Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹42.2 L+₹16,909 (0.40%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹48.5 L+₹6.5 L (15.4%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | - | Rejected-Technical TENDER FEE NOT RECD |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Jan 2021, 6:00 pmClosed
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
REPAIR AND REPLACEMENT OF FIRE FIGHTING SYSTEM , MO AND MAINT OF E S,W S INSTALLATION AT NAVAL AVIATION ENCLAVE NAE SANTACRUZ
2020_MES_406934_1
8896/B
Open Tender
Civil Works
Item Rate
334 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹80,000
Yes
21 May 2021
24 Dec 2020
22 Jan 2021
24 Dec 2020
21 Jan 2021
7 Jan 2021
Amount
Outsourcing of services for electric supply installations 11/0.433 KV sub Station & stand by diesel Generator Sets comprising of transformer, AMF panels, APFC panels, HT VCBs, ACBs, LT Panels/FP Boxes, LT/HT UG Cables, lightning Arrestor, Earthing,metering equipments & batteries etc including routine maintenance, cleaning of equipments, Maintaining of daily records of electric supply and log books of DG sets with all parameters with stationery and including atending of electrical break downs and electrical repairs as directed with necessary expendable items and providing all types of tools and clamp meter, IR/ER tester, Earth rod, Hand Gloves, ladders etc and adopting necessary safety precautions in attending break downs, and electrical repairs, switching on/off street lights, top up of fuel as provided/stored by department and cleaning of equipments and surrounding area of installations in neat and presentable position by deploying Electrician (ITI Holder) - 01 in each shift of 08 hours duration required in two shifts in a day in all the days including sundays and holidays with arrangement of reliever duty at NAE Santacruz comprising of following shifts complete all as specified and directed :- Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs NOTE : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the trademen will be contractor's responsibility in consultation with MES/ users.
Overhauling and servicing through agency authorised by OEM of HT VCB, 11 KV, 800 Amps of make Siemens installed at NAE Santacruz including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gaskets, washers, panel heater, indicator bulbs and carry out any other repairs required at site to make the VCB fully functional, complete all as specified and directed.
Caliberation of relays of HT VCB by secondary and primary injection, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV parts of master relays complete all as specified and directed.
Overhauling of step down outdoor/indoor transformer 500 KVA 11/0.433 KV by disconnecting HT/LT terminals, decanning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, reassembling refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint after preparation of painted surfaces of transformer and testing and recommissioning on load etc, complete for the transformers of following rating (Filteration and dehydration of transformer oil, supply only transformer oil for topping up, supply only of HT & LT bushings shall be measured and paid separately under respective items)
Repairs and overhauling of Air Circuit Breaker (ACB) 3/4 pole, 415 Volt, upto 800 Amp with thermal magnetic release by replacement of worn out parts and cleaning the complete ACB and testing the same after repair for smooth functioning etc complete all as specified and directed.
Comprehensive maintenance of electrically operated travelling (EOT) crane of 05 MT, Span -46.60 mtr, SWL-5000 Kgs capacity, floor operated comprising of hoist motor, micro motor, long travel motor, cross travel motor, gear box, control panel and other connected accessories installed at NAE Santacruz
To carry out load Test of 5 MT Crane as per Manufacturer norms and provide a load test certificate by manufacturer all as specified.
M & L for painting 5 ton crane completely with two coats of golden yellow paint including preparation of existing surface by scrapping detoritied paint etc. all as directed by Engr-in-charge.
Repair, Maintenance & Servicing of DG Set 500 KVA Make- Greaves Power Genset Model No GPWII-500 complete including with B Check through OEM as per direction of Manufacturer as directed.
Supply and replacement of Greaves Max Therm Premium Engine Oil SAE15W40 Part No.123200198614 for DG set 500 KVA Make: Greaves Power Genset Model No.GPWII-500
Supply and replacement of Oil filter for DG set 500 KVA Make- Greaves Power Gense Model NoGPWII-500 complete
Supply and replacement of Fuel filter for DG set 500 KVA Make- Greaves Power Gense Model NoGPWII-500 complete
Supply and replacement of Radiator coolant for Greaves Diesel Engine Ready to use Premix Part No.141100195038 For DG Set 500 KVA Make: Greaves Power Genset Model No.GPWII-500 complete
Repair and maintenance of 75 HP fire service main pump multi stage having 2280 LPM at 80 Mtr head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100 HP diesel engine including servicing by replacing unserviceable items of gland packing , bearing and charging lubricants for smooth running including servicing of 75 HP diesel engine by replacing filters, lubricant oil including defective parts like coupling , oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tank to engine, battery leads and checking of charging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed.
Takig down unserviceable Fire fighting motor pump set of capacity 3 phase 100 HP disconnecting the all necessary electrical connections and dismantlng the pump side and replacing the worn out winding and connected items like bearings, bush and coupling and rubber coupling etc; and rewinding with super enameled copper wire of suitable guage including varnishing, reassembling and re-coupling with pump set, testing and painting with synthetic enameled paint after preparing the existing surface complete all as specified.
Repair and maintenance of 7.5 hp fire service jockey / booster pump multi stage having 180 LPM at 56 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 7.5 hp AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed. Location: Fire Pumphouse NAE Santacruz
Supply and fix in repair Smoke and Heat Multisensor detector complete all as specified and directed. Make- Apollo XP95 Model 55000-885
Supply and fix in repair Hooter Sounder Visual Indicator base complete all as specified and directed Make- Apollo Model- 45681-393
Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 02 ton of any make /type after disconnecting refrigerant pipes , drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda , checking and replacing the spares like relay, capacitors, thermostat, fan motor blades & blower and including servicing, overhauling and connecting of refrigerant pipe, drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed.
Supply only outdoor fan motor for split type air conditioner 2.0 ton capacity complete all as specified.
Supply only running capacitor 45 mfd for split type air conditioner 2.0 ton capacity complete all as specified
Supply only fan capacitor 4 mfd for outdoor unit for split type air conditioner 2.0 ton capacity complete all as specified.
Supply and fix addressable heat and smoke combination (acclimate) with stand base complete all as specified and directed.
Supply and installing testing and comissionning addressable manual call points(MCP) complete all as specified and directed.
Supply only contactor 32 Amp capacity, 440 volts, 50 HZ, AC Supply.
Supply only brake liner unit 4 inches suitable for 5 Ton EOT Crane.
Supply only brake liner unit 6 inches suitable for 5 Ton EOT Crane.
Supply and fixing of gun metal,Ball valves with iron wheel head,screwed both ends for iron pipes of 50 mm dia as specified and directed.
Repair /replacement of fire fiting Non return valve reflux type with bypass arrangement complete of size 150 mm dia bore pipe complete all as specified and directed
Comprehensive /Annual maintenance of CCTV System installed at NAE Santacruz and comprising of the following items as under :- Mini PTZ Dome cameras-4 Nos 16 Ch digital video recorder (DVR) - 01 No KBD digital keyboard/Joystick 24 Volt 2.1 Amp power supply -03 Nos Professiona CCTV monitor 21.5"-01 No 22" LED TV -01 Nos 2 TB Survelliance harddisk Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) spares will be charged on respective items.
Comprehensive Annual maintenance of fire alarm system installed at NAE Santacruz comprising of following items Main control panel -02 Nos Heat and smoke detector-150 Nos Mannual call point -12 Nos Hooter cum strobe- 20 Nos Note:- a) The complaint to be attended within 24 working hours (b) The equipment will be maintained on SITE incase ofor a major repair the equipment will be taken to the company workshop through return gate pass. (c) Spares will be charged on respective items.
Outsourcing of services for watersupply and fir fighting installations with pump sets 03 phase, 415 Volts, AC 50Hz comprising of pumping panel boards, control cables, metering equipment, earthings, star delta/DOL starters, etc including operating of valves, NRVs and connected pipe lines and routine maintenance, maintaining of dailyrecords of pumping installations with all parameters with stationery and including attending of water supply break downs as directed with necessary expendable items and providing of tools and clap meter IR/ER tester etc and adopting necessary safety precautions in attending break downs and cleaning of equipment and surrounding area of installations in neat and presentable position by deploying Fitter General Mechanic(FGM) ITI Holder - 01 No in each shift of 08 hours duration required in three shifts in a day round the clock(24 Hours ) in all the days including Sundays and Holidays with arrangement of reliever duty with following equipments/installations at NAE Santacruz comprising of following shifts complete all as specified and directed (a) Centrifugal pump set of make Kirloskar 05HP - 02 Nos (b) Fire fighting pump (AC driven) 2850 LPM (c) fire fighting pump ( diesel engine driven) 2280 LPM (d) Jockey pump 180 LPM (e) Fire Fighting piping network with hydrants and valves. Shift Timings (a) First Shift : 0600 hrs to 1400 hrs (b) Second Shift : 1400 hrs to 2200 hrs (c) Third Shift : 2200 hrs to 0600 hrs Note : Arrangement for deposition of necessary documents for issue of passes from MIAL/CASF/GVK authority for the tradesmen will be contractor's responsiblity in consultation with MES/ users.
Cleaning of underground sump by draining / pumping of water removing / sludge from bottom removing algaes and other growth from wall/floor/ roofs by high pressure cleaning method with rotary jets with approved detergent fubbing with vaccum cleaner sucking out all dirty water disinfecting the sump with chemical treatment (Chemical approved by FOA/WHO to make the sump totally clean bacteria free including painting MS steps manhole covers and suction pipe with synthetic enamel paint of 2000 gallons capacity at NAE Santacruz complete all as specificed and directed.
Material and labour for disconnecting & stopping of incoming/ washout and outgoing pipes by making suitable arrangements to avoid chocking of pipe line, removing total water from the tank & depositing the same in low laying areas all as directed cleaning the underground sump from in side by using high pressure cleaning method with rotary jet wilth approved detergent rubbing/ scrapping wall / floor /ceiling with wet vaccuum cleaner sucking out all dirty water and disinfecting the tank chemical treatment (chemical approved by FOA/WHO) to make sump totally cleaned and bacteria free including painting pit cover marking date of cleaning and next due and pipes (raising delivery wash out and over flow with sluice valves) including painting of pipe with two coats of synthetic enemel paint as per MES colour approved by EIC at site for RCC underground sump 25000 gallons at NAE Santacruz complete.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
M&L for river washed sand and screened dry for caushioning to ug cables in trenches below and around under ground cable for coushioning of cable in ducts including spreading and levelling complete.
Supply, Lay, Test & Commissioning cable in repairs LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable in repairs LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 150 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable in repairs LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 240 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable in repairs LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 400 Sqmm, 3.5 core complete all as specified.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and laying HDPE pipes of pressure rating 6 kgf/cm2 (PE-63 grade) of size 32 mm bore laid in trenches for passing of cable complete all as specified and directed.
Material and labour for GI tubes "Medium Grade" 50 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection complete all as specified and directed.
Supply and fixing in repairs LED post top lanterns fitting made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection 10/12 watt complete all as specified and directed.
Supply and fixing in repairs highly efficient high power multi LED flood fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge.
Supply and fix in repairs highly efficient high power LED street light fitting 100W with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP65 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting.
Supply and fix in repairs highly efficient high power 50 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting.
Supply and fixing in replacement pole mounting box FRP type of size 250mm x 175mm x 100 mm, 3 phase with locking arrangements including necessary nut, bolt and clamps of the flat iron of size 25mm x 4 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series and 3 phase connector 100Amp for incoming/outgoing cables with proper fixing arrangements on pole / wall complete all as specified and directed.
Supply and fixing in replacement pole mounting box FRP type of size 140mm x 140mm x 100 mm, 3 phase with locking arrangements including necessary nut, bolt and clamps of the flat iron of size 20mm x 3 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series and 3 phase connector 100Amp for incoming/outgoing cables with proper fixing arrangements on pole / wall Bajaj Model BOP-7030 or its equvalent in Crompton/Philips/Wipro, as approved by GE complete all as specified and directed.
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (02 Run & 01 Run of 1.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified.
Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, "J" type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) Quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling.
M&L for mild steel TMT bars 6 mm to 8mm dia cut to length, bent to shape required, stirrups, spaces and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed
M&L for RCC type B-1, 1:2:4 (nominal mix) using 20 mm graded stone aggregate as in footing, columns, post, pillars, piers, wall of culverts, suspended slabs, edges and struts etc complete all as specified and directed
M&L for form work to sides of concrete footings, columns, posts, pillars, piers, edges and struts of rectangular or triangular shape for rough finished flat concretesurface complete all as specified and directed
Supply & fix of Street light control console made out of 2mm thick MH Sheet and paineted with powder coated paint suitable for and including the following items prewired complete, dimantling of existing unserviceable MCCB/MCB and reconnecting the UG cables in new control console by replacing cable glands and lugs all as specified and directed. a. Programmable electronic timer with one change over of capacity 16 Amps Make Indo-Asian cat no TDA 43110 - 1 No b. Three pole contactor 70 Amps, 415 Volt Model No MNX 70 - 1 No c. Surface mounted 16 Amps modular type 2 Way switch with box complete - 1 No d. MCCB 4 pole 100 Amps with breaking capacity 25 KA adjustable type with extended terminals - 1 No
Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 120W , power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete painting with two coats synthetic enamel paint over a coat of red oxide complete dismantling existing unserviceable high bay fittings all as specified and directed. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
M & L prepration of old exposed surface of garden light pole 1.5/ 2.5/5 meter long applying two coats of aluminium paint over a coat of anticorrosive paint including painting to bottom of pole complete all as specified and directed.
Servicing of complete solar battery 100AH 12V including cleaning the terminals and replacing unserviceable brass battery clamps and toping up of distilled water including cleaning of solar pannels on 5 mtr height pole/roof top solar light fittings/pole complete all as specified and directed.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual pipe Technology, each of 3 Meter long with Quter Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120mm micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic Non Corresive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circut current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accrediated laborotory. Make: Fast Electrode or equivalent as approved by the GE. Note:- (i) The contractor shall procure the above materials either directly from the manufacturer (s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to included the above element also.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 83115.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
cooltech engineering services
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .