Loading…
Loading…
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
12 Oct 2026, 6:00 pm4d left
Sh Hans Ram Meena, IDSE
GE Kapurthala
Repair/replacement and maintenance of LT overhead line, under ground cables, allied works at Mil Stn Beas and jandiala Guru under GE Kapurthala.
2026_MES_790661_1
8214/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Kapurthala
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Kapurthala
₹84,000
Yes
23 Sept 2026
23 Sept 2026
14 Oct 2026
23 Sept 2026
12 Oct 2026
6 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface all as directed | 4 | Each | 10 | ₹40 |
| 2 | Supplying, fabricating & erecting LT panel outdoor type CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply factory made fully compart mentalized made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of abgle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioning with including the following :-
(a) Aluminium bus bar of capacity 400 Amps for Three phase and Neutral. -04 No's
(b) Combined Voltmeter 415V, Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three), Indicator lamp
Incoming:- MCCB 4P 250 Amps, 36 KA 415 Volts (adjustable Thermal and fixed magnet r- 01 No
Outgoing:- (i) MCCB FP 125 Amps 16 KA 415 Volts (adjustable thermal and magnatic type70% to 100%)- 02 N
(ii) MCB TPN, 63 Amps, 16 KA 415 Volts.- 02 No's
(iii) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current rating 32 Amp | 2 | Each | 10 | ₹20 |
| 3 | Supplying, fabricating & erecting LT panel outdoor type CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply factory made fully compart mentalized made out of 3.14 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of abgle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioning with including the following :-
(a) Aluminium bus bar of capacity 250 Amps for three phase and Neutral.-04 No's
(b) Combined Voltmeter & Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
Incoming:- MCCB TPN 160 Amps, 36 KA 415 Volts(adjustable thermal and fixed magnetic) - 01 No's
Outgoing:- (i) MCCB 4 pole 100 Amps 16 KA 415 Volts - 02 No'
(ii) MCCB 4 pole 63 Amps 16 KA, 415 Volts - 01 No's (iii) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current rating 32 Amp | 2 | Each | 10 | ₹20 |
| 4 | M&L for preparation to steel surface of existing LT panels, LT feeder pillars boxes of any size and description internally and externally after scraping and scratching the old paint with emery paper etc, and painting with two coat of gray painting with spray gun and writing feeder names and numbers with suitable capital letters in English with white paint on and a black paint strip of size 20 cm x 25 cm all as directed. | 15 | Each | 10 | ₹150 |
| 5 | M&L in repair to LT panels feeder pillar box by dismantling old rusted and perished doors shutter and bus bar covers etc and providing new doors shutters, bus bar cover etc by cutting, welding, fabricating and made to existing shape with 3.15 mm plain black sheet and angle iron of required size including providing hinges and locking arrangement all as directed including material and labour for two coat of painting with synthetic enameled grey paint over a coat of red oxide primer. | 15 | Each | 10 | ₹150 |
| 6 | S&F in repair on load change over switch 4 pole 200 Amps in sheet metal enclosure acomplete all as specified and directed. | 1 | Each | 10 | ₹10 |
| 7 | S&F of aluminum thimbles/Lugs crimping type of size 16 to 25 Sq mm complete all as specified and directed. | 140 | Each | 10 | ₹1,400 |
| 8 | S&F of aluminum thimbles/Lugs crimping type of size 50 to 120 Sq mm complete all as specified and directed. | 120 | Each | 10 | ₹1,200 |
| 9 | S&F of aluminum thimbles crimping type of size 150 Sq mm to 240 Sq mm complete all as specified and directed. | 100 | Each | 100 | ₹10,000 |
| 10 | Dismantling & taking down existing ACSR conductor of any size by opening the binding wire from HT/LT electric poles complete all as specified. Note ACSR conductors wil be replaced with LT UG cable item no 27 to 35 where applicable or as directed. | 1.5 | Qtl | 100 | ₹150 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender.pdf
Tender Documents • 1.56 MB
BOQ_886414.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .