Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.3 L+₹1.3 L (4.92%)Rejected-AOC DOOR NO 62 1 PULIDHEVAN STREET MARUTHUPANDIYAN NAGAR NARIMEDU MADURAI DISTRICT 625 002 | MADURAI | TAMIL NADU | 625002 | L2 | Rejected-AOC L2 |
Tender Value
₹27.1 L
EMD Value
₹27,114
Closing Date
24 Nov 2023, 3:00 pmClosed
Commissioner Madurai Corporation
Aringar anna maligai
New Additional Construction of 2 Nos Class Room Building for First Floor and Paver Block Arrangements at Avaniyapuram Corporation Middle School Campus Inside in ward 92
2023_MAWS_386554_1
E1/SFC-SIG(O-M) /13203/PACK 2 / 22-23
Open Tender
Civil Works
Lump-sum
60 days
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹27,114
12 Dec 2023
7 Nov 2023
24 Nov 2023
7 Nov 2023
24 Nov 2023
7 Nov 2023
Amount
Dismantling the Existing Reinforcement Cement Concretr and Clearing away from the Site etc., complete
Dismantling the Existing Roof Press Tiles and Clearing away from the Site etc., complete
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Centering For Rectangular or Square Column
Centering For Plinth beam and Lintel Beam
Centering For Bottom only
Providing and laying in position Standardized Concrete Mix M-20 Grade in accordance with IS 456-2000 using 20mm and downgraded hard broken granite stone jelly for all RCC of works with minimum cement concrete 0f 325 kg/m3 and maximum water cement ratio of 0.55 including admixture ( Plaster / super plasticizer ) in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete improve workability without imagining strength and durability with about (5.0cu.m) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cum) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering and also including laying vibrating with mechanical vibrators finishing curing etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra, etc,. Complete complying with standard specification and as directed by the departmental officers the coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). For First Floor
For Second Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Brick work in CM 1:5 (one cement & five sand) using fly ash bricks of size 230 x 110 x 70" including finishing, curing, etc., complete complying with standard specification - 100CFT For First Floor
For Second Floor
Plastering with cement mortar 1:3, 10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Supply and Delivery Fabrication of MS Doors with outer frame and shutter frame in MS angle of size 40mm x 40mm x 6 mm with MS flat 25mm x 25mm x 6mm and MS sheet of 18 gauge including ventilating arrangements using 20mm square MS rods with locking arrangements including two coats of approved enamel paint over coat of red oxide including cost of angles, plates, sheets, fabrication charges, cost of hold fast and transportation charges etc., complete. Fully panelled Single leaf - Door
Fully panelled Double leaf - Window (without Ventilator)
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated Single Core unsheathed Copper Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with Module GI switch box in flush with wall with 6A one way module switch front plate continuous earth connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC light / Fan Point (For electronic regulator) (6 Points Per Coil) SD -314
Supply and fixing of single box type (philips / Havells / Eq) suitable for 4 feet 20W LED tube light with TW round blocks on wall or ceiling with 20W LED tube light with PVC unsheathed Copper leads from terminals to the fitting
Supply and fixing of 1200mm (48") sweep AC ceiling fan (Crompton / Havells / Usha / Equivalent) with 2 module 100W regulator complete with 300mm down rod on existing clamp SD 111
Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (lik standard make) SD. 179
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Painting with Ready Mixed Enamel Paint over the new Iron works of approved quality and colour with priming coat including the cost all materials etc., complete, in all floors.
Preparing the Existing surface to laying the road to Proper Gradient and remove the loose soil without damage the Water Supply Pipes. The Rate inclusive of all charges such as Earth work and remove the same 2Km away from the site etc, complete as per standard specifications.
Supplying and laying Rubberised interlocking Paver block M40 grade 80mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, stone dust cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
ADD GST 18%
V GANESAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .