| 1 | L1₹32.8 LAdmitted-Finance SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L1 | Admitted-Finance | |
| 2 | L2₹34.6 L+₹1.8 L (5.46%)Admitted-Finance NO 353 DIGLIPUR 1 DIGLIPUR NORTH MIDDLE ANDAMAN 744 202 | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L2 | Admitted-Finance | |
| 3 | L3₹40.1 L+₹7.3 L (22.4%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹42.5 L+₹9.7 L (29.6%)Admitted-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Admitted-Finance | |
| 5 | L5₹46.5 L+₹13.7 L (41.9%)Admitted-Finance 06 GOVIND NAGAR PANCHAYAT USR TRANSPORT CAMPBELL BAY OLD FISHERMAN COLONY CAMPBELL BAY GREAT NICOBAR ISLANDS | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CHANDER SEKER ENTERPRISE L4 | USR Transport L5 | MOHAMMED SAFIQUE L1 | M/s Mohammed Shamim L2 | LANDMARK ENGINEERS & CONSULTANTS L3 | M/s K Moorthi L8 | SKV Engineering L7 | ANITA VARMA ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Manning and operation of 06 (six) Nos DG sets as per manufacturer’s manual, switching ON DG Set supply manually after cut off AED supply (including idle running of DG Set), bring to correct speed, adjust voltage and frequency on panel board for taking up the pre determined load every day for operation of DG sets (including Sundays and holidays) at CG DHQ-9 Aerial Bay in Diglipur all as directed by Engineer-in-charge.
1.01 Contractor shall employ 3 (Three) Generator operator (one in each shift) for running of 3 x 200 KVA, 50KVA and 20 KVA DG Sets in three shifts round the clock operation per day, 8 hrs per shift (I shift 0600 hrs to 1400 hrs, II shift 1400 hrs to 2200 hrs, III shift 2200 hrs to 0600 hrs) and for running of 30 KVA DG Sets in two shifts ( I shift 0600 hrs to 1400 hrs, II shift 1400 hrs to 2200 hrs) at site for operating above mentioned DG sets as under:- (ii) The contractor shall employ diesel engine mechanic once in a week for maintenance of DG sets as and when required for smooth functioning of the DG sets as directed by Engineer-in-charge without any extra cost.
1.02. (iii) Carrying out checks of DG sets as per manufacturer’s manual. (iv) Cleaning of fuel tank as required for DG sets. (v) Checking and topping of engine oil in sump of DG set. (vi) The actual consumption of diesel by DG sets shall be recorded by the contractor every day in the DG Set log books separately for each DG set as directed.(vii) Generator room and surroundings of generator room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. (viii) The unit rate quoted shall deem to include cost of consumable items such as cotton waste and Hessain cloth, T&P required for maintenance/ initial charging of batteries, distilled water/electrolyte required, stationery for log books, necessary registers, First aid box, operator dress including cotton overall combinations, rubber gum boots and hand gloves etc. as directed by Engineer-in-charge
1.03 (ix) The contractor shall also change the engine oil of the DG Sets as specified in the manufacturer's manual and directed by the Engineer-in-charge (x) The contractor shall also carry out cleaning of the of Centrifuge Cleaner of all the above mentioned DG Sets all as specified in the manufacturer's manual and directed by Engineer-in-charge. NOTE: Any additional manpower, if needed for performing the above mentioned maintenance work shall be made available by the contractor without any extra cost.
Details of DG set: Capacity- 50 KVA (a) Engine Number- 5H 3022/1000234; Make- Kirloskar
(b) Alternator Number- DS3D010E/ 104965; Make- Kirloskar. Details of DG set: Capcity- 20 KVA (a) Engine Number- 2H 3017/1222434; Make- Kirloskar (b) Alternator Number- CS3A0 12L18891-H; Make- Kirloskar.
Details of DG Set : Capacity-30 KVA
(a) Engine Number : 3H 3025-1420167, Make : Kirloskar Green (b) Alternate Number : CS-3-C0141A 18755H, Make : Kirloskar Green | 990 | Per shift | 1,100 ₹10,89,000 | 1,200 ₹11,88,000 | 825 ₹8,16,750 Lowest | 875 ₹8,66,250 | 1,050 ₹10,39,500 | 1,280 ₹12,67,200 | 1,250 ₹12,37,500 | 1,240 ₹12,27,600 |
| 2.00 | Contractor shall employ 02 (Two) Electricians, 01 (One) at DHQ-9 for operating and daily maintenance External and internal electrification shift from 0900 hrs to 1700 hrs, and 01 (One) for Manning the complaint cell Shift from 0900 hrs to 1700 hrs. Complain cell room and surroundings of Complaint cell room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. | 660 | Per shift | 1,000 ₹6,60,000 | 1,100 ₹7,26,000 | 815 ₹5,37,900 Lowest | 875 ₹5,77,500 | 900 ₹5,94,000 | 1,180 ₹7,78,800 | 1,250 ₹8,25,000 | 1,140 ₹7,52,400 |
| 3.00 | Contractor shall employ 01 (One) Valve man/Mate, (One Shift) at new and old OTM location in DHQ-9 for operating and daily maintenance External Water Supply, Maintain and operate pump house. Shift from 0900 hrs to 1700 hrs. Pump House and surroundings of Pump House are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. | 330 | Per shift | 900 ₹2,97,000 | 980 ₹3,23,400 | 725 ₹2,39,250 Lowest | 775 ₹2,55,750 | 800 ₹2,64,000 | 1,050 ₹3,46,500 | 1,000 ₹3,30,000 | 1,010 ₹3,33,300 |
| 4.00 | Contractor shall employ 01 (One) FGM, (One Shift) at Old OTM location in DHQ-9 for operating and daily maintenance External Water Supply, Maintain and operate pump house and 30KVA DG Set located near Pump house. Shift from 0900 hrs to 1700 hrs. Pump House and surroundings of Pump House are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. | 330 | Per shift | 1,100 ₹3,63,000 | 1,200 ₹3,96,000 | 815 ₹2,68,950 Lowest | 875 ₹2,88,750 | 1,000 ₹3,30,000 | 1,280 ₹4,22,400 | 1,250 ₹4,12,500 | 1,240 ₹4,09,200 |
| 5.00 | Supply and fix in repair Lube oil filter suitable for 10 KVA DG set of make Kirloskar complete all as specified and directed. | 4 | Each | 300 ₹1,200 | 385 ₹1,540 | 350 ₹1,400 | 275 ₹1,100 Lowest | 275 ₹1,100 Lowest | 410 ₹1,640 | 450 ₹1,800 | 300 ₹1,200 |
| 6.00 | Supply and fix in repair Fuel filter suitable for 10 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately) | 4 | Each | 400 ₹1,600 | 435 ₹1,740 | 375 ₹1,500 | 350 ₹1,400 Lowest | 400 ₹1,600 | 470 ₹1,880 | 450 ₹1,800 | 450 ₹1,800 |
| 7.00 | Supply and fix in repair Fan Belt suitable for 10 KVA DG set (Make - Kirloskar) | 2 | Each | 775 ₹1,550 | 790 ₹1,580 | 650 ₹1,300 | 550 ₹1,100 Lowest | 800 ₹1,600 | 850 ₹1,700 | 850 ₹1,700 | 820 ₹1,640 |
| 8.00 | Supply and fix in repair Air filter suitable for 10 KVA DG set (Make - Kirloskar) | 4 | Each | 2,700 ₹10,800 | 2,950 ₹11,800 | 700 ₹2,800 | 650 ₹2,600 Lowest | 2,900 ₹11,600 | 3,160 ₹12,640 | 2,850 ₹11,400 | 3,050 ₹12,200 |
| 9.00 | Supply and fix in repair Lube oil filter suitable for 20 KVA DG set of make Kirloskar complete all as specified and directed. | 2 | Each | 300 ₹600 | 380 ₹760 | 350 ₹700 | 275 ₹550 Lowest | 350 ₹700 | 410 ₹820 | 350 ₹700 | 390 ₹780 |
| 10.00 | Supply and fix in repair Fuel filter suitable for 20 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately) | 2 | Each | 400 ₹800 | 425 ₹850 | 375 ₹750 | 350 ₹700 Lowest | 450 ₹900 | 450 ₹900 | 450 ₹900 | 440 ₹880 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
18 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SOUTH DIGLIPUR
GARRISON ENGINEER SOUTH DIGLIPUR PROTHRAPUR PORT BLAIR 744105
MAINTENANCE AND OPERATIONS OF E/M INSTALLATION AT CGDHQ-9 AERIAL BAY AND ICGS MAYABUNDER
2021_MES_419788_1
8820/E8 (Recall)
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Port Blair
ALL BIDDERS ENLISTED WITH MES IN CLASS D AND CAT dv AND UNENLISTED BIDDERS MEET MES ENLISTMENT CRETERIA OF CLASS D AND CAT dv REFER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SOUTH DIGLIPUR
₹1.9 L
Yes
20 Feb 2021
6 Feb 2021
20 Feb 2021
6 Feb 2021
18 Feb 2021
13 Feb 2021
8 Feb 2021 - 11 Feb 2021
60 days
Amount
Manning and operation of 06 (six) Nos DG sets as per manufacturer’s manual, switching ON DG Set supply manually after cut off AED supply (including idle running of DG Set), bring to correct speed, adjust voltage and frequency on panel board for taking up the pre determined load every day for operation of DG sets (including Sundays and holidays) at CG DHQ-9 Aerial Bay in Diglipur all as directed by Engineer-in-charge. 1.01 Contractor shall employ 3 (Three) Generator operator (one in each shift) for running of 3 x 200 KVA, 50KVA and 20 KVA DG Sets in three shifts round the clock operation per day, 8 hrs per shift (I shift 0600 hrs to 1400 hrs, II shift 1400 hrs to 2200 hrs, III shift 2200 hrs to 0600 hrs) and for running of 30 KVA DG Sets in two shifts ( I shift 0600 hrs to 1400 hrs, II shift 1400 hrs to 2200 hrs) at site for operating above mentioned DG sets as under:- (ii) The contractor shall employ diesel engine mechanic once in a week for maintenance of DG sets as and when required for smooth functioning of the DG sets as directed by Engineer-in-charge without any extra cost. 1.02. (iii) Carrying out checks of DG sets as per manufacturer’s manual. (iv) Cleaning of fuel tank as required for DG sets. (v) Checking and topping of engine oil in sump of DG set. (vi) The actual consumption of diesel by DG sets shall be recorded by the contractor every day in the DG Set log books separately for each DG set as directed.(vii) Generator room and surroundings of generator room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. (viii) The unit rate quoted shall deem to include cost of consumable items such as cotton waste and Hessain cloth, T&P required for maintenance/ initial charging of batteries, distilled water/electrolyte required, stationery for log books, necessary registers, First aid box, operator dress including cotton overall combinations, rubber gum boots and hand gloves etc. as directed by Engineer-in-charge 1.03 (ix) The contractor shall also change the engine oil of the DG Sets as specified in the manufacturer's manual and directed by the Engineer-in-charge (x) The contractor shall also carry out cleaning of the of Centrifuge Cleaner of all the above mentioned DG Sets all as specified in the manufacturer's manual and directed by Engineer-in-charge. NOTE: Any additional manpower, if needed for performing the above mentioned maintenance work shall be made available by the contractor without any extra cost. Details of DG set: Capacity- 50 KVA (a) Engine Number- 5H 3022/1000234; Make- Kirloskar (b) Alternator Number- DS3D010E/ 104965; Make- Kirloskar. Details of DG set: Capcity- 20 KVA (a) Engine Number- 2H 3017/1222434; Make- Kirloskar (b) Alternator Number- CS3A0 12L18891-H; Make- Kirloskar. Details of DG Set : Capacity-30 KVA (a) Engine Number : 3H 3025-1420167, Make : Kirloskar Green (b) Alternate Number : CS-3-C0141A 18755H, Make : Kirloskar Green
Contractor shall employ 02 (Two) Electricians, 01 (One) at DHQ-9 for operating and daily maintenance External and internal electrification shift from 0900 hrs to 1700 hrs, and 01 (One) for Manning the complaint cell Shift from 0900 hrs to 1700 hrs. Complain cell room and surroundings of Complaint cell room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time.
Contractor shall employ 01 (One) Valve man/Mate, (One Shift) at new and old OTM location in DHQ-9 for operating and daily maintenance External Water Supply, Maintain and operate pump house. Shift from 0900 hrs to 1700 hrs. Pump House and surroundings of Pump House are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time.
Contractor shall employ 01 (One) FGM, (One Shift) at Old OTM location in DHQ-9 for operating and daily maintenance External Water Supply, Maintain and operate pump house and 30KVA DG Set located near Pump house. Shift from 0900 hrs to 1700 hrs. Pump House and surroundings of Pump House are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time.
Supply and fix in repair Lube oil filter suitable for 10 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 10 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 10 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 10 KVA DG set (Make - Kirloskar)
Supply and fix in repair Lube oil filter suitable for 20 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 20 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 20 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 20 KVA DG set (Make - Kirloskar)
Supply and fix in repair Lube oil filter suitable for 50 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 50 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 50 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 50 KVA DG set (Make - Kirloskar)
Supply & Fix of solenoid switch for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of exhaust silencer for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of voltmeter for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of digital hour meter for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of lub oil pressure gauge for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of water temperature guage for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of ampere meter for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of rectifier of suitable size for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of carbon brushes with holder for 50 KVA DG Sets complete all as specified and directed.
Supply & Fix of Ignition switch for 50 KVA DG Sets complete all as specified and directed.
Supply only battery charger of capacity voltage 6 Volt to 24 volts, ampere rage 1 Amp to 12 Amps complete all as specfied and dircted.
Supply & Fix of door hinges of suitable size DG Sets complete all as specified and directed.
Supply and fix in repair Lube oil filter suitable for 30 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 30 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 30 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 30 KVA DG set (Make - Kirloskar)
Supply & Fix of solenoid switch for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of exhaust silencer for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of voltmeter for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of digital hour meter for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of lub oil pressure gauge for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of water temperature guage for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of ampere meter for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of rectifier of suitable size for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of carbon brushes with holder for 30 KVA DG Sets complete all as specified and directed.
Supply & Fix of Ignition switch for 30 KVA DG Sets complete all as specified and directed.
Renewal of belt tension unit for 50 KVA DG Sets door hinges of suitable size for DG Sets complete all as specified and directed.
Supply and fix in repair Lube oil filter suitable for 200 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 200 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 200 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 200 KVA DG set (Make - Kirloskar)
M & L for topping up of coolant in radiator for DG Sets (Make : Kirloskar)
Supply and fix of 12 V 140AH maintenance free battery complete all as specified and directed.
Supply and fixing chequered rubber mat for electrical purpose of size 2Mx1Mx16mm thick ISI marked suitable for 11000 volts all as specified.
Supply and fixing AVR (Automatic Voltage Regulator) suitable for 200 KVA DG Sets complete all as specified.
Supply and fixed battery terminals (Brass)
M & L complete dismantling, servicing and repairs to FIP (Fuel Injection Pump) by Supply & Fix of oil seals, 'O' rings, bearings, gaskets; reassembling the FIP, caryying out calibration by setting required pressure and testing of 200 KVA DG Set all as specified and directed.
M & L taking down starter assembly, removing the worn out brushes and renewing the brushes as per manufacturer's specifications, checking commutatore surface, cleaning any dust, dirt, oil & foreign particles with dry clothes and compressed air; checking; repairing and greasing the drive assembly for the movement over soft spiness to enable drive assembly to move freely all as specified and directed.
Supply & Fix of solenoid switch for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of voltmeter for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of digital hour meter for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of lub oil pressure gauge for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of water temperature guage for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of ampere meter for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of rectifier of suitable size for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of carbon brushes with holder for 200 KVA DG Sets complete all as specified and directed.
Supply & Fix of Ignition switch for 200 KVA DG Sets complete all as specified and directed.
Manning and operation of 01 No. DG set as per manufacturer’s manual, switching ON DG Set supply manually after cut off AED supply (including idle running of DG Set), bring to correct speed, adjust voltage and frequency on panel board for taking up the pre determined load every day for operation of DG sets (including Sundays and holidays) at Indian Coast Guard Station Mayabunder all as directed by Engineer-in-charge. 1.01 Contractor shall employ 03 (Three) Generator operator (one in each Shift) for running of 100 KVA at site for operating above mentioned DG sets as under:- I shift 0600 hrs to 1400 hrs, II shift 1400 hrs to 2200 hrs and III shift 2200 hrs to 0600 hrs (ii) The contractor shall employ diesel engine mechanic once in a week for maintenance of DG sets as and when required for smooth functioning of the DG sets as directed by Engineer-in-charge without any extra cost. 1.02. (iii) Carrying out checks of DG sets as per manufacturer’s manual. (iv) Cleaning of fuel tank as required for DG sets. (v) Checking and topping of engine oil in sump of DG set. (vi) The actual consumption of diesel by DG sets shall be recorded by the contractor every day in the DG Set log books seperately for each DG set as directed.(vii) Generator room and surroundings of generator room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time. (viii) The unit rate quoted shall deem to include cost of consummable items such as cotton waste and Hessain cloth, T&P required for maintenance/ initial charging of batteries, distilled water/electrolyte required, stationery for log books, necssary registers, First aid box, operator dress including cotton overall combinations, rubber gum boots and hand gloves etc. as direced by Engineer-in-charge 1.03 (ix) The contractor shall also change the engine oil of the DG Sets as specified in the manufacturer's manual and directed by the Engineer-in-charge (x) The contractor shall also carry out cleaning of the of Centrifuge Cleaner of all the above mentioned DG Sets all as specified in the manufacturer's manual and directed by Engineer-in-charge. NOTE: Any additional manpower, if needed for performing the above mentioned maintenance work shall be made available by the contracor without any extra cost. (a) Details of DG set: Capcity- 100 KVA Make- Kirloskar (b) Alternator Number- Make- Kirloskar.
Contractor shall employ 01 Electrician, at Mayabunder for operating and daily maintance External and internal electrification and for Manning the complaint cell. Shift from 0900 hrs to 1700 hrs. Complaint cell room and surroundings of Complaint cell room are to be maintained neat, clean and dry as directed by Engineer-in-charge from time to time.
Supply and fix in repair Lube oil filter suitable for 100 KVA DG set of make Kirloskar complete all as specified and directed.
Supply and fix in repair Fuel filter suitable for 100 KVA DG set Primary/secondary filter (Make - Kirloskar) (Each filter shall be measured separately)
Supply and fix in repair Fan Belt suitable for 100 KVA DG set (Make - Kirloskar)
Supply and fix in repair Air filter suitable for 100 KVA DG set (Make - Kirloskar)
M & L for topping up of coolant in radiator for DG Sets (Make : Kirloskar)
Supply and fix of 12 V 140AH maintenance free battery complete all as specified and directed.
Suply and fixing AVR (Automatic Voltage Regulator) suitable for 100 KVA DG Sets complete all as specified.
M & L complete dismantling, servicing and repairs to FIP (Fuel Injection Pump) by Supply & Fix of oil seals, 'O' rings, bearings, gaskets; reassembling the FIP, caryying out calibration by setting required pressure and testing of 100 KVA DG Set all as specified and directed.
Supply & Fix of solenoid switch for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of exhaust silencer for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of voltmeter for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of digital hour meter for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of lub oil pressure gauge for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of water temperature guage for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of ampere meter for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of rectifier of suitable size for 100 KVA DG Sets complete all as specified and directed.
Supply & Fix of Ignition switch for 100 KVA DG Sets complete all as specified and directed.
Supply only battery charger of capacity voltage 6 Volt to 24 volts, ampere rage 1 Amp to 12 Amps complete all as specfied and dircted.
Renewal of belt tension unit for 100 KVA DG Sets door hinges of suitable size for DG Sets complete all as specified and dircted.
M/s Mohammed Shamim
LANDMARK ENGINEERS & CONSULTANTS
CHANDER SEKER ENTERPRISE
USR Transport
ANITA VARMA ENTERPRISES
SKV Engineering
M/s K Moorthi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .