EXECUTIVE ENGINEER
Room 602 BSNL Bhavan Adarsh Nagar Hyderabad
Attending to LT break down and maintenance of LT service connected sites under Sr. GM (Area - II) of HTD for the year 2023-24.
2023_BSNL_175301_1
49/BEDH-II/2023-24
Open Tender
Electrical Works
Item Rate
180 days
HYDERABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL HYDERABAD
₹6,305
Yes
6 Dec 2023
22 Nov 2023
1 Dec 2023
22 Nov 2023
30 Nov 2023
22 Nov 2023
Amount
Attending of emergency breakdown calls from the quarters/ TE bldgs, related to power supply/ water supply pumps/ Compound lights etc, rectifying of fault, disconnecting of faulty/ burnt electrical accessories and restoration of power supply in panel/ DB to pump set by making temporary connections wherever necessary etc., complete as required.
Supplying and fixing of following electrical accessories suitable for operation on 230volts, 1 phase, 50Hz AC supply including providing interconnections etc as required. (a) 5A 3pin top
(b) 18/20 W LED tube light
(c) 36watts Led street light
(d) 5A sockets (Screw type)
(e) 5A switches (Screw type)
(f) 15A socket with hylam sheet
(g) 10" x 8" hylam sheet 2mm thick
(h) 12" x 10" hylam sheet 2mm thick
(i) 6A SP MCB
(j) 32A SPN MCB
(k) 63A 4P isolator
(l) Ceiling fan regulators step type/ dimmer socket type
(m) PVC Angle Holders
(n) PVC Ceiling rose
(o) Calling Bell
(p) 15A power plug with PVC box
(q) 63A HRC fuses
(r) 63A kit kat fuse 1 set (3Nos) with 63amps neutral link
(s) 100A kit kat fuse 1 set (3Nos) with 100 amps neutral link
(t) Repair of DOL starter
(u) New motor starter 5HP capacity with OL protection, capacitor, SPP, voltmeter, ammeter (Make: GELCO)
Supplying and fixing of following plumbling accessories suitable for the existing motors etc. (a) 40mm dia GI bends
(b) 40mm dia gi 4" nipple
(c) 40mm dia GI 12" nipple
(d) 50mm CPVC pipe (Make: Ashirwad / Sudhakar)
(e) 50mm dia brass foot valve (make: Zoloto / Leader / SS )
(f) 50mm dia 'L' bend CPVC (Make: Ashirwad / Sudhakar)
(g) 50mm dia MABT (Make: Ashirwad / Sudhakar)
(h) 50mm dia coupling CPVC (Make: Ashirwad / Sudhakar)
Repairing of ceiling fan/ exhaust including rewinding and replacement of bearings capacitor and refixing the fan etc., as required.
Laying of recovered cable size upto 95sq.mm on surface of wall including providing clamps making good etc
Supplying and laying of 2 x 16 sqmm weather proof aluminium wire for extending power supply to the pump room panel including testing providing interconnections etc as required.
Supplying and laying of 2 x 6 sqmm weather proof aluminium wire for extending power supply to the pump room panel including testing providing interconnections etc as required.
Supplying and laying of 2x1.5 sqmm copper flexible wire for extending power supply from pole box to street light fitting including testing providing interconnections etc as required.
Checking of power supply in the compound lighting pole box with lamp from pole to pole, attending to minor falults etc as required (for 23 poles)
Supplying and fixing of out door type with rain shade, canopy MS Box suitable for mounting the 100A kit kat fuses, neutral link with locking arrangment etc.,
Dismantling and re-fixing of existing fuses, lightning arrester and capacitor box including removing of cable connections and testing etc.,
Dismantling and re-fixing of existing CT operated meter box including removing of incomming and out going cables connections and testing etc.
Shifting of change over switch with box from BSNL Bhawan to Karwan TE including fixing the same in suitable location as per engineer incharge instructions.
Removing and re installation of existing 30 KVA AVR including relaying of cable providing inter connections etc
Removing and refixing of fire alarm panel including re-routing the cable etc, providing interconnections etc.
Removing of exisiting LT Panel including removing of input and out put cables, earthing stip, refixing the same at new location etc.
Removing of lighting DB, DC DB, 63 A TPN Switch Box, with conduits wiring, 3No 18" exhaust fans, celing fans 2 no, etc
Removing of service cable from pole to meter box of size 4x16 sq mm. AUG cable
Supplying and making of following end terminations with brass compression glands, and lugs as required (a) 4x16 sq mm
(b) 3.5x25 sq mm
Supplying and fixing of 4way MS encloser along with fixing of existing isolator with connecting of existing power plant cable etc
Removing and re-fixing of existing earth bus bar from the surface of wall along with suitable insulators etc.,
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required a) 3 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Supplying and laying of 25x5 mm thick GI Strip from earth pits to busbar etc
Supplying and laying of 8SWG GI wire for loop earthing.
Disconnecting the power cable of size 3.5x95 sqmm from the alternator, removing the cable from the control panel and MV panel to the change over switch etc.,
Supplying and crimping of 16Sqmm lugs for the exisitng 4 core aluminium cable, providing insulation tape etc as required.
Dismantling of the faulty centrifugal pump set, removing the foundation bolts, packing etc, hiring vehicle for shifting the same to the workshop, shifting back to the site, fixing the new gaskets, foundation bolts, reconnecting the pipe lines etc.,
Rewinding the existing 5HP motor with enamelled copper wire, removing all the burnt copper wires, providing insulating papers in between, providing varnish/ insulation coating on the new winding, oven heating the stator, fixing the same, providing new bearings, greasing etc., checking the shaft/ rotor part for any bends and making good the same if required etc
Lifting of submersible pumpset along with GI/ HDPE pipe, submersible cable, water level guard wire by using necessary tripod / lifting machine, suitable tools, hiring labour, disconnecting the submersible wire, level guard wire from the existing GI/ HDPE pipe, shifting the GI/HDPE pipe at suitable place as instructed by the Engineer in charge.
V S ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .