| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹85.3 L+₹7.2 L (9.27%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹87.4 L+₹9.3 L (11.9%)Rejected-AOC PO PS JANG DISTRICT TAWANG ARUNACHAL PRADESH 790104 | JANG | TAWANG | ARUNACHAL PRADESH | 790104 | L3 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
11 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ 135 WE
HQ 135 WE C/O 56 APO
PROVISION OF 33 KV VOLTAGE STABILIZER (AUTOMATIVE VOLTAGE REGULATOR) AT MES 33/11 KV POWER RECEIVING HOUSE AT SUNDERBANI UNDER GE(N) AKHNOOR
2020_MES_373067_2
CWE/JA-17/2020-21
Open Tender
Civil Works
Item Rate
270 days
AKHNOOR
Class C Cat b iiii
11 documents required · 11 mandatory
₹1,000
GE NORTH AKHNOOR C/O 56 APO
₹1.6 L
16 Jan 2021
14 Oct 2020
13 Nov 2020
14 Oct 2020
11 Nov 2020
29 Oct 2020
14 Oct 2020 - 21 Oct 2020
60 days
Amount
Total amount of Schedule 'A' Part- I (Building Work) Note:This Schedule is not pre-priced by MES and the Pre-priced rate indicated as Rs 0.00 under col 6 signifies this fact only.
Total Amount of Sch'A'-Part-I (Building Work)
The Schedule'A'- Part II & III are pre-priced by MES.
Total Amount of Sch'A'-Part-II (EXTERNAL ELECTRIFICATION WORK)
Total Amount of Sch'A'-Part-III (INTERNAL ELECTRIFICATION WORK))
Total amount of Schedule 'A' Part- IV (Misc items) Note:This Schedule is not pre-priced by MES and the Pre-priced rate indicated as Rs 0.00 under col 6 signifies this fact only.
Terminals : (i) Bare Bushing for both input & outpur (ii) Aux connection suitable for 1.1KV grade PVC cable. Central Consturctional Features : The unit shall have three distinct features as under :- 1.Hand Control. 2. Motor contral 3. Automatic control. Hand Control : Hand Wheel will be located on the front of the regulator tank at convenient oprative height. Motor Control : Raise/Lower push button control by means of small single phase reversible geared motor of the permanent capacitor type shall be provided. The limit switches shall be provided to restrict the travel at extreme position. With this arragement it wound also be possible to privide remote control of the Regulating Unit. The reversible geared motor wound of STEP-SYN type. Automatic Control : For automatic correction of fluctuating supply voltage, provide Electronic relay which will sense the output voltage and provide signal to the driving motor for necessary corrections. Fittings & Accessories:- As per annexure attached. DC Power pack as per required voltage 110 volt.
Note : (a) Commissioning /first time energizating of the products in the presence of supplied by manufacture (OEM). The cost per man/day to & fro fare local converyance, lodging & boarding expenses will be charged by Contractor. (b) Both the tank shall be supplied with first filling of transformer oil conforming to IS-335 (latest addition) and other std fittings (c) The pre-inspection of equipment at factory by the rep of accepting officer. The fare of to & fro, local conveyance, lodging & boarding expenses will be borne by Contractor. (Transformer Parts) Items (a) & (c) above shall be housed in a sheet steel tank fitted with radiators and mounted on unidirectional rollers and shall have the following fittings :- (a) Lifting lugs (b) Earthing terminals (c) Rataing plate (d) Filter value top & bottom (e) Oil fitting hole (f) Thermometer pocket (j) Dial type oil temprature indicator with alarm and contacts (k) Explosion vent (l) Bochhoz relay with alarm and trip contracts (m) Air release plug.
Supply and laying & Testing of Cable XLPE insulated , insulation screening with extruded semi conducting compound in combination with copper tape , inner sheathed of PVC, galvanised steel , flat strip armoured and overall PVC sheathed cable conforming to IS 7098 (Part-2) 2011 with latest amendemnts with aluminium conductor 33 KV grade of size 3 core 95 sqmm, complete all as speciified and directed by Engr-in- Charge.
Supply,transporting, install , testing and commissioning of HT 36 KV, 3 phase, 50 cycles totally enclosed metal clad switchgear outdoor complete with Vacuum Circuit Breaker 1250 amp having repturing capacity upto 1500 MVA for use on system voltage 33KV. The circuit breaker and accessories shall confirm to IEC-62271-100 or IS 13118 and other relevant IEC/IS standard. The circuit breaker shall be complete with terminal connection oerating mechainsm, control cabinets, cable from yard to control room along with accessories like gland, terminal block lugs , necessary steel support structure and RCC foundation for CB and control cabinet . The circuit breaker shall be required to perform as per techincal parameter given below :- (a) Highest system voltage - 36 KV. (b) Nos of Pole -03 Nos (c) Rate lighting impulse withstand- 170KVp. (d) Type of mechanism - Spring closing/tripping. (e) Control circuit voltage - 110V DC. (f) Rated operating sequence- )-0.3 sec - Co -3 min-Co. (g) Rated break time - less than 60ms i.e not more than 3 cycle. (h) Aux. Contacts - 4 NO + 4 NC (additional 3 NO +3NC shall be provided through contact multiplication) (j) Degree of protection - IP 55 (IEC 56 (1991). (k) Arc control medium/Type of breaker -Vaccum. (l) Applicable standared : IS 55(IEC 56 (1991) (m) First pole to clear factor - 1.5 (n) Rated transient recovery voltage for terminal fault - 12.5 (o) Suitable for capacitor/Reactor switching duties : Min 100A. (p) Operating mechanism-Spring controlled (MWSC). (q) Maint free operation at 100% rated current - Min 10000 operation.(r) The breaker shall comply with the requirement of IEC-56 or IS:13118(1991) or IS 2516 part I . Breaker shall be porcelain clad and shall be supplied with all accessories as specification.
Auxiliary Power Supply :- The auxiliary electrical equipment for 33KV PC VCB suitable for operation on (the supply system) 230V, 1 ph, 50 Hz, AC & 110 DC. The Vaccum ciruit breaker shall provide rapid and smooth interruption of current under all conditions, completely suppressing all undersirable phenomena, even under the most severe and persistant short circuit conditions or when interrupting small currents, leading/lagging reactibe currents of rated capacity. The over voltage caused by the circuit breaker switching an inductive or capacitive load shall be within the limits. Shunt reactor switching capacity : The circuit breaker shall be capable of interrupting rated power with recovery voltage. Recovery voltage and power factor : The circuit breaker shall be capable of interrupting rated power with recovery voltage. Transformer charging current breaking capacity :- The circuit breaker shall be capable to interrupting small inductive currents. The insulation of the breaker will be suitable to withstand the di-electric test voltage corresponding to specific bais insulation level of the IS standard. The circuit breakers shall be designed for remote control from control room and in addition there will be provision for manual operation of circuit breakers during maintenance and for local tripping and closing by the normal means. The basic porcelain insulators of identical rating shall be interchangeable . The puncture strength of the insulators and the insulator shall be used would be type tested.
Supply, installation, commissioning & testing of 33 KV Control & relay panel indoor type (CRP) including numerical protection relay control metering & indicating accessories for porcelain metal clad VCB HT 33 KV 3 phase 50 cycle switchger outdoor with Vaccum circuit breaker complete. The panel shall be with back access double door arrangement, dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS sheet powder coated finish over one coat of red oxide, primer both side operating type including internal wiring using 1.1 KV FRLS insulated mustistranded cable ( 2.5 Sqmm for CT/PT and control circit ,numbered and colour coaded as per IS-5578/1984 having suitable entry for cable consisting with following :- (A) Main, Numerical Protection Relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current. Built in disturbance recorder and event logger to monitor the Sequence of Events (SoE) using upto 1000 event codes. The relay shall be communicable on IEC 61850 GOOSE platform, using RJ-45/USB/FO port and capable of Binary Signal Transfer between local and remote relay over Fiber Optic. (i) Line Differential with high set and low set (stabilized) with second harmonic restraint to bypass transformer inrush. The scheme will be implemented using Single Mode Fibre Optic protection communication link between local and remote relay.Suitable single mode Fiber optic port shall be part of the relay including connected items like LIU and Patch cord etc. (ii) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively (iii)Transient/intermittent earth fault protection (iv) Phase discontinuity protection (B) Flush mounted auxillary relays for :- (i) Trip Circuit Supervision (ii) Master Trip (iii) Fuse fail (PT) supervision operated (iv) SF-6 gas Presssure Low (v) DC supervision scheme. (C) Metering :- (i) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-Vector-Meter (Acc.Cl.0.5). (ii) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port.
(D) Indicating Lamp :- (i) Bus-01 Isolator ON/OFF (ii) Bus-02 Isolator ON/OFF (iii) Line Isolator ON/OFF/EARTH (iv) CB auto trip (v) CB ON (vi) CB OFF (vii) CB Spring Charge (viii) Trip circuit healthy (ix) DC Available LED with push-button (x) R-Y-B Phase LED Indication (E) Semaphore indicator :- (i) Circuit Breaker ON, OFF (ii) Bus-01 Isolator ON, OFF (iii) Bus-02 Isolator ON, OFF (iv) Line Isolator ON, OFF, EARTH (F) Control switches/Push Buttons :- (i) Trip-Neutral-Close Switch for Circuit Breaker Control - 01no. (ii) MCB for AC isolation - 01no. (iii) MCB for DC isolation - 01no. (iv) Heater switch with thermostat - 01no. (v) 3-pin socket with ON/OFF switch - 01no. (vi) CFL Lamp with ON/OFF switch - 01no. (G) 08-Window Annunciator with hooter and Mute, Acknowledge, Reset and Test buttons for:- (i) OC Trip Alarm (ii) EF Trip Alarm (iii) Line Differential Trip Alarm (iv) PT Fuse Failure Alarm (v) SF6 Gas Pressure Low Alarm (vi) Trip Circuit Failure (vii) Spare. (H) Test Terminal Block for CT. (I) Suitable terminal arrangement along with Light Interface Unit, Patch-cord and associated port for spliced connection with external armoured fibre-optic cable shall be provided for achieving pilot-wire connection (line-differential). Note : Control panel shall be provided separately at Sub Stn Bldg. The cost of control panel & copper conductor cable of suitable size for VCB to control panel , outdoor CT/PT to control panel is deemed to be includded in the quoted item rate.
Earthing complete with galvanized iron earth plate electrode 600x600x6mm thick buried directly in ground vertically with its top edge not less than 2.25m below ground level.The earth plate shall be covered with 300mm thick mixture charcoal dust and salt all around below and top. The earth plate shall be connected to GI Strip 32x6mm thick GI bolt nuts and washers strip shall be taken into and incl test point including 40mm dia light grade pipe galvanized 3m long and 30cm perforated at bottom and plugged with GI tubing at top complete all as per electrical plate No. 3 of SSR Part I as directed. The rate includes material & labour for the following :- (i) Excavation and earth work for drilling hole for electrode in any type of soil. (ii) PCC pit in cement concrete 1:2:4 type B1, Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B1 , reinforced with welded steel wire fabric weighing not less than 1.87kg/Sqmtr.(iii) Funnel with watering pipe GI tubing 20mm nominal bore light grade and lugs etc complete all as specified and directed. (iv) 40 mm nominal bore med grade GI protection pipe 5 mtr long for protection of earthing lead complete all as specified and directed. (v) Requisite quantity of common salt and characoal. (vi) Testing of earthing.
Supply and laying PVC insulated PVC sheathed cable galvanised steel strip or wire armoured, electric control cable (heavy duty) with stranded copper conductor of size 4 sqmm, 4 core 1100 volts grade, complete all as specified and directed.
Supply & fix , Single phase , Current Transformer , Outdoor type, Oil cooled, paper insulated suitable for 33 KV supply system with neutral solidity grounded with initial oil filling complete of ratio 400/5-5amp, burden 15 VA, accuracy class 1.0/5P10, complete all as specified and directed. Make- AE/Electricfield or Equivalent.
Supply & Fix, Single phase, Potential Transformer (PT) , Outdoor type, Oil cooled of ratio 33 KV /root 3/110/ root 3/110/root3, class 0.5-3 , burden 50 VA-50VA, insulation level 70/170KV with initially filling of transfomer oil, complete all as specified and directed. Make- AE/Electricfield or Equivalent.
Supply , fix & Labour for GOD 33 KV 400 amp horizontal double break triple pole outdoor gand operated centre post rotating manually operated isolator having 12.5 KA (RMS) for 3 sec short ckt rating with 9 Nos 33 KV capacity and pin type post insulator with 320 mm cleavage distance and pedestal of height of 200 mm to maintain line earth clearage of 370 mm mechanically inter locked triple pole earthing with having independent manually oprated handle , complete with supporting structure of suitable channel , nuts & bolts etc, complete all as specified and directed.
Supply and fix cable jointing kit of 33 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 sqmm to 120 sqmm, complete all as specified and directed.
Material & Labour for construction of brick masonery PCC plateform for Automatic Voltage Regulator of size 4 x 4 x 1.2mtr (height) complete, PCC flooring includng excavation, earthwork, Load bearing channel including white wash, complete all as specified and directed.
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and output 230+/- 1% of capacity 2 KVA is equipped with a maintenance free sealed Lead Acid battery . The out put power capacity of the UPS is 600watts/1000VA and nominal ouptu voltage is 230V, complete all as specified and directed. Make- APC, Microtek or its equivalent.
Supply & fix Disc type insulator porcelain viterous white/brown/green ball & socket type three in series disc for tension with tension clamp for conductors suitable for working pressure 33KV, complete all as specified and directed.
S& F Pin type insulators porcelain viterous white/green ball ans socket type three in series disc assy for tension with tension clamp for conductors, suitable for working pressure 33 KV, complete all as specified and directed.
Supply and lay stone aggregate n.exc 63mm of broken stones or boulders deposited , spread and levelling in layers n.exc 15 cm thick with providing, complete all as specified and directed.
S& F LED tube light fitting 1 x 20W batten complete all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable of size, complete all as specified and as directed. Model - Trim Linea of Make : Cropmton Greaves Cat Part No. LCTLN-20-CDL or equivalent to BAJAJ/Philips
S& F LED building security light fitting 1 x 20W made upto pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection with suitable size of bracket and clamp to fix on wall complete all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable of size, complete all as specified and as directed. Model - ASTRA NEO of Make : Cropmton Greaves Cat Part No. LSTS-20-CDL/NL-M or equivalent to BAJAJ/Philips
S& F heavy duty exhaust fan 450mm sweep, complete all as specified and directed.
S& F heavy duty ceiling fan 1400mm sweep, complete all as specified and directed.
S& F LED bulb 9 watt, complete all as specified and directed.
JAZZCON ENGINEERS PVT LTD
N K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .