| 1 | L1₹14.8 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹17.6 L+₹2.8 L (19.1%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L2 | Rejected-Finance Not being Lowest | |
| 3 | Rejected-Technical CHENNAI | CHENNAI | TAMIL NADU | 600001 | - | Rejected-Technical Not Validated |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
13 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE WELLINGTON
Headquarters, Commander Works Engineers, Wellington, Barraks-Post, The Nilgiris, PIN 643231
PROVN OF POWER SUPPLY 100 KVA AND POWER SUPPLY CABLE UPTO 100 KVA INPUT AT WELLINGTON COMPOSITE NFS NODE UNDER GE DSSC WELLINGTON.
2020_MES_352711_1
84694/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
WELLINGTON
E Class b ii Category
6 documents required · 6 mandatory
₹500
GE DSSC WELLINGTON
₹28,000
Yes
25 Jul 2020
13 Jun 2020
15 Jul 2020
13 Jun 2020
13 Jul 2020
29 Jun 2020
15 Jun 2020 - 20 Jun 2020
60 days
Amount
Supply, install, testing & commissioning of transformer platform/plinth mounted of capacity 100 KVA step down, BEE 5 Star Rated (Energy Efficiency Level 3), outdoor type 11.0/0.433 KV, 50 Hz, AC double wound core type, copper wound, oil immersed type, naturally air cooled with external cooling tubes, transformer delta connection on HT side & star connection on LV side in accordance with vector symbol DyN 11 (vector group - 4) with off-load tap changer on HT side to vary secondary voltage +/- 7.5% in equal steps of 2.5% as per IS – 1180 (Part-I) - 2014. The voltage regulation shall be as per IS including first fill of transformer oil up to appropriate level all as per IS-335 all as specified & as directed comprising with & including the following specifications :- (a) 01 No cable end box on HT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of HT 11000 V grade XLPE insulated heavy duty cables including glands complete. (b) 01 No cable end box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of LT 1100 V grade XLPE insulated heavy duty cables including glands complete.
(c) Oil conservator with filter type drain valve & oil level gauge. (d) Explosion vent with double diaphragm & sight glass. (e) Thermometer pocket. (f) Two earthing terminal on tank body to facilitate fixing of 32 x 6 mm GI strip etc. (g) 01 No thermometer dial type, vapour pressure type having range 0 to 120'C with max temperature indicator, re-setting device & marked max temp reading point. (h) Rating plate with terminal marking plate. (j) Oil level gauge. (k) Oil drain filter valve. (l) Oil filling port on top cover with plug. (m) Air release valve / plug. (n) 04 Nos plain solid cast steel detachable rollers. (o) First fill of transformer oil confirming to relevant IS & tested up to 60 KV dielectric strength. (p) Inspection cover. (q) Lifting lugs & jack lifting pad & support. (r) Silica gel breather without / with connecting pipes, first fill of dehydrating agent. (s) Cover lifting eyes. (t) Oil temperature indicator of approved range, including shut off valve between conservator & main tank. (u) Additional / Extra bushing for neutral outside of LV side
NOTE:- 1) Design / drawing / BOM of the Transformer showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer. 2) Quoted rate is deemed to be inclusive of Factory Inspection/Testing of the Transformer before dispatch by an E/M Officer nominated by the Accepting Officer. 3) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 4) Purchase Vouchers & Manufacturer’s Test Certificates in Original to be submitted to the Engr-In-Charge.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead Copper strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. NOTES FOR ITEM NO 2 & 3 ABOVE:- On completion of the complete work/job the Contractor is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade including complete internal wiring with not less than 2.5 sqmm copper wire including cable glands of suitable sizes including suitable PCC (1:3:6) type C-2 foundation, necessary earthwork (if any) complete all as specified & as directed with & including the following accessories: (100 KVA TR) BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos high grade Aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY: The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING: (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 125 to 160 A - 01 Nos. Cat No : CM92108OOM1OG of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, 4P - 01 Nos. Cat No : CO22000OOOA, Type CO2-200 of make L&T or techno-commercially equivalent of ABB/SIEMENS. OUTGOINGS: (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 125 to 160 A - 02 Nos (1W +1S). Cat No : CM92108OOM1OG of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-55, 11.0 meter long inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces complete all as specified and directed. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. Make : JINDAL/TATA/NATIONAL TUBING COY/CHENNAI POLES/BOMBAY TUBING. NOTE: 1) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 2) Design / drawing of HT Poles showing the layout & dimensions is to be obtained from OEM/Auth dealer/supplier & the same is to be got approved from Engr-In-Charge & GE before placing final order to the manufacturer.
M&L for cross arms bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces complete
M&L for anti-climbing devices, comprising of 2.24 mm dia galvanised steel 2-strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles, to a length of 0.5 mtr to 1.0 mtr clamped & properly secured or as specified & as directed (clamps measured separately) complete all as specified and as directed.
M&L for Pin type porcelain, vitreous, white, brown or green insulators including one GI spindle, two galvanized iron washers and one galvanized iron nut, 150 mm dia & 150 mm height suitable for working pressure 11 KV complete all as specified and as directed by Engr-in-charge. Make : BHEL/PACTIL/JAIPURIA BROTHERS or techno-commercially equivalent.
Supply, install, testing & commissioning of gang operated device (GOD), triple pole, current rating 400 Amps, HT 11 KV vertical, mechanically operated mounted on insulators and steel frame with operating mechanism operated from ground with and including jumper connections with suitable size & type ACSR conductor along with PVC pipe covering with colour code between main supply and GOD complete all as specified and as directed. Make : BHEL/PACTIL/JAIPURIA BROTHERS or techno-commercially equivalent.
M&L for swing out expulsion fuse single pole (Drop Out Fuse) with fuse carrier, fuse element mounted on insulator & fitted on steel frame etc for 11000 volts of capacity 25 amps complete all as specified and as directed complete. Make : BHEL/PACTIL/JAIPURIA BROTHERS or techno-commercially equivalent.
M&L for lightening arrester non-linear resistor type confirming to IS-3070 (Part-III) - 1993 complete, line discharge class-3, nominal discharge current 10 KA (peak), 12 KV rated system voltage peak value high current impulse of 4/10 micro sec, wave shape 100 KA (peak) assembly suitable for 11 KV, long duration discharge class - II with insulation level 28/75 KV & mounted on hot dip galvanized steel structure including all clamps, nuts, bolts & washers & connecting to earth complete on pole structure all as specified and directed. Make : BHEL/PACTIL/JAIPURIA BROTHERS or techno-commercially equivalent. NOTE FOR ITEM NO - 8 TO 11 : Channels, cross-arms, bracings, nuts, bolts, washers etc. shall be measured & paid separately under relevant items of work.
S&F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 complete all as specified and directed.
M&L for PCC 1:4:8, Type D-2 using 40mm graded stone aggregate for transformer platform / plinth etc. and finishing the surface even and smooth without using extra cement including necessary formwork complete all as specified as directed.
M&L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in foundation, filling mass concrete, for pole foundation and finishing the surface even and smooth without using extra cement including necessary formwork complete all as specified and directed.
M&L for PCC 1:2:4, Type B-1, using 20mm graded stone aggregate for coping of poles etc, and finishing the surface even and smooth without using extra cement including necessary formwork complete all as specified and directed.
Supply, laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade (Earthed), of size 95 sqmm, 3 core with FRLS PVC outer sheath in trenches / through GI pipe / fixed along with pole structure etc complete all as specified & as directed. Make : HAVELLS/GLOSTER/POLYCAB or techno-commercially equivalent. NOTE : Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified and directed. Make : HAVELLS/GLOSTER/POLYCAB or techno-commercially equivalent. NOTE: Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and directed. Make : DENSON/MSEAL/3M or techno-commercially equivalent.
M&L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH or techno-commercially equivalent.
M&L for aluminium conductor steel reinforced (ACSR) for jumpering etc. complete all as specified and directed.
M&L for RCC cable route indicator of size 50 cm x 15 cm x 5 cm in CC 1:2:4, type B1, using 20 mm graded stone aggregate including reinforcement of 8 mm dia steel both ways @ 100 mm c/c duly embossed/written MES HT Cable & Size mounted on, including PCC 1:3:6, type C2 below 20 cm ground level including necessary excavation & earth work complete all as specified and directed. NOTE: The spacing between two consecutive cable route indicators shall not be more than 50.0 meters & also shall be provided at each & every bend or corner.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe and getting out in hard dense soil complete all as specified and as directed.
All as per item No 22 here in before but exceeding 1.5m & not exceeding 3.0 m in depth complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for providing sand cushioning for protection of UG cable in trenches with dry ( coarse ) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and directed.
Supply and laying sub class "B" bricks in trenches for protection of UG Cable complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 x 180 x 40 mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified and directed. Make: Mehtab/Lucky Cement Block Works/Sukhi Enterprises or techno-commercially equivalent.
M&L for chain link fencing including line wires, any size/type of standard rails/angles, straining bolts etc. including provn of binding wires complete all as specified and directed.
M&L for MS angle iron post & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets for securing wire mesh conforming to Fe-290 E-165 including painting with one coat of red oxide primer & two coats of aluminium paint complete all as specified and directed.
M&L for M-Sand filling, levelling, watering & consolidation in 15 cm layers on the level ground surface in Sub-Stations complete all as specified and directed.
M&L for spreading & leveling stone aggregate of size 20 to 25 mm on sand filling in the Sub-Stations complete all as specified and directed.
rvelectricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .