Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.1 LAccepted-AOC 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹99.3 L+₹40.2 L (67.9%)Rejected-AOC | L2 | Rejected-AOC Being not Lowest | |
| 3 | L3₹1.0 Cr+₹42.1 L (71.3%)Rejected-AOC | L3 | Rejected-AOC Being not Lowest | |
| 4 | L4₹1.0 Cr+₹45.1 L (76.3%)Rejected-AOC NOT AVAILABLE | L4 | Rejected-AOC Being not Lowest | |
| 5 | L5₹1.2 Cr+₹58.6 L (99.2%)Rejected-AOC REGD OFFICE VILLAGE KHEJURI TEHSIL SIKANDARPUR DISTT BALLIA UTTAR PRADESH | BALLIA | UTTAR PRADESH | 277303 | L5 | Rejected-AOC Being not Lowest |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
27 Mar 2024, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI, PRAYAGRAJ-211012
BUILDING CONSTRUCTION
2023_MES_585345_4
87074/E8
Open Tender
Civil Works
Lump-sum
273 days
GORAKHPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) GORAKHPUR
₹1.1 L
Yes
17 Apr 2024
5 Mar 2024
29 Mar 2024
5 Mar 2024
27 Mar 2024
20 Mar 2024
5 Mar 2024 - 12 Mar 2024
Amount
Lump sum price worked out by the contractor as per showm on drawing for Building works as listed in Sch ‘A’ Part-I.
Lump sum price worked out by the contractor for Addn/Altn for opening of door as listed in Sch 'A' Part II.
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch 'A' Part III.
Lump sum price worked out by the contractor for Fire Fighting as listed in Sch 'A' Part IV.
Lump sum price worked out by the contractor for Road / Path / Hardstanding as listed in Sch 'A' Part V.
Lump sum price worked out by the contractor for Boundary Wall, Fencing and Gate as listed in Sch 'A' Part VI.
Lump sum price worked out by the contractor for Earth Work as listed in Sch ‘A’ Part VII.
Price item wise worked out by the Contractor for Schedule `A' Part-VI (rate against Srl No. 9.0 to 23.0 shall be quoted by the Contractor)
S&F LED light fittings 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED building security light fitting 60 Watt, 230 Volt AC, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal managment in multiple optics complet with IP 65/66 protection complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel connected to earthing test point all as specified including 15 mm dia GI tubing medium grade and necessary fitting for protection of GI wire including supplying and laying charcoal dust, common salt in alternate layer, PCC pit with 1:3:6 Type C1 (Using 20 mm graded stone aggregate) RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia plastering 15 mm thick in CM 1:6 externally upto 150 mm below ground level, GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work, and disposal of surplus soil complete all as specified and shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing and marking building Nos and writing test results on a 3.0 mm thick painted MS earth pit marking plate ( 200 mm x100 mm ) duly welded with a 450 mm long 10mm dia round MS rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site complete all as specified and directed.
Construction of brick masonary valve pit of size 900mm x 900mm x 900mm complete all as specified and shown on drawings.
Supply and installation Kirloskar 12.5 HP three hase Monoblock Pump, model-KDS-1348+ complete all as specified and directed.
Supply and installation mild steel jockey fire pump control panel, IP rating 66, working temperature 120 degree celsius complete all as specified and directed.
Supply and installation water pressure sendor complete all as specified and directed.
Supply, install, test and commissioning of electric motor driven Jockey pump set horizontal end suction centrifugal type confirming to IS:12469:1988 with CI casing ,bronze impeller and stain less steel shaft mounted on heavy duty bearing suitable for automatic operation with non over loading power characteristics for frequent start/stop operation of fire fighting complete for delivery of water at the rate of 180 LPM at 70 m head and running at 2850/2900 RPM so as to maintain the pressure 7.0 Kg / Sqcm with pressure gauge, squirrel cage induction motor suitable for 415 V, 3 Phase, 50 Hz complete with and including all accessories and common base plate of MS channel and foundation (RCC/PCC) all as per manufacture instruction/design and vibration resistant complete all as directed by Engineer-in-Charge.
Supply and fix cast iron foot valve (ISI marked) 100mm nominal bore complete with jointing material complete all as specified and directed.
Supply and fix cast iron foot valve (ISI marked) 80mm nominal bore complete with jointing material complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron earth strip 32x6mm as earth lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel connected to earthing test point all as specified including 15 mm dia GI tubing medium grade and necessary fitting for protection of GI wire including supplying and laying charcoal dust, common salt in alternate layer, PCC pit with 1:3:6 Type C1 (Using 20 mm graded stone aggregate) RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia plastering 15 mm thick in CM 1:6 externally upto 150 mm below ground level, GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work, and disposal of surplus soil complete all as specified and shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing and marking building Nos and writing test results on a 3.0 mm thick painted MS earth pit marking plate ( 200 mm x100 mm ) duly welded with a 450 mm long 10mm dia round MS rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site complete all as specified and directed.
S&F MCCB 100 Amp, 4 Pole, 16 KA with sheet metal enclosure complete all as specified and directed.
S&F sheet metal enclosure DBs, single pole and neutral, 4 way with 200 Amp rated bus bar, 240 Volt, double door complete all as specified and directed.
NEHA INFRASTRUCTURE & COMPANY
M/s GOURAB JYOTI GOGOI
SATYA CHANGMAI
M/s SKP CONSTRUCTION
M/S MANASEE
KULA PRASAD GOHAlN
PRADIP CHANGMAI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .