Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC H NO 256 PRADEEP VIHAR IBRAHIMPUR NATHU PURA DELHI 110036 | DELHI | NORTH DELHI | DELHI | 110036 | ₹8.3 L | L1 | Accepted-AOC Being L-1 |
| 2 | L2₹9.2 LRejected-Finance H NO 703 BLOCK B2 ST NO 27 HARSH VIHAR DELHI 110083 | DELHI | NORTH WEST DELHI | DELHI | 110083 | ₹9.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹10.0 LRejected-Finance 91 ENGINEERS ENCLAVE 1ST FLOOR PITAMPURA DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹10.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹10.2 LRejected-Finance C4 F 119 JANAKPURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | ₹10.2 L | L4 | Rejected-Finance L4 |
| 5 | L5₹10.7 LRejected-Finance | ₹10.7 L | L5 | Rejected-Finance L5 |
Tender Value
₹14.6 L
EMD Value
₹30,000
Closing Date
20 Feb 2026, 11:00 amClosed
DDH/WZ
OFFICE OF DY. DIRECTOR HORTICULTURE 4TH FLOOR, DR. SAHIB SINGH VERMA NIGAM BHAWAN NEAR SHIVAJI COLLEGE, SHIVAJI PLACE, RAJA GARDEN, NEW DELHI - 110027
Development of Park J-Block, Central Vikas Puri, Ward No. 103, West Zone
2026_MCD_267145_1
DDH/WZ/MCD/2025-26/653/ NIT No. 2
Open Tender
Miscellaneous Works
Percentage
15 days
Park J-Block, Central Vikas Puri
PLS REFER TENDER DOC
2 documents required · 2 mandatory
₹590
₹30,000
22 May 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
Development of Park J-Block, Central Vikas Puri, Ward No. 103, West Zone.
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Rough dressing the trenched ground including breaking clods.
Fine dressing of the ground.
Plumeria alba dwarf height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bag
Foxtail palm well developed with fresh & healthy foliage of ht. plant 210 cm to 240 cm in 40 cm Cement Pot/ Plastic pot.
Ficus Retusa Topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 cm to 210 cm ht in 40 cm Cement Pot/ Plastic pot.
Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 cm to 75 cm ht in 30 cm Earthen Pot/ Plastic pot.
Hamelia patens of height 30-45 cm. with 3-4 branches in poly bag of size 20 cm
Nyctanthes arbor-tristis(Har singar) of ht. 90-105 cm in Earthen pot of size 20 cm
Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pot of size 20 cm
Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot
Clerodendrum inerme of ht. 12 cm to 15 cm multi branched in Poly Bag.
Wadelia trilobata,full of leaves in 15 cm size of Earthen Pot /Plastic Pot.
Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size15 cm.
Alternanthera species of height 10 cm to 12 cm, full of branches and foliage in Poly Bag.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm dia, and 60 cm deep
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Shrubs Plant
15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 18.9.5 40 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 18.17.3 40 mm nominal bore
C.P. Brass union 40mm dia
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 18.41.5 40 mm diameter pipe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
DOC.pdf
Tender Documents • 0.38 MB
BOQ_310636.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].