Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.2 L+₹4.2 L (15.4%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹32.3 L+₹5.2 L (19.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹32.4 L+₹5.3 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹32.9 L+₹5.9 L (21.7%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
Refer Docs
EMD Value
₹49,000
Closing Date
28 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
PROVN OF 05 NOS FIRE POINT AT NEW FIRING POINT AT PXE RENOVATION OF CREW ROOM AT PXE HELIPAD SHIFTING OF ELECTRICAL NETWORK AND REAPPROPRIATION OF OLD DG ROOM AT TELEMETRY ITR PROVN OF WALL MOUNTED FANS AT ITR MAIN GATE REPAIR AND REPLACEMENT OF E AN
2024_MES_639748_1
8906/E8
Open Tender
Civil Works
Item Rate
180 days
Chandipur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹49,000
Yes
27 Mar 2024
30 Jan 2024
1 Mar 2024
30 Jan 2024
28 Feb 2024
19 Feb 2024
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (B/R PART)
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m for all kind of soil, as directed.
M & L for 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources as in foundation and filling mass concrete complete all as specified and as directed.
M&L for Cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in foundation and filling mass concrete complete all as specified and as directed.
M & L for Brick work with non modular fly ash brick confirming to IS : 12894, class designation 10 average compressive strength built in cement mortar (1:6) complete all as specified and as directed.
M&L for Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position complete all as specified and as directed.
M&l for Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position complete all as specified and as directed.
Supply and fixing of pre-painted hot-dip galvalume aluminum-zinc alloy metallic coated trapezoidal profile steel sheet 0.50 mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 4, coating class AZ150 of an approved colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as directed.
Supply and fixing of pre-painted hot-dip galvalume aluminum-zinc alloy metallic coated plain steel sheet 0.50 mm thick (Total Coated Thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 4, coating class AZ150 of an approved colour having tensile strength of 550 Mpa as in ridges/facia and similar work, fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as directed.
M & L for 40 mm thick P.C.C(1:2:4) type B-1 (using 20mm graded stone aggregate) as in floor or top layers above brick/concrete srface complete all as specified and directed.
M & L for rendering 20(12+8) mm thick on other than fair faces of brick work or concrete surfaces of walls in cement mortar (1:4) and top layer mixed with liquid WPC @ 0.25% by the weight of cement or as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and as directed. Note: WPC will be measured and paid separately as “Supply” only.
Supply only liquid water proofing compound (WPC) of best quality complete all as specified and as directed.
M & L for 2 coats painting with synthetic enamel paint of approved brand and manufacture to give an even shade over a coat of ready mixed red oxide zinc chromate primer of approved brand and manufacture on new steel galvanised iron/steel works complete all as specified and as directed.
M&L for finishing walls with Acrylic Smooth exterior paint of required shade in newly plastered surface of external wall and applying two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and as directed.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering from wall and ceiling and preparing the surface smooth including necessary repairs to scratches etc. complete
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade over old plastered surfaces (Two or more coats applied @ 1.43 ltr/ 10 sqm) incl exterior wall putty complete all as specified and as directed.
Dismantling doors, windows and clerestory windows ( wood) shutter of area 3 sq. metres and below each including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.
M&L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium work for frame of Door with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing /paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions. (Glazing, paneling and dash fasteners to be paid for separately)
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) shutters of door including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required.
M&L for Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum with decorative lamination on both sidesdoors, with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions.
SCHEDULE 'A' PART-II (E/M PART)
Taking down carefully of any type of point wiring light, fans, socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc for taking schedule of credit and making good disturbed surface of wall, floor etc complete all as directed and specified.
Taking down unserviceable sub-main wiring any type with rigid steel conduits/PVC Conduits/PVC casing-caping complete all as specified and directed.
M&L for point wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, included modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required for concealed wiring, including all necessary wall cutting and making good disturbed surface complete all as specified and directed.
M&L for indipendent 5A circuit wiring alongwith earth wire of 2 x 2.5sq. mm + 1 x 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required for concealed wiring, including all necessary wall cutting and making good disturbed surface complete all as specified and directed.
All as per Sl Item No. 2.04 above but for 5A same board socket 2 x 1.5sq. mm + 1 x 1.5 sq. mm earth wire.
M&L for power plug / industrial socket wiring with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in recessed concealed wiring including all necessary wall cutting and making good disturbed surface with medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing all as specified and directed.
All as per Sl Item No. 2.06 above but 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supply and fixing of LED surface/ceiling mounting 2 feet x 2 feet LED luminaire light fitting 30Watt, lumen efficacy 120 lumen / watt, complete all as specified and directed.
S & F new 20 W surface and wall mounted LED batten with aluminium housing and integrated driver, lumen efficacy 120 lumen / watt complete all as specified and directed.
S & F new 10 W wall mounted mirror LED batten with aluminium housing and integrated driver, lumen efficacy 120 lumen / watt complete all as specified and directed.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 5/6 A switch modular type on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
All as per Sl Item No. 2.13 above but for 5 pin 5/6 A socket outlet
Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
S&F Ceiling rose 5A, 3 terminal PVC/poly carbonate isolated body ON existing jucntion box including connectionsets as required
Taken down of existing ceiling fan of any sweep and keep in safe coustody for refix, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Rewinding to single phase 250 volt ceiling fan of any sweep / exhaust fan upto 450 mm with copper winding wire as per existing size and turne complete all as directed and specified.
S&F capacitor single ph 440V of capacity 4 mfd complete all as specified and as directed.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of 4 way recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required.
Supplying and fixing of 6 way recess mounting, vertical type, 230 V, Double door MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs.
All as per Sl Item No. 2.25 above above but for 8 way
All as per Sl Item No. 2.25 above but for 12 way
Supplying and fixing 5 A to 32 A SP MCB rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.
All as per Sl Item No. 2.28 above but for SPN MCB
Supplying and fixing 63A, MCB four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
All as per Sl Item No. 2.30 above but of 40A capacity
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
M & L for dismentling of split AC of capacity upto 2.0 TR by pump down the gas and removing from site and keep in safe coustody and refix the same in old or new possition by fixing of new outdoor stand with anchor bolt and complete servicing including gas filling complete all as specified and directed. Make-LG/Voltas/Carrier/Daikin
M & L for carefully dismentaling and shifting of existing AMF panel from site to new location with in the range of not more then 50 mtr by disconnecting of all existing cable, glands,luges etc including dismentaling of existing plinth base and make good to disturbed surface and placing to new location with all necessery connection including rectification of pannel by replacing of all main & aux contactor and relay to make workable etc complete all as directed and specified.
Excavating trenches for Pipes, cables etc. not exceeding including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :complete all as specified and directed.
Lifting of existing 1.1 kV LT UG cable of any size from the existing treanch at site safely for reuse complete all as specified and as directed
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand complete all as directed
M&L for Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
M&l for Cement plaster skirting 18 mm up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core
All as per Sl Item No. 2.42 above but cable of size 95 sq mm 3½ core..
All as per Sl Item No. 2.42 above but cable of size 50 sq mm 3½ core..
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5C X 240 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
All as per Sl Item No. 2.45 above but cable of size 95 sq mm 3½ core..
All as per Sl Item No. 2.45 above but cable of size 50 sq mm 3½ core..
Supplying, installing testing and commissioning CPRI approved compact type pre fabricated company made panel board as per approved make list as specified , made with 3.15 mm thick seven tank processed based on angle frame of 75x75x6 mm by using PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) for fixing of panel having insulated bus bar TPN aluminium of rating not less than the 1.5 times the rated capacity of the incomer MCCB, 3 phase 4 wire system with openable shutter and locking arrangement and spray painting with two coats of stove enamelled paint over a coat of red oxide primer internally and externally complete comprising with the following accessories:- INCOMING:- (a) On load Changeover TPN, 440V, 400 Amps - 01 No. (b) MCCB 4P, 440V, 250 Amp having rupturing capacity 25 KA - 01 No. OUTGOING:- (b) MCCB 4P, 440V, 125 Amp having rupturing capacity 35 KA - 02 No. (c) MCCB 4P, 440V, 40 Amp having rupturing capacity 25KA - 01 Nos (d) MCCB 4P, 440V, 32 Amp having rupturing capacity 25KA - 01 Nos (e) Pre wired meter module detachable type consist of fwg:- (i)Voltmeter 0 to 500 V - 01 No (ii) Ammeter 0 to 200 A with suitable CT (iii) Indication lamp - 02 Nos
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead wire of size 6 SWG or galvanized earth lead strip of size 25 mm x 5 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia of length 2.7 m, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with Masonary earth pit of size 300mm x300mm , mortar 1:6 with Common burnt clay F.P.S. (non modular) bricks class designation 7.5 and outer plaster with cement mortar 1:4 of 10cm thickness,CI/MS cover plate hinged to frame with Locking arrangement as pit cover including galvanised earth lead wire of size 6 SWG or galvanized earth lead strip of size 25 mm x 5 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as specified and all as directed.
Supplying and laying 6 SWG G.I. wire below/above ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.
Providing and fixing 25 mm x 5 mm G.1. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.1. nut, bolt, spring, washer excavation and refilling etc. as required.
Providing and fixing 25 mm x 5 mm G.1. strip on surface or in recess for connections etc. as required.
Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
All as per Sl Item No. 2.53 above but for 32 mm dia
Material and labour for GI water tubing "medium grade" complete for cable protection complete with pipe of size 80mm dia
Supply and fixing wall mounted swinging type air circulator fan 450 mm (min) sweep with double bearing, AC single phase 230 volts, including electrical connection with twisted three core PVC insulated flexible cord of size 0.75sqmm copper conductor from celing rose/plug socket complete all as specified and as directed.
Supply and installation, testing and comissioning of hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minium 3 star rating and EER 3.2 of capacity 2 TR complete with fixing bracket and its connected accessories complete all as specified and as directed. Make-Voltas/LG/Carrier/Daikin
Supply, install, testing and commissioning voltage stabilizer copper wound electronic including connection to air conditioner complete suitable for single phase input voltage working range 150-290 volts 50Hz AC with stable output of 230 volt supply with low voltage high voltage cut off & time delay arrangement of capacity 5.0 KVA input output voltmeter with suitable arrangement for fixing at wall at site complete all as specified and directed Make-Volina/Vguard/Sen Pandit
Supply and fixing timer switch system for schedule alternative operation of AC of suitable capacity with minimum 20 Amp Rating with contractor and metal encloser inside complete all as s specified and directed
Supply, installation and commissioning of SMF battery of capacity 12V, 150 AH for existing online UPS with minimum 30 min back up, 3 phase AC input 300 to 450 volts and output 415 Volts (+) or (-) 1% complete all connected with maintenance free battery bank & interconnector for batteries & Isolation switch for each bank of battery complete all as specified and directed. Make - Amaron/Aplab/AE/Volina or techno commercially equivalent Note:- (i) Batteries must guarantee a minimum back up time as desired. (ii) All necessary connection, wiring, minor repair to UPS and all connected accessories is included in the above quoted rate
Disconnecting and dismentling online UPS of capacity 60 KVA (02 Nos) after disconnection all the electircal connection from UPS and consist of following parts (i) Supply and replacement of microprosser driver card-01 Nos (ii) Supply and fix 12 volts sensing transformer card -01 Nos, including supply and replacement of microprosser driver card and removing all the cleaning and removing moisture from UPS and tesing of self diagnostic with on load testing and refixing the same in its positions at "New firing point PXE" complete all as spd and directed.
Fabrication, supplying, installation and commissioning of LED signage board of letter in English and Hindi of total size of 10ft x 2.5ft (size may be vary as per site requirement) with white acrylic and ACP sheets. LED of each letter shall be of 12V waterproof LEDs (preferably Samsung and Havells Cables). LED for each letter having 3 row equally spaced. Colour of emission will be blue Colour with white background. The letter structure to be installed on the top of the Office building shall withstand 200 km/hr wind velocity. The required logo letter in Hindi, English will be fixed on terrace of the buildings. All materials shall be as per the technical specifications of the tender and got approved before start of fabrication and installation. Note : The following items are included in the above quoted rate:- (i) The required Logo letter (dimension 3 ft. x 1.5ft.) placed above Hindi letters with reasonable spacing between the above two. (ii) Timer and Conductor of required capacity to be provided as technically required (iii) New Iron Structure of required dimensions (cost including placing pillars, fine quality, iron angles, square pipe frame along with welding and coluoring) (iv) Separate electrical connection shall be provided with cable to the sign board. (v) Metal Framing should be provided around each board. (vi) Contractor is advised to read all the terms and conditions & see the site conditions before quoting and understand the nature/scope of work, clear all doubts before quoting as the specifications mentioned in BOQ are indicative not exhaustive. (vii) All items of works mentioned above shall be carried out as per MES specifications, high standards.
Dismantling of the existing sign board letters and structure, removing it from the site and replacing of the same with new letter matching with exisitng sign board complete with all repair works as specified and as directed.
Supply install, testing and commissioning of 400W water proof power supply convertor with all necessary connectors for proper function of sign board all as specified and as directed
Supply and fixing of new LG LED connect 150PC to 165PC with all necessary accessories for proper function of sign board all as specified and as directed
KRISHNA ENTERPRISES
RPL SYNDICATE CO
ALLIANCE
RANA ENTERPRISES
jlenterprise
chauhan syndicate
M/S RAJENDRA PRASAD
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
ALLIANCE
RPL SYNDICATE CO
KRISHNA ENTERPRISES
chauhan syndicate
jlenterprise
M/S RAJENDRA PRASAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .