Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.8 L+₹1.0 L (2.93%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.9 L+₹3.2 L (9.12%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹39.0 L+₹4.3 L (12.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
7 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Laxmisha Suvarna
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
PROVN OF CERTAIN WORK SERVICES AT BLDG NO P-104 TO UPGRADE AFNET EQUIPMENT ROOM AT AFSSR AND PROVN OF ADDITIONAL E/M INFRASTRUCTURE FOR UG NODE AT AFSSR UNDER GE (AF) GURGAON
2024_MES_638172_2
CWE/GGN/GT-25/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Af Stn Gurgaon
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Gurgaon
₹76,400
Yes
1 Apr 2024
14 Feb 2024
11 Mar 2024
14 Feb 2024
7 Mar 2024
22 Feb 2024
14 Feb 2024 - 21 Feb 2024
Amount
Supply, installing, testing and commissioning disrtibution transformer step down of outdoor type,energy efficent level -II confirming to IS 1180 (Part-1) 2014, copper wounded capacity 160 KVA, 11/0.433 KV complete,AC , 3 phase 50 Hz , oil immersed, naturally cooled, delta connected on primary side (11 KV HV side ) and star connected on secondary side (433 LV) in accordance with vector symbol DYN -11 (vector Group) with neutral brought out on secondary side (LV side ) with tapping at + 2.5%,+ 5%+ 7.5% off load tap changer gear in steps of 2.5 % including initail oil filling to appropriate level having dielectric breakdown strength > 50 KV, and all standard fitting as per IS 1180 PArt I 2014, mounted on PCC platfoorm, With fencing steel gate as per TD Drg CEPZ/ 98/TD/6. The unit rate of transformer includes the following accessories/Fittings:
(a) Non Detachable rating & terminal marking plates. (b) Lifting lugs for main tank ank and top cover . (c) Earthing terminals with lugs -02 Nos (d) thermometer pocket with cap, alongwith dial type thermometer -01Nos (e) Externally hand operated off circuit tap charging d4evice with locking arrangement (f) Oil conservator tank with oil filling hole & cap and oill level gauge. (g) Silica gel dehydrating breather with first charged silica gel. (h) Top filter Valve with plug. (j) Drain cum bottom filter valve with plug. (k) Air vent, Explosion vent, Fings etc. (l) unidirectional reversible roller -04 Nos (m) HV bushing -03 Nos (n) LV bushing -04 Nos (o) First fill oil. (p) Base channel 100x50xmm, 460 mm Long with hole to make them suitable for fixing on a platform or plinth including making locking arrangement. (q) First fill of fresh oil confirming to relevent IS and tested upto 50KV dielectric stregth. (r) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (s) Provision of 2 Nos danger boards 250x200 mm size made out of 1.6 mm thick M.S. plate, Vitreous enamelled white, with letters figure of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (t) Any other fitting /accessories so as to confirm the whole transformer to IS 1180 : 2014. Note:(i) Before installatonation of Transformer factory inspection should be carried.(ii) completion of work will be issued After SEI inspection and contractor's responsibility. (iii) Quoted rate includes the plinth of suitable size as per manufaturer recommandation and drg shall be approved by GE before installation.
Supply, installing, testing and commissioning disrtibution transformer step down of outdoor type,energy efficent level -III confirming to IS 1180 (Part-1) 2014, copper wounded capacity 200 KVA, 11/0.433 KV complete,AC , 3 phase 50 Hz , oil immersed, naturally cooled, delta connected on primary side (11 KV HV side ) and star connected on secondary side (433 LV) in accordance with vector symbol DYN -11 (vector Group) with neutral brought out on secondary side (LV side ) with tapping at + 2.5%,+ 5%+ 7.5% off load tap changer gear in steps of 2.5 % including initail oil filling to appropriate level having dielectric breakdown strength > 60 KV, and all standard fitting as per IS 1180 PArt I 2014, mounted on PCC platfoorm, With fencing steel gate as per TD Drg CEPZ/ 98/TD/6. The unit rate of transformer includes the following accessories/Fittings:
(a) Non Detachable rating & terminal marking plates. (b) Lifting lugs for main tank and top cover . (c) Earthing terminals with lugs -02 Nos (d) thermometer pocket with cap, alongwith dial type thermometer -01Nos (e) Externally hand operated off circuit tap charging device with locking arrangement (f) Oil conservator tank with oil filling hole & cap and oill level gauge. (g) Silica gel dehydrating breather with first charged silica gel. (h) Top filter Valve with plug. (j) Drain cum bottom filter valve with plug. (k) Air vent, Explosion vent, Fings etc. (l) unidirectional reversible roller -04 Nos (m) HV bushing -03 Nos (n) LV bushing -04 Nos (o) First fill oil. (p) Base channel 100x50xmm, 460 mm Long with hole to make them suitable for fixing on a platform or plinth including making locking arrangement. (q) First fill of fresh oil confirming to relevent IS and tested upto 60KV dielectric stregth. (r) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral. (s) Provision of 2 Nos danger boards 250x200 mm size made out of 1.6 mm thick M.S. plate, Vitreous enamelled white, with letters figure of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (t) Any other fitting /accessories so as to confirm the whole transformer to IS 1180 : 2014. Note:(i) Before installatonation of Transformer factory inspection should be carried.(ii) completion of work will be issued After SEI inspection and contractor's responsibility. (iii) Quoted rate includes the plinth of suitable size as per manufaturer recommandation and drg shall be approved by GE before installation. (iv) Level II new is not equivalent to level III
Material and labour for brick masonry platform (suitable for 200/160 KVA transformer) having size 2 mtr X 2 mtr and total height of 1.6 mtr (0.45mtr below ground level including excavation and earth work, 1.15Mtr above ground level including RCC slab 150 mm on top and refilling of sand/soil), PCC 1:4:8 type D2 in foundation, sub class B brick work in CM 1:4, 15 mm thick rendering in CM 1:6 on all sides of platform upto 150 mm below ground level, supply and fixing of 02 Nos of MS channel of suitable size for balancing of transformer, embedded in PCC 1:2:4 type B-1 upto 150 mm thick RCC slab, including provn of stair case on one side complete all as specified and directed.
S&F Joinitng Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories suitable for 3 Core XLPE armoured cable 95 Sqmm complete all as specified and directed.
Supply, laying and testing of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 Volts grade cross sectional area 3 core x 95 Sq mm. complete all as directed.
Supply and laying un-reinforced Precast Concrete cable cover class HV, type-1, flat size 300mmX180mmX40mm complete all as specified and directed.
Supply and erect 2 pole structure 11 mtr long 410 SP 55 consisting of steel poles with PCC foundations etc alongwith dropout fuse assembly with bottom outside dia and thickness of section with 193.7mmX4.8mm, LA 11 KV 65 kilo amps metal oxide type including excavation, getting out, pole foundation with PCC type D-2 1:4:8 (with 40mm nominal graded aggregate) coping of pole with PCC type-1 :3:6 (with 20mm graded aggregate) and removing surplus soil to a distance not exceeding 50m and making good surface all as specified and directed by Engr-in-charge.
S&F switch air break, gang operated HT 11 KV triple pole, mechanically operated, mounted on 12 insulators and steel frame with drop out fuse assembly (having 06 post Insulators including HT barrel fuse of suitable capacity as required at site), vertically or horizontally with operating mechanism worked from ground level, for current rating up to 200 amps complete including taking down existing unserviceable switch complete all as specified and directed. Note:- All fixing material ie suitable size and Nos of channels including nut bolts required for fixing the GOD is included in the quoted rate.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified. Note- For item No 9 & 10 upto 7.5 RM strip/wire with protection pipe deemed to be included in the quoted rate.
Supply, laying and testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 150 Sq mm. complete all as directed.
complete all as above item No 11 described here in before but 3.5 core 50 sqmm
complete all as above item No described here in before but 3.5 core 70 sqmm
complete all as above item No described here in before but 3.5 core 95 sqmm
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1.50 m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT/HT UG cable complete all as specified and as dirceted.
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed .
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3/4 pole 415 volts, 50 Hz, 100Amps 16 KA breaking capacity as incomer complete
S&F MCCB 125 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as directed as per existing model/make.
S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
Supply 'installation testing and commissioning of servo controlled oil cooled Voltage stabilizer for automatic operation copper wounded 3 phase, naturally oil cooled Outdoor type & designed for input variation between 340V to 460V with input voltage stabilized at 415V with accuracy (+/-) 1% and speed of correction 6 volts per second and capacity 160 KVA as per latest IS code complete all as specified & directed .
M & L for road cutting for laying GI pipe for protection of cable uptodepth 90 cm incl including making good the disturbed road and redressing the disturb surfaces of road with filling concrete type D-2 PCC in 1:4:8 (40 mm graded aggregate) complete all as specified and directed .
Supply and fixing 80 MM DIA GI pipe Light grade (ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge.
S&F Isolation transformer 160 KVA, 415/415V (Fixed Ratio), 3 Phase, 50 HZ, ONAN Cooled Oil Immersed Double Copper Wound Outdoor type complete with first filling of IS:335 ISI Marked filtered & dehydrated transformer oil Electrostatic sheild between primary 415V in star connected complete & other standard fitting/ acessories with Vector Group symbol Dyn-11.
Supply and fix GI strip in trenches or wall 32 x 6 mm galvanised iron strip complete all as specified and directed.
S&F 415V 10 KA 'B' curve MCB 40 Amps 4 poles complete all as specified and directed.
S&F 415V 10 KA 'B' curve MCB 63 Amps 4 poles complete all as specified and directed.
RAVINDRA BROTHERS
M/S Anand Enterprises
A B K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .