Tender Value
₹2.8 Cr
EMD Value
₹1.5 L
Closing Date
6 Oct 2020, 6:00 pmClosed
SUPERINTENDING ENGINEER, TNPHC LTD, NORTH CIRCLE.
O/o the Superintending Engineer/North Circle No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006.
Construction of New Building for Model Fire and Rescue Services Station at Coimbatore in Coimbatore District.
2020_TNPHC_180673_1
SE/NC/DB/1025/2020
Open Tender
Civil Works
Lump-sum
300 days
Coimbatore in Coimbatore District
Refer tender documents
8 documents required · 8 mandatory
₹0
₹1.5 L
28 Dec 2020
22 Sept 2020
8 Oct 2020
22 Sept 2020
6 Oct 2020
22 Sept 2020
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
25 : M.S.Holdfast
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
55.2 : Supplying and fixing of approved brand Porcelain Flat Back urinal
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
77.3 : S&F of TV/Telephone line Socket
77.4 : S&F of 20mm dia PVC pipe for TV/Telephone line
78 : Earthing Station IS3043 (Type I)
81 : Meter Cupboard
86 : Anti termite treatment
ANNEXURE 2.1.1 : Supplying and filling with Gravel
2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
c) In First Floor.
d) In Second Floor.
e) In Third Floor.
f) In Fourth Floor.
9.2.1 : Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand) a. In Ground Floor/Stilt floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) (using crushed stone sand) b. In Ground Floor
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
11.2.1 : Brick Partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) (using crushed stone sand) a. In Ground floor
b. In First Floor
c. In Second Floor
12.1.1 : Brick partition work in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
15.1.1 : Cuddappa slab 20mm tk. For C/B slab. a. In Ground floor
b. In First floor
c. In Second Floor
d. In Third Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
g.Double centering
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.5.2.1: Supplying and fixing of solid core flush door shutter of Tk 35mm a) Door size 1.80m x 2.10m (Double Leaf)
b) Door size 1.50m x 2.10m (Double Leaf)
c) Door size 1.20m x 2.10m (Double Leaf)
21.5.5.1 : Supply and fixing Solid core flush door shutter of thickness 35mm a) Door size 1.00m x 2.10m (Single Leaf)
b) Door size 0.90m x 2.10m (Single Leaf)
c) Door size 0.75m x 2.10m (Single Leaf)
22.3.3 : TW frame & TW styles & rails with BWR double leaf shutters for cup board/ wardrobes including one coat primer & two coats enamel paint.
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand)
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles (antiskid) using Grout (Tile Joint Filler) (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand)
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand)
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.3.1 : Supply and planting avenue trees (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5.2 : Wash Hand Basin of size 550 x 400 mm
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
56.4.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F.(using crushed stone sand)
57.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1 : Gully Trap using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
71.2 : Supplying and fixing of 32 AMPS Triple pole main switch.
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.1.1 : 1 Nos of 32Amps - Fuse unit
79.2.1 : Supplying and fixing of 3 Nos of 32Amps - Fuse unit
80.1 : Supplying and fixing of 450 x 375 x 20mm thick TW plank
87.1 : Supplying and delivery of Three phase ELCB/RCCB
90.1 : Providing additional strutting to centering of plain surface.
98.3.2 : TW panelled door shutter (with brass fittings) a. 1800 x 2100mm. (Double leaf)
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361 : Concrete Designer Tiles flooring (using crushed stone sand)
361.5.1: Vitrified Tiles flooring (ivory) (using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
799 : Two coat of OBD over one coat white cement for inner walls
ANNEXURE II A1) Supplying & fixing in position of UPVC Ventilator Louvered type for all sizes
A2) Supplying & fixing in position of UPVC window of casement type (open) for all sizes
A3) Supplying and fixing of 9 Watts LED bulbs
A4) Supplying and fixing of 4' long 18 Watts LED tube light
A5) : Supplying and fixing of water tight Bulk head fittings suitable for 12W bulb.
A6)Supplying and fixing of 25" LED street light with fittings
A7) Supplying and fixing of 12 Watts LED bulbs
Johnsun Engineering Contractors
SHREE BALAJI ENTERPRISES
chendur construction company
J C ENGINEERING CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .