Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 385 GROUND FLOOR GANESH MURTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹1.2 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.6 Cr+₹27.7 L (21.1%)Rejected-Finance FLAT NO B 401 4TH FLOOR NAVADURGA CO OP HSG SOCIETY LTD PLOT NO 7 SECTOR 19A NERUR EAST NAVI MUMBAI THANE MAHARASHTRA 400 706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | ₹1.6 Cr+₹27.7 L (21.1%) | L2 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | MADHU ENTERPRIZES L1 | ROHIT CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame), Complete all as specified and directed by Engineer-in-Charge. | 10 | Each | 90 ₹900 Lowest | 100 ₹1,000 |
| 2.00 | Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame), Complete all as specified and directed by Engineer-in-Charge. | 6 | Each | 100 ₹600 Lowest | 100 ₹600 Lowest |
| 3.00 | Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each, Complete all as specified and directed by Engineer-in-Charge. | 4 | Leaf | 100 ₹400 | 80 ₹320 Lowest |
| 4.00 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings, Complete all as specified and directed by Engineer-in-Charge. | 18 | RM | 350 ₹6,300 Lowest | 450 ₹8,100 |
| 5.00 | S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site. complete all as specified, Complete all as specified and directed by Engineer-in-Charge. | 11.35 | Sqm | 2,400 ₹27,240 Lowest | 2,500 ₹28,375 |
| 6.00 | S&F 30mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side, Complete all as specified and directed by Engineer-in-Charge. | 7.5 | Sqm | 2,700 ₹20,250 | 2,000 ₹15,000 Lowest |
| 7.00 | Supply & fixing powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified
Note: - (i) Glass panes will be measured & paid separately.
(ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight.
(iii) Minimum thickness of powder coating shall be 25 micron.
(iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.
(v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05. | 410 | Kg | 480 ₹1,96,800 | 450 ₹1,84,500 Lowest |
| 8.00 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as specified and directed, Complete all as specified and directed by Engineer-in-Charge. | 570 | Kg | 480 ₹2,73,600 | 450 ₹2,56,500 Lowest |
| 9.00 | S&F aluminium grill with and including suitable aluminium anodised frame F/H section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed by Engr-in-charge, Complete all as specified and directed by Engineer-in-Charge. | 19 | Sqm | 1,000 ₹19,000 Lowest | 1,100 ₹20,900 |
| 10.00 | S&F 4mm thick selected quality sheet glass for aluminium windows/shutters etc glazing with oil putty and rubber gasket in square n exc 0.5 sq. m in each pane etc all as directed, Complete all as specified and directed by Engineer-in-Charge. | 15 | Sqm | 550 ₹8,250 | 500 ₹7,500 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
1 Dec 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
AS PER TENDER
2025_MES_738395_1
8494/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
240 days
GE (NW) Kunjali
Class B category a (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹2.2 L
Yes
20 Mar 2026
4 Nov 2025
3 Dec 2025
4 Nov 2025
1 Dec 2025
26 Nov 2025
4 Nov 2025 - 25 Nov 2025
Amount
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame), Complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame), Complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each, Complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings, Complete all as specified and directed by Engineer-in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site. complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified Note: - (i) Glass panes will be measured & paid separately. (ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight. (iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area. (v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
S&F aluminium grill with and including suitable aluminium anodised frame F/H section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, as directed by Engr-in-charge, Complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, Complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete, Complete all as specified and directed by Engineer-in-Charge.
S&F in 12mm thick, toughened glass including itching etc for door shutters, partitions, shelves etc with and including fitting and fixtures such as glass handles ss studs, fittings for door pivots etc complete all as directed, Complete all as specified and directed by Engineer-in-Charge.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium ally sheet foundation box, main body with stainless steel cover, governing pivot made of bras, other parts made of mild steel heavy duty and fixed all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
S & F in Roller venetion blinds type made out of standard cloth of approved texture with necessary accessories etc complete, Complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed, Complete all as specified and directed by Engineer-in-Charge.
S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed, Complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F 125mm long Butt hinges, heavy weight, cold rolled mild steel, and fixed, Complete all as specified and directed by Engineer-in-Charge.
S&F 100mm long SS Butt hinges, medium weight, Complete all as specified and directed by Engineer-in-Charge.
S&F in repair 100 mm size mortice lock with two lever (vertical type) brass body and fixed complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F in 140 mm long floor door stopper of aluminium door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as specified, Complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets etc all as directed, Complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium snap grid size 605x605mm frame work for false ceiling all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
M&L for false ceiling made out of 600x600x 4 mm thick (non asbestos fiber cement designer/coloured) ceiling board / tiles deep panel as per sample, Complete all as specified and directed by Engineer-in-Charge.
M&L for POP false ceiling using 600X900x12mm thick plaster of paris with gypsum binder sheet decorative type including two coats of plastic emulsion paint and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old un serviceable false ceiling, complete all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 18/19 mm thick prelaminated partical board exterior grade prelaminated one side with lamination and other side balancing white lamination fixed with screw to frame work cupboard etc complete all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
M&L 0.9mm thick decorative texture finish laminate type 1, of surface finish colour and pattern as approved fixed with adhesive as per makers instruction complete all as specified and as directed, Complete all as specified and directed by Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall vertically with screws and C/C distance 30 CM to make PVC frame as per specification and drawing, Complete all as specified and directed by Engineer-in-Charge.
S&F PVC wall /ceiling paneling consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, Complete all as specified and directed by Engineer-in-Charge.
S&F 2mm thick Linoleum, plain coloured laid in floors including stretching, cutting, fitting incl seals down with an approved adhesive all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Wall paper of fibrous material, nonwoven Vinyl free, making them fixed to wall with dry strips or with approved adhesive, Complete all as specified and directed by Engineer-in-Charge.
M & L for Breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chisel which should tempered regularly of high frequency low impact hammer is used, cleaning the surface by water jet pressure pump at 4 to 5 kg/sq.cm pressure to remove chlorides and loose partials, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) etc. Complete all as specified and directed by Engineer-in-Charge.
M & L for Cleaning the existing reinforcement with hammer tapping and wire Brush/ rotary wire brush, fixed to hand drill machine, making the surfaces free from loose corrosion material, dirt scaling etc. complete. Applying two coats of polymer based alkaline rust converting primer confirming to ASTM-B 117 by means of paint brush, liberally all over in two coats of 1 hour between the coats, The product should converts the rust in to stable organo metallic complex molecule layer, this should also act as primer to further treatment of steel etc. complete. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor. (the damage ceiling/ concrete will be measured) etc. complete, Complete all as specified and directed by Engineer-in-Charge.
M & L for Anticorrosive treatment to Reinforcement application of two coats of IPNETRB (CBRI known how) on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be by brush, Application is allowed to dry for further treatment. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) etc. complete, Complete all as specified and directed by Engineer-in-Charge. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
M & L for Providing and applying two coats of concrete penetrating hi-tech corrosion inhibition mechanism inhibits corrosion of steel in concrete at the poles, cathode & anodic simultaneously on concrete surface which is prepared earlier. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged ceiling/ concrete will be measured) etc., Complete all as specified and directed by Engineer-in-Charge. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
M & L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. in flat rough finished surfaces of concrete, Complete all as specified and directed by Engineer-in-Charge.
M & L for Providing and applying 15 mm thick polymer mortar to load carrying R.C.C member in two layers in proportion of 1:5:15 by weight polymer of approved quality and make, cement and wash quartz sand with required W.C. ratio for desired floating, curing after initial setting time etc. , Complete all as specified and directed by Engineer-in-Charge.
Providing fabricating & fixing in position Tor steel TMT bar (CRS) reinforcement conforming to IS 1786 or 1985 (third revision) code specifications including cutting, bending placing as per IS 2502=1963 at any position / level with 0.9mm dia annealed binding wire also including wastages etc. all complete, Complete all as specified and directed by Engineer-in-Charge.
Providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C-882-87 using nylon brushes scaffolding labour etc. complete, Complete all as specified and directed by Engineer-in-Charge.
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer-in-charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. complete, Complete all as specified and directed by Engineer-in-Charge.
M & L for Drilling and fixing Teflon perforated nozzles in RCC member, including drilling 14 mm dia. 50 to 100mm deep holes in structural members at intervals of 600 mm in staggered manner as directed by the consultants in RCC structural elements. Clean the holes by air blower prior to fixing nozzles. fixing of nozzles in cleaned holes. external end of nozzles to be machined to receive outlet of grouting gun. nozzle is fixed by means of epoxy by means of epoxy sealant to ensure complete sealing. cure the system for min. 12 hours. the work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. etc, Complete all as specified and directed by Engineer-in-Charge. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry, Complete all as specified and directed by Engineer-in-Charge. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and rubbishing off the premises etc complete all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick in CM 1:6 on brick surfaces, fair finished on walls complete all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
M&L rendering 5mm thick in CM 1:3 on concrete surfaces as in ceiling finished even & smooth without using extra cement in ceiling, Complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick in CM 1:4 on brick walls complete all as specified and as directed.
M&L rendering 20mm thick Pre polymer modified ready mixed cement based plaster in two coats (12mm inner coat 8mm finishing coat). Polymer modified ready mixed cement based plaster should having min composition of cement and sand 1:4 using fully treated dry, well graded natural sand confirming to IS 383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces including making grooves of existing size complete all as specified and directed by Engineer-in-charge,
M&L for rendering 20 mm thick in two coats (15 mm base coat + 5 mm finishing coat) on brickwork or concrete surfaces in CM 1:4, finished even and fair, including mixing integral waterproofing compound in the finishing coat as per manufacturer’s instructions and providing scaffolding for high-rise work, complete all as specified and directed. Note: Waterproofing compound shall be measured and paid separately.
Supply only integral water proofing compound, Complete all as specified and directed by Engineer-in-Charge.
Dismantling stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc Complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish to the outside of MD land, Complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, Complete all as specified and directed by Engineer-in-Charge.
M&L for coloured glazed ceramic tiles 450x300x7-8 mm thick but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3, Complete all as specified and directed by Engineer-in-Charge.
M&L light shade double charged vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, Complete all as specified and directed by Engineer-in-Charge.
M&L light shade double charged vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm), but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, Complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm thick mirror polished Granite (of any type) work as in steps, jambs, pillars, cooking platforms, working table and like over 15 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, Complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
M&L for 18 to 20mm thick green marble (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like incl 15mm screed in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC valveless syphonic action type, flushing cistern Low level white, with inlet ball valve, float and handle 10 Ltr capacity including brackets, Complete all as specified and directed by Engineer-in-Charge.
SS&F in repair wash hand basin vitreous china white (flat back) of size 550x400mm including bracket 15mm dia 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F in repair counter type wash hand basin (oval shape) vitreous china white including 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs fancy type CP stop/angle cock of 15 mm dia, screwed for iron pipe and fixed as per sample and directed by Engr-in-Charge.
S&F in repairs fancy type bib cock 15 mm dia, screwed for iron pipe and fixed complete as directed by Engr-in-Charge.
S&F in repairs fancy type CP Pillar taps 15 mm dia, cast copper alloy, with capstan heads, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union fixed complete all as specified, Complete all as specified and directed by Engineer-in-Charge.
S & F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified, Complete all as specified and directed by Engineer-in-Charge.
S&F 450 mm PVC connections 15 mm size with PTMT nuts, Complete all as specified and directed by Engineer-in-Charge.
S&F 600mm PVC connections 15 mm size with PTMT nuts, Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
S & F in repairs Stainless steel soap dish holder fixed with suitable screw as per sample and complete directed by the Engr-in-Charge.
S&F in repairs coner glass shelf incl bracket fixed with suitable screw as per sample and complete directed by the Engr-in-Charge.
S&F in repairs CP towel rail 600 mm long with round flange complete all as specified and as directed, Complete all as specified and directed by Engineer-in-Charge.
Taking down CI/PVC/AC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 100mm dia pipe.
Taking down CI/PVC/AC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 75/80mm dia pipe.
Supply & Fixing 110mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply & Fixing 75 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply & Fixing 160 mm bore PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls with dash through fastners and rain water bracket suitable for 110mm bore pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 or laid in floor complete all as specified.
Supply & Fixing PVC (SWR) bends any radius 110mm bore complete all as specified and as directed
Supply & Fixing PVC (SWR) bends any radius 75mm bore complete all as specified and as directed
Supply & Fixing in repairs 110 mm bore PVC (SWR) bends, single/double 'Y' or 'T' with access doors any radius including rubber ring joints and fixing clips complete all as specified and as directed .
Supply & Fixing in repairs 75 mm bore PVC (SWR) bends, single/double 'Y' or 'T' with access doors any radius including rubber ring joints and fixing clips complete all as specified and as directed .
Supply & Fixing in repairs 160 mm bore PVC (SWR) bends, single/double 'Y' or 'T' with access doors any radius including rubber ring joints and fixing clips complete all as specified and as directed .
S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia, Complete all as specified and directed by Engineer-in-Charge..
S & F PVC (SWR) branch piece 110 mm single Y Complete all as specified and directed by Engineer-in-Charge.
S & F PVC (SWR) branch piece 75 mm single Y Complete all as specified and directed by Engineer-in-Charge.
S&F PVC vent cowl 110mm dia, Complete all as specified and directed by Engineer-in-Charge.
S&F PVC vent cowl 110mm dia, Complete all as specified and directed by Engineer-in-Charge.
Taking down CI/PVC/AC pipes (including all fittings), with spigot and socket ends and joints in cement or rubber gasket of 150/160mm dia pipe, Complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
S&F mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, Complete all as specified and directed by Engineer-in-Charge.
S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS -1161 1979 grade St-240, Complete all as specified and directed by Engineer-in-Charge.
S&F mild steel framed work such as grills, gratings,chequred plates etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; walkj ways, railings, frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified .
Supply & fixing for rolled mild steel Sections of Grade Fe 410-W, (Gde- E-250) quqlity-A, as in post, runners, rafters, purlins, trusses, steps etc fixed with connecting plates including bending, welding etc complete all as specified and directed Engr-in-Charge.
Supply and fixing mild steel plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without any attachment including all necessory drilling, bolting,riveting or welding conforming to FE 410-W, (Gde- E-250) quality-A complete all as specified.
S&F for Hand rails, half round or other stock section , nosing to steps in cluding embeding in concrete and screwing etc. wind ties for roof, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe 290 gde E 165 complete all as specified and directed.
Dismantling plain or corrugated steel/AC roof sheets any gauge, thickness, including Nainital or similar pattern roof covering all as specified and directed, Complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted hot- dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed.
S&F pre-painted hot- dip aluminium-zinc alloy metallic coated plain steel sheet, corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.5 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and as directed
M&L for applying 3 mm thick wall care putty to make the surface even and smooth, complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of newly plastered wall surfaces, soffits, fascia, roof etc. and applying two coats of SmartCare Damp Block 2K or equivalent acrylic polymer modified cementitious coating, including SmartCare crack seal coat and necessary scaffolding for high-rise work, complete all as specified and directed.
M&L for preparation of old decorated wall/soffit/fascia surfaces and applying two coats of 100 % acrylic weatherproof paint, including necessary scaffolding for high-rise work, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coat of oil emulsion distemper complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and distempering with first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and required shade, over a coat of alkali resistant primer, as per manufacturer’s specifications. Two or more coats on new work, complete all as specified and directed.
M&L for preparation of newly plastered ceiling surfaces and distempering with first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and required shade, over a coat of alkali resistant primer, as per manufacturer’s specifications. Two or more coats on new work, complete all as specified and directed. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
M&L for preparation of newly plastered wall surfaces and finishing with Premium Acrylic Smooth exterior paint with silicone additives, of required shade. Two or more coats @ 1.43 ltr/10 sqm over and including priming coat of exterior primer @ 2.20 kg/10 sqm, including necessary scaffolding for high-rise buildings. Complete all as specified and directed. Note- Work shall be carried out through authroised vender only as per standard engineering practices.
M&L for complete removal of existing treatment on old decorated wall surfaces and applying first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and required shade, over a coat of alkali resistant primer, as per manufacturer’s specifications. Two or more coats on new work, complete all as specified and directed.
M&L for complete removal of existing treatment on old decorated ceiling surfaces and applying first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer and required shade, over a coat of alkali resistant primer, as per manufacturer’s specifications. Two or more coats on new work, complete all as specified and directed.
M&L for complete removal of existing treatment on old decorated wall surfaces and finishing with Premium Acrylic Smooth exterior paint with silicone additives, of required shade. Two or more coats @ 1.43 ltr/10 sqm over and including priming coat of exterior primer @ 2.20 kg/10 sqm, including necessary scaffolding for high-rise buildings. Complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth, and applying two coats of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm in width or girth, and applying one coat of synthetic enamel paint, including necessary scaffolding for high-rise buildings. Complete all as specified and directed.
M&L for preparation of newly wooden surfaces of any description over 10 cm in width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer, including preparation of surfaces. Complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description over 10 cm in width or girth, and applying one coat of synthetic enamel paint, including external windows with necessary scaffolding for high-rise buildings.
M&L for applying 1 mm to 2 mm thick wall care putty to make the surface even and smooth, complete all as specified and directed by the Engineer-in-Charge.
M&L for applying two coats of oil emulsion distemper over newly plastered / putty finished wall surfaces, complete all as specified and directed by the Engineer-in-Charge.
S&F for stainless steel letters of size 225 mm x 32 mm and 1 mm thick stainless steel sheet, with seamless welding, rubbed and polished finish, and smooth edges. Letters to be fixed in position using necessary fixing devices, complete all as specified and directed.
Removing building materials etc. to a distance of 10 km, including loading, unloading, transportation and stacking at destination, complete all as specified and directed.
Dismantling single layer Mangalore pattern tiles or similar tiles in roofing laid dry, complete all as specified and directed.
Dismantling single layer Mangalore pattern tiles or similar tiles in roofing bedded in cement mortar, complete all as specified and directed.
S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers in roofs, walls, etc., with zinc coating 275 g/m², complete all as specified and directed.
S&F 0.63 mm thick plain galvanised mild steel sheeting in ridges, hips, valley gutters, drips and straight flashings (length and girth as fixed), with zinc coating 275 g/m², fixed with coach screws and washers, complete all as specified and directed.
Dismantling unframed timber scantling 40 sq cm and over in section, in any position, complete all as specified and directed.
DDismantling unframed timber scantling under 40 sq cm in section, in any position, complete all as specified and directed.
Dismantling boarding of any description, fixed in any position with nails, complete all as specified and directed.
M&L for second class hard wood timber scantling, clean sawn, unframed, complete all as specified and directed.
S&F second class hard wood plain fillets, clean sawn, square / rectangular / triangular in section, sectional area exceeding 13 sq cm but not exceeding 25 sq cm, fixed with nails, complete all as specified and directed.
M&L for second class hard wood battens for tiles, clean sawn, sectional area exceeding 15 sq cm and not exceeding 25 sq cm, fixed at 30 cm centres, complete all as specified and directed.
M&L for Mangalore pattern roof tiles, interlocking at side joints and laid dry, complete all as specified and directed.
M&L for Mangalore pattern ridge tiles, bedded and jointed in cement mortar 1:6, complete all as specified and directed.
M&L for preparing the surfaces of tile battens, new or old, of any size and spacing, and applying two coats of creosote oil, measured over one side only (spaces not deducted), complete all as specified and directed.
S&F 12mm thick prelaminated medium density particle board,interior grade, prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work complete all as specified and directed.
S&F aluminium extruded body door closer, hydraulically regulated, designation No. 1 (universal type), suitable for door shutters up to 700 mm in width and of weight not more than 35 kg, fixed complete all as specified and directed.
S&F in repairs, plastic water closet seat, black or white, closed pattern with flat bottom and cover, with mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
S&F in repairs, flush pipe of polyethylene (low or high density) or PVC, 32 mm dia, for low level cistern, complete all as specified and directed.
S&F in repairs, health faucet, ABS body, 8 mm dia, 1 m flexible tube and wall hook, (Make: Cera / Jaquar), complete all as specified and directed..
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire, average width of aperture 1.40 mm, fixed with stainless steel staples, complete all as specified and directed.
S&F 12 mm thick pre-laminated medium density particle board, interior grade, pre-laminated both sides with decorative choice lamination, fixed with screws to aluminium framework, complete all as specified and directed..
M&L for applying two coats of oil bound distemper over newly plastered or putty finished wall surfaces, complete all as specified and directed.
Complete removal of existing wall treatment by scrapping, washing and rubbing down with water, and applying two coats of oil bound distemper over a coat of chalk whiting, on plastered surfaces, complete all as specified and directed.
M&L for applying 1 to 2 mm thick wall care putty (JK/Birla) to make the surface even and smooth, complete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of old decorated ceiling surfaces and applying one coat of oil emulsion distemper, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposing off complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
All as per Item No. 153.00 above, but except bricks, complete all as specified and directed.
M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Dismantling posts or struts (RCC/PSC/steel or wood) embedded in concrete, masonry or earth (excluding taking out embedded portion), including removing concrete, etc., complete all as specified and directed.
Demolition of cement concrete of any description and in any position, not otherwise specifically provided for, complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded aggregate) in coping, steps, bed plates and similar works, finished even and smooth, complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete below ground level, complete all as specified and directed by the Engineer-in-Charge.
M&L for PCC (1:2:4) type B1 (using 12.5 mm graded aggregate) in levelling course under floors, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges
S&F in repairs, galvanised 2-strand steel barbed wire, 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing, straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings and provision of galvanised mild steel wire, staples or steel pins, complete all as specified. Note-Each line wire to be measured separately.
S&F in repairs, barbed razor type concertina coil, 9 SWG hot galvanised spring tensile wire (UTS 145–150 N/Sq mm) with zinc coating 250–300 g/sqm; diameter of coil when unstretched 600 mm; GI strip 0.50 mm thick × 19 mm wide, weight 1.625 kg/RM; hot-dip galvanised razor ribbon tape fixed with 1.66 mm thick GI clips (minimum 25 Nos/RM) and special nuts and bolts to hold two coils together, with extra parallel 10 gauge wire, complete all as specified and directed.
M&L for stone walling of random rubble, uncoursed, brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified and directed.
Extra over stone walling built in lime or sand stone, for hammer dressing to face stones, maximum depression from a straight edge not exceeding 40 mm; dressing of face beds and joints of random rubble walling, uncoursed or brought up to courses, complete all as specified and directed by the Engineer-in-Charge.
M&L for raised pointing in cement mortar 1:4 to RR masonry, uncoursed or brought up to courses, complete all as specified and directed by the Engineer-in-Charge.
M&L for roughening surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust etc., including taking down existing treatment, tiles and tar felt, complete all as specified and directed.
Demolition of unreinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landings, chajjas and similar suspended works, including disposal of unserviceable material within the premises to a suitable stacking location, at ground level, complete all as specified and directed.
M&L for cleaning and preparation of RCC roof surfaces and applying roof treatment as under: (a) Apply oil-based bituminous primer @ 200 g/sqm on prepared surface. (b) Apply blown type bitumen grade 85/25 (IS:702) @ 1.2 kg/sqm heated to 180 °C. (c) Provide and lay 4 mm thick APP modified torch-applied waterproofing membrane, weight ≥ 3.0 kg/sqm, reinforced, with minimum 10 cm overlaps and 15 cm end laps. (d) Finish surface with solar-reflective bituminous aluminium paint @ 100 g/sqm. APP membrane to be taken up 200 mm on vertical surfaces; edges sealed with sealant. Rainwater gutter portion finished in CM 1:4 to provide slope to outlets. Notes: (i) Net covered area shall be measured and paid (laps not included). (ii) Rate includes primer and SBR latex.
M&L for reinforced cement concrete (nominal mix) 1:2:4, Type B1 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like, complete all as specified and directed.
M&L for mild steel TMT bars, (CRS) 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends, binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed.
Formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping), rough finished, complete all as specified and directed.
M&L for injection grouting with cement slurry, cement : water = 1 : 2, including super plasticizer (Supercom-100 @ 250 ml/50 kg cement), mixed mechanically and pumped under 0.5 kg/cm² pressure until grout flows from adjacent nozzles, indicating complete filling of cracks/voids in walls and slabs, complete all as specified and directed.
M&L for injection grouting with low viscosity MONOPOL (3–5 cps) high molecular weight monomer, by pressure using mechanical injector gun with accessories, mixing components (A & B) by weight as per manufacturer’s instructions, pumping at 0.5–1.0 kg/cm² pressure until refusal at nozzles, in structural elements (beams and columns), @ 100 ml per nozzle, repeating as necessary, complete all as specified and directed.
M&L for 4 mm thick non-asbestos fibre cement building boards, fixed or laid/inserted to timber/GI/aluminium framework with screws, as in flat or ceiling surfaces, complete all as specified and directed.
Dismantling water tanks exceeding 500 litres but not exceeding 1000 litres capacity, including removing to store, complete all as specified and directed.
Dismantling water tanks exceeding 1000 litres but not exceeding 2000 litres capacity, including removing to store, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank, 1000 litre capacity, cylindrical vertical with closed top, hoisted and fixed in position including 20 mm PTMT high-pressure ball valve with epoxy-coated aluminium rod and high-density plastic ball (minimum weight 210 g), complete all as specified in SSR Part I.
S&F rotational moulded polyethylene water storage tank, 2000 litre capacity, cylindrical vertical with closed top, hoisted and fixed in position including 20 mm PTMT high-pressure ball valve with epoxy-coated aluminium rod and high-density plastic ball (minimum weight 210 g), complete all as specified in SSR Part I.
Disconnection existing tanks, setting aside (or lowering if required) for cleaning etc and hoisting and reconnecting and re-fixing in the same position capacity exc 500 Ltr and n.exc 1000 Ltr all as specified and directed.
Disconnection existing tanks, setting aside (or lowering if required) for cleaning etc and hoisting and reconnecting and re-fixing in the same position capacity exc 1000 Ltr and n.exc 2000 Ltr all as specified and directed.
Taking down PVC waste/rainwater pipes, any size or pattern, including all fittings, heads, shoes, bends, swan necks etc., complete all as specified and directed by Engineer-in-Charge.
Taking up or down existing GI water tubing and refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete with all fittings of 40/50 mm bore
Taking up or down existing GI water tubing, 15 mm bore, including all fittings, from walls, floors or ceilings, for refixing or removal, complete all as specified and directed.
Taking up or down existing GI water tubing, 20/25 mm bore, including all fittings, from walls, floors or ceilings, for refixing or removal, complete all as specified and directed.
S&F GI tubing, medium grade, 15 mm bore, with all fittings such as tees, bends, elbows, fixed to walls or ceilings with saddles/spacers, complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing, medium grade, 20 mm bore, with all fittings such as tees, bends, elbows, fixed to walls or ceilings with saddles/spacers, complete all as specified and directed by Engineer-in-Charge.
S & F 15 mm bore UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, ceiling etc or in floors etc, Complete all as specified and directed by Engineer-in-Charge.
S & F 20 mm bore UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, ceiling etc or in floors etc, Complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20mm (outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying infloors complete all as specified.
Supplying and laying of 25mm (outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying infloors complete all as specified.
Supplying and laying of 40mm (outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying infloors complete all as specified.
S&F in repair 25mm dia Gun-metal, globe or gate valves (ISI MARKED), with iron wheel head, screwed both ends for iron pipe and fixed
S&F in repair 40mm dia Gun-metal, globe or gate valves (ISI MARKED), with iron wheel head, screwed both ends for iron pipe and fixed
DiDisconnecting and refixing outdoor AC units, including refixing on plinth, connecting with existing pipes, wires and accessories, repairing or replacing damaged parts as required. (Note: plinth shall be measured and paid separately.)
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing Bldg Material exc 1.5 Km but n.exc 20 Km and depositing outside MoD land complete all specified and directed by Engr-in-Charge.
Material and labour for machine pressed precast concrete inter locking paver block any shape and size with grey cement and pigment conforming to IS-15658-2006 of 80mm thickness M40 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints and gently rolled with vibrator complete all as specified and directed by the Engr in charge.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power/bell) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge.
M&L for concealed point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall as per site requirement/metallic terminal boxes concealed in wall suitable for modular accessories with cover plate and frame including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including modular box and cover plate all as specified.Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green b) Make of wire : Polycab/ Havells/ Finolex/Plaza/Benlo c) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit/PVC Casing Capping. Note : - PVC Casing Capping will be used where PVC conduit not feasible at structural members only.
One light point controlled by one switch
One ceiling fan/wall fan/exhaust fan point controlled by one switch
One Bell point control by one 5A bell push switch
One 5 Amps switch socket combination on independent board
One 5A flush type switch socket point on same board
M & L for concealed point wiring in repair with FRLS PVC insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm size 1100 volts grade drawn through and including non metalic rigid PVC conduit not less than 25mm width with all accessories fixed on wall including FRLS PVC insulated, unsheathed multistranded copper onductor cable of size 2.5 sqmm as earth continuty conductor connecting to common earth dolly and PVC moulded box ISI marked for having the switches, switch sockets regulator etc complete all as specified for following:-
One 15A flush type switch socket point on independent board
M&L for concealed submain wiring in repair with 2 runs of 4 sqmm and 1 run of 4 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC conduit not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed.
M&L for concealed sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
S&F in repair LED recess mounted type fitting 36W 2'x2' CRCA LED (min 120 lumen/watt) Slim panel with recess mounting, powder coated white CRCA full glow LED panel including control gear and lamp complete all as directed and specified by Engr-in-Charge.
Supply and fixing in repair of LED 60W (min 120 lumen/watt) Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed by EIC.Make : CG/Bajaj/C&S
Supply and fixing in repair walll/surface mounted 20W LED (min 120 lumen/watt) batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge.
Supply and fixing of LED highbay light 200 W, (min 110 lumen/watt) 5700K complete all as specified and directed.
S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed.
Supply and fix in repair modular switch 1 way 16 Amps 1 module 240 volts flush type
S&F for modular fan regulator fan step regulator, 120W - 2 modular step type
Supply and fix in repair modular socket 6 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge.
Supply and fix in repair modular socket 16 Amps 2/3 pin 240 volts Ac combined 2 module all as specified and directed by Engr-in-Charge.
S & F moduler bell push 6A, 1 module all as specified and directed by EIC.
S&F Ding dong AC 230Volts single pole bell 50 Hz all as specified and directed.
M&L for taking down of Split AC/Window unit from existing postion & refixing the new position/location including additional accerssories as required, bressing of existing copper pipe with new copper pipe, leak testing, testing & commisssioning all as specified and directed by EIC.
Supply and fixing copper tubings of appropriate dia for suction line & for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing thugh pipe and making good distrubed surface completely.
S & F in repair 20 Amps Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB.make -Legrand Cat part no -507814,siemens ,GE
Disconnecting and taking down the fan and Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat white enamel paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, insulation class A for temperature rise, with BLDC motor, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking down the fan and Overhauling of exhaust fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust, rust and applying two coat gray paint over a coat of steel primer, assembling and refixing at same position complete all as specified.
Supply and fixing in repairs Exhaust fan, Heavy duty, steel body AC single phase, 230volts, 50Hz of size 380mm sweep,1400 rpm including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. .
Supply and fixing in repairs Exhaust fan, Heavy duty, steel body AC single phase, 230volts, 50Hz of size 300mm sweep along with louvers with and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing of wall mounted fan, 400 mm sweep, complete all as specified and directed.
S&F on replacement of hanger clamp assembly with down rod up to 3 feet for hanging of ceiling fan with nuts,bolts, washers & split pin complete all as specified & directed by EIC.
Supply and fix in repair ceiling rose surface bakelite three terminal of size 60x50 mm,240 Volts AC complete
S&F in replacement of steel sheet enclosure double door type IP54 IK09 protection DB SPN 8 way, 240 volts AC factory made, suitable for housing MCB SPN along with 200 Amps copper bus bar complete all as specified and directed
S&F in replacement steel sheet enclosure double door type IP54 IK09 protection DB SPN 12 way, 240 volts AC factory made, suitable for housing MCB SPN along with 200 Amps copper bus bar complete all as specified and directed
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 6 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed.
S & F in repair MCB SP 6 - 32 Amps, 10 KA Rupturing capacity
S & F in repair MCB SPN 40-63 Amps, 10 KA Rupturing capacity
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
M & L for 4mm GI wire earth continuity conductor or main earthing lead fixed to wall or buried in ground and fixed to panel/transformer alongwith 20mm gi pipe light grade for protection.
S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
S&F for Rigid non-metallic PVC conduit 40mm dia with complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
S & F in repair MCCB 3P 100 Amps,16KA,thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420015/Seimens/GE
Supply and install in replacement of instant geyser /heater type of capacity 25 Litrs BEE 5 star, 230 volts, AC, 50 Hz including PVC connection of size 15 mm dia & 450 mm long for hot water complete with both end. Make :- Havells/ Classic/ or equivalent approved by GE.
S & F in replacement decorative LED post tops lantern of capacity 40 watt fitting with die cast aluminium housing and powder coated top cover, PDC heat sink, opal PC diffuser, IP 65 and with system efficacy of 80 lm/W complete with all accessories and all as specified and directed by Engr-in-charge Make : Halonix cat part No. HLPT-04-40-CW or equivalent
Supply and fixing of touch free infrared hand dryer with minimum 1150 watt, single phase complete all as specified and directed.
Supply and fix ball brass high pressure with polythene float and fly nut of 25 mm dia complete screwed to iron or brass ferrule
Supply and fix gun metal gate valve, with iron wheel head screwed both ends for iron pipe of 25 mm bore incl provision of union nipples sockets etc.
Supply and fix GI tubes medium grade of 25 mm dia complete with all fittings (like; union, tee, bend, elbow, reducer, socket) to be fixed on wall and ceilings or laid in floors/trenches complete.
M & L for concealed point wiring in repair with FRLS PVC insulated unsheathed multi stranded copper conductor cable of 4.0 sqmm size 1100 volts grade drawn through and including suitable size PVC non metalic rigid conduit not less than 25mm width with all accessories fixed on wall including FRLS PVC insulated, unsheathed multistranded copper conductor cable 4.0 sqmm as earth continuty conductor, connecting to common earth dolly including required nos and size of modular box with cover plate frame in any module complete necessary electrical connections for each work station point comprising of 03 Nos. 5A and 01 No switch socket 15Amps complete all as directed.
S&F in repair FRP looping box 225x295x122mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 2-32 Amp and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed
Supply and fix in repair decorative Post top lantern 45 Watts includig fixing of suitable for 60mm OD pipe for the mounting, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC; provided with high voltage, open and short circuit protection and making good distrubed surfaces all as specified and directed with post top lantern parameters as follows:- system wattage 45 W, 6500K, IP protection = IP 65, PF≥ 0.90, Resistance to impact and corrosion. Glare free and better uniformity Milky version
S & F in replacement LED garden light 9W (min 120 lumen /watt) cylindrical shaped integral decorative LED bollard with opal acrylic diffuser and IP 65, 900mm height with all accessories includingn PCC foundation tapper plug, bolts, nuts, screws etc complete all as specified and directed by Engr-in-charge.
S&F in replacement of LED street light 120 W (min 120 lumen /watt)energy saving and envirment friendly light fitting with housed in pressure dia cast aluminium housing with sealed toughened glass cover, luminaires with IP 66 protection including all fixing accessories complete all as specified and directed by Engr-in-Charge.
S& F GI cable tray perforated type 2 mm thick of size 600x50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with0.71mm thick aluminium sheet cover, to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete etc all as directed
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note: The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S & F in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 8 Mtrs long top mounting on foundation complete with base plate including PCC foundation as per SSR provision and directed with 1500 mm long arms bracket, tapper plug, bolts, nuts and screws etc as specified complete including taking out existing RCC/damaged rusted MS pole with street light and street light bracket complete all as specified and directed by EIC. Make Bajaj
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil complete all as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm complete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
M&L for un-reinforced,precast concrete cable cover of size 250x150x40mm class LV type-I for cable protection all as specified and directed
Supply and fix in replacement GI arms bracket 30 degree bend, 1.5mtr long for mounting one in nos street light fitting including clamps / nut / bolts & washer to brace the same properly with duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed by the Engr-in-Charge.
S&F GI tubing light grade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed. Make : Jindal/Tata/Surya Prakash
Supply & Fixing in replacement with modular stepped type (5 step) electronic fan regulator, 2 module, 230 volts ISI marked compatible with BLDC ceiling fan 1200MM sweep and connecting up complete all as specified and directed Engr-in-Charge.
Supply, Installation, Testing & Commissioning of HI wall split Units Indoor/Outdoor complete with cordless remote control unit & with air ioniser and plasma filter for better indoor air quality with minimum 5 Star rating (as per latest label period) & EER 3.2 of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge.
Supply, laying, commissioning and testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm x 4 core including taking down existing cable complete all as specified and directed by Engr-in-charge
ROHIT CONSTRUCTION (BID ID -3491821)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_826792.xls
BOQ • 3.92 MB
8494.rar
Tender Documents • 3.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .