Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: BPE
Model: BPE 5KVA ONLINE UPS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 5KVA ONLINE UPS | L1 | Qualified | |
| 2 | L3₹1.2 L+₹7,083 (6.49%)Qualified Make: LUMINOUS
Model: LUMINOUS Online UPS 5KVA 1ST FLOOR F 05 PARKER SUITES NH 01 SECTOR 62 KUNDLI SONEPAT HARYANA 131028 SONEPAT SONIPAT HARYANA 131001 | SONIPAT | HARYANA | 131028 | Make: LUMINOUS
Model: LUMINOUS Online UPS 5KVA | L3 | Qualified | |
| 3 | L4₹1.2 L+₹10,543 (9.65%)Qualified Make: microtek
Model: MICROTEK i-MAX 5.0/ 5.5KVA/192V 248 HAZURI BAGH JAMMU JEWEL ROYAL APARTMENTS JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | Make: microtek
Model: MICROTEK i-MAX 5.0/ 5.5KVA/192V | L4 | Qualified | |
| 4 | L5₹1.2 L+₹10,783 (9.87%)Qualified Make: microtek
Model: MICROTEK 5KVA-120MINUTE-2YEAR C 432 AWANTIKA ROHINI PHASE 1 NEW DELHI 110085 NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: microtek
Model: MICROTEK 5KVA-120MINUTE-2YEAR | L5 | Qualified | |
| 5 | L6₹1.2 L+₹11,015 (10.1%)Qualified Make: Uniline
Model: UNILINE MAXIPOWER ONLINE UPS 5 KVA WITH 15 BATTERISES 26 AH OF OKAYA BABYAL ROAD AMBALA CANTT AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | Make: Uniline
Model: UNILINE MAXIPOWER ONLINE UPS 5 KVA WITH 15 BATTERISES 26 AH OF OKAYA | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Oct 2018, 9:00 pmClosed
Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 240 15
30
60
90
120
180
240 Minimum VAH (VAH) 8400 400-640000 1/4 Warranty for UPS (Years) 1 1
2
3
4
5 Movable trolly for Batteries With With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes * Indicators for mains presence
Battery charging and Yes * 2/4 discharging
Output Over Load
Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Linto George 151201
34 Wing
Air Force Station
Bhisiana 1 30 3/4
680863
GEM/2018/B/96472
Online UPS
30 days
Punjab; Bathinda
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 240 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 8400 400-640000 1/4 Warranty for UPS (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries With With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains presence | - | - | - |
| Battery charging and Yes * 2/4 discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Linto George 151201 | - | - | - |
| 34 Wing | - | - | - |
| Air Force Station | - | - | - |
| Bhisiana 1 30 3/4 | - | - | - |
Exempted
15 Oct 2018
16 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_680863.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .