Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹61.4 LAccepted-AOC 376A 10TH CROSS 4TH PHASE 4TH MAIN PEENYA INDUSTRIAL AREA BANGALORE BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | ₹61.4 L | 1 | Accepted-AOC L1 Bidder |
| 2 | Rejected-Technical 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | - | - | Rejected-Technical Rejected for all quoted items |
| 3 | Rejected-Technical BEGUSARAI | KHAGARIA | BIHAR | 848201 | - | - | Rejected-Technical Rejected for all quoted items |
| Sl No | Description | Qty | Unit | Banavathy Power Systems Private Limited |
|---|---|---|---|---|
| 1.00Design. Engineering, Manufacturing , testing at works ,Supply of materials, packing & transportation of 1250 KVA, 11/0.433kV transformer, 415 V Switchgears of 2000A bus-bar rating, outdoor type compact substations consisting of isolators, HV and MV distribution boards, transformers, power factor improvement capacitors, as per job specification No. 214227C-00-JSS-1625-0001, Single Line Diagram Drawing No. 214227C-00-DW-1652-0002 and all other attachments attached with this tender. | ||||
| 1.01 | The package substation shall consist of:
• 630A, 11kV, 3 phase,50Hz, 26.3kA for 1 second, VCB Breaker Panel
• 1250kVA, 11kV/433V, ONAN, Dyn11, OCTC with tapping range of ±5% in steps of 2.5%, 3 Phase, Oil type, efficiency level-2 as per latest IS 1180: 2021, Distribution Transformer with standard fittings. Ammeter shall be Class 1.0.
• 415V, 3 Phase, 50Hz, 50kA for 1 second, MV Switchboard with 2000A ACB incomer, 1 No. of 400A MCCB feeder, 2 Nos. 250A MCCB feeders, 2 Nos. 160A MCCB feeders, 2 Nos. 125A MCCB feeders & 4 No. 63 A MCCB feeder as outgoing.
• KWH Meters in incomer & all outgoing feeders of MV switchboard required for billing of construction power supply.
• Lighting system inside substation accompanied with lighting distribution system.
• APFC panel with required protection- 200 kVAR with incomer of 400 A MCCB, 8 step APFC Relay, Indicating lamps, Digital VAF meters, CTs. Cap bank details: 50 KVAR- 3 nos. with 125 A MCCB, Capacitor duty contactor, Lamps & Push buttons, 25 KVAR- 2 nos. with 63 A MCCB, Capacitor duty contactor, Lamps & Push buttons.
All incoming and outgoing ACB & MCCBs shall be with 3 pole design.
• All protection & metering as required.
Suitable rating of DC Power pack for control circuit of HV switchgear shall be included in the supply.
LOOSE MATERIAL SUPPLY:
Supply of numerical relays, CTs, CBCTs, MFM, Ammeters and other items as per Annexure-1 (BOQ) and Annexure-2 (Make of Components). | 1 | Lot | 66,16,000 ₹78,06,880 Lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
22 Jul 2024, 2:30 pmClosed
Krishan Pal Singh
Technip Energies India Ltd. A4, Sector-1 Noida Uttar Pradesh 201301
Design, Engineering, manufacturing, procurement of materials and bought out components, assembly at shop, testing at manufacturers works, inspection by TPIA, packing, supply of COMPACT SUB-STATION (CSS)
2024_REFHQ_178333_1
TP/214227C/DR/1625-001/1023
Open Tender
Electrical - All
Supply
150 days
IOCL DIGBOI REFINERY
As per tender Documents
6 documents required · 6 mandatory
₹20,000
Yes
Off line as well as Online as per tender details
20 Aug 2025
21 Jun 2024
23 Jul 2024
21 Jun 2024
22 Jul 2024
12 Jul 2024
21 Jun 2024 - 28 Jun 2024
2 Jul 2024
Design. Engineering, Manufacturing , testing at works ,Supply of materials, packing & transportation of 1250 KVA, 11/0.433kV transformer, 415 V Switchgears of 2000A bus-bar rating, outdoor type compact substations consisting of isolators, HV and MV distribution boards, transformers, power factor improvement capacitors, as per job specification No. 214227C-00-JSS-1625-0001, Single Line Diagram Drawing No. 214227C-00-DW-1652-0002 and all other attachments attached with this tender.
The package substation shall consist of: • 630A, 11kV, 3 phase,50Hz, 26.3kA for 1 second, VCB Breaker Panel • 1250kVA, 11kV/433V, ONAN, Dyn11, OCTC with tapping range of ±5% in steps of 2.5%, 3 Phase, Oil type, efficiency level-2 as per latest IS 1180: 2021, Distribution Transformer with standard fittings. Ammeter shall be Class 1.0. • 415V, 3 Phase, 50Hz, 50kA for 1 second, MV Switchboard with 2000A ACB incomer, 1 No. of 400A MCCB feeder, 2 Nos. 250A MCCB feeders, 2 Nos. 160A MCCB feeders, 2 Nos. 125A MCCB feeders & 4 No. 63 A MCCB feeder as outgoing. • KWH Meters in incomer & all outgoing feeders of MV switchboard required for billing of construction power supply. • Lighting system inside substation accompanied with lighting distribution system. • APFC panel with required protection- 200 kVAR with incomer of 400 A MCCB, 8 step APFC Relay, Indicating lamps, Digital VAF meters, CTs. Cap bank details: 50 KVAR- 3 nos. with 125 A MCCB, Capacitor duty contactor, Lamps & Push buttons, 25 KVAR- 2 nos. with 63 A MCCB, Capacitor duty contactor, Lamps & Push buttons. All incoming and outgoing ACB & MCCBs shall be with 3 pole design. • All protection & metering as required. Suitable rating of DC Power pack for control circuit of HV switchgear shall be included in the supply. LOOSE MATERIAL SUPPLY: Supply of numerical relays, CTs, CBCTs, MFM, Ammeters and other items as per Annexure-1 (BOQ) and Annexure-2 (Make of Components).
Description of Work / Item(s)
Two Year Spares of CSS
2 years Normal operational & maintenance spares (as per vendor recommendation) against , item Sr No 1.01 (Spare no. - 1.01 (Mention the spare name-Qty-Unit)
Spare no. - 1.02 (Mention the spare name-Qty-Unit in unpriced bid)
Spare no. - 1.03
Spare no. - 1.04
Spare no. - 1.05
Spare no. - 1.06
Spare no. - 1.07
Spare no. - 1.08
Spare no. - 1.09
Spare no. - 1.10
2 years Normal operational & maintenance spares (as per vendor recommendation) against , item Sr No 1.01 (Spare no. - 1.01 (Mention the spare name-Qty-Unit)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .