited companies, atleast 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificates issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c ) above.
Date : DD-MM-YYYY Printed Name : 0
Place : 0 Designation : 0
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
CIVIL WORK.pdf
pdf • 0.23 MB
firefighting.pdf
pdf • 0.29 MB
PLUMBING.pdf
pdf • 0.45 MB
SCC ITI Gkp.pdf
pdf • 0.29 MB
Technical Specification - Civil General.pdf
pdf • 0.13 MB
TECHNICAL_SPECIFICATION_ELECTRICAL.pdf
pdf • 0.67 MB
TECHNICAL_SPECIFICATION_PLUMBING & FIREFIGHTING (2).pdf
pdf • 0.91 MB
01 - SITE PLAN.pdf
pdf • 0.31 MB
02 - GROUND FLOOR.pdf
pdf • 0.37 MB
03 - FIRST FLOOR.pdf
pdf • 0.48 MB
04 - SECOND FLOOR.pdf
pdf • 0.36 MB
05 - TERRACE FLOOR.pdf
pdf • 0.27 MB
06 - FRONT AND RARE ELEVATION.pdf
pdf • 0.27 MB
07 - LEFT AND RIGHT SIDE ELEVATION.pdf
pdf • 0.26 MB
08 - SECTION.pdf
pdf • 0.27 MB
01- ELECTRICAL MAIN SINGLE LINE PLAN.pdf
pdf • 0.53 MB
02- ELECTRICAL LAYOUT SITE PLAN.pdf
pdf • 0.36 MB
03- ELECTRICAL LAYOUT GROUND FLOOR PLAN.pdf
pdf • 0.51 MB
04- ELECTRICAL LAYOUT FIRST FLOOR PLAN.pdf
pdf • 0.59 MB
05- ELECTRICAL LAYOUT SECOND FLOOR PLAN.pdf
pdf • 0.51 MB
06- ELECTRICAL LAYOUT TERRACE PLAN.pdf
pdf • 0.31 MB
01- GROUND FLOOR.pdf
pdf • 0.45 MB
02- FIRST FLOOR.pdf
pdf • 0.54 MB
03- SECOND FLOOR.pdf
pdf • 0.40 MB
Standard Field Quality Plan Civil Works for Site Packages Revision 04.pdf
pdf • 2.22 MB
Standard Field Quality Plan for Pile foundation Revision 07.pdf
pdf • 1.65 MB
11A-GCC CIVIL WORKS Vol-I (1).pdf
pdf • 0.58 MB
11B-GCC CIVIL WORKS Vol-I (2).pdf
pdf • 0.15 MB
11C -GCC CIVIL WORKS Vol-I (1).pdf
pdf • 0.17 MB
11D -GCC CIVIL WORKS Vol-I (3).pdf
pdf • 0.09 MB
Forms and Proceedures.doc
doc • 0.23 MB
~$A Covering Letter.doc
doc • 0.00 MB
~$A Instructions to Bidders.doc
doc • 0.00 MB
~$A_ANNEXURE-I (ITB)_EMD.doc
doc • 0.00 MB
~$B_Annexure-III (ITB)_QR.doc
doc • 0.00 MB
~$C_Annexure-II (ITB)_QR.doc
doc • 0.00 MB
~$D_Annexure-III(ITB)-e-RA.docx
docx • 0.00 MB
~$F-Annexure-IV (ITB) E-RA-Business Rules.docx
docx • 0.00 MB
~$Invitation to Bids(INV).docx
docx • 0.00 MB
~WRL0001.tmp
tmp • 0.08 MB
~WRL0005.tmp
tmp • 0.16 MB
02A Instructions to Bidders.doc
doc • 0.31 MB
02B_ANNEXURE-I (ITB)_EMD.doc
doc • 0.08 MB
02C_Annexure-II (ITB)_QR.doc
doc • 0.06 MB
02D_Annexure-III(ITB)-e-RA.docx
docx • 0.02 MB
02F-Annexure-IV (ITB) E-RA-Business Rules.docx
docx • 0.03 MB
1_Invitation to Bids(INV).docx
docx • 0.04 MB
~$ Special Conditions of Contract.doc
doc • 0.00 MB
~WRL2639.tmp
tmp • 0.11 MB
03 Special Conditions of Contract.doc
doc • 0.15 MB
03A_ANNEXURE-I (SCC)_CPG.doc
doc • 0.07 MB
03B_ANNEXURE-II (SCC)_Procurement from MSE.doc
doc • 0.09 MB
(Mandatory) Attachment 19 - Safety Pact.docx
docx • 0.03 MB
~$First Envelope & Bid Forms.xlsx
xlsx • 0.00 MB
~$tachment 14- Affidavit for self-certification.DOCX
docx • 0.00 MB
~$tachment-19- Bid+securing+Declaration.docx
docx • 0.00 MB
Attachment 12.doc
doc • 0.04 MB
Attachment -17-Declaration by the Bidder regarding events encountered (APPLICABLE).docx
docx • 0.03 MB
attachment 18- certificate by bidder.docx
docx • 0.02 MB
Attachment 9P- Integrity Pact.pdf
pdf • 0.20 MB
Attachment-16-E-RA.docx
docx • 0.02 MB
BOM CIVIL.xlsx
xlsx • 0.08 MB
BOM ELECTRIAL.xlsx
xlsx • 0.06 MB
Check List before Uploading bids.docx
docx • 0.02 MB
First Envelope and Bid Forms.xlsx
xlsx • 0.31 MB
Letter-Extention.docx
docx • 0.01 MB
Letter-Extention.docx
docx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .