Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | L1 | Accepted-AOC AOC | |
| 2 | Rejected-Technical KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Rejected as not L1 | |
| 3 | Rejected-Technical AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | - | Rejected-Technical Rejected as not L1 |
Tender Value
Refer Docs
EMD Value
₹1,400
Closing Date
19 Jul 2023, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
Office of the Project Officer, PE (EnM), Kathara C
Work of fresh electrical wiring of Guard room (02 nos.) and Toilet in colliery store and check post under Kathara Colliery
2023_CCL_283196_1
PO(KTC)/PE (EnM)/E-Tender/2023-24/28
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Office of the Project Officer, PE (EnM), Kathara C
AS PER NIT
5 documents required · 5 mandatory
₹1,400
28 Dec 2023
8 Jul 2023
20 Jul 2023
10 Jul 2023
19 Jul 2023
10 Jul 2023
10 Jul 2023 - 17 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1. Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1. Single Pole and Neutral
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 1. 2+4 Way/ 6 Way, Double Door
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing of 32 mm dia ISI marked PVC conduit
Providing and fixing of Main Switch 32 A, 240 V
Total impact of GST for the purpose of CTC
M/S JAY GURU CONSTRUCTION
M/S TIGER ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .