| 1 | L1₹34.4 LAccepted-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.5 L+₹2.1 L (5.82%)Rejected-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L2 | Rejected-AOC Not Accepted | |
| 3 | L3₹37.8 L+₹2.4 L (6.82%)Rejected-AOC | L3 | Rejected-AOC Not Accepted | |
| 4 | L4₹42.4 L+₹7.0 L (19.7%)Rejected-AOC FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L4 | Rejected-AOC Not Accepted |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Mar 2025, 6:00 pmClosed
Garrison Engineer North Mumbai
Garrison Engineer North Mumbai Military Engineer Services Santacruz East, Mumbai 400029
MAINTENANCE AND UPGRADATION OF EXISTING AUTOMATIC STARTER PANEL AND MOTORISED VALVES SYSTEM IN DIFFERENT PUMP HOUSES, REPAIR / REPLACEMENT OF OLD UNSERVICEABLE FAN AND GEYSERS AND REPAIR/ MAINTENANCE OF LIGHTNING PROTECTION SYSTEM IN DIFFERENT BLDGS
2025_MES_697817_1
8231/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer North Mumbai
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer North Mumbai
₹90,000
Yes
28 May 2025
13 Feb 2025
15 Mar 2025
13 Feb 2025
13 Mar 2025
28 Feb 2025
14 Feb 2025 - 19 Feb 2025
Amount
Material & Labour for repairs/ re-wiring for Control panel suitable to fit latest PLC including replacement of base connectors, rewiring if required complete which consist of Programmable Logic Controller with I/O Module suitable to fit in existing Control Panel & HMI suitable for Programmable Logic Controller suitable for existing PLC Control panels with programming of PLC and HMI. HMI Make:- MITSUBISHI or equivalent Siemens or existing make/brand spare parts or any reputed suitable make and as approved by Engineer-in- Charge Note:- Any changes to control/communication circuits to be done in presence of OEM of panel manufacturer and Engineer-in- Charge
Supply & fix in repair Single Phase Preventor complete all as specified and directed by Engineer-in- Charge Model :VSP D2 Make - Minilec or equivenet make of L&T / Schneider / ABB / C&S
Supply & fix in repair Relay with base - 4 C/O, 220V DC complete all as specified and directed by Engineer-in- Charge Make : LEONE / IDEC
Supply & fix in repair LED Indicators of suitable size of Colour : Red / Yellow / blue/Green complete all as specified and directed by Engineer-in- Charge Make : ESBEE / TEKNIC/SCHNEIDER/C&S/L&T
Supply & fix in repair Pressure Switch 0 – 10 kg/sq.cm complete all as specified and directed by Engineer-in- Charge Make: Indfos/ Danfoss
Supply & Fix in repairs pressure gauge dial type 4" for measurement of the water pressure up to 14 Kg rating or as per existing size complete all as specified and directed. Make- Waarrie/H-Guru/FIEBIG/OMEGA
Supply & fix in repair Push Button with LED Indicator – 240V A.C.Colour : Red / Green complete all as specified and directed by Engineer-in- Charge Make : ESBEE / TEKNIC/SCHNEIDER/C&S/L&T
Supply & fix in repair NO Contact - 230V A.C.,3m Amps complete all as specified and directed by Engineer-in- Charge Make : ESBEE / SCHNEIDER / L&T/C&S/ABB
Supply & fix in repair NC Contact - 230V A.C.,3m Amps complete all as specified and directed by Engineer-in- Charge Make : ESBEE / SCHNEIDER / L&T/C&S/ABB
Supply & fix in repair/ replacement SMPS Input Voltage: 230 V, Output Voltage: 24 V complete all as specified and directed by Engineer-in- Charge Make: NHP/ SCHNEIDER
Supply and fix repair/ replacement Programmable Logic Controller 32 input and 32 output with communication port embedded in single unit complete all as specified and directed by Engineer-in- Charge Make :Mitsubishi
Supply & Fix in repair HMI for Programmable Logic Controller suitable for existing PLC Control panels complete all as specified and directed Make:- MITSUBISHI or equivalent Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved complete all as specified and directed by Engineer-in- Charge
Supply & Fix in repair I/O Module for Programmable Logic Controller suitable for existing PLC Control panels complete all as specified and directed Make:- MITSUBISHI or equivalent Siemens or existing make/brand of defective components/ spare parts or any reputed suitable make and as approved complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Coil with Solenoid Valve - 15mm 230 V a.c complete all as specified and directed by Engineer-in- Charge Make: Avcon/Jhonson Control
Supply & fix in repair Coil with Solenoid Valve - 10mm 230 V a.c complete all as specified and directed by Engineer-in- Charge Make: Avcon/Jhonson Control
Supply & fix in repair Magnetic Level Sensor complete all as specified and directed by Engineer-in- Charge Make: SMI/CRYSTAL/SPLASH
Supply & fix in repair Single phase Electric motor suitable for actuator for 80 /100mm dia butterfly valve complete all as specified and directed by Engineer-in- Charge Make: MARSH
Supply & fix in repair Single phase Electric motor suitable for actuator for 150mm dia butterfly valve complete all as specified and directed by Engineer-in- Charge Make: MARSH
Supply & fix in repair Water level controller complete all as specified and directed by Engineer-in- Charge Make: MARSH/SMI/SPLASH
Supply & fix in repair SS FLAP Butterfly valve of size 80/100 mm dia complete all as specified and directed by Engineer-in- Charge Make: AUDCO/ VIRGO/ INTERVALVE/L&T
Supply & fix in repair SS FLAP Butterfly valve of size 150 mm dia complete all as specified and directed by Engineer-in- Charge Make: AUDCO/ VIRGO/ INTERVALVE/L&T
Supply & fix in repair Capacitor for Actuator suitable for 80 / 100 / 150 mm dia Butterfly Valve complete all as specified and directed by Engineer-in- Charge.
Supply & fix in repair Resistor for Actuator suitable for 80 / 100 / 150 mm dia Butterfly Valve complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Limit Switch for Actuator suitable for 80 / 100 / 150 mm dia Butterfly Valve complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Actuator suitable for 80mm dia Butterfly valve complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Actuator suitable for 100 mm dia Butterfly valve complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Actuator suitable for 150 mm dia Butterfly valve complete all as specified and directed by Engineer-in- Charge
Supply & fix in repair Hand Wheel for Actuator suitable for 80 / 100 / 150 mm dia Butterfly Valve complete all as specified and directed by Engineer-in- Charge
Supply & Fix in repairs/replacement 2 core 1.5sqmm dia FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, 1100 Volts grade drawn through non metallic PVC conduit/Casing capping/concealed, including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge. Make:- POLYCAB/HAVELLS/PRIMECAB/FINOLEX./BENLO
Supply & Fix repairs/replacement 4 core 1.5sqmm dia FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, 1100 Volts grade drawn through non metallic PVC conduit/Casing capping/concealed, including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge. Make:- POLYCAB/HAVELLS/PRIMECAB/FINOLEX./BENLO
Supply & Fix repairs/replacement 6 core 1.5sqmm dia FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, 1100 Volts grade drawn through non metallic PVC conduit/Casing capping/concealed, including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge. Make:- POLYCAB/HAVELLS/PRIMECAB/FINOLEX/BENLO
Supply & Fix in repairs/replacement of high conductivity solid annealed bare copper industrial Telephone armoured cable, FR, PVC compoundconforming to ITD specification, 5 Pair, 0.5mm complete all as specified and directed by Engineer-in- Charge Make:- POLYCAB/HAVELLS/PRIMECAB/FINOLEX./BENLO
Supply and fix in repairs MCB 63 Amps, 4 pole 240 volts, 10KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.Make: Havells/ABB/siemems
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil for exposing of pipe etc complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and as directed by the Engineer-in-Charge
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Material & Labour for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and as directed by Engineer-in-Charge
Supplying and laying un-reinforced precast concrete cable cover, class LV, type I, flat size 250mm x 150mm x 40mm laid dry flat over cable perpendicular across the cable in trenches complete all as specified and directed Make- Mehtab/ Patel Furniture Mart/ Lucky Cement Block Works (Lc)/ Sukhi Enterprises
Cleaning of valve pit chamber of any size by taking out mud & muddy water and depositing the same at a distance n. exc 20 mtr away from pit including swipping free from all type of dirt including rectification the leakage of valve of any size by using of appropriate size and required packing materials for purpose complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Painting of motor pump base, discharge line within the pump house arealine and suction line complete with all accessories including panel board with scrapping thoroughly existing corroded paint and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge. Make : Asian paints/ Nerolac paints / Berger paints / Shalimar paints / Dulux
Supplying, laying and jointing new DI pipe of 100mm bore (Ductile iron pipe DN 100), spigot and socket ends, class K-7 with rubber gasket (Tyton) joint in any length, laid in trenches in proper alignment including necessary cut to length to match existing fitting/ pipes or insertion of new CI specials etc including taking down unserviceable CI/DI pipe line including all fittings, complete all as specified and as directed by the Engineer-in-charge. Note :- Excavation and earth work will be measured and paid separately. Make: Tisco / Electro Steel / Kesoram / Lanco / Jindal / Kalinga / Kapilansh.
ditto as per item no 42 above but for 150 mm bore pipe.
Material and labour for submain wiring complete with and including 2 runs of 1.0sqmm, two core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit, heavy duty of 25mm dia including accessories etc as required and fixed on walls and 1.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge. Note : Two runs of 1.0sqmm PVC insulated cable and one run of 1.0sqmm cable and one run of PVC conduit shall be measured as one unit length. Make of Cable-Plaza, Finolex, Havells, Polycab Make of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
Material and labour for earthing complete with Galvanised steel earth plate electrode 60cm X 60cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with 32 x 6mm GI earth strip, 7.5m long from earth point to test point and other end connected to control board / panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt not less than 50Kg, Benzonite powder 20 KG in each earthing packed upto maximum 30 cm on both side of plate for reducing the earth resistance complete and GI strip protected by 40mm bore light grade galvanized iron pipe complete all as shown in electrical plate No. 3 of MES schedule Part I, 2009 with PCC 1:2:4, type B1 in chamber wall, MS angle of size 50mm x 50mm x5mm with CI cover, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh and engraving of earth marking on nearby structure/ building with cement mortar 1:4 plate of size 200mm x 150mm x 15mm thick including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Contractor should submit test report of earthing after installation to Engineer -in-Charge
Material and labour for Earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to and including galvanised earth lead wire 4 mm dia, 7.5m long, duly protected by 15mm dia light grade GI pipe upto test point terminal block by means of bolts, nuts, check nuts and washers made out of galvanized iron or steel with provision of charcoal & common salt not less than 50Kg, Benzonite powder 20 KG in each earthing packed upto maximum 30 cm on both side of plate for reducing the earth resistance complete and GI wire protected by 15mm bore light grade galvanized iron pipe complete all as shown in electrical plate No. 3 of MES schedule Part I, 2009 with PCC 1:3:6, type C1 in chamber wall with CI cover and frame, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh and engraving of earth marking on nearby structure/ building with cement mortar 1:4 plate of size 200mm x 150mm x 15mm thick including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Contractor should submit test report of earthing after installation to Engineer -in-Charge
Material and labour for construction of new valve chamber of size 900mm x 900mm x 900mm ( Internal size) including necessary excavation and earth work in any type of soil, PCC foundation (1:3:6) type C-2, using 40mm graded stone aggregate as in base concrete 100mm thick, 15cm offset, 230mm thick brick work in CM 1:6 with 10 mm thick rendering internally and 15 mm thick externally in CM 1:4, 50mm thick PCC 1:2:4 type B1 as in coping, 6 mm thick MS cover with hinges and locking arrangement, fixed to angle iron frame made out of 40 x 40 x 6 mm MS angles complete with two coats of synthetic enamel paint over one coat of red zinc chrome primer on all metal surfaces & three coats of white wash on all plastered surfaces of valve chambers including dismantling of unserviceable valve chamber with rusted MS cover without disturbing the existing pipeline etc complete all as specified & directed by Engineer -in-Charge.
Supply, fix, joint and testing Cast Iron Sluice Valve heavy duty of 80mm dia, with stainless steel spindle, PN 1.6 (Flanged) with iron wheel head, hand operated, bronze body seat ring, jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable Sluice valve complete all as specified and as directed by Engineer-in-charge. Make: Kirloskar / Kartar / Upadhaya / Leader / Venus / L & T (audco)
Supply, fix and jointing steel water tubing of 80mm bore medium grade, galvanised iron with all fittings such as Tees, elbows, sockets, bends, unions, short pieces, nipples, brass nuts and diminishing pieces complete all as per IS 1239 including fixed to wall / ceiling or laid in floor with suitable size GI clamps including taking down existing GI pipe and making good disturbed surfaces as per existing surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Tata / Jindal / Surya Prakash / Zenith
Taking down ceiling fan/exhaust fan/wall mounted fan of any make /type/size/sweep, at site from any height of the building for any defects, servicing complete,repairs /overhauling including replacement of worn out parts/rewinding as required , spare parts and refixing in same position incl. sucessful testing on full load wit blade complete all as specified and directed by Engineer-in-Charge. Note- (i) Capacitor, split pin, 'U' clamp with rubber reel, PVC canopy and flexible wire will be measured and paid separately as "Supply only" (ii) Serviceable spares shall be reused. (ii) Rewinding shall be measured and paid separately.
Material and labour for opening the motor of ceiling fans of sweep 1200mm/1400mm, 230 volts, AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full load with blade and replacement of worn out minor parts like ball bearing, gun metal bushes, rubber reel etc complete all as specified and as directed by Engineer-in-Charge. Make-Deen Dayal, finolex,Atlas Note- (i) Serviceable spares shall be reused.
Material and labour for opening the motor of exhaust fans of sweep 300/380 mm, 230 volts,AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full load with blade and and replacement of worn out minor parts like ball bearing etc complete all as specified and as directed by Engineer-in-Charge. Make-Deen Dayal, finolex,Atlas Note- (i) Serviceable spares shall be reused. Make- Deen Dayal, finolex,Atlas Note- (i) Serviceable spares shall be reused.
All as per item no. 52 above but of 450/600 mm sweep complete all as specified and directed by Eng-in-charge.
Material and labour for opening the motor of wall mounted fans of sweep 400/ 600mm, 230 volts,AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full load with blade with eplacement of worn out minor parts like ball bearing etc complete all as specified and as directed by Engineer-in-Charge. Make-Deen Dayal, finolex,Atlas Note-(i) Serviceable spares shall be reused.
Supply only Fan capacitor 2.5 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Fentex, Tesla, Epcos, Havells
Supply only Fan capacitor 4.0 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Fentex, Tesla, Epcos, Havells
Supply only flexible wire 23/0.0076, three core, 1100 Volt, twisted, PVC insulated, copper conductor, multistranded, FRLS for connection complete all as specified and as directed by Engineer-in-Charge. Make: Polycab, Havells, Plaza
Supply and fix in repairs exhaust fan, made of sturdy Engineering plastic (PVC body) complete with louvers shutter, voltage 230 V, 50 Hz of sweep 250 mm including taking down existing exhaust fan etc complete all as specified and as directed by Engineer-in-Charge. Note: Old fan will be deposited in MES Store yard. Make:Usha, Crompton Greaves, Khaitan,Bajaj, Orient, Havells
Supply only MS nut, bolt 8mm dia, MS clamp of suitable size for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only down rod, MS, 15mm dia, heavy duty, 300/450mm long as per requirement for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC canopy for 1200/1400mm sweep ceiling fan as per existing size and make complete all as per specified and directed by Eng-in-charge.
Supply and fix in repairs ceiling fan regulator AC, 230 volts , 100 watts, electronic type, deluxe (step type) complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Anchor( Penta), Cona
Supply and fix in repairs new metal blades suitable for ceiling fan of 1200/ 1400 mm sweep complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs exhaust fan, made of metal body complete with louvers shutter, voltage 230 v, 50 Hz of sweep 250 mm including taking down existing exhaust fan etc complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan,Bajaj, orient Note: Old fan will be deposited in MES Store yard.
Material and labour for Point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5 sqmm (nominal area) ( Phase- R, Y , B, Neutral- Black), drawn through and including non metallic PVC casing / capping (not less than 20mm wide) (ISI marked) and accessories on surface of wall/roof with sunken type pressed steel/welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor 1.5sqmm as earth continuity conductor (green colour) and connecting to common earth dolly complete all as specified and as directed for one light / exhaust fan/ wall fan point/bell point controlled by one, one way switch complete all as specified and as directed by Engineer-in-Charge. Make of Cable- Anchor/ havells/finolex /Polycab/Plaza /Benlo of ISI mark as approved by GE Make of PVC Casing Capping-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme
All as per item No.65 here-in before but One 3 pin, 5/6 Amps socket point on the independent board controlled by one, one way switch.
All as per item No.65 here-in before but for one 3 pin, 5/6 Amps socket point, on same board with other switches controlled by one, one way switch.
All as per item No.65 here-in before but for 3 pin 15/16 Amps switch socket point , on independent board with 2.5sqmm copper cable and provision of 2.5sqmm PVC insulated, FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings, on the independent board controlled by one, one way switch, complete all as specified and as directed by Engineer-in-Charge.
All as per item No.65 here-in before but for 15 Amps power point , on independent board with 4.0 Sqmm copper cable and provision of 4.0 sqmm PVC insulated, FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings, on the independent board controlled by one, one way switch, complete all as specified and as directed by Engineer-in-Charge.
Cutting openings, through brick walls built in cement mortar for exhaust fan upto 300mm size, cleaning and stacking bricks, removing surplus serviceable bricks, etc.. to store, rubbish outside MD land and making good in cement concrete 1:2:4 type B-0 as required, rendering 10mm thick in CM (1:6) to match with the existing surfaces including grouting of bolts for mounting of exhaust fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) including suitable size of hanging clamp, nut and bolt etc complete all as specified and as directed by Engineer-in-Charge. Note: Old ceiling fan will be deposited in MES store yard Make: Bajaj Model Energos 28 or equivalent model of Usha, Crompton Greaves, Khaitan, Havells as approved by GE
Material and labour for preparing old surfaces of ceiling fan/exhaust fan/wall mounted fan/Geyser of any capacity or sweep, by scrapping and removing dust etc and filling cavities with one coat of filler and spray painting with synthetic enamel paint and writing MES Nos in block letters as per existing complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully storage type electric water heater (Geyser) of any capacity, carrying out servicing including replacement of various parts, if necessary, such as different sizes of screws and clamps, base assembly, washers, glands of all types/ valves / heating elements / Thermostat pipes / drain plug / thermal cut-out / safety valve and worn out minor parts to ensure water tightness including re-fixing in the position after testing complete all as specified and as directed by Engineer-in-Charge. Note : Heating elements will be measured and paid separately as "Supply only."
Supply and fix in repairs exhaust fan, made of metal body complete with louvers shutter, voltage 230 v, 50 Hz of sweep 450 mm including taking down existing exhaust fan etc complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan,Bajaj, orient Note: Old fan will be deposited in MES Store yard.
Supply only heating elements of capacity 1.5/2 KW, AC, 230 Volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs PVC heavy duty connecting pipe of 15 mm dia and 450/600 mm long with adaptor complete all as specified and as directed by Engineer-in-Charge.
Supply and fix electric water heater, storage type, steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE, 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, including taking down existing electric water heater etc complete all as specified and as directed by Engineer-in-Charge. Note: Old geyser will be deposited in MES Store yard. Make : Havells / Crompton / Racold/ Bajaj
Material and labour for preparation of old steel surfaces of water tank, staging, ladders, framework etc, over 10cm width or girth not otherwise described including scrapping and removing old painted surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer with all necessary staging, scaffolding etc as required complete all as specified and as directed by Engineer-in-Charge. Make : Asian paints/ Nerolac paints / Berger paints / Shalimar paints / Dulux
Material and labour for shifting of Solar water heater including base frame , ETC tube frame, hot & cold water storage storage tanks, water tank stagging, CPVC pipes etc complete set of any capacity and make, after dismantling of all electrical and water connection and carrying it to the new location, refixing it on any type of roof making electrical and water connections, installation testing, commissioning and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge
Supply & Fix in repairs rotational moulded polyethylene water storage tank (Cylinderical vertical including CI tank with locking arrangements as per BMC specifications) triple layered with ISI marked of 750 ltrs capacity with inlet & outlet connections, tank nipples, bends, sockets etc, hoisted and fixed in position complete all as specified and as directed by Engr-in-Charge. Make : Sintex/ Polycon/ Rotex
Supply & Fix in repairs rotational moulded polyethylene water storage tank (Cylinderical vertical including CI tank with locking arrangements as per BMC specifications) triple layered with ISI marked of 1000 ltrs capacity with inlet & outlet connections, tank nipples, bends, sockets etc, hoisted and fixed in position complete all as specified and as directed by Engr-in-Charge. Make : Sintex/ Polycon/ Rotex
Supplying and laying CPVC pipes, heavy duty, SDR 11 of outer diameter 25mm & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with suitable fixing clamps/ fastners including taking down existing pipes complete all as specified and as directed by Engineer-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supplying and laying CPVC pipes, heavy duty, SDR 11 of outer diameter 32mm & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with suitable fixing clamps/ fastners including taking down existing pipes complete all as specified and as directed by Engineer-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supplying and laying CPVC pipes, heavy duty, SDR 11 of outer diameter 40mm & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with suitable fixing clamps/ fastners including taking down existing pipes complete all as specified and as directed by Engineer-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supply & Fix in repairs Evacuated tube collector (ETC tubes) 58mm dia & 2100mm length including taking down old unserviceable tubes complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in repairs CPVC ball valves, heavy duty, SDR 11 of outer diameter 25mm, fixed with suitable solvent complete all as specified and directed by Engr-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supply & Fix in repairs CPVC ball valves, heavy duty, SDR 11 of outer diameter 32mm, fixed with suitable solvent complete all as specified and directed by Engr-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supply & Fix in repairs CPVC ball valves, heavy duty, SDR 11 of outer diameter 40mm, fixed with suitable solvent complete all as specified and directed by Engr-in-Charge. Make- FINOLEX/ Dutron/ SFMC/ Birla Aerocon/Astral
Supply and fix single pointed air termination aluminium rod, 12mm dia, 300mm long including taking down old unserviceable aluminium rod, all as specified and directed by Engr-in-Charge.
Supply and fix aluminium strip of 25 x 3.15mm , including taking down of old unsercivable aluminium strip, complete all as specified and directed by Engr-in-Charge. Note : Rate for Necessary insulator for fixing of strip is deemed to be included in the quoted rate.
Material and labour for Plain Cement Concrete 1:3:6 type C2 using 40mm graded stone aggregate as in coping of pole including necessary formwork for fair finished surfaces etc complete all as specified and as directed by the Engineer-in-charge
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos 8mm dia 25mm long hexagonal screws, including taking down old unserviceable complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying,connecting, testing & commissioning LT UG XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 Sqmm x 2 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : Earthwork excavation, DWC/GI pipe for cable protection shall be measured and paid separately in their respective items Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI)
-do- same as Item no. 93 above but of size 16 Sqmm 4 Core
-do- same as Item no. 93 above but of size 6 Sqmm 2 Core
Supply and lay double wall corrugated (DWC) HDPE pipe 40mm outer dia , as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N/ Rex Polyextrusion Ltd/ Finolex/ Prince Pipes and fittings ltd/Kisan/Supreme/JAIN IRRIGATION SYS/ Astral
Supply and fix in repairs galvanised iron pipe, light grade, 40mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: Tata/ Jindal/ BST/ Surya/ KS Engineering/ Zenith/ Swastik/ Prakash
Fixing only in repairs the disturbed existing aluminium strip of size 25 x 3.15mm with saddles and fixing screws and other accessories etc for roof conductors above ground at any location to its original places complete all as specified and as directed by Engineer-in-Charge.
Fixing only in repairs the disturbed existing Gl strip of size 32 x 6mm with necessary fixing screws and other acessories etc above ground level at any location to its original places complete all as specified and directed by Engr-in-Charge.
Material and labour for Pre-cast cement concrete block masonry 1:3:6 type C1, (using 20mm graded stone aqggregate), with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for laying crushed stone in substation by spreading first layer of smaller aggregate and compacting it to a thickness of about 40mm and spreading second layer of mix 50mm and 25mm stone aggregate in a ratio of 2:1 and spread them uniformaly with compacted layer to thickness of about 60mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning the area by removing all grass, weeds, roots and other materials and applying chemical for treatment to prevent future growth of weeds and grass complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Gl sheet of size 10 x 8 inch welded with 2.5 foot of angle iron for marking earth pit grouted on ground with PCC at different area complete all as specified and as directed by Engineer-in-Charge.
supply and fix plastic coating print in Gl sheet of size 10 x 8 inch for marking earth pit grouted on ground at different area complete all as specified and as directed by Engineer-in-Charge.
Note: Deduct Credit for demolished / dismantled material of Rs. (-) 1,02,800.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
EVEREST POWER CONTROL ENGINEERS (BID ID -3256192)
SHREE SIDDHIVINAYAK ENGINEERS (BID ID -3255313)
Bob Enterprises (BID ID -3256968)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .