Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC MAHALDANGA P O MOLIAN DIST BANKURA PIN 722136 | BANKURA | BANKURA | WEST BENGAL | 722136 | L1 | Accepted-AOC AOC | |
| 2 | L2₹4.4 L+₹814 (0.18%)Rejected-Finance HETIA BANKURA | BANKURA | BANKURA | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹4.4 L+₹2,207 (0.50%)Rejected-Finance MANKHAMAR P S ONDA BANKURA PIN 722144 | BANKURA | BANKURA | WEST BENGAL | 722144 | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹8,858
Closing Date
8 Dec 2023, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Various work in the nature of regular Operation, Repair and Maintenance on the basis of vetted estimate from PWD (Civil), PWD (Electrical ), and PHE (Civil) at Bankura Sammilani Medical College and Hospital in Bankura District for the Super Specialit
2023_WBPWD_609487_1
WBPWDTE/ AE /BMCESD /NIQ-19/Q of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/PWD/Bankura
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,858
Yes
1 Sept 2025
29 Nov 2023
11 Dec 2023
29 Nov 2023
8 Dec 2023
29 Nov 2023
Amount
Supply delivery of 7.5 Mtr Steel Tubular Pole (Zindal /Bansal/Utkarsh) as per specification (IS 2713, Pt. II 1980) of 410-SP-9 ; 7.5mtrs: 110Kg & having diamention as per details given bellow: Out side dia & thickness of the Bottom section (139.7 x 4.50) mm; Middle ( 114.3 x 3.65) mm, Top Section (88.9 x 3.25 ) mm with fixing the base plate , necessary drill hole ete as per direction of EIC.
Erection of Single 7.5 mtr Single Steel tubular pole with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary Without Loop Box.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (40 mm dia)
Painting of Steel Tubular Pole of 9 mtr length and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint upto 9 mtr. long pole i)1st coat of synthetic paint over 1 coat of RO priming, II)2nd coat of synthetic paint over 1st coat
Painting of single Steel arm bracket of 1.5 mtr lengths and no. of coats of paint, with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.1st coat of aluminium paint over 1 coat of RO priming.
Part-B [ Earthng] Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Part-C [ Fitting & Fixing] Supply and Delivery of 230V,50Hz, 90 Watt LED outdoor type street light with IP-65 /66 and Surge protection device upto 12Kv in built ( Similar to Crompton make Cat no CRP-404-90-57-SL-GL-NSG or similar make compatibale to this). Make :- Phillips/ / Havells / Bajaj or any reputed brand recognised by EIC.
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from pole
Supply & Fixing of 50 mm. dia 1.5 mtr. long detachable type G.I. (ISI-Medium) Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer, with GI socket etc incl. painting to complete the installation as per direction of EIC.
Supply & Fixing of 50 mm. dia 1.5 mtr. long detachable type G.I. (ISI-Medium) Double arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer, with GI socket etc incl. painting to complete the installation as per direction of EIC.
Part-D [ Cable , Laying, Gland & Socketing] Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC 4 core 10 sqmm (for street light & Security light)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m above 150 mm. thick
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 16 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . 4 core 16 sqmm
Part-E [ Timer , Interconnection & Loop Box] Supplying and fixing Timer panel made of 16 way Distribution Board with transperent front door and din rail for mounting the following items included. per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer similar to ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) –1 no B) One no. ML-3 conctractor,(L&T make) with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T )– 1 no C) 4 pole 32 Amps MCB ( L & T / Ligrand )- 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( Make - Legrand /L&T) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC(for controlling AC Machine) (Make - Legrand /L & T / Crabtree)
Inter connection between Loop Box to fittings by 1.1 KV 2 x 1.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) through 20mm size PVC pipe incl. necy. fittings as required as per direction of EIC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC
MAGNET ELECTRIC WORKS
BISWAJIT CHOWDHURY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .