Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹15.7 L+₹73,200 (4.88%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not found in order |
Tender Value
₹14.8 L
EMD Value
₹29,580
Closing Date
19 Oct 2021, 6:00 pmClosed
GE U Water Supply Delhi Cantt 10
GE U Water Supply Delhi Cantt 10
PROVISION OF PUMP HOUSE AUTOMATION SCADA WITH MONITORING AND CONTROLLING WITH ALL NECESSARY SPARES ON PUMP HOUSE AT PALAM BAGH
2021_MES_476057_1
8221/GE/WS/D-61/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE U Water Supply Delhi Cantt 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U Water Supply Delhi Cantt 10
₹29,580
Yes
2 Dec 2021
17 Sept 2021
21 Oct 2021
17 Sept 2021
19 Oct 2021
7 Oct 2021
Amount
Remote Terminal Unit (RTU) i) ARM based Micro Controller with inbuild memory having enough capability of storing data of minimum 15 days. ii) Inbuild 4G/3G/GPRS modem with fallback and suitable antenna to communciate with cloud. Static IP will not be available. iii) 4G/ 3G/ 2G SIM cards for 2 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network. Running expenses till 02 years will be borne by bidder without any intervention. System should support changing of service providers without changing SIM cards (future ready). iv) Future ready RTU must have Modbus, MBUS or any other future open-source protocol (that uses RS485 or TCP Port), must be provided free of cost for the period of at least 5 years (OEM declaration mandatory). v) Must have one RS485 and one ethernet port vi) Capable of capturing multi-function meter and relay status data along with Run Hours as well as other fields from any compatible substation equipment
vii) All device communication with cloud based SCADA must be secured using TLS/ SSL encryption. SCADA must not support non-secure connections. viii) System must work without any need of Static IP. No Static will be provided for any location. ix) SCADA application must be hosted in MEITY ( Ministry of Electronics and Information Technology, Govt of india ) empanneled data Centers ( Empanelled under Meghraj Initiative) (x) Modern RTU with modular design, embedded web-server, high level language programming and state of the art cyber security for small to mid-size applications. Powerful and efficient engineering in accordance and cyber security should be based on International/Inidan standards.
Supply & Fixing of Enclosure for SCADA Controller for the system all as specified and as directed. Panel of size (WDH) 500mm x 500mm x 250mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. Each Panel will be fitted with PVC cable alley, Suitable numbers of terminal blocks, DIN Rail and 16A DP MCB
SCADA Software for receiving station Software with 2 years subscription, maintenance and support as per specifications Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changable. Utility like billing reports must be supported. Multi-site data viewing within same interface without any physical cable connection of sites to SCADA room SCADA must be accessible over internet and must have adequate security with dual factor authentication with username/ password alongwith OTP on email. All device communication with Cloud based SCADA must be secured using TLS/SSL encryption. SCADA must not support non-secure connections. System must work without any need of static IP. No static IP will be provided for any location.
Replacement of existing meters with Three Phase Multi-function Meter of ACC Cl 0.5 with RS485 Communication Port for total of 04 motors . All three phase Multi-function meters must be capable of measuring Energy, load, power factor, Amps, Voltage complete with connection of all above meters in a single loop using RS485 two-wire STP Cable
Ultrasonic Type Water Meter with inbuilt battery for 8 years Life and RS 485 Pipe Diameter: DN32 (As per the tender specifications)
S&F of ultrasonic type water level sensor for underground tank suitable for up to 6 meter water level depth of U/G sump, with dead band of less than 0.6 meter, IP66 protection, accuracy of 0.25% of F.S. and with 4-20mA analog output. Should be capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centrigrade, non-condensing at 25 degree Centrigrade and humidity up to 95% with response time of less than 1 sec with 230 VAC to 24 VDC, 50 Hz power supply, LCD display type, vertical type mounting on top of OHTs with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed.
Two 22 AWG pairs stranded (7x32) tinned copper conductors, polyethylene insulation, twisted pairs, tinned copper braid shield (90% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket RS 485 Armoured Cable as per IEC-60332-1-2, Operating Temperature Range: -30° to 80° C for SCADA System
2.5 mm PVC Insulated multi strand copper cable
CT for 3 Phase Multi Function Meters
Single Pole MCB 6A for Multi Function Meters
ANDROID SMART PHONE APP : The SCADA service provider shall provide an android app that should enable key parameters monitoring along with alerts and control functionality. The android app must be a standard product from the OEM. The android app functionality should be default without any special setting and must have adequate username and password security.
4 Channel analog Input Card with SMPS of 24 VDC 10 A (As per SCADA OEM).
3 Pair 1.0 sq mm PVC insulated copper cable for SCADA controlling of Motors. The control cable will be housed in suitable casing capping/conduit pipes with related accessories from motors to the SCADA panels.
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .