Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹17.3 L+₹40,430 (2.40%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹17.5 L+₹58,825 (3.49%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹17.5 L+₹59,890 (3.55%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹19.2 L+₹2.3 L (13.5%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹27.6 L
EMD Value
₹55,200
Closing Date
26 Feb 2022, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR AND RENEWAL OF INTERNAL ELECTRIC WIRING INCLUDING CERTAIN CONNECTED WORKS OF OTM ACCOMODATION AT AUNDH MILITARY STATION UNDER GE MH AND RH KIRKEE
2022_MES_506462_1
8285/E8
Open Tender
Civil Works
Item Rate
270 days
KIRKEE AND AUNDH
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹55,200
Yes
26 Apr 2022
7 Feb 2022
28 Feb 2022
7 Feb 2022
26 Feb 2022
21 Feb 2022
7 Feb 2022 - 14 Feb 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. all as specified and as directed.
M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated unsheated FRLS cable 1100 Volts for Phase, Neutral and earth drawn in to and including ISI marked PVC rigid metallic / non metallic on walls/ceilings/concealed with suitable clamps etc of suitable size including its accessories such as tee, bend ,elbow, socket complete and making good the disturbed surfaces, MS terminal box sunken to wall for housing Modular / piano type switches ,sockets,regulators etc complete all as directed and as specified for the One light point controlled by one switch
All as per item No 2 above but One Fan point controlled by one switch
All as per item No 2 above but One 5 pin 6 Amps socket outlet on independent board.
All as per item No 2 above but One 5 pin 6 Amps socket outlet on same board.
All as per item No 2 above but bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
All as per item No 2 above but one light point controlled by two way switch.
All as per item No 02 here-in-before but wiring with 2.5 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
All as per item No 02 here-in-before but wiring with 4.0 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for geyser on independent board complete all as specified and directed by Engr-in-charge.
Supply and replace in repairs, switch piano type pole one way 6 Amps ISI marked AC 230V all as specified and directed. (Make : Anchor Penta or eqv)
Supply and fix in repairs / replacement switch piano type 16 Amps i all as specified and directed
Supply and replace in repairs, switch piano type pole two way 6 Amps ISI marked AC 230V all as specified and directed.
Supply and replace in repairs, switch piano type pole one way 16 Amps ISI marked AC 230V all as specified and directed.
Supply and replace in repairs, Bell push, flush type, 6 Amp ISI marked AC 230V all as specified and directed by Engr-in-Charge.
Supply and replace in repairs, socket outlet 2 in1,3 pin 5 Amps ISI marked , AC 230 V all as specified and directed.
Supply and replace in repairs socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type ISI marked AC 230V all as specified and directed.
Supply and replace in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amps all as specified and directed.
Supply and replace in repairs Switch socket combination 2 in 1, 5 A flush type all as specified and directed
Supply and replace in repairs Switch socket combination 2 in 1, 16 A flush type all as specified and directed
Supply and replace in repairs, stepped fan regulator electronic type ISI marked AC 230V 120W all as specified and as directed.
Supply and replace in repairs, stepped fan switch type regulator electronic type ISI marked AC 230V 120W all as specified and as directed.
Supply and replace in repairs PVC ceiling rose 3-terminals ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Angle holder ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Batten Holder ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Batten Holder adopter ISI marked AC 230V all as specified and directed
Supply and replace in repairs Bell AC 230 volts all as specified and directed
Supply and replace in repairs Call bell ding dong AC 230 volts all as specified and directed
Supply and replace in repairs Call bell multimusic type AC 230 volts all as specified and directed
Supply and replace in repairs modular switch 1 way 6A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 2 way 6A 1 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 1 way 10A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 1 way 16A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular Bell push 1 way 6A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular socket 6A 2/3 pin combined 2 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular socket 6A /16A 2/3 pin combined 2module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs module (step type) fan regulator,120 watt - 2 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs Modular switch socket combination multipurpose 3 pin, 15A and one pin, 5A controlled by one switch 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 1module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 2 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 3 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 4 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 6 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 8 module complete all as specified and directed.
Supply and replace in repairs modular metal flush Box 1/2 module complete including taking down rusted metal box and necessary plastering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 3 module complete including taking down rusted metal box and necessary plastering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 4 module complete including taking down rusted metal box and necessary plastering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 6 module complete including taking down rusted metal box and necessary plastering work and finish with existing wall paint all as specified and directed.
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
Taking down old unserviceable/burnt sub main wiring of 4 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface conduit/concealed of suitable size including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 6 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface conduit /concealed of suitable size including 6 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 10 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 10 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface /concealed conduit of suitable size including 10 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down the unserviceable DB, Supply and replace distribution board factory made TPN 4- way vertical type with busbars & MCB TP as incoming, Double door metal type AC 415V suitable for fixing SP /TP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, Supply and replace distribution board factory made TPN 6- way vertical type with busbars & MCB TP as incoming, Double door metal type AC 415V suitable for fixing SP /TP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, fixing only distribution board factory made SPN 4- way vertical type with busbars & MCB SPN as incoming, Double door metal type AC 230V suitable for fixing SP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, fixing only distribution board factory made SPN 8- way vertical type with busbars & MCB SPN as incoming, Double door metal type AC 230V suitable for fixing SP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F Isolator TPN 63 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F Isolator TPN 100 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F MCB SPN 10 to 32 Amps .Make Havells/ Anchor/ Legrand/ Seimense /ABB
S & F MCB SP 5 to32 amps, .Make Havells / Anchor/ Legrand/ Seimense /ABB
Taking down and Hanging for Ceiling fan, Ceiling cable end, dismantling blades from removing C/F and blades deposited to MES store yard complete all as specified and directed by Engr In Charge
M & L for rewinding of ceiling fans of 1200 mm sweep of any make with supper enamelled copper winding wire appropriate gauge and after cutting the old burnt winding and cleaning the slots including varnishing and replacement of flexible cable 23/0.0076 mm to the required length, replacement of unserviceable bearing, PVC capacitor/terminal mounting as required including taking down and refixing, making connection and testing complete all as specified and directed by Engr-in-Charge.
All as per item No 61 above but ceiling Fan of sweep 1400 mm sweep all as speciifed and as directed.
All as per item No 61 above but Exhaust Fan with metal frame and of sweep 225-300 mm all as speciifed and as directed.
All as per item No 61 above but Exhaust Fan with metal frame and of sweep 450 mm all as speciifed and as directed.
All as per item No 61 above but Exhaust Fan PVC frame of sweep 225-300 mm all as speciifed and as directed.
Note for item No 61 to 65: (a) The contractor will collect the U/S ceiling fans, Exhaust fans, from JE through gate pass for repair in civil workshop. (b) In case, any item mentioned in note is not returned to the dept the cost of the respective item will be recovered in RAR/FB from the contractor. No claim in this regard will be entertained. Decision of Engr-in-charge wiil be final. (c) Bearings will measured and paid separately under relevant item of sch
Supply & replace broken wings of Exhaust Fan with metal frame of sweep 225-300 mm all as speciifed and as directed.
Supply & replace broken wings of Exhaust Fan PVC of sweep 225-300 mm all as speciifed and as directed.
Supply & replace capacitor for PVC Exhaust Fan( Square Type) 0.5 mfd all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
Supply and replace ball bearings of suitable size for 1200/1400 mm sweep ceiling fan complete all as specified and directed . Make : SKF/NBC or equivalent
Supply and replace ball bearing of suitable size for 225-300 mm sweep exhaust fan complete all as specified and directed . Make : SKF/NBC or equivalent
Supply and replace ball bearing of suitable size for 450 mm sweep exhaust fan complete all as specified and directed . Make : SKF/NBC or equivalent
Supply and replace, rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
M & L only capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
M & L only capacitor 4 mfd for Exhaust fan all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and as directed.
M & L for repairs to storage type elect. water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following tasks at different locations as directed:- (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous composition not liable to impart test or otherwise contaminate the water. (b) Replacement / repair of neon lamp / indicator lamp. (c) Replacement of the rubber / PVC gasket to ensure water tightness. (d) Testing of geysers after repairs.
Supply and replace in repairs thermostats ISI marked as per sample at site for geyser of capacity 25/35/50 Ltr of any make all as directed.
Supply and replace in repairs of stop valve/high pressure valve ISI marked as per site requirement or all as per directed.
Supply and replace in repairs heating element of rating 1.5/2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
Supply and replace in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 cm long for cold water connection all as specified and directed by Engineer-in-charge.
Supply and replace in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
Supply and replace in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
Supply and replace in repairs, 25 ltrs copper container for geyser all as specified and directed by Engineer-in-charge.
Taking down the existing electric meter from the position and re-fixing, connecting electric metres upto 25 Amps all as speccified and as directed.
M & L for 2 mm thick powder coated sheet metal bent in required shape and fixed on the existing meter board for mounting of the electric meters all as specified and as directed.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 x 100 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
M & L replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200 x 150 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
M & L replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250 x 200 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate.
Labour only for attending Arman complaints received through Mobile App/complaint slip by deploying necessary skilled tradesman with helper as required at site on working hours from 0830 Hrs to 1730 hrs on all working days at Md Accn Area, Aundh Mil station.
Note: - (i) The complaints will be entered in complaint slip by JE E/M MCM. (ii) The complaint slip should be returned to JE E/M on completion of the work with stores consumed. (iii) Any delay in attending the complaints for more than 03 days, a penalty of Rs 50/- per complaint will be adhered to the contractor. (iv) The details of stores consumed, complaint slip are to be produced during the RAR bills. (v) T & P, Minor spares like nuts, bolts, screws, washers insulation tape etc required for attending the complaints shall be provided by the contractor and the rate for the same is deemed to be included in the rate quoted..
Taking down old unserviceable conventional fitting and S & F wall mounted high quality indoor batten LED tube light with PVC housing,T-8 LED tube rod 20 Watt with T-8 LED Batten type with integral electronic driver 20 W, colour temperature 6500 K (4') , operating lifte 50000 hrs, lumen 1800-3000, diffused connecting with three core flexible copper wire from connector to ceiling rose / Angle Holder as per existing site requriement as directed by engineer in charge. Make: Halonix/Havells / Crompton Greaves
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Halonix/Havells / Crompton Greaves
S & F Recess mounting LED ultra modern design light fitting 36 watt, 2 x 2 , 600mm x 600 mm size with efficient LEDs including taking down unserviceable fitting of any type and make all as specified and directed. Crompton/Wipro/Philips and evivalennt make
M & L for repair and replace of unserviceable LED driver suitable for 36/40 watt LED panel light fitting 2 x 2 size on site all as specified and directed by Engr-in-Charge. Make: Halonix/Havells / Crompton Greaves
S & F Recess mounting LED ultra modern design light fitting 09 watt, 1 x 1, with efficient LEDs including taking down unserviceable fitting of any type and make all as specified and directed. Make: Halonix/Havells / Crompton Greaves
S & F in repairs 35 W Street /buidling security light fitting cast aluminium housing, toughened glass, IP 65/66, and pre wired with all accessories complete including entry for mounting on pipe bracket complete all as specified & directed.
Supply & fix Aluminium strip 25 mm x 3 mm complete with porcelain insulated saddles and fixing screws for fitting the strip.
Taking down carefully old unserviceable existing Galvanised iron strip 32 mm x 6 mm and Supply & fix Galvanised iron strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw.
Repair/maintenance of defective/rusted storage type solar water heater of capacity 200/500/1000 litre from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the solrar water heater in position, insulation of pipe lines complete with building, painting of solar water stand and water tank stand with black paint weather proof, repair of leakage including soldring/gas welding and repair of foundation, replacement of electric cable as per site requiement testing all as specified and directed.
S&F in replacement of solar heating element 3 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
M & L for Hot water water supply pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete all as specified and directed by Engr in Charge.
M & L for preparation of steel surface and applying of one coat of syntheic enamel paint white including writing of MES Nos with black paint complete to geysers of any capacity or make all as specified and directed by Engineer-in-charge.
Taking down old conventional KWH meter deposit on MES Store yard Supply & fix AC Three phase LTCT Type static energy meter of accuracy class 1.0, 3X 240 V, 50 Hz with Backlit LCD display of rating 60A -100A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power including CTs of suitable ratio class 1.0 all as specified and directed by Engr-in-charge. Make; L & T/HPL
Adinath Technical Services
metro electrical services
SBS Enterprises
ASHWAMEDH ENGINEERS
ONKAR ELECTRIC AND GENERAL STORE
M/S. Niksun Electro-Infra Private Limited
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .