| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.2 LAccepted-AOC | ₹57.2 L Quoted ₹58.4 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹58.8 LRejected-Finance | ₹58.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹72.3 LRejected-Finance | ₹72.3 L | L3 | Rejected-Finance L3 |
| 4 | L4₹73.4 LRejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹73.4 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | M/S MANOJKUMAR M NAGARKATTE L3 | SRI GURUPRASAD INFRATECH L2 | DURGAI ELECTRICALS L4 | HARSHITA MARINE SERVICES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of LT under ground cables/GI pipes getting out as in soft /loose soil complete all as specified and directed. | 550 | Cum | 269 ₹1.5 L | 350 ₹1.9 L | 320 ₹1.8 L | 270 ₹1.5 L |
| 2.00 | Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and directed. | 300 | Cum | 100 ₹30,000 | 130 ₹39,000 | 70 ₹21,000 | 98 ₹29,400 |
| 3.00 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 250 | Cum | 200 ₹50,000 | 176 ₹44,000 | 100 ₹25,000 | 225 ₹56,250 |
| 4.00 | Supply & filling sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 1991 of part -I
Note: Only punned thickness of the sand will be meausured. | 195 | Cum | 1,280 ₹2.5 L | 1,100 ₹2.1 L | 1,800 ₹3.5 L | 1,010 ₹2.0 L |
| 5.00 | Supplying and laying unreinforced precast concrete cable cover, class LV Type-1, flat size 250mm x 150mm x 40mm with ISI mark factory made complete all as specified and directed. | 16,550 | Each | 40 ₹6.6 L | 35 ₹5.8 L | 36 ₹6.0 L | 35 ₹5.8 L |
| 6.00 | Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole and keeping aside for reuse and remove the unservicable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and directed. | 3,310 | RM | 24 ₹79,440 | 10 ₹33,100 | 10 ₹33,100 | 10 ₹33,100 |
| 7.00 | Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core.
Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work | 860 | RM | 238 ₹2.0 L | 200 ₹1.7 L | 274 ₹2.4 L | 224 ₹1.9 L |
| 8.00 | Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 35 sqmm 3.5 core.
Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work | 750 | RM | 244 ₹1.8 L | 250 ₹1.9 L | 317 ₹2.4 L | 268 ₹2.0 L |
| 9.00 | Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 50 sqmm 3.5 core.
Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work | 350 | RM | 310 ₹1.1 L | 340 ₹1.2 L | 420 ₹1.5 L | 338 ₹1.2 L |
| 10.00 | Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 70 sqmm 3.5 core.
Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work | 260 | RM | 412 ₹1.1 L | 445 ₹1.2 L | 560 ₹1.5 L | 444 ₹1.2 L |
Updated dates
Tender Value
₹85.0 L
EMD Value
₹1.5 L
Closing Date
20 Nov 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR/ MAINT OF CERTAIN E/M INSTALLATIONS AT SAILORS RESIDENTIAL AREA NAVAL BASE KARWAR AND NSRY UNDER GE (SB) KARWAR
2025_MES_735463_1
86010/E8
Open Tender
Civil Works
KARWAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE(SB) KARWAR
₹1.5 L
Yes
16 Dec 2025
16 Oct 2025
22 Nov 2025
16 Oct 2025
20 Nov 2025
6 Nov 2025
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of LT under ground cables/GI pipes getting out as in soft /loose soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply & filling sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 1991 of part -I Note: Only punned thickness of the sand will be meausured.
Supplying and laying unreinforced precast concrete cable cover, class LV Type-1, flat size 250mm x 150mm x 40mm with ISI mark factory made complete all as specified and directed.
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole and keeping aside for reuse and remove the unservicable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and directed.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 35 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 50 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 70 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 95 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 120 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 185 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 240 sqmm 3.5 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 35 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 50 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 70 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 95 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 125 to 150 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 185 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 240 sq.mm complete all as specified and as directed by Engineer in Charge Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
M/L for MCCB 3 pole, 415 volts ,25 to100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,125 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,160 Amps with breaking capacity 25 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,200 Amps with breaking capacity 25 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,250 Amps with breaking capacity 36 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,400 Amps with breaking capacity 36 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 3 pole, 415 volts ,630 Amps with breaking capacity 50 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,125 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,160 Amps with breaking capacity 25 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,200 Amps with breaking capacity 25 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,250 Amps with breaking capacity 36 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,400 Amps with breaking capacity 36 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
M/L for MCCB 4 pole, 415 volts ,630 Amps with breaking capacity 50 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
Supply only Volt meter digital type 0-500 Volts
Supply only Ammeter digital type suitable to 0 - 100 Amps
Supply only Aluminum lugs suitable for 10 sqmm to 16 sqmm cables
Supply only Aluminum lugs suitable for 25 sqmm to 50 sqmm cables
Supply only Aluminum lugs suitable for 70 sqmm to 150 sqmm cables
Supply only Aluminum lugs suitable for 150 sqmm to 300 sqmm cables
Supply only Sheared rubber gasket suitable to LT panel board any description
Supply only Indicator lamp LED type 'RYB'
M & L for GI tubing 'Light' grade 50 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and as directed
M & L for GI tubing 'Light' grade 80 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and as directed
M & L for GI tubing 'Light' grade 100 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and as directed
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
S&F DWC high density polyethylene pipes having 100/95 mm dia with all fittings/coupler/connecting accessories cnfirming to IS : 16098 Part-02 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed
S&F DWC high density polyethylene pipes having 75/63 mm dia with all fittings/coupler/connecting accessories cnfirming to IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed
Servicing of Automatic Power Factor Correction (APFC) panel of the Capacity 300 KVAR complete comprising any type capacitors, APFC relay, MCCB, Cooling Fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contatct points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
Servicing of Automatic Power Factor Correction (APFC) panel of the Capacity 180 KVAR complete comprising any type capacitors, APFC relay, MCCB, Cooling Fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contatct points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
Servicing,Inspecting,checking,cleaning by using of blower,Lubrication ,greasing and carrying out preventive maintanance of ACB and ACB in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Excavation of existing cable of size 25 Sq mm to 150 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work
Excavation of existing cable of size 185 Sq mm to 300 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work
Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 600 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 amp of – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 100 amp – 03 No (ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp – 2 No (iii) MCB SPN 63 Amps - 4 Nos, (iv) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, all as directed by the Engr In Charge.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Taking down ceiling fan/ exhaust fan/wall mounted/heavy duty ventilation fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/ fixing back in the original position, connecting up and testing complete all as directed. NOTES: (a) The unit rate quoted shall deemed to include for minor items viz 'U' clamps with rubber reel, bolts, nuts, washers and safety pin/split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and sperately under respective items. (c) Rewinding of fan will be measured and paid for separately under respective items.
S & F in repair capacitor of 2.5 mfd, suitable for ceiling fan/exhaust fan complete all as specified and as directed.
S & F in repair capacitor of 3.5 - 4.0 mfd, suitable for heavy duty ventilation/exhaust fan complete all as specified and as directed.
S & F in repair bearing No 6201/6202/6203/6207 suitable for ceiling fan/exhaust fan/ventilation fan complete all as specified and directed.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required, all as per specified and as directed.
M&L for Rewinding of Metal body Exhaust fan of 230mm/250mm/300 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required, all as per specified and as directed.
M&L for Rewinding of Heavy duty metal body exhaust fan of 380mm/450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required, all as per specified and as directed.
Supply and fixing in repair of Down rod of 1.5 feet height fabricated out of MS pipe 12mm /15 mm dia heavy duty duly painted with one coat of white paint complete all as specified and as directed.
Supply and fixing in repair of Down rod for extension of existing fabricated out of MS pipe 12mm/15 mm dia heavy duty complete.
Supply and fixing in repair of PVC Canopy set (up and down) of Ceiling fans of 1200/1400mm sweep size heavy duty duly painted with one coat of white paint complete all as specified and as directed.
Supply and fixing in repair of Mettalic blade (set of three blades) suitable for existing ceiling fans of 1200/1400mm sweep size heavy duty duly painted with one coat of white paint complete all as specified and as directed.
Supply and fixing in repair of Mettalic blade (set of three blades) suitable for existings exhaust fans of 230/250/300 mm sweep size heavy duty duly painted with one coat of paint as per existing colour complete all as specified and as directed.
Supply and fixing in repair of Mettalic blade (set of 4 blades) of exhaust fans of 380/450 mm sweep size heavy duty duly painted with one coat of paint as per existing colour complete all as specified and as directed.
Supply and fixing in repair of Mettalic mounted frame with bracket of exhaust fans of 230/250/300 mm sweep size heavy duty duly painted with one coat of paint as per existing including, nut, bolts, washer and fastner complete all as specified and as directed.
Supply and fixing in repair of Mettalic mounted frame with bracket of exhaust fans of 380/450 mm sweep size heavy duty duly painted with one coat of paint as per existing including, nut, bolts, washer and fastner complete all as specified and as directed.
Supply and fixing in repair, Copper wound motor for exhaust fans of 230/300 mm sweep size heavy duty duly painted with one coat of paint of suitable colour complete.
Supply and fixing in repair, Copper wound motor for heavy duty exhaust fans of 380/450 mm sweep size duly painted with one coat of paint of suitable colour as per existing complete.
M&L for cleaning and preparation of surface to Painting with two coat (white colour) with synthetic enamel paint of Ceiling fans/Exhaust fan/wall mounted fan/turboforce wall fan of any capacity to reach upto satisfied finish and marking MES No with black paint complete all as specified and directed by Engineer-in-charge.
M&L for Rewinding, Motor of Heavy dutyTurbo force industrial metallic wall mounted air circulation fan of 600 MM /750 MM Sweep, 1 Phase, 1440 RPM, 200-250 Watt, as per existing make of almonard or crompton, by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement fastner, nut/bolts, gun metal bush, ball bearing, oscillator parts, on off switch, repair internal copper wiring as per existing where ever required all as specified and as directed.
M&L for Rewinding, Motor of Motor of heavy duty industrial metallic Pedestal air circulation fan of 600 MM Sweep, 1 Phase, 1400 RPM, 180/200 Wattage, as per existing make of almonard or crompton, by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement fastner, nut/bolts, gun metal bush, ball bearing, oscillator parts, on off switch, repair internal copper wiring as per existing where ever required all as specified and as directed.
S & F in replacement, heavy duty stainless steel chrome finished front and rear grill cover round shape as per existing colour, including motor bracket (3 Nos set) made of aluminium, suitable for 600 mm -750 mm sweep turbo force wall mounted fan and pesdetel air circulation fan, complete all as specified and as directed.
S & F in replacement, heavy duty aluminium alloy made wall fan mount support assembly (bracket cover) as per existing colour, suitable for 750 mm sweep turbo force wall mounted air circulation fan make of almonard/crompton, complete all as specified and as directed.
S & F in replacement, heavy duty aerodynamically designed made of high grade metal/aluminium alloy fan blades (Number of blade 03) having size of 18''/24''/30'' , as per existing size & colour, suitable for 600 MM - 750 MM Sweep, industrial turbo force wall mounted and pesdetel air circulation fan make of almonard/crompton, complete all as specified and as directed.
S & F in replacement, heavy duty stainless steel chrome finished fan rotor as per existing size, suitable for 600 MM - 750 MM Sweep turbo force wall mounted fan and pesdetel air circulation fan complete all as specified and as directed.
S & F in replacement, heavy duty stainless steel fan base round shape as per existing colour, suitable for 600 mm sweep industrial type pedestal air circulation fan make of almonard/crompton, complete all as specified and as directed.
Dismantling from duct mounted on wall/floor in tunnel at a height of 1.5 to 2 mtr and taking down/out, 3 phase, 415 Volt capacity motor of heavy duty duct direct drive ventilation fan of any sweep, installed at in tunnel/ dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/ fixing back in the original position, connecting up and testing complete all as directed. NOTES: (a) The unit rate quoted shall deemed to include for minor items viz clamps with rubber reel, bolts, nuts, washers and safety pin/split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and sperately under respective items. (c) Rewinding of fan will be measured and paid for separately under respective items.
M&L for Rewinding of 3 Phase,4 KW, 1400 RPM, 415 Volt motor, of direct drive duct mounted ventilation fan of 600 mm/1000mm/1200mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement, blades, ball bearing, repair internal copper wiring as per existing where ever required, complete all as specified and as directed.
M&L for Rewinding of 3 Phase,5.5 KW, 1400 RPM, 415 Volt motor, of direct drive duct mounted ventilation fan of 600 mm/1000mm/1200mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement, blades, ball bearing, repair internal copper wiring as per existing where ever required, complete all as specified and as directed.
M&L for Rewinding of 3 Phase,7.4 KW, 1400 RPM, 415 Volt motor, of direct drive duct mounted ventilation fan of 600 mm/1000mm/1200mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement, blades, ball bearing, repair internal copper wiring as per existing where ever required, complete all as specified and as directed.
S & F in replacement copper conductor pvc insulated sheathed cable 3 core 2.5 sqmm FR grade, fixed on wall/ ceiling with suitable size of saddles screws etc including taking down existing cable all as specified and directed.
S&F in replacement, 9 to 40 Amps capacity power contactor incliding making connection suitable for on/off wall mounted panel of duct type ventilation fan installed at in tunnel complete all as specified and as directed.
S&F in replacement, Ammeter digital typetype 0-100 Volts incliding making connection suitable for on/off wall mountrd panel of duct type ventilation fan installed at in tunnel services or Indoor LT Panel complete all as specified and as directed.
S&F in replacement, voltmeter digital type type 0-500 Volts incliding making connection suitable for on/off wall mounted panel of duct type ventilation fan installed at in tunnel services or Indoor LT Panel complete all as specified and as directed.
S&F in replacement, Electronic hooter system type of 3MH12 incliding making connection suitable for on/off wall mounted panel of duct type ventilation fan installed at in tunnel services or Indoor LT Panel complete all as specified and as directed.
Supply and fixing in replacement LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp in tunnel services including making connection complete all as specified and as directed.
S & F in replacement, 3.5/4 C x 10 Sqmm PVC stranded copper conductor cable of grade 0.65/1.1 Kv, FR grade, innersheathed, armoured for industrial purpose fixing on wall in tunnel services complete all as specified and as directed.
S & F in replacement, 3.5/4 C x 6Sqmm PVC stranded copper conductor cable of grade 0.65/1.1 Kv, FR grade, innersheathed, armoured for industrial purpose fixing on wall in tunnel services complete all as specified and as directed.
S & F in replacement, 3.5/4 C x 4 Sqmm PVC stranded copper conductor cable of grade 0.65/1.1 Kv, FR grade, innersheathed, armoured for industrial purpose fixing on wall in tunnel services complete all as specified and as directed.
S & F in repair , MS Louvers suitable for exhaust fan of size upto 450 mm sweep as per sample complete all as specified and as directed.
S & F in replacement, RCBO with SPN having capacity of 16 - 32 Amps, 30mA-300mA, 240/415 Volts, 50 Hz with 10 kA short circuit capacity, as per site require, for ensuring protection from leakage current, short circuit & over load of wall mounted panel in tunnel services inclusing making connection complete all as specified and as directed.
S & F in replacement, RCBO with TPN having capacity of 16 - 32 Amps, 30mA-300mA, 240/415 Volts, 50 Hz with 10 kA short circuit capacity, as per site require, for ensuring protection from leakage current, short circuit & over load of wall mounted panel in tunnel services inclusing making connection complete all as specified and as directed.
S & F in replacement, Two Pole RCBO with SPN having capacity of 16 - 32 Amps, 30mA-300mA, 240/415 Volts, 50 Hz with 10 kA short circuit capacity, as per site require, for ensuring protection from leakage current, short circuit & over load of wall mounted panel in tunnel services inclusing making connection complete all as specified and as directed.
S & F in replacement, 4 Pole RCBO with TPN having capacity of 16 - 32 Amps, 30mA-300mA, 240/415 Volts, 50 Hz with 10 kA short circuit capacity, as per site require, for ensuring protection from leakage current, short circuit & over load of wall mounted panel in tunnel services inclusing making connection complete all as specified and as directed.
S & F in replacement, SP&N enclosure with 2 pole and Earth Metal Plug & Socket for incorporating 20 A SP/DP MCB as per requir, fixed on wall surface including making connection complete all as specified and as directed.
S & F in repair, Rigid non-metallic, 32 mm dia PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
Testing of LT UG cable of any dia by checking the insulation resistance using 5000v x 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) and pin point the fault location complete all as specified & as directed for length upto 500 m . Note: In single stretch any Nos of fault shall be paid as each job.
S& F of Combi space heaters with built in capillary thermostat 15 amp,230V,100 w, 25 to 85 degree size 250x75x38 mm for Indoor LT panel boards, a long lifesturdy aluminium sheathed heater and accurate thermostat. High voltage test at 2kv/1Min, insulation resistance > 10Mega Ohms, Power rating with in +/- 5%, thermostst calibration all as specified and as directed..
M & L in repairs for straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for 3.5 core cable 6 to 16 Sq mm.
M & L in repairs for straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for 3.5 core cable 25 to 50 Sq mm.
M & L in repairs for straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for 3.5 core cable 70 to 95 Sq mm.
M & L in repairs for straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for 3.5 core cable 120 to 185 Sq mm.
M & L in repairs for straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for 3.5 core cable 240 Sq mm.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 125 Amps with breaking capacity 16 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 160 Amps with breaking capacity 36 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 200 Amps with breaking capacity 36 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 250 Amps with breaking capacity 36 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 350/400 Amps with breaking capacity 36 KA complete all as specified and directed.
S & F in repairs MCCB 4 pole, 415 volts adjustable type overload & short circuit setting including disconnecting the incoming/ outgoing cable connections and re-connecting with suitable aluminum lugs/ ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for 630Amps with breaking capacity 50 KA complete all as specified and directed.
S & F in repairs MCCB 3 Pole, 415 V, with Microprocessor release 630 Amps with breaking capacity 70 KA complete all as specified and as directed
Labour only for Laying or shifting existing serviceable LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, cable for 16 sqmm 4 core, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work.
Labour only for Laying or shifting existing serviceable LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, cable for 25 sqmm 4 core, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work.
Labour only for Laying or shifting existing serviceable LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, cable for 35 sqmm 3.5 core, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work.
Labour only for Laying or shifting existing serviceable LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, cable for 50/70 sqmm 3.5 core, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 16 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
S & F in repairs Extended/ Direct or Front Mounted rotary operator switch/handle suitable for MCCBs having capacity 3P/4P, 63 -630 Amps rating of indoor LT Panel Complete all as specified and as directed.
M & L for replacement of the old deteriorated existing bottom,external and internal steel surfaces of indoor panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enamel paint (grey in color) with using spray machine over a coat of red oxide primer on old prepared surfaces complete all as specified and directed by Engineer-in-Charge. NOTE: Rates quoted by the contractor are deemed to include fixing of cable glands,cable lugs and for writing/marking the MES /SM No and other relevant details with paint in the pattern and style as approved by the Engineer-in-Charge.
Supply and Fix 32 x 6 mm copper earth strip complete all as specified and as directed
Taking down carefully old unsv interlocked industrial switch socket or Tap off Boxes/Bus bar Junction Boxes/Plug in boxes 3 phase, 440 volts fixed on walls/ MS frame and removing them from site after taking into credit complete all as specified and as directed.
S & F in replacement, 3 Phase, 63 Amps, 440 volt capacity, Interlocked Industrial insulated switch socket combination ( 5 pin type) fixed on walls/MS frame of busbar at various locations complete all as specified and directed. The switch socket should also contain an MCCB or Fuse link with fuse of same capacity 63 Amps including door operated roatry type on off switch.
M & L for Cable dressing including flexible PVC Conduit size of 25 mm to 50 mm with suitbale clamp mounted on surface/wall complete all as specified and as directed.
SRI GURUPRASAD INFRATECH (BID ID -3478308)
M/S MANOJKUMAR M NAGARKATTE (BID ID -3478599)
DURGAI ELECTRICALS (BID ID -3477828)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
86010TENDER.pdf
Tender Documents • 0.62 MB
BOQ_823554.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid