Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.9 L+₹3.6 L (11.6%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹36.4 L+₹5.1 L (16.3%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹38.6 L+₹7.4 L (23.5%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹48.5 L+₹17.2 L (54.9%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jun 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIRS RENEWAL OF LT PANEL BOARD, LT FEEDER PILLAR BOX, EARTHINGS, LT UG CABLE AND ALLIED WORKS AT MUDFORT AREA, SAPPERS LINE, HAVLOCK LINE, NCC COMPLEX AND CERTAIN OTHER AREA UNDER AGE EM.II OF GE UTILITY SECUNDERABAD
2020_MES_349290_1
GE(U)/SEC/TOKEN/13 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹70,000
Yes
23 Jul 2020
2 Jun 2020
1 Jul 2020
2 Jun 2020
29 Jun 2020
17 Jun 2020
Amount
(a) MCCB 4 Pole 400-400 Amps 36KA -01 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM94106OOS1OG (incommer) (b) MCCB 4 Pole 200-250 Amps 25KA -03 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOPO (Outgoing) (c) MCCB 4 Pole 160 Amps 25KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOMO. (Outgoing) (d) MCCB 4 Pole 100 Amps 18KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90677OOLO. (Outgoing) (e) MCB TPN 32 Amps 10 KA "C" Curve - 02Nos (f) MCB SPN 32 Amps 10 KA "C" Curve - 2 Nos (g) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (h) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
(a) MCCB 4 Pole 400 Amps 36KA -01 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM92109OOP1OG (incommer) (b) MCCB 4 Pole 200-250 Amps 25KA -01 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOPO (Outgoing) (c) MCCB 4 Pole 160 Amps 25KA -02 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOMO (Outgoing) (d) MCCB 4 Pole 100 Amps 18KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90677OOLO. (Outgoing) (e) MCB TPN 32 Amps 10 KA "C" Curve - 02Nos (f) MCB SPN 32 Amps 10 KA "C" Curve - 2 Nos (g) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (h) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
(a) MCCB 4 Pole 160 Amps 25KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOMO (Outgoing) (b) MCCB 4 Pole 125 Amps 25KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOMO (Outgoing) (c) MCCB 4 Pole 100 Amps 18KA -01 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90677OOLO. (Outgoing) (d) MCCB 4 Pole 63 Amps 18KA -01 Nos. Make :- L&T Cat No. CM90518OOJO (Outgoing) (e) MCB TPN 32 Amps 10 KA "C" Curve - 02Nos (f) MCB SPN 32 Amps 10 KA "C" Curve - 2 Nos (g) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (h) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
(a) MCCB 4 Pole 200-250 Amps 25KA -1 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOPO (Incommer) (b) MCCB 4 Pole 100 Amps 18KA -05 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90677OOLO. (Outgoing) (c) MCCB 4 Pole 63 Amps 18KA -01 Nos. Make :- L&T Cat No. CM90518OOJO (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set
(a) MCCB 4 Pole 200-250 Amps 25KA -1 No. adjustable type with thermal magnetic relesase Make:- L&T, Cat No. CM90642OOPO (Incommer) (b) MCCB 4 Pole 100 Amps 18KA -04 Nos with thermal magnetic relesase Make:- L&T, Cat No. CM90677OOLO. (Outgoing) (c) MCCB 4 Pole 63 Amps 18KA -01 Nos. Make :- L&T Cat No. CM90518OOJO (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (f) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Notes for Sl no 1 to 5 : Note:- (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces
(c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's: L&T or equivalent in Havells, Standard etc. (d) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (e) All MCCB to be connected with both side Spreader Link. (f) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board. (g) Provn of cable tray to be provided both side of the panel board for connection of Outgoing cable.Outgoing cable should not be connected to MCCB direcrly . (h) All serviceable MCCB in existing panel board are the property of the department and to be aken on changrge and used for day to day maintanance by the deptt. (i) Base of the panel should not be less than 600 cmm above the ground level. Necessar PCC for base /foundation required deemed to be included in the quoted rate. (j) The rate shall deemed to be include in the item rate.
Supply , lay, Test and commisioning of XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm laid in trenches/fixed to walls/poles etc including taking out existing cable all as directed. Make : Havells/Finolex Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no:06 above but 4 Core 16 Sqmm
All as per item no:06 above but 3.5 Core 25 Sqmm
All as per item no:06 above but 3.5 Core 35 Sqmm
All as per item no:06 above but 3.5 Core 50 Sqmm
All as per item no:06 above but 3.5 Core 70 Sqmm
All as per item no:06 above but 3.5 Core 95 Sqmm
All as per item no:06 above but 3.5 Core 120 Sqmm
All as per item no:06 above but 3.5 Core 150 Sqmm
All as per item no:06 above but 3.5 Core 185 Sqmm
Taking out and Relaying of LT cable of size10 sq mm to 50 Sqmm 2/3.5/4 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Notes: (a) Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item)
Taking out and Relaying of LT cable of size70 sq mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Notes: (a) Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item)
Relaying of serviceable bricks / pcc cover of any size retrived during taking out of cable complete all as directed
Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge.
All as per item no:19 above but 80 mm bore
All as per item no:19 above but 50 mm bore
All as per item no:19 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 95 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 150 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each depositing the same for cleaning the site all as directed by the Engr-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ of size 230 X 113 X 75mm laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down etc complete all as specified and directed. Note :- Sand cushion after punning down thickness 18 cm shall be measured for payment purpose.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
S&F PVC separators for suitable for LT over head line of 5 conductors and all as specified and directed by EIC
Disconnection and removing of MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 400 Amps Capacity burnt out one from the existing position supply and fixing the same making conncetions including install and testing complete all as specified and directed. Make : L&T/Legrand/Havells.
All as per item no: 36 above but MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 315-350 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 250 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 200 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 4 pole 35 KA breaking capacity fixed type of 160 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 3pole 35 KA breaking capacity fixed type of 160 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 4pole 35 KA breaking capacity fixed type of 100 Amps Capacity
All as per item no:36 above but MCCB's 415 volts 3pole 25 KA breaking capacity fixed type of 100 Amps Capacity
M&L for cleaning thoroughly the street light poles/LT/HT distribution poles of any height and any description (Maximum 11 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coat of aluminium paint over existing coat of paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed by Engineer-in-Charge. Make:- ASIAN SHALIMAR / BERGER
All As per item No:44 but for Two pole structure
All As per item No: 44 but for Four pole structure
Labour for Tree/Grass cutting, Cleaning and levelling of the surroundings of the power house area including removal of wastage material to a distance not EXC 50 M complete all as directed
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL.
S&F MCCB box made of sheet of 2mm thick size 30X20X15 CM Powder coated Suitable for fixing at Pole including two set of clamps comprisinf with the following i) MCCB 63 Amps 16 KA TP WITH BOTH SIDE SPREADER LINK.
Supply and Replace Change over switch 200 amps side handel ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 400 amps side handle ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 630 amps side handle ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
Supply and Replace Spreader link suitable for MCCB up to 125 Amps after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 160 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 200/250 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 185 to 300 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 70 to 150 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 25 - 50 Sqmm 3.5 core complete all as specified and directed
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of size 07MX0.6mX.35M with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar
Cutting the existing road straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
M&L for Cement Concrete 1:3:6 TYPE C2 (40mm Graded Stone Aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork AND FOR FOUNDATION OF GI PIPE, BOLLARD LIGHT (as/if required), complete all as specified and as directed.
M&L for Cement Concrete 1:3:6 Type C1 (20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as required), complete all as specified and as directed.
Supply and fixing bracket/clamps made of MS flat strips, angle iron suitable size and shape duly fabricated to be fixed with GI bolts/nuts and washer for fixing of GI bracket, PVC conduit, pole junction box or flood lights all as directed and specified
All as per item No.63 above, but single phase load of 12 KW with Circuit wiring min 25 sq mm 3 nos contactor each of 20-25 amps incoming outgoing MCB (3 nos) rating 20-25 amps Make:-Model No. Swadeep-02EC12kW1P or equivalent make as approved. Note for item No 67&68 :- (i) The contractor shall be obtained 1year gurranty and 1 year warranty for the sensor and 1 year warranty for the other accessories from the manufacturer and submit to the deparment duly signed by all concerned.
Disconnection existing LT UG cable of any size from pole/Oh line and connect the same to federpiller box by usinf cable glands, lugs etc as required complete all as directed
Supply and replace contactor ML 3 with coil operating voltage 230 Volt complete all as directed
Supply and Fixing of Timer Analog Type Suitable for 24 hours operation of street light of 16 amps capacity (LEGRAND/AVV/CG)
Supply and fix MCB TPN 32 Amps 10 KA, C Curve complete all as directed
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc. and Serviceable Materials keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling Insulators from Poles of any description and any size including Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
Taking out and refixing of pole steel tubuler 8/9 m long comple all as specified and directed. Note : rate quoted by the contractor inclusive of Excavation, PCC,Transportation, Dismantling of PCC Etc
Supply and Fix Solar LED street light 90 watt ( Min output 2400 Lumen and active power 30 watt) complete all as specified and directed. Make Luker model Number LSTSOL 90 / equivalent from havells/Surya
Supply fixing connecting and testing LED Post top lantern of 35 watt capacity with diffuser and painted aluminium deflector including nut, bolts, washers, clamps etc complete all as specified and directed by Engr -in-charge. Make: surya Cat Part No SLEPT 40 W ETPP or CG MODEL NO LPTO 40 CDL equivalent from havells/wipro
Supply of Rubber mat ISI marked of size 1mX2mX20mm
Supply of Hand Glouves 11 KV ISI marked
Supply and spread graded stone aggregate 40 mm in structure yard of 2/4 poles complete all as directed by Engr-in-charge.
Supply and spread graded stone aggregate 20 mm in structure yard of 2/4 poles complete all as directed by Engr-in-charge.
Servicing of capacitor panel of size not less than 20 KVAR complete including testing all components including relay, capacitor, contactor, operating coil of contactor , mcb wiring etc complete all including making the panel serviveable complete all as directed. ( S&F of Spares to be measured and paid separately under relevent items)note : rate quoted by the contactor inclusive of complete engineering charges to check and identyfy the faulty components and reason of malfunctioning
Supply and Fixing of Phase indicating lamp(Set of three) LED Type for indicating of three phase RYB in color suitable for 230 volt supply.
Supply and Fixing of Powerfactor meter analog type complete all as specified and directed . Make : L&T Model No: 76135 /AE
Supply and Fixing of Frequency meter 47 to 52 Hz analog type complete all as specified and directed . Make : L&T Model No: 23311/AE
Supply and Fixing of Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 5 kVAR 440 Volt 50 Hz complete all as specified and directed. Make L&T part No: LTBCH305B2/EQUIVALENT OF HAVELLS/EPCOS
Supply and Fixing of Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 10 kVAR 440 Volt 50 Hz complete all as specified and directed. Make L&T part No: LTBCH310B2/EQUIVALENT OF HAVELLS/EPCOS
Supply and Fixing of Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 15 kVAR 440 Volt 50 Hz complete all as specified and directed. Make L&T part No: LTBCH315B2/EQUIVALENT OF HAVELLS/EPCOS
Supply and Fixing of Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 25 kVAR 440 Volt 50 Hz complete all as specified and directed. Make L&T part No: LTBCH325B2/EQUIVALENT OF HAVELLS/EPCOS
Supply and Fixing of Capacitor duty contactor suitable for 8kVAR,400 volt,3 phase,50 Hz, coil operating voltage 230 volt complete all as specified and directed. Make: L&T PART NO: ST41807/equivalent from havells/CG
Supply and Fixing of Capacitor duty contactor suitable for 12.5 kVAR,400 volt,3 phase,50 Hz, coil operating voltage 230 volt complete all as specified and directed. Make: L&T PART NO: ST41808/equivalent from havells/CG
Supply and Fixing of Capacitor duty contactor suitable for 15 kVAR,400 volt,3 phase,50 Hz, coil operating voltage 230 volt complete all as specified and directed. Make: L&T PART NO: ST41809/equivalent from havells/CG
Supply and Fixing of Capacitor duty contactor suitable for 25 kVAR,400 volt,3 phase,50 Hz, coil operating voltage 230 volt complete all as specified and directed. Make: L&T PART NO: ST41810/equivalent from havells/CG
Supply and Fixing of commissioning of Eight stage APFC relay including necessary addl/alt to internal wiring to the APFC Panel completye all as specified and directed. Model No : RPM 8 of MAKE: L&T/ Equivalent in other makes as specified.
Supply and Fixing of MCB TP 16 Amps 10kA "C" Curve in replacement complete all, as directed
Supply and Fixing of MCB TP 32 Amps 10kA "C" Curve in replacement complete all, as directed
Supply and Fixing of MCB TP 63 Amps 10kA "C" Curve in replacement complete all, as directed
Supply and fixing of PVC Junction box of size 300x200x100mm ,light weight pole mounting including MCB 4P 10Amps -1 No including necessary clamp MCB mounting and mounting of Box on pole with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. Make :- SINTEX/Polycon
Supply,test,install & commsissioning of Bus bar chambers(including 4 bus bars i.e R,Y,B and neutral),3-Ph with netral,1100volts,50Hz including suitable sheet metal enclosure along with necessary screws,nuts,bolts and other Misc accessroies and making connections(input &out put) with cable terminal ends complete for the following current carrying capacities (a)4-Way, 100 Amps Make: Havells/L&T/Standard
Supply , install testing and commissioning of fixed capacotir panel made out of 3.15 mm CRCA sheet outdoor type double door , both side openable with projected Globe roof for rain water protection, powder coated with necessaty foundation and base and comprising of the following: (a)Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 5 kVAR 440 Volt 50 Hz along with resistance complete all as specified and directed. Make L&T part No: LTBCH305B2/EQUIVALENT OF HAVELLS/EPCOS (b) MCB TP 16 Amps 10kA "C" Curve in replacement complete all, as directed (c) Necessary internal wiring as required with copper wire for proper functioning of the fixed capacitor bank. (d) Size of the capacitor panel should not be less than 0.6MX0.5M X0.3M. Size of the leg of the panel should not be less than 600 mm lon and made out of min 25mmX25mmX4mm angle iron. 200 mm below GL and 400 MM GL incl Necessary excavation and PCC for foundation. Cost deemed to be included in the quoted rate.
Supply , install testing and commissioning of fixed capacotir panel made out of 3.15 mm CRCA sheet outdoor type double door , both side openable with projected Globe roof for rain water protection, powder coated with necessaty foundation and base and comprising of the following: (a)Three phase power capacitor heavy duty BOX TYPE RESIN FILLED OF RATINGS 10 kVAR 440 Volt 50 Hz complete all as specified and directed. Make L&T part No: LTBCH310B2/EQUIVALENT OF HAVELLS/EPCOS (b) MCB TP 20 Amps 10kA "C" Curve in replacement complete all, as directed (c) Necessary internal wiring as required with copper wire for proper functioning of the fixed capacitor bank. (d) Size of the capacitor panel should not be less than 0.6MX0.5M X0.3M. Size of the leg of the panel should not be less than 600 mm lon and made out of min 25mmX25mmX4mm angle iron. 200 mm below GL and 400 MM GL incl Necessary excavation and PCC for foundation. Cost deemed to be included in the quoted rate.
Mavee Syndicate
STANDARD AGENCIES
m. surender singh
POWER CONSTRUCTION COMPANY
diesel power services (a.p)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .