| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.4 LAccepted-AOC | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹24.9 L+₹2.2 L (9.58%)Rejected-Finance | 2 | Rejected-Finance Not lowest bidder | |
| 3 | 3₹25.4 L+₹2.6 L (11.5%)Rejected-Finance | 3 | Rejected-Finance Not lowest bidder | |
| 4 | 4₹26.0 L+₹3.3 L (14.5%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 4 | Rejected-Finance Not lowest bidder | |
| 5 | 5₹26.4 L+₹3.7 L (16.2%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
29 Dec 2020, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Military Engineer Services, Bathinda Mil Station - 151004
as per name of work
2020_MES_397833_1
CA NO CWE BTD 68 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE North Bathinda
₹82,000
Yes
8 Jan 2021
24 Nov 2020
31 Dec 2020
24 Nov 2020
29 Dec 2020
15 Dec 2020
24 Nov 2020 - 5 Dec 2020
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site including cutting holes for removal of hold fast complete.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and removing from site complete.
Taking down shutters of any description not exceeding 1 Sqm each and removing from site complete.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and re-fixing in the same opening including easing and adjusting including renewal of unserviceable screws etc complete.
S&F factory made solid PVC door frame of size 60mm x 30 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified in Preamble 8B.3.1 of SSR Part -II (2010) and all as shown on drawing of SSR Part-II (2010).
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site all as per instruction and drawing shown for item No 8080 of SSR Part II on Sl Page No 156.
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section.
S & F 100 mm long stainless steel butt hinges, medium weight.
S & F 150 mm aluminium handles, fabricated type, anodised.
S & F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, complete, all as specified of frame size 125 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
All as per item No. 11 above but frame size 105 x 60 mm
All as per item No. 11 above but frame size 75 x 60 mm
M & L for PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregate in filling in chowkats/ door frame or bed block of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete.
S & F MS framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, not exceeding 10 Kg each brackets, conforming to Fe 290 Gde E-165.
S & F 35mm thick factory made panelled shutter (two panel) plain framed with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces conforming to IS-3097 exterior grade kiln seasoned and chemically pressure treated of second class hard wood rails and styles and the size of rail and style as per IS-1003 (Part I).
S & F factory made glazed and skeleton shutters 35mm thick using second class hard wood open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24(a); all as specified complete.
M&L for 18 / 19 mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber frame-work.
S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised of 30 mm width of flap (when open).
S&F 100 mm size Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300mm.
S & F 75 mm mild steel pressed handles, oval type, stove enamelled black.
S & F floor door stopper of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm.
S & F 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete
S&F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat painting all as directed.
S & F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F factory made top hung type steel ventilator with glazing bar, hinges, steel pegs complete.
S & F MS framed work such as grills, gratings, guard bars etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips size not exceeding 1.5 Sqm each pane complete.
S & F sheet glass, 4 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed with oil putty or wooden beads including Provn of glazing pins/spring clips wherever necessary complete.
S & F 4 mm thick figured glass, pin head or obscured or frosted type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete.
S&F in replacement stainless steel CP pipe 25 mm dia, wall thickness not less than 20 gauge as curtain rod fixed with and including fancy type brackets and decorated end knobs (finials), stop roller etc fixed on wall for doors and windows curtains, cuttig as per required length and fixed at site including fixing arrangements, rawl plugs, screws etc including taking down any type of curtain rod / pelmet boxes complete.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and pre cast concrete articles.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6).
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for.
M&L for sunken treatment to sunken floor with polymer modified mortar using DR fixit pidicrete or equivalent model of approved make from list of makes attached in tender documents, making of angle fillets all around the perifery of the wall with polymer modified mortar using DR fixit pidiproof LW+ @220 ml per bag of cement. Sealing sanitary pipe inserts, electrical fitouts etc provided in the floor and walls with bath seal traps, grouting the gaps around pipe inserts with bathseal grout or DR fixit micro concrete. Applying two coats of DR fixit bathseal WPC in the sunken areas and extending it upto 150mm above the finished floor level which include laying of a 150mm wide strip of an open wooven glass fibre mesh over the angle fillet on the first coat while it still wet laying a protective 10mm thick in cement mortar (1:3) plaster admixed with DR Fixit Pidiproof LW @ 220 ml per bag of cement complete all as per manufacturers instruction. (Make: Dr Fixit/ Fosroc/ BASF/ STP) NOTE :- (i) Complete treatment shall be carried out by authorized applicators of water proofing manufacturers . (ii) WP Materials shall be measured and paid for separately.
Supply only liquid water proofing material, ISI marked.
M&L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling of sunken floor including demolition of existing PCC.
M & L for 25 mm thick PCC (1:1.5:3) type A0 using 12.5mm graded stone aggregate as in sub base of sunken floor.
Demolition of brick tiles or terracing tiles, single layer on roofs including removing the demolished material exceeding 1 km and not exceeding 2 km away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 200 m away from site and disposal off in low lying area complete.
M&L for wire brushing and cleaning top surfaces of roof slabs etc, including washing the roof surface with water and making the surface free from mud etc complete all as specified.
M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and fair complete all as specified. (Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.)
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.30 kg/Sqm and providing and laying 3 mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm and tucked into the chases including ponding test all as specified and directed.
M&L for Lime concrete in lime mortar ratio (1:3) using 40 mm graded brick aggregate, laid to slope as directed by Engineer in charge over RCC roofs as padding complete alll as specified. Note: Minimum thickness of lime concrete at lower end shall not be less than 50mm.
M&L for 20- 22 mm thick factory made PCC tiles of size 250mm x 250mm with grey cement and no pigment , bedded in cement mortar (1:4) 15 mm thick and joints grouted flush in CM (1:3) mixed with @ 5% of crude oil by weight of cement complete all as specified.
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing material as in benching, kerbs, mud stops, along side walls adjoining to roofs and similar items complete. (Water proofing material shall be measured and paid for separately).
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3).
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store.
Refixing of old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.)
Refixing of old 20 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.)
M & L for 15 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors.
M & L for 20 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting exceeding 10cm but not exceeding 20cm girth in brick walls.
S&F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc all as directed.
S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 210 gram).
S & F in repairs Gun metal globe or Gate valve , with iron wheel , screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe.
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe.
M & L for 40mm bore low density polyethylene pipes (LDPE) of pressure rating 6 Kgf / sqcm, fixed complete to walls, ceilings or in floors etc.
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor.
S&F in repairs vitreous china wash down water closet pan (EWC) (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)
S&F in repairs vitreous china wash basin, white, flat back, size 550mm x 400mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs.
Supply only pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe for 15 mm bore dia of pipe.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets.
Supply only flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level flushing cistern.
S & F PVC connections 15 mm bore, 450 mm length, heavy duty, with PTMT nuts.
S&F in repairs stop valves / angle valves , cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F brass chromium plated soap dish fixed to wall with brass screws as per Cat Part No AQN-7731 of Jaquar or equivalent Cat Part of make approved in Appendix attached here-in-after.
S&F swivel shower of chromium plated of size 65 to 90 mm for fixing with 15 mm bore dia of pipe as per Cat Part No OHS-1989 of Jaquar or equivalent Cat Part of make approved in Appendix attached here-in-after.
S&F stop valves, chromium plated, concealed type long shunk, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe as per Cat Part No FON-40053 of Jaquar or equivalent Cat Part of make approved in Appendix attached here-in-after.
S&F brass chromium plated tubular towel rail, 20 mm dia, D type, 600 mm long between flanges fixed with CP screws and wooden cleats as per Cat Part No CAN-1101 S of Jaquar or equivalent Cat Part of make approved in Appendix attached here-in-after.
M&L for 100mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1.
S&F 100 mm size cast iron gully trap, square or round mouthed, type P or S.
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches including dismantling old pipes.
S&F 100mm cast iron sanitary connection socket to fit WC out-let.
S & F 100mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches.
S & F 100mm dia cast iron bends/T/Y (any radius), diminishing pieces or tapers (large bore measured).
S & F 100mm dia cast iron cowls.
Excavation in trenches, not exceeding 1.5 metres wide and not exceeding1.5 mtrs in depth for foundations etc, not exceeding 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers not exceeding 25cm thick.
Removing excavated soil to a distance not exceeding 50 mrtres and depositing where directed at a level not exceeding 1.5 m above the starting point.
M & L for salt glazed stoneware drain pipes, grade 'A', laid in trenches and jointed complete for 150mm internal dia of pipe including dismantling of existing drain pipes of any type and size, jointed in cement mortar all as directed.
M & L for concrete bed to 150 mm bore dia of drain pipes including packing under, and haunching against the sides of the pipes after they are laid and tested; in PCC (1:3:6) type C2 using 40mm graded stone aggregate.
Cutting into existing manholes, sump for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed.
S&F PVC (SWR) 110mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, fixed to walls with and including 40 mm x 3mm GI flat clamp including taking down old pipes and fittings.
S&F PVC (SWR) 110mm bore bends / shoes of any radius.
Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement mixed with liquid water proofing material as per manufacturer's instruction complete all as specified. (Liquid water proofing material shall be measured and paid for separately.)
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified.
M&L for preparation of newly plastered or unplastered surface and applying three coats of white wash on ceilings.
M&L for preparation of old treated surfaces of ceiling and applying one coat of white wash on ceilings.
M & L for preparation of newly plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
M & L for two coats of cement based paint over a coat of alkali resistant primer on newly plastered wall surface including preparation of surface.
M&L for scrap down and preparation of surfaces already plastered external walls and apply two coats of Cement base paint over a coat of alkali resistant primer all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish to a distance exceeding 1 km but not exceeding 2 km.
M & L for non skid coloured ceramic tiles of size minimum 600mm x 600mm, 8 to 9 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
M & L for non skid coloured ceramic tiles of size minimum 400mm x 400mm,78 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
S&F glazed ceramic coloured / printed tiles 450 x 350mm, 7 to 8mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile.
M & L for machine cut kota stone slab flooring minimum size 450 mm x 450 mm, 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 20 mm thick Screed bed or bedding layer in CM (1:6).
All as per item No 106 above but in vertical surfaces such as steps , riser , skirting, dado and pillars, 15 to 18 mm thick, as directed at site including 10 mm thick rendering as backing coat in cement mortar (1:4).
M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces.
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces.
M & L for painting to old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
M & L for painting to old wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement.
Demolition of PCC in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing the debris exceeding 1 KM but not exceeding 2 KM as directed by Engineer-in-Charge.
M&L for machine pressed rubber moulded precast interlocking paver block with grey cement and pigment, factory made, any shape and size, conforming to IS 15658-2006 of 60 mm thickness, made out of M-35 grade & including minimum 25mm thick sand cushioning below interlocking paving block complete laid dry of any description in floors, aprons etc complete all as directed.
Welding in repairs n.exc 2.5 cm in length for thickness of metal to welded n.exc 6mm.
M & L for providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron.
Demolition of RCC as in roof slabs (other than ground floors), beams, stair case, landing, chajjas, and similar suspended work (reinforcement cut as required to facilitate demolition).
M & L for M-25 design mix concrete using 20 mm graded stone aggregate in chajjas / beams and slabs and the like, finished exposed surface fair and even. (Reinforcement and form work shall be measured and paid separately)
M & L for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Use and Waste of formwork to soffits and sides of chajjas and similar work including attached pillasters, buttressess, etc; vertical or to batter for flat fair finished surface of concrete.
Internal Electrification
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc including concealed conduit and sunken boxes and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in existing concealed conduit with new sunken box and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 123 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No 123 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 123 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including new sunken box and 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 127 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No 127 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 127 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
S & F semi modular Switch, flush type, single pole, one way, 5/6 Amp .
S & F semi modular Switch, flush type, single pole, one way, 15/ 16 Amp .
S & F semi modular socket, multipurpose, 2 in 1, 5 Pin, 6 Amp, flush type. (Note: Switch and socket shall be of same make.)
S & F semi modular socket outlet universal, multipurpose, 2 in 1, 3 Pin 6 Amp and 6 pin 16 Amp, flush type. (Note: Switch and socket shall be of same make.)
S&F, fan regulator electronic step type (1-5), socket type 230-240 Volt, AC supply, complete all as specified and directed.
S & F ceiling rose, 3 plate, surface bakelite type, Polycorbonate body, 6 Amps, 250 Volts AC, 65 x 50 mm, three terminal (ISI marked) complete all as specified.
S & F Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection including taking down old unserviceable MCB complete all as specified.
S & F MCB, TPN, 63 Amps, 'C' curve , 415 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F isolator SPN 40 Amps, 'C' curve , 240 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable isolator.
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting all as directed.
S & F LED mirror light fitting of 12/14 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 12/14 watt tube rod all as model No LCL-14-CDL of Crompton with 14 watt rod or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting.
S & F energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified including taking down old unserviceable existing street light fitting of any type and capacity from pole along with accessories.
M&L for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 votls grade drawing through existing PVC concealed conduit including taking down old unserviceable sub main wiring complete all as specified. Note:- Two runs of cable and one run of earth wire shall be measured as one unit.
M & L for sub main wiring with 2 single core cable PVC insulated unsheathed of copper multi strandard conductor FRLSH cable of size 6 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 4 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit.
M & L for 15mm bore GI pipe, light grade, with all fittings and fixed complete to walls and ceilings or laid in trenches or buried in ground for protection earthing lead wire complete all as specified.
M & L for earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required.
M & L in replacement of earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
M/s Kamal Constructions
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s MITTAL CONSTRUCTIONS
V K CONTRACTOR
M/s Balvinder Singh Engineer and Contractors
SAPNA BUILDERS
M/s PANKAJ KUMAR
M/s Nuway Constructors India Pvt. Ltd.
BANSAL BUILDERS
VISHAV CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .