| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L1 | Accepted-Finance Quoting Lowest rate | |
| 2 | L2₹10.1 L+₹21,712 (2.20%)Rejected-Finance NARAYAN DIGHI PRIMARI SCHOOL RAYAN PURBA BURDWAN 713101 | PURBA BURDWAN | PURBA BURDWAN | WEST BENGAL | 713101 | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹12.4 L+₹2.5 L (25.2%)Rejected-Finance BOLGONA P O BURDWAN PURBA BARDHAMAN 713407 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713407 | L3 | Rejected-Finance Quoting Higher rate |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
25 Jun 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Yearly basis Repairing of Electrical Installation Work for various places with in the compound of Anamoy SSW Hospital Purba Bardhaman as and when required in the FY2023-2024 Budwan Medical College and Hospital Purba Bardhaman. (Project ID HF232414
2024_WBPWD_695185_1
WBPWD/SEWEC /BED /NIQ-21 /2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
365 days
Burdwan
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
Office of the Superintending Engineer, Western Ele
12 Jul 2024
18 Jun 2024
27 Jun 2024
18 Jun 2024
25 Jun 2024
20 Jun 2024
18 Jun 2024 - 19 Jun 2024
19 Jun 2024
Amount
DISTRIBUTION WIRING
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision mms make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
Average run 6 mtr
Average run 8 mtr
Average run 9 mtr
Average run 10 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI)partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 6 mtr
Average run 8 mtr
Average run 9 mtr
Average run 10 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]
Average run 8 mtr
Average run 9 mtr
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision mms make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
Average run 8 mtr
Average run 9 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal &mvertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 9 mtr
Average run 10 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]
Average run 8 mtr
Average run 9 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision mms make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish.
On Board
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision mms make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Make:Legrand Myrius/Anchor Roma/Crabtree) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.
On Board
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Finolex/Havells/polycab/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Distribution wiring in 1.1 kV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
20mm size
25mm size
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
25 mm dia 3 mm thick polythene pipe without earth continuity wire.
PLUG & SOCKET
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Make:Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator(Anchor) & 20A switch type SP MCB (Crabtree) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20 A plug socket (Anchor), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator (Anchor) & 20A switch type SP MCB (Crabtree) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 20A plug socket with separate 3 nos. 20A Piano key type switch, indicator (Anchor) & 20A switch type SP MCB (Crabtree) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator(Anchor) & 20A switch type SP MCB (Crabtree) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make:Legrand Myrius/Anchor Roma/Crabtree) & necy. Connections.
Supply & Fixing 240 V, 1 nos. 6A, & 1 no. 20A plug socket with separate 1 nos. 6 A & 1 no. 20A Piano key type switch, indicator (anchor) on sheet metal switch board embedded in wall incl. S & F 200 mm x 150 mm x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 25 A, Modular type starter (Make:Legrand Myrius/Anchor Roma/Crabtree) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing GI Modular Switch Board (Make:Legrand Myrius/Anchor Roma/Crabtree)of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
4 Module
6 Module
8 Module
12 Module
Supplying & Fixing GI Modular Switch Board (Make:Legrand Myrius/Anchor Roma/Crabtree)of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
2 Module
4 Module
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Computer Plug](Make:Legrand Myrius/Anchor Roma/Crabtree)
Supply & Fixing 240 V, 16A, 3 pin Modular type plug socket with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:Legrand Myrius/Anchor Roma/Crabtree) [Sep 16A Plug].
Supply & Fixing 240 V, 2 nos. 16 A, 6 pin Modular type plug socket with 2 nos. 16A Modular type switch without plug top on 8 Module GI Modular type switch board with 8 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:Legrand Myrius/Anchor Roma/Crabtree) [2x 16A plug]
S&F 240V, 2 nos. 6A, 5 pin Modular type plug socket with 2 nos. 6A Modular type switch with Indicator Modular type without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:Legrand Myrius/Anchor Roma/Crabtree) [2 x 6A Plug].
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch, 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:Legrand Myrius/Anchor Roma/Crabtree) [ 4x 16A plug]
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:Legrand Myrius/Anchor Roma/Crabtree)
S & Fixing of 240V, 90 watt, LED Street Light Fittings with IP 66 protection including 10 KV SPD with CCT ( 5000-6500) & Luminious efficacy >110 Lumen/ Watt. The LED luminaires and accessories shall have BEE Certification.( Make Philips/ Crompton/Wipro)
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable ben S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting.
Supplying & Delivery LED bulk head light fitting Pressure Die cast housing LED bulkhead with IP66 Protection and IK09 impact resistance suitable for surface and wall mounting applications. (Make - Philips /Crompton/ Wipro) on wall/ceiling by screws as per GS.
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary. without loop box.
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick) at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary
Without Loop Box
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 200 x 150 x 100mm
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
S & F of Single arm header assembly fabricated from 40 mm dia G.I.pipe (ISI-M) of 1.5 Mtr.long rigidly welded with 65 mm dia G.I. pipe (ISI-M) of 0.3 Mtr. Long at an angle of 15 degree with horizonrtal axis incl. S&F 3 nos. 1/2" MS jam nut each with 1 no. 1/2" dia. through bolt and painting the entire assembly.
Single arm header
Double arm header
Fixing of LED compound light in existing arm bracket of 9 mtr long pole inluding necessary connection.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Supplying & laying PVC 3 core 1.5 unarmoured industrial flexible copper cable with PVC round 'U' CLIP shaddle on wall & also proper socketting both end as per G.S. ( Make Gloster/ Havells/ RR/ Polycab/ KEI) [ from loop box to bulkhead light fittings, Poles & High mast light interconnection]
Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
SUPPLY OF CABLE
Supply & Delivery of XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes and conforming to IS: 7098(Part-I):1988. ( Make- Universal/ Polycab/ RR cable /Havells/ as per choice of EIC). Test certificate must be sumitted at the time of supply.
2 Core 6 sq mm
2 Core 10 sq mm
4 Core 10 sq mm
4 Core 16 sq mm
4 Core 35 sq mm
4 Core 50 sq mm
LAYING OF CABLE
Laying of one No. cable 4 core 10 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable 4 core 10 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
4 core 10 sqmm
Laying of cable 4 core 16 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
4 core 16 sqmm
Laying of cable 4 core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
4 core 35 sqmm
Laying of one No. cable 2 core 6 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable above 4 core70 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
4 core 70sqmm
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
2 core 6sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 16 sq mm
4 Core 10 sqmm
2 Core10 sqmm
2 core 6 sqmm
4 Core 35 sqmm
4 Core 50 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
4 Core 16 sq mm
4 Core 10 sqmm
2 Core10 sqmm
2 core 6 sqmm
4 Core 35 sqmm
4 Core 50 sqmm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector,6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support
200x50x1.25mm (18SWG)
VTPNDB, TPNDB & SPNDB
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
6 Way Enclosure ( Make Legrand/Schneider/L&T)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+12 Way Enclosure ( Make Legrand/Schneider/L&T)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS.
63 A FP ( Make Legrand/Schneider/L&T)
40 A DP ( Make Legrand/Schneider/L&T)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS.
6-32 A SP ( Make Legrand/Schneider/L&T)
6-32 A DP ( Make Legrand/Schneider/L&T)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment ( Make As per approved by EIC) (2way)
SUPPLY & FIXING OF FANS, LIGHTS etc.
Supply & Delivery of 4 feet Industrial box type single LED fitting including S & D of 1X18/20 wattt LED( Polycarbonate) with glare free light distribution with CCT (5000K-6500 K) , with minimum luminious efficacy >100 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification. Down cover of the fittings should be fixed by screw at both sides. ( Make Philips/ Crompton/ Wipro/ Bajaj)
Supply & Delivery of 4 feet Industrial box type Twin LED fitting including S & D of 2X18/20 wattt LED( Polycarbonate) with glare free light distribution with CCT (5000K-6500 K) , with minimum luminious efficacy >100 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification. Down cover of the fittings should be fixed by screw at both sides. ( Make Philips/ Crompton/ Wipro/ Bajaj)
Supply& Delivery of 240V 9 W LED lamp with CCT (5000K-6500 K) , with minimum luminious efficacy >100 lumen/watt or better. The LED Lamp and accessories shall have BEE Certification. ( Make Philips/ Crompton/ Wipro/ Bajaj)
Supply & Delivery 0.5 watt LED night lamp ( Make Philips)
Fixing only lamp
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
S & F fan down rod (14 SWG) incl. necessary connection wire (2X1.5sqmm cu wire) and painting the down rod with necessary hole for nuts and bolts as per direction of EIC
Supply & delivery of 230 V. 55 W., 1200 mm sweep, Brown coloured ceiling fan with complete accessories like blades, canopy, fork, rubber bush etc with all accessories without regulator having Double Ball Bearing & Low Noise following specifications - (Make -Usha Striker Plus / Orient Summer Breeze Pro/ eqv. model of Crompton Greaves) Capacitor - P2 type. Speed - 370 - 380 RPM. Air Delivery - 220 - 230 M3/min. Including safety wires for secondary suspension of fans. V2 grade ball bearing for whisper-quiet operation and durability.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing P2 type bust proof Fan capacitor 2.5/2.25 mfd rating ( Make Universal/Tibcon/ Equivalent)
S&F MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only Modular type fan regulator on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only fan regulator on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. Connections etc.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust for 23 cm (9").
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al 23 cm (9")
For Al 30 cm Exhaust fan (12")
MISCLLENEOUS
Supplying and fixing 240/415 V change over (MCB module) of on din rail of existing DBs/ enclosure and necessary connection.
40 A FP ( Make Legrand/Schneider/L&T)
20A DP ( Make Legrand/Schneider/L&T)
Supply & Fixing of Blank Plate for modular box as per G.S and also for requirement (Make;Legrand Myrius/Crabtree/Anchor Roma)
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 415V TPN with fuse on L&N 100/125 A( Make Legrand/Schneider/L&T)
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials
3½ / 4 core 10-16 sqmm cable
3½ / 4 core 25-35 sqmm cable
3½ / 4 core 50 sqmm cable
3½ / 4 core 120-150 sqmm cable
3½ / 4 core 185 sqmm cable
3½ / 4 core 300 sqmm cable
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
4 bars 415 V, 100/125A ( 4 x 15x3mm- Dimension of Cu Bars 85CM long] Dimension of Sheet Metal Box 500x150mm) ( Make PWD approved /as per dirction of EIC)
4 bars 415 V, 200A ( 4 x 20x5mm- Dimension of Cu Bars 85CM long] Dimension of Sheet Metal Box 500x150mm) ( Make PWD approved /as per dirction of EIC)
4 bars 415 V, 315A ( 4 x 40x5mm- Dimension of Cu Bars 85 CM long] Dimension of Sheet Metal Box 500x150mm) ( Make PWD approved /as per dirction of EIC)
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm x 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required.
100 mm x 100 mm x 65 mm
150 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
240 mm x 200 mm x 65 mm
Neat cement punning about 1.5 mm thick in wall, window, sillis, floor, drain etc.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
With 1:6 cement mortar 20 mm thick plaster
White washing including cleaning and smoothening surface thoroughly. One coat
EARTHING
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:[panel earthing +others earthing]
By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming (For Soft Soil) as per GS.
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
Solid GI wire No. 4 SWG
No. 6 SWG
No. 8 SWG
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Dismantling the existing E.I. work incl. existing defective, non functioning Panels, PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC and following existing fittings from its original position & storing properly incl handed over the same at Division Store as per direction of EIC after all no additional cost or no extra cost will be paid by the department after completion the installation
Submission of details SLD ( both hard & soft copy ) by AUTO CAD of the above job with indicating all the items of Power Distribution system with position of existing and also new cubical panel, feeder piller box, HT gear, Main LT panel , Sub-Station related wiring, VTPN's, PBDBs, LBDBs, Power Plugs, Lights, Fans, Switch Boards etc. as per direction of EIC
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop.
Painting upto 10 letters of the engraved number with approved black /red paint as required.
Painting of ceiling fan with one coat of primer and two coat of synthetic enamel paint by spray painting after cleaning and removing the old paint.
Extra for additional one letter incl. hifen, stroke and stop.
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint.
Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.
One coat of red lead/Zinc chromate priming
1st coat of synthetic enamel paint over the primer
2nd coat of synthetic enamel paint over the 1st coat
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
Upto 9.0 mtr. long pole
1st coat of aluminium paint over 1 coat of RO priming
2nd coat of aluminium paint over 1st coat
Painting Block Letters or Digits within a circle/square as required, with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below
a) Size 40 mm and upto 50 mm
b) Size 50 mm and upto 75 mm
Supply & Delivery 8 ft long mediun duty aluminium Step ladder with utility Tray & rubber gasket at 4 nos. legs as per direction of E.I.C. (Make -Liberti/ Alnico/ Pyramid/ Patel/Seasoned or Ripe or brand approved by EIC)
Supply & Delivery 12 ft long strong mediun duty aluminium Step ladder with utility Tray & rubber gasket at 4 legs & proper support arrangement as per direction of E.I.C. (Make - Liberti/ Alnico/ Pyramid/ Patel/Seasoned or Ripe or brand approved by EIC)
Washing the fan body, blades with jute soap water with Kerosene oil with co’s own tools & tackles and make ready for re-fixing the same position as per direction of E.I.C.
Opening the fans part by part cleaning the bearing by kerosin oil, cleaning, overhauling, greasing the fan and testing the fan to its proper speed as per direction of E.I.C.
Ceiling Fan
Exhaust Fan
Supply & Fixing of ball bearing in place of defective one as per specimen. (Make - SFC/NBC/TATA or brand approved by EIC) following
Supply and fixing of Gun matel bush bearing for Exhaust/Wall Fan/Stand Fan.(Make-GM)
Supply & Fixing washer guard with spring for the above bearings.
Supply & Fixing Bobbin Insulator for hanging the fans set with hold clamps, 2"X1/2"nuts, bolts etc.
Supply & Fixing of split pin
Supply & fixing of condenser clamp for placing the capacitor in place of damaged one.
Opening the motor part by part and rewinding the stator coiling by approved gauge, super enameled cu-wire, minalex paper, mica-sheet, ampere-tape, heat varnishing, making loops with S/F insulation sleeves etc.incl supplying looping PVC copper FR wire as required size after cutting out burnt coil refitting and testing the same as per direction of E.I.C.
a) Ceiling fan - 48”
b) Exhaust fan - 9"
c) Exhaust fan- 12''
d) Wall Mounted Fan- 20'' ( Metal Body)
Charges for welding, twining, cutting, polishing the fans shaft as per direction of EIC for requirement of the fan.
S & F new shaft in replace of damaged ceilings fan & cabin fan.
Cost of only heat varnishing the fan coils varnishing heating & loop changing of the fan coil by S & F new loof wire by PVC flex cu wire from stator coiland testing for ceiling fan, exhaust fan & wall fans.
Supply and Fixing Upper and Lower Canopy.
Supply and Fixing two way PVC Connector
Supply & Delivery of Ceiling Fan blade.
Carrying charges for the fans from work site to co’s workshop and back to site incl. labour charges of loading and unloading
Note:- All fans RPM test speed certificate & details materials, work done list for each Fan wise will must be given after completion of repairing & rewinding.
Supply & fixing additional safety arrangement of ceiling fan by stranded GI strain wire of suitable gauge with one end fixed at RC clamp with special type of socket, nut-bolts, thimbles which throughly crimped with the strain wire and the wire passing through down rod (for upto 8 ft or as per site condition) and also other end connected with armature spindle by its existing jam nut hole with special arrangement (sample approved by EIC & specification also). The length of the strain wire up to 9ft or as per site condition also considering any type of work required i.e. enlarging the existing hole by file etc. to complete the job including installation as per direction of EIC (Static & Dynamic Load Test (in rotation of 1:20) certificate must be provided with final bill jointly with concerned Junior Engineer, Assistant Engineer & authorised Electrical Supervisor of Agency). 3' to 8'
Supplying of special type FORK of fan of following size:- i) (80mm long X 30mm wide) made of 12 SWG MS sheet with nickle plating - 2 nos ii) making holes of 8mm dia on MS sheet - 2 nos iii) supply of 8 mm dia 60 mm long bolt- 1 no iv) supply of 8 mm dia 45 mm long bolt- 1 no v) 8 mm dia nut- 2 nos vi) spring washer- 2 nos vii) making 3mm dia hole on each bolt - 2 nos viii) making 3mm dia hole on MS sheet incl. making threasd - 1 no ix) supply of split pin - 2 nos x) supply of 7 mm long brass screw with brass washer - 1 no xi) Rubber insulator (35mm dia)- 1 no.
Supply and fixing nuts and bolts having size of 6mm dia 35 mm long having necessary hole for split pin,with 1no split pin,1no spring washer and 2no flat washers for fixing the fan with down rod
Supply and Delivery of Digital Clamp Meter (Make - Fluke 302+) AC Current Range: 400.0 A; Accuracy: 1.8% ±5; AC voltage Range: 400/600; Accuracy: 1.5% ±5, DC voltage Range: 400/600; Accuracy: 1.5% ±5; Resistance Range: 4000 Ω; Accuracy: 1% ±5, Continuity: ≤ 70 Ω; Safety ratingCAT III 600 V;Temperature: 0 to 40 °C; Screen refresh rate: > 2 times / sec; Battery: 2 AA batteries. Warranty- 1 year from the date of work completion.
NB:- Above work only be done in case of urgency & based on requisition from Authority.
ANANTA ELECTRICAL ENGG CONSTRUCTION
D.D ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .