Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-Finance PLOT NO 783 JAIL ROAD JHARPADA BHUBANESWAR | BHUBANESWAR | KHURDHA | ODISHA | ₹9.6 L | L1 | Accepted-Finance Qualified |
| 2 | L2₹12.0 L+₹2.4 L (25.0%)Accepted-Finance | ₹12.0 L+₹2.4 L (25.0%) | L2 | Accepted-Finance Qualified |
| 3 | L2₹12.0 L+₹2.4 L (25.0%)Accepted-Finance | ₹12.0 L+₹2.4 L (25.0%) | L2 | Accepted-Finance Qualified |
| 4 | L2₹12.0 L+₹2.4 L (25.0%)Accepted-Finance | ₹12.0 L+₹2.4 L (25.0%) | L2 | Accepted-Finance Qualified |
| 5 | L2₹12.0 L+₹2.4 L (25.0%)Accepted-Finance | ₹12.0 L+₹2.4 L (25.0%) | L2 | Accepted-Finance Qualified |
Tender Value
₹12.0 L
EMD Value
₹12,000
Closing Date
13 Apr 2026, 5:00 pmClosed
SUPERINTENDING ENGINEER RAYAGADA R AND B DIVISION
SUPERINTENDING ENGINEER RAYAGADA R AND B DIVISION-I
S/R for emergency maintenance (EI works) to various Non-residential buildings under Works Dept.
2026_EICCL_127504_18
RC(RANDB)RGD24/2025-26
Open Tender
Electrical Works
Percentage
180 days
RAYAGADA R AND B DIVISION I
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹12,000
Yes
18 Jun 2026
30 Mar 2026
15 Apr 2026
30 Mar 2026
13 Apr 2026
30 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. GROUP-A | |||||
| 2GROUP-B | |||||
| 3GROUP-C | |||||
| 4Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit). | |||||
| 5Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) . | |||||
| 6Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power) | |||||
| 7Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit) | |||||
| 8Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit). | |||||
| 9Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) | |||||
| 10Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) | |||||
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
finance_585963.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.13 MB
DTCN_Works_Non_res.pdf
Tender Documents • 0.78 MB
BOQ_585963.xls
BOQ • 1.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .