| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.1 L+₹3.1 L (8.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.9 L+₹10.0 L (28.5%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹36.3 L
EMD Value
₹72,600
Closing Date
6 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
PL REP TO OT LIGHT AND WORK SERVICES FOR KU BAND AT AF STN GORAKHPUR
2023_MES_573049_1
8972/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
Class D Cat a i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹72,600
Yes
28 Mar 2023
4 Jan 2023
8 Feb 2023
4 Jan 2023
6 Feb 2023
18 Jan 2023
4 Jan 2023 - 12 Jan 2023
Amount
S&F in repairs LED 50 double dome with Ondal arm and German imported spring shadowless LED OT light +360-degree rotation from the central and revolving axis,model no. LED 50 DOUBLE DOME with following specifications: Sl No MAIN DOME SATELLITE DOME Intensity @ 1 mtr distance(Lux) : 160000+10% 160000+10% Adjustable Field diameter(cm) : 14-38 14-38 Depth of illumination L1+L2(cm) : >100 >100 Color Rendering Index (CRI) (Ra): 95+3% 95+3% Color temperature(K) : 4500+10% 4500+10% Intensity control(%) : 25-100 25-100 Control : Dual control Dual control Mode of operation Manual and remote Manual and remote Type of field -foussing control : By sterilizable handle By sterilizable handle Type of Intensity control : By control panel By control panel location on lamp head on lamp head
Taking down and Re fixing carefully MCCB 200 Amps in the proposed panel complete all as specified and directed at site.
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar box outdoor type, plinth mounted, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (2mm) thick MS Sheet overall size to accommodate the following and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers and apply spray paint with powder coated painting. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and shall be completed with 400 amps capacity solid aluminium bus bar having 1100 volts grade sleeving and internal connection should be provided with aluminium strips of suitable size and to accommodate the following MCCBs, necessary foundation work complete all as specified and as directed (Note : (a) The MCCBs will be measured and paid separately. (b) The item rate is inclusive of necessary Bus Bar, volt meter, ammeter, control wiring, CT, instrument fuze holder, LED indication lamps etc). (a) 4 Pole MCCB 63 to 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA(incoming).-01 No (b) 3 Pole MCCB 32 to 100 Amp, 50 Hz, 415 V with rupturing capacity 10 KA (outgoing) - 01 No ( c) 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA(Outgoing)-o1 No. (d) Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps.-01 No.
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar box outdoor type, plinth mounted, totally enclosed dust and vermin proof open able from both front and rear side made out of 14 SWG (2mm) thick MS Sheet overall size to accommodate the following and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers and apply spray paint with powder coated painting. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and shall be completed with 400 amps capacity solid aluminium bus bar having 1100 volts grade sleeving and internal connection should be provided with aluminium strips of suitable size and to accommodate the following MCCBs, necessary foundation work complete all as specified and as directed (Note : (a) The MCCBs will be measured and paid separately. (b) The item rate is inclusive of necessary Bus Bar, volt meter, ammeter, control wiring, CT, instrument fuze holder, LED indication lamps etc). (a) 4 Pole MCCB 250 to 320 Amp, 50 Hz, 415 V with rupturing capacity 35 KA (incoming).-01 No (b) 4 Pole MCCB 63 to 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (outgoing) - 01 No
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core complete all as specified and directed at site.
S & F Sheet metal enclosure DBs Triple Pole and Neutral 4- way with 200 Amps rated bus bar 415 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge.
S & F Sheet metal enclosure DBs Tripple Pole and Neutral 4- way with 200 Amps rated bus bar 415 volts single pole and neutral complete double door with provision of one incoming MCCB complete all as specified and directed by Engineer in charge .
Supply and fix 4 Pole MCCBs 415V, 63A with rupturing capacity 16 KA complete all as specified and directed by Engineer in charge .
S & F MCB TPN 415 volts 40 Amps, C Series complete all as specified and directed by Engineer in charge Make- Legrand , ABB & C&S.
S & F MCB single pole 240 volts 40 Amps, C Series complete all as specified and directed by Engineer in charge. Make- Legrand,L&T,ABB
M/L for Sub Main Wiring with Two single core PVC insulated cable of size 6.0 Sqmm multi-stranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting, fixing accessories and 4 Sqmm multi-stranded copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 6 sq mm Wire and One No of 4 Sqmm Earth wire in One RM length Measured as one unit length.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity upto 20 KVA. Model No: X1.3TAAG7
Supply and install high wall split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed at site.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed at site.
M&L for Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6mm complete all as specified and directed at site.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed at site.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron strip 25×4mm as earthing lead by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M/L for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge. Make- Anchor, Plzaa, Leader.
M/L for Socket outlet 5 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge Make- Anchor, Plzaa, Leader.
M/L for Switch socket combination 5 pin 15 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge Make- Anchor, Plzaa, Leader.
S&F 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. complete all as specified and directed at site.
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 2 core complete all as specified and directed at site.
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core complete all as specified and directed at site.
Excavation in trenches, n. exc. 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10sqm on plan and n exc. 1.5m in depth and getting out in any type of soil complete all as specified and directed at site.
M/L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed at site.
M/L for Bricks, common burnt clay building bricks, sub class 'B' of size 225mmx115mmx75mm for protection of cable in trenches. complete all as specified and directed at site.
M/L for Removing excavated material n. exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M/L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and as directed.
M/L for GI Tubes, of size 50 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for Point wiring with PVC insulated 2.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of anticorrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white Bakelite sheet cover for mounting of switches, sockets etc and PVC insulated 1.5 Sqmm multi-stranded copper conductor cable as earth wire and for 3 pin switch socket outlet15Amp independent board and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
M/L for Switch socket combination 5 pin 15 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge Make- Anchor, Plzaa, Leader.
S & F Sheet metal enclosure DBs Single Pole and Neutral 2 way without bus bar 240 volts single pole and neutral single door complete all as specified and directed by Engineer in charge Make- Legrand, L&T,ABB
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (a) MCB SPN 32 Amps
Dismantling fencing wire mesh, any type complete all as specified and directed at site
Dismantling posts or struts (wood, steel or RCC), any section, including taking out embedded portion and making good disturbed ground; posts embedded in natural ground complete all as specified and directed at site.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed at site.
Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed at site.
M&L Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed at site.
M&L Mild steel work conforming to Fe 290 Gde E-165 as in nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed at site.
Fixing only posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed at site.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed at site.
Supply only chain link mild steel galvanized fencing, any type or size complete. (Weight of chain link fencing shall be decided through a BOO.) Complete all as specified and directed at site.
M&L Mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10cm but not exceeding 15 Cm long and dia of shank 11 to 15mm complete all as specified and directed at site.
M&L Mild steel round bars conforming to Gde I (IS: 432 part-I) 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed at site.
M&L Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm to 80mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed complete all as specified and directed at site.
M&L Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide primer complete all as specified and directed at site.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed at site.
M&L 100mm thick Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling in sub base of floor including necessary form work complete all as specified and directed at site.
M&L forming construction joint 30mm deep x 10mm wide and filled with sealing compound grade A complete all as specified and directed at site.
Hindustan Power Corporation
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .