Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest L1 | |
| 2 | L2₹48.4 L+₹1.6 L (3.33%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹50.8 L+₹4.0 L (8.53%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹51.0 L+₹4.2 L (8.92%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended Contractor not upload certain docs alongwith DD in 1st Cover |
Tender Value
₹44.6 L
EMD Value
₹89,500
Closing Date
27 Mar 2024, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot
PROVN OF DG SET AND ASSOCIATED WORKS SERVICES FOR EAGLE PROJECT AND ADDN/ALTN TO CUPBOARD IN BLOCK-III OF OFFICER MESS AT AIR FORCE STATION PATHANKOT
2024_MES_644476_1
8422/GE/PAF-73/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹89,500
Yes
7 Jun 2024
28 Feb 2024
29 Mar 2024
28 Feb 2024
27 Mar 2024
13 Mar 2024
Amount
Supply, installation, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity 62.5 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF ( complete with control panel including integrated powder coated accoustic enclosure as per CPCB regulations and duly certified by agencies / labs designated by CPCB for noise , sound air pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE required capacity for driving 62.5 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :- (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filters & fuel pipelines including fuel flow meter (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed accoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 140 AH including interconnecting cables/ leads with terminals complete with starting/ stopping switch, volt meter etc - 01 Set. (B) ENGINE INSTRUMENT PANEL digital type indicating the following : (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (C) ALTERNATOR Shall be self excited, self regulated, brushless for 62.5 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ± 1% with class "H" insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete - 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. (E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (F) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 62.5 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (i) Master switch for auto/ manual/ reset/ off - 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CTs 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type, 96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure
Supply and fix MCCB 250 Amps Icu=36 KA at 415 Volts 4P with thermal magnetic release . It should be with adjustable load setting Ir=(0.8 to 1.0) x In, Tcs = 100 % Icu and with adjustable thermal release, complete all as specified and as directed by Engr-in-Charge.
Supply, install, test and commissioning in replacement of outdoor factory made powder coated cubical type double door , compartmentalised LT feeder pillar box of size 0.90x0.45x1.2m complete weather proof and verminproof conforming to IP-54 made out of 3.15mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 45 x45 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping. Markings should be made with vinyl sheet indicator to identify incoming and outgoing circuits. Feeder pillar box shall be comprising of following :- a) MCCB, 4 pole, 200 Amps, 25KA with adjustable thermal magnetic relaese - 1 No. ( incoming) b) MCCB 4 Pole 125 Amps, 25 KA with adjustable thermal magnetic release - 03No. ( out going) c) MCCB 3 Pole 100 Amps, 16 KA with adjustable thermal magnetic release - 02No. ( out going) d) MCCB 3 Pole 63 Amps, 16 KA with adjustable thermal magnetic relaese - 04 Nos.(out going) e) LED phase indicating lamp - 01 Set. f) Digital multifunctional meter showing Amp Voltage, PF Frequency , KVA, KWH etc Aluminium Bus bar 3 phase 4 wire of capacity 400Amps - 01 Set Note :- Rates for necessary for finding out the loops of connecting cables to old panel and for new panel foundation are deemed to be included in the quoted rates.
Supply and fixing on load change over switch 415 Volts in sheet metal enclosure 4 pole of capacity 125 Amps froont handle operated fixed on angle iron frame made out of 40mm x 40mm x 5mm angle and 1.2 Mtrs long above the ground complete all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 150 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 70 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge.
Supply and fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 50 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, etc or for shaft, wells, cesspits, manholes, pier holes, etc, n.exc 10 sqm on plan and n exc 1.50 in depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-Charge.
Returning filling in incl spreading levelling, watering and well ramming in layer not less than 25 cum each layer complete all as specified and as directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-Charge.
Material and labour for sand cushioning to underground cable with dry sand locally available 8cm thick before laying of the cable and 15cm thick after laying and stretching the cable below the bricks/PCC cover, punning of sand using suitable T&P as per site condition, complete all as specified and as directed by Engineer-in-Charge.
Material and labour Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and as directed by Engr-in-Charge.
Earthing complete with copper earth plate of size 600x600x3.15 mm thick electrode and 20 X 3 mm copper Strip as earth lead buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level, connected to 20 x 3 mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I connected to earth test terminal point all as specified or as indicated inclduing test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation, earth work, PCC pit, CI Cover, funnel with watering pipe, suitable size of light grade GI protection pipe for earth strip in ground form pit to plinth protection etc all as required at site for complete earthing.
Supply and fixing copper strip of size 20x3.15 mm fixed on wall saddle ,screw, for roof conductor and down conductorwith insulators all as specified and directed by Engr-in-charge.
Supply and fixing cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation all as specified and directed by Engr-in-charge.
Supply and fixing of GI tube light grade with all fittings laid in trenches and fixed on poles/walls of size 80mm dia all as specified and directed by Engr-in-charge.
Supply and fixing of GI tube light grade with all fittings laid in trenches and fixed on poles/walls of size 50mm dia all as specified and directed by Engr-in-charge.
Supply and fixing modular fire Extinguiser 10 Kg automatic clean agent gas roof/ ceiling mounted all as specified and directed by Engr-in-charge.
Supply and fixing Motorized centrifugal, electric driven barrel pump complete up to 1 WHP all as specified and directed by Engr-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers notexceeding 25 cm in soft/loose soil all as specified and directed by Engr-in-charge.
Material and labour for Surface dressing not exc15 cm deep in soft/loose soil all as specified and directed by Engr-in-charge.
Material and labour for Plain Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundations,filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 100 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base of flooring etc complete all as specified and directed by Engr-in-charge.
Material and labour for 50mm Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-charge.
Material and labour for Machine pressed precastconcrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed by Engr-in-charge.
Filleting in any position and to any shape in cement mortar 1:4 including all mitres, stops, etc n exc. 25 sq cm complete all as specified and directed by Engr-in-charge.
Supply and fixing of Rolled steel in Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410-W(Gde-E-250) complete all as specified and directed by Engr-in-charge.
Material and labour for Plates (plain or chequered) channels, square cut or notched of Fe410-W(GdeE-250) quality B (ordinary and counter sunk)forming holes, without any attachment complete all as specified and directed by Engr-in-charge.
Supply and fixing for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Material and labour for Painting two coats with synthetic enamel paint on new steel or iron surfaces of any description exceeding 10 cm width/girth including preparation of surfaces and over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. .
Taking down Chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge. .
Material and labour for Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination as in Shelf and partition walls and fixed with screws complete all as specified and directed by Engineer-in-Charge. .
Drapery curtain rod of metalic 25 mm dia covered with PVC coating complete with bracket and side caps fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
Supply and fixing for Stainless steel butt hinges medium weight 100mm all as complete all as specified and directed by Engineer-in-Charge. . Note:- All screw shall be self tapping chrome plated and length of screw not less than 38 mm
Supply and fixing for Granite (of any type and any size in shelves and partition) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engineer in Charge.
Supply and fixing for Solid PVC Wall Lining consisting of 5mm thick single side prelem PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed by Engineer-in-Charge. .
Supply and fixing for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed by Engineer-in-Charge. .
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
M/S SINGH AND ASSOCIATES
Surya & Gautam Builders
M/S G P MARWAHA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .