Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.0 L+₹5.6 L (16.3%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹41.1 L+₹6.8 L (19.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹41.7 L+₹7.3 L (21.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | R N AGRAWAL L4 | M/s RCC L1 | B S ENTERPRISES L3 | BHARDWAJ CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. | 2,727 | Sqm | 8 ₹21,816 Lowest | 8 ₹21,816 Lowest | 18 ₹49,086 | 20 ₹54,540 |
| 2.00 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. | 9 | Cum | 175 ₹1,575 | 100 ₹900 Lowest | 100 ₹900 Lowest | 150 ₹1,350 |
| 3.00 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. | 11 | Ten Sqm | 100 ₹1,100 Lowest | 100 ₹1,100 Lowest | 100 ₹1,100 Lowest | 200 ₹2,200 |
| 4.00 | Dismantling brick/concrete tiles any size etc including existing roof treatment of any thickness complete all as specified and directed | 34 | Ten Sqm | 250 ₹8,500 | 100 ₹3,400 Lowest | 200 ₹6,800 | 170 ₹5,780 |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. | 277 | Sqm | 15 ₹4,155 | 8 ₹2,216 Lowest | 12 ₹3,324 | 25 ₹6,925 |
| 6.00 | Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed. | 54 | Each | 30 ₹1,620 Lowest | 80 ₹4,320 | 100 ₹5,400 | 60 ₹3,240 |
| 7.00 | Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed. | 72 | Each | 60 ₹4,320 Lowest | 80 ₹5,760 | 100 ₹7,200 | 70 ₹5,040 |
| 8.00 | Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and as directed by Engineer-in-charge. | 6 | Per Leaf | 25 ₹150 Lowest | 90 ₹540 | 100 ₹600 | 50 ₹300 |
| 9.00 | Demolition of cement (un-reinforced) concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge. | 12 | Cum | 175 ₹2,100 | 150 ₹1,800 Lowest | 200 ₹2,400 | 150 ₹1,800 Lowest |
| 10.00 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge. | 1 | Cum | 175 ₹175 | 100 ₹100 Lowest | 200 ₹200 | 400 ₹400 |
Tender Value
₹48.7 L
EMD Value
₹97,394
Closing Date
15 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) MATHURA
GE (WEST) MATHURA
SPECIAL REPAIR TO 06 OR MD ACCN IN BLDG NO P-156/07 TO P-156/12 IN NEW RATC LINES UNDER GE (W) MATHURA
2025_MES_742355_1
8300/1349/E8
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) MATHURA
AS PER NIT
10 documents required · 10 mandatory
₹500
GE (WEST) MATHURA
₹97,394
Yes
3 Feb 2026
1 Dec 2025
22 Dec 2025
1 Dec 2025
15 Dec 2025
8 Dec 2025
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Dismantling brick/concrete tiles any size etc including existing roof treatment of any thickness complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed.
Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed.
Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and as directed by Engineer-in-charge.
Demolition of cement (un-reinforced) concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
Excavation in trenches in soft/loose soil not exc. 1.5 M wide and not exc. 1.5 M deep and getting out including forming bottom to required level or slope for laying of cable, pipe and concrete bed or for manhole etc not exc. 10 Sqm on plan all as specified and directed by Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed.
Removing surplus soil to a distance exc 250m but n.exc. 500m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed.
M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exceeding 10cm wide but not exceeding 20cm wide, surface flat for rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
S&F mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan to any radius half brick thick wall built in CM (1: 6) complete all as specified and directed.
S&F Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
S&F Pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block or filling of chowkhats including necessary form work complete all as specified and directed.
M&L 35mm thick factory made glazed and skeleton shutters of 2nd class HW with partially panel shutter open rebated and prepared to receive glass / gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR Part-1 section 8.24 (a) complete all as specified and directed.
M&L for 35 mm thick flush shutter with solid core construction with block board core and plywood face panels , commercial type on both sides members of shutters, covered decorative on both face veneer with liping/frame to match as specified in SSR Part I, section 8, clause 8.24 (a); supplied & fitted to Chowkats complete all as specified and directed by Eng-in-charge.
S&F powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium alloye sections sliding windows with frames series B (18mm), 3 track sliding shutters duly fitted with neoprene beading, glazing clips two shutters tinted glass panes 4.80mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm, aluminium alloy handles etc. complete all as specified and directed. Note : The rates include the cost of glazing, aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangement, handle with or without opening for AC/coolers as directed by Engineer-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws including locking arrengment complete all as specified and directed.
S&F powder coated Anodised aluminium window and ventilator shutters side hung type with sash, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws Anodise aluminium fitting such as peg stays 150 mm long (1 No ), including pag stay and hinges type B-21 100 mm long (2 No) and suitable handle (1 No) complete all as specified and directed.
S&F 4.80mm thick sheet glass in glazing to aluminium door, window & partition including pad panes complete all as specified and directed by Engineer-in-Charge .
S&F 5 mm thick figured (frosted) glass, ordinary quality glazing to aluminium door, window & partition including pad, gasket complete all as specified and directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with particle board core and 2,4 or 6 raised panel design with 5mm thick Moulded PVC Sheet on the front Face & 5mm Plain colour PVC sheet on back face, fixing in frame at site complete specification & drawing as per SSR complete all as specified and directed.
S&F 150mm stainless steel barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm long stainless steel handles, cast type complete all as specified and directed.
S&F 300mm stainless steel sliding door bolts, bolt type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F 100mm stainless steel hasp and staple, safety type with mild steel hinge pin including bolt to hinge plate (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F in repairs, vitreous China wash hand basin, white, flat back size 550 x 400mm including 15mm dia, 450 mm long HDPE PVC connection, 750 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed.
S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F 100mm size stainless steel hinges complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
S & F rotational moulded polyethylene water storage tank 750 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with all necessary GI fittings complete all as specified in SSR Pt I including taking down old unserviceable water tank & ball valve complete all as specified and directed by Eng-in-charge.
S&F 20mm dia PTMT ball PVC valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair 20mm gun metal gate valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed.
M&L for PCC type C1 1:3:6 (20 mm grade aggregate) as in platform for PVC tank complete all as specified & directed.
S&F 20mm GI nipple suitable for HDPE water tank complete all as specified and directed.
S&F in repair low density poly ethylene pipes (LDPE) of 32mm bore fixed complete to urinal pots all as specified.
M&L for cutting chases, pining in, making good to facing where required and pointed in CM (1:3) for concealed steel water tubing & like and making good, match with existing surfaces by applying white wash/colour wash cutting not exc 10cm girth complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
All as per item No 53.00 (here-in-before) above but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate) as in floor finishes and leveling course complete all as specified and directed.
M&L for 50 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed.
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) as per manufacturer’s instructions, finished fair & even, complete, all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in CM (1:4) as on ceiling complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge.
M&L for rendering dubbing coat over irregular surfaces of chajjas roof projections / ceiling / facia etc average 15mm thick in CM (1:4) over cement slurry coat @ 3Kg/Sqm making the surface even followed by 5mm thick rendering in CM (1:3) furnished even & smooth including making of drip course as required complete including roughening surface of old concrete by picking sweeping clean and washing with water complete all as specified and directed. Note : Rate for form work if required to be included in the quoted rate by the contrator.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces finished fair and even in CM (1:4) mixed with liquid water proofing compound complete all as specified and directed. Note:- Liquid WPC shall be measured and paid saperately.
M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :- (a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer a@ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed. (b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed.
S&F precast hydraulically pressed PCC tiles of size 25cm x 25cm x 20mm thick laid over and including screed bed 15mm thick in CM (1:4) set and jointed in neat cement slurry and pointed in CM (1:3) mixed with WPC of approved make in screed bed and pointing on roof complete height upto G+2 story bldg all as specified and directed.
M&L for applying a coat of two component elastomeric acrylic polymer modified cementitious water proofing coating, having properties of 80 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and sprinkle sand at 10-15 gram per sqft for better grip with plaster complete all as specified and directed.
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
S&F GI spout pipe 50 mm dia tubes,light grade galvanised, with all fitting, laid in treanches complete all as specified and as directed.
S&F in repair 15mm bore CP angle valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm bore bib tap, long body, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F in repair wall mixer CP brass cromium plated hot and cold with or without telephonic shower arrangement 15 mm bore complete all as specified and directed.
S&Fin repairs Sink mixer with swinging spout(wall mounted model) Chromium plated brass with connection and nut arrangement for for 15mm bore complete all as specified and directed by Engr-in-charge.
S&F in repairs 15mm bore brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, overall size 915mm x 460 mm / (36" x 18") bowl size 410mm x 355mm / (16" x 14") and depth 175mm / (7") including waste pipe of polythelene of low or high density or PVC 32mm dia & waste fitting brass chromium plated 32mm bore with long screwed shanks and fly nuts including making holes in brick walls for brackets and fixed in CM (1:3) or PCC 1:2:4 type B0 complete all as specified and directed by Engineer-in-charge. Make :- Nirali model Elegance (Glossy) / Prayag model No 1128-D Gold Series (Gloss) / Silver Shine (Bluestar sanitary industries Pvt Ltd) model No SSSB-52 (Glossy) or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- Size of sink for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide sink as per cat No mentioned against make of sink. where cat No is not mentioned against any make, in that case sink of size mentioned in description has to provide, if exact size of sink is not available, then next higher size sink has to be provided. Nothing extra shall be paid on this account.
S&F in repair vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge.
S&F in repair 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
S&F in repair 32mm Waste fittings, brass, chromium plated for glazed ware wash hand basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
S&F in repair 40mm Waste fittings, brass, chromium plated for sink, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
S&F in repair chromium plated shower rose with or without swivel joints including fixing to steel pipe of 125 mm size complete all as specified and directed.
S&F in repair for swiveling shower 15 mm with shower arm 195 mm long of CP of any colour and fixed complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel surfaces of any description or girth over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for bands, straps, supports or stays for rainwater , Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and lintle hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete including taking down old unserviceable PVC pipe with fittings complete all as specified and directed.
S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints laid in trenches complete including taking down old unserviceable PVC pipe with fittings complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and as directed.
S&F in repair PVC mirror cabinet size 350X450mm of standard size fixed to wall with PVC sleeves and steel screws complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for complete removal of existing treatment and preparartion of old surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old treated surfaces of ceiling and applying two coat of white wash complete all as specified and directed.
M&L for Plain cement concrete type B1 (1:2:4), using 20 mm graded crushed stone aggregate, 75 mm thick, as in floor and finished even and smooth using extra cement laid in alternate bay complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 20mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including cement plaster 15 mm thick in CM (1:3) laid and jointed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed.
S&F in repair brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F in repairs curtain rod, stainless steel of 25mm dia with fixing brackets stop rollers etc fix complete all as specified and directed.
S&F 300mm mild steel (Helical door spring) ordinary rat tail rod pattrern spring including roller and roller plate complete with necessary welding work complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channels or drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick (measured solid) precast cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) louvers and jallies, including all mouldings but excluding frame, set in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 18 MM thick PVC Celuka board of plain white color both side fixed with screws, solvent cement/ adhesive to make kitchen cabinet/cupboard sides, top and bottom and shelves inside the cabinets, cupboard shutters/frames (Density- 575 to 600 Kg/ CBM),complete, all as directed by Engineer-in-Charge.
S&F in replacemen 18 MM thick PVC Celuka board of single side prelam / rigidlam color fixed with screws, solvent cement/adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinet, cupboard shutters/frames, (Density- 575 to 600 Kg/ CBM), complete, all as directed by Engineer-in-Charge.
S&F Auto closing hinges 35 MM of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 digree for kitchen cabinet shutters, as per sample approved by the GE.
S&F continous piano hinges mild steel bright finish or electrogalvanised of 30mm width complete all as specified and directed.
S&F stainless steel handles 100 mm size for kitchen cabinet shutters / cupboard complete all as specified and directed.
S&F magnetic catcher of size 20mmx50mm suitable for kitchen cabinet shutters/ cupboard, complete all as specified and directed.
S&F ball bearing runners 45mm telescopic (KTS-20) full extension load capacity 50 Kgs complete all as specified and directed.
S&F in repair stainless steel plate rack of size 750mm x 600mm x 254mm made out of 0.63mm thick stainless steel of first quality complete all as specified and directed by Engineer-in-Charge. Make :- Nirali model Elegance (Glossy) / Prayag Gold Series (Gloss) / Silver Shine (Bluestar sanitary industries Pvt Ltd).
S&F in repairs PVC floor trap 100mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed.
S&F in repairs PVC nahani trap 100mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed.
S&F in repairs chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge.
M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed:- (i) Cleaning the sunken/lowered portion of \ RCC slab surface (incl vertical total depth plus skirting height) of floors by wire brush,chisel out any mortar sticking to the surface and brooming completely. Provn of 40 mm thick avg PCC 1:2:4 type B-O using 12.5mm graded aggregate as in padding concrete to achieve proper slope incl cutting holes in bricks or RCC wall for sprout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and incl integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed incl filling it with water to check dampness and seepage and where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out. Cont/-
Cont/- (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall besealed with epoxy puttySikaguard 694 F(I) or equivalent make in Fosroc/Thermax as approved by GE (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc/Thremax as approved by GE over base coat as per manufacturer's instruction to bottom and vertical sides upto finished floor level +100 mm height. The thickness of two layers shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vetical and bottom surface of the sunken portion. Cont/-
Cont/- (vi) Plaster the bottom surface and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with and incl integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc/Thermax as approved by GE @ 0.2% by wt of cement consumed as per manufacturer's specification incl rounding of corners and injuctions sloping towards spout. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint.
M&L for applying two coats of oil bound distemper using mechanised Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer as mentioned in Particular Specifications and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface over a coat of acrylic water based interior grade primer @ 0.9 ltr (undiluted)/10 sqmtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application having an electric motor of min. Cont/-
Cont/- 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats incl applying waterproof cement based putty @ 1 Kg (undiluted) per sq mtr. of average thickness 1 mm, of approved makes over the plastered wall after scrapping to prepare the surface even and smooth complete and. Sanding of the putty surface with Wall Sander machine (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above having dia of 7"/9" to make the surface free from dust etc. by skilled labour complete all as specified and directed. Cont/-
Cont/- Steps for application of putty:- Step 1) Mix the putty powder by adding 40-50% water and mix it with approved Putty Mixer (Putty mixer with min 1400 W power having mixer rod of industrial steel grade 45 with the mixing capacity of min 2.5 kg putty per minute) Step 2) Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of mechanised Spray Machine with max 6 ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041" Step 3) Allow 6-8 hrs time to dry the putty surface Note: - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application). complete all as specified and directed.
M&L for Complete removal of existing treatment on wall/ roof projections including facia,cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust,loose paint etc by skilled labour and applying two coats of oil bound distemper using mechanised Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer as mentioned in Particular Cont/-
Cont/- Specifications and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface over a coat of acrylic water based interior grade primer @ 0.9 ltr (undiluted)/10 sqmtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application having an electric motor of min. 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats incl applying waterproof cement based putty @ 1 Kg (undiluted) per sq mtr. of average thickness 1 mm, of approved makes over the plastered wall after scrapping to prepare the surface even and smooth complete and. Cont/-
Cont/- Sanding of the putty surface with Wall Sander machine (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above having dia of 7"/9" to make the surface free from dust etc. by skilled labour complete all as specified and directed. Steps for application of putty:- Step 1) Mix the putty powder by adding 40-50% water and mix it with approved Putty Mixer (Putty mixer with min 1400 W power having mixer rod of industrial steel grade 45 with the mixing capacity of min 2.5 kg putty per minute) Cont/-
Cont/- Step 2) Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of mechanised Spray Machine with max 6 ltrs per minutes with a maximum pressure 230 bar having maximum tip size 0.041" Step 3) Allow 6-8 hrs time to dry the putty surface Note: - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application). complete all as specified and directed.
M&L for preparing new plastered surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having excellent protection against UV, Alkali & Fungal resistance, exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm. of approved colour approved make with low VOC less than 50, Anti Alkali & fungal properties in two coats applied with fully automatic airless spray machine which shall be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer as mentioned in Particular Specifications and accessories having an electric motor of min. 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint with 6 years performance warranty from manufacturer of approved make complete all as directed.
M&L for 50mm thick red sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified and as directed.
M&L for applying chemical compound with dispersing agents Removing (and not damaging the beneath brick or RCC surface) old existing unserviceable concrete, cement plaster, loose / unsound weaken cement of any description and in any position from existing external / internal surfaces of walls, or any surface average depth 5-25mm (Approx height 4.5 m from natural ground level) with concrete removing agent(except for zinc and galvanised metal) and clean the treated surface immediately after removal treatment, and removal up to the approval municipal dumping grounds specified by the local bodies outside MOD land including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale/ rust etc from the visible unplastered surface. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire surface of bars free from loose torn metallic parts, loose material, dirt etc. and M&L for applying alkaline Antioxydizing agent on the existing rebars and allowing it to react with damaged metal and form a corrosion resistant, insoluble protective layer, as per manufacturer's instructions, including necessary scaffolding, props etc. complete all as specified and as directed. (Mode of measurement: per sqm of breaking area of concrete.) Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) complete all as specified and as directed. The rate shall include cost of scaffolding necessary for the work. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for mixing mechanically PP fibre of 12 mm length with Anti-crack strength in redymix repair mortar with suitable care to ensure dispersion of fibres conforming to ASTM C 1116/C, 1116M-10a 4.1.3 type3 & BS EN14889-2.2006 and providing 10mm thick one componentchloride freethixotropic fibre reinforced polymer mo dified repair mortar at external brick wall with ASTMC109 with flexural strength ASTMC 348 @ 7days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 in cement mortar in the ratio 1:4 mixed with styrene butydiene polymerized cement mortar modifier or AR for bonding with cementious mortar specially adhered to BS6319 having specific gravity of 1.025 to1.04, minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer’s Instructions. For external columns or any RCC wall surfaceetc. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for curing of the surface using wax based Concrete curing compound CC 75 curing efficiency; CC75 complies with the internationally recognized ASTM C309-90 standards incuding all toolsand tackles. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Taking down surface / concealed copper / aluminium point wiring (light, bell, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators, tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed.
All as per Sl item No 134.00 above here-in-before for light point controlled by two way switch complete all as specified and directed.
All as per Sl item No 134.00 above herein before but for one bell point controlled by one bell push complete all as specified and directed.
All as per serial item No. 134.00 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 134.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches.
M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.complete all as specified and directed.
M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular type 6A two way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular bell push, 6 Amp 240 volt one module complete all as specified and directed.
S & F Bell ding dong type, AC 230 volts all as specified and directed.
S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type 3/5 pin socket with one Single pole MCB 20 Amp 230 volt including concealing in wall suitable for AC and domestic appliances complete all as specified and directed.
S & F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
S&F Angle / batten holder polycorbonate type body suitable for batten fitting complete all as specified and directed.
S&F LED bulb of capacity 10/12 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed.
S&F in replacement LED (1.2m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10"%" AND PF>0.95 complete all as specified and directed.
S&F in replacement LED (0.6m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of capacity 5 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10"%" AND PF>0.95 complete all as specified and directed.
Supply & fixing in replacement security light with LED street light, 35 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed.
S&F in repair 10W integrated LED bulk head luminaire environment friendly, ultra modern, energy saving, surface mounted decorative oval bulk head with LED light, complete all as specified and directed.
Supply & fixing in replacement sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing in replacement of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
Supply & fixing in replacement of MCB Single Pole Neutral 240 volt any rating from 32 to 63 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
M&L for cutting/making hole 250/300mm dia in existing wall for fixing of Exhaust Fan including making good disturbed surfaces and matching with existing colour of walls complete all as specified and directed.
Supply, installation, testing & commissioning of electric storage water heater of 25 litre capacity, rated voltage 230 Volt, single phase, 50 Hz of rated power input-2000 Watt conforming to IS 2082 with standing loss ≤ 0.511 & ≥ 0.465 KWh/24Hr/45°C (5 Star BEE rating wef 01 Jan 2024) having dry powder coating in water stoarge tank of ultra thick super cold rolled steel plates of high-strength, sock proof ABS body using IPX4 technology to protect electrical parts from water to avoid direct contact between cold and hot water flow, glass coated incoloy heating element for good corrosion resistance with execllent resistance to both oxidation and carbonization, panel for temperature setting between 25°C to 75°C to control energy consumption, with 3 preset controls for easy operation, energy saving high density thick PUF insulation for better heat Cont/-
Cont/- reterition, having sacrificial magnesium anode rod with steel core to protect water tank from rust and corrosion to enhance the tank life, having safety feature like thermostate, thermal cut off, multifunction valve, shock-safe plug to prevent electric shocks by cutting off the power in case of current leakage suitable for high-rise buildings of 8 bar (0.8 Mpa) pressure including fixing & connecting accessories like mild steel anchor fastener of size 10 x 100mm with nuts and washers, drilling/making hole on wall with provision of stainless steel breaded (SS 304 Graded) connection pipe (01 Pair) in 600 mm long or as per site long enough to connected angle valve for hot & cold water circulation with nuts and washers and testing and including 15 mm bore CP angle valve of approved make and painting MES No. on geyser all as specified and and directed.
Supply and fixing Exhaust fan metallic body of size 300 mm sweep, 50 Hz, AC 240Volt, 900 RPM, dynamically balanced impellers for smooth & vibration free operation, pre-lubricated double ball bearing for maintenance free running with aerodynamically designed & balanced blade, air delivery 1275 Cum/hr, noise level 40dB- 45dB and power consumption (50 W±10%) heavy duty single phase supply including mild steel louvers all as specified and directed.
Supply and fixing in replacement of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 6.00, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. Note : Old unserviceable ceiling fan shall be deposited in AGE E/M store yard.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete including taking down old unserviceable earthing all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
Taking down of smart prepaid meter with accessories & refixing the same as original after completion of surface work with nut, bolts etc complete all as specified and directed.
S & F in replacement of worn out MCCB with MCCB 160 Amp 36 KA ,4 pole,Ics=100% Icu,thermal adjustable-0.8 to 1 In,Magnetc Adjustment 5 to 10 In,Adjustable sensitivity :0.03-0.3-1-3 A, Adjustable tripping: 0-0.3-1-3s.-02 Each complete all as specified and directed.
M&L for painting of steel surface of LT energy meter panel fro, inside and outside complete with two coat of synthetic enamel paint (spray painting) after removing loose paint and rust properly as per existing colour including necessary minor repair work complete all as specified and directed.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 50 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
S&F in replacement Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
BHARDWAJ CONSTRUCTIONS (BID ID -3496844)
B S ENTERPRISES (BID ID -3498493)
R N AGRAWAL (BID ID -3498333)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender1349.pdf
Tender Documents • 1.11 MB
BOQ_831304.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .