Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC accept | |
| 2 | L2₹37.8 L+₹17,598.63 (0.47%)Accepted-AOC | L2 | Accepted-AOC accept | |
| 3 | L3₹43.4 L+₹5.8 L (15.3%)Accepted-AOC | L3 | Accepted-AOC accept | |
| 4 | L4₹54.4 L+₹16.7 L (44.4%)Accepted-AOC | L4 | Accepted-AOC accept | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹31.8 L
EMD Value
₹55,130
Closing Date
24 Jun 2022, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Bhoranj
SH Providing, Laying , Jointing and testing of GMS pipe 65 mm dia and 80 mm dia for Rising main and Supply and errection of Pumping Machinery alongwith allied accessories for Booster , 1st and OHSR Stage)
2022_HPIPH_61857_1
EE.BHJ.tender-22-1871-1931 DT 17-06-2022
Open Tender
Civil Works
Item Rate
180 days
Bhoranj
Please refer Tender documents.
6 documents required · 6 mandatory
₹400
Executive Engineer Jal Shakti Division Bhoranj
₹55,130
Yes
16 Nov 2022
18 Jun 2022
25 Jun 2022
18 Jun 2022
24 Jun 2022
18 Jun 2022
Amount
Excavation in foundation, trenches for pipes & pits upto all depth etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming & dressing of sides, leveling of beds to correct grade including shoring / struting, planking, timbering & dewatering wherever required stacking the useable/ unuseable material/soil seperately & after laying, jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposited layer by ramming & watering and then disposing of all surplus excavated soil/unuseable material as directed within all leads& lifts including restoration of un-metalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads & lifts as per direction of the Engineer-in-Charge.and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returning the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as per direction and to the entire satisfaction of Engineer- in- charge up to all leads and lifts.
Providing laying jointing & testing in trenches of Galvanised mild steel electrically resistance welded edge flanged/butt welded pipe conform to IS/ISO 3183-2007-L210 of thickness 4.80mm of below mentioned grades in item as per dimension wt$ test pressure mentioned therein code (mill tolerance to be restricted with +-3%) on random, length of 4-7m excluding cost of bend only 10% joints shall be flanged joint and remaining shall be welded joints and welding of pipes will be down as per IS:816-1969 with elctrodes as per IS 814-1991 of make Adwani/ESAB. The laying jointing of pipe should conform to IS 5822-1994. The pipes and specials shall have out side wrapping with galvanised as per BIS- 4736 the galvanisation is done by the manufacturer/ firm itself complete in all respect:(i) 80mm dia, 4.80mm Thick.
Laying, jointing and testing of galvanised miled steel GMS with bavelled edge flanged/Butt. welded pipes as per IS:1239-2004 (Part-I), as per dimensions, class and dia mentioned below in random length of 6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. (earth work in trenches flanged joints and Butt welded joints to be measured and paid for separately)
GMS pipe 80 mm dia Heavy class with wall thickness of 4.80mm
GMS pipe 80 mm dia medium class with wall thickness of 4.00 mm
GMS pipe 65 mm dia Heavy class with wall thickness of 4.50 mm
Providing welding and fixing of MS flanges @5% of MS flange and 95% of butt welded joints, conforming to following tables as per IS: 6392-1971 (Latest with upto date amendments) and welding of MS flanges with GMS/MSERW pipes in three layers on both faces i.e two layer on outer faces and one layer on inner face to make the joint leak proof (The cost of providing and laying of GMS pipes to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1967 and required number of nuts and bolts conforming to IS: 1364. the thickness of gasket not less than 3.00 mm conforming to IS: 2712-1998. The work shall be done as per entire satisfaction of Engineer in charge
Booster Stage :
GMS pipe 80mm dia Wall thickness.4.00 mm (Table-5).
Ist Stage :
GMS pipe 80mm dia Wall thickness. 4.40mm (Table-28) 0/0 to RD 660
GMS pipe 80mm dia Wall thickness. 4.80mm (Table-28) 660 to RD 1620
GMS pipe 80mm dia Wall thickness. 4.00mm (Table-17) 1620 to RD 2640
GMS pipe 80mm dia Wall thickness. 4.00mm (Table-5)2640 to RD 3150
To OHSR
GMS pipe 65mm dia of wall thickness 4.50mm (Table-28) RD 0/0 to RD 300
GMS pipe 65mm dia of wall thickness 4.50mm (Table-17) RD 300 to RD 1080
GMS pipe 65mm dia of wall thickness 4.50mm (Table-5) RD 1080 to RD 1600
Providing Circumferencial Butt welded joints by electrical arc welding to below mentioned dia and wall thickness GMS/MSERW pipe welded in requisit (Minimum three)number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore)-CITOJET/ESAB make, conforming to IS: 814-1967, at site of work complete in all respects, including manual/machanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer in charge.
(i)80 mm dia
(i)65 mm dia
Supply of submersible pumping set of KSB /Calama /Kirloskar/SU approved make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per IS 8034-1976 latest suitable for clear water having grease packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 of reputed make conforming to BIS 9238-1979 latest with upto date amendments, totally dust and water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps , cable clips and depth gauge etc. and suitable for operation on data given below:-
SITE CONDITIONS:-
Discharge (Q) 4.04 Lps for the pump
Total head in Mts. 16.79 meters.
(a) LWL in sump well (h) 653.00 mtrs.
(b) Shaft level : 650.00mtrs.
( c) Level at discharge point 665.00 mtrs.
(d) Suction lift : 2.769 mtrs.
(e) Residual head : 3.00 mtrs.
(f) Static head : 15.00 mtrs.
Rising Main
(a) Length 45.00 mtrs.
( b) Dia 80mm dia.
pumping hours 16 hours.
Altitude of installation above MSL 520.00 mtrs.
Charactrstic of water
(a) Temperature : 20 degree centigrade
(b) Ambient temperature
Operating frequency
( c) Turbiduty Up to 50 PPM
Alkalanity
(e) Size of the solids
(f) Other
Supplying and fixing of prefabricated control panel consisting of Ampere Meter, Voltmeter, OCB/MCB /MCCB, ON/OFF push button, Circuit breaker, Voltage monitor relay, Power factor meter, Frequency meter, Bus bar chamber, Change Over Switch/ ICTP main switch with HRC fuses and other accessories, Capacitor, Strarter (Direct on line/ Star delta /Auto transformer), Phase Preventor, Hour run meter and other accessories suitable for pumping machinery under item No. 6 as per technical specification sheet attached complete in all respect. =1 No.
Supply of Kirloskar/leader/KSB make dia. cast iron (class PN. 1.00 ) double flanged sluice valve having size one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :780-1984 (Part I) = 2 Nos.
Supply of Kirloskar/leader/KSB make dia. cast iron (class PN. 1.00 ) double flanged ( swing check type) reflux valve having bye pass arrangement and having one dia. Higher than pump size to delivery of pump and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per BIS-5312-1984. (Part-I). = 2 Nos.
Supply of Leader /Kirloskar/KSB make 80 mm dia. cast iron class PN. 1.00 double flanged (swing check type) reflux valve having bye pass arrangement and size equal to dia of rising i.e. 80mm for withstanding nominal seat pressure of 10.20 Kg/Cm 2 as per BIS:5312-1984(part-1). =1 No.
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay /Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a) On supply side of 3½ core coper cable of suitable size ( From HPSEB Meter to Switch & Starter). = 10 Mtr.
b) On motor side 3 core flat joint less copper cable of suitable size ( From Switch & Starter to Motor) pump installed in the P/well. = 20 Mtr.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg / Bourden / Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.= 2 Nos.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of = 1 Job. a) Suction Pipe XXX = to be specified by the Tenderer b) Delivery pipe XXX = to be specified by the Tenderer c) Common header = 80 mm dia NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. Job.
Installation of all the above items S. No. 6 to 14 complete in all respect to the entire satisfaction of the Engineer-in-charge. Job.
Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump recommended such as Mather & Platt/KSB /Kirloskar /Approved make as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characterstics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage SPDP (screen protected drip proof) or TEFC (Totally enclosed fan cooled) induction motor of standard make such as Kirloskar/ Crompton/ NGEF/KSB /Jyoti and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1980 with up to date amendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc and should meet the following requirement.
SITE CONDITIONS:-
Discharge (Q) 4.57 Lps for the pump
Total head in Mts. 249.62 meters.
(a) LWL in sump well (h) 653.00 mtrs.
(b) Shaft level : 650.00mtrs.
( c) Level at discharge point 665.00 mtrs.
(d) Suction lift : 2.769 mtrs.
(e) Residual head : 3.00 mtrs.
(f) Static head : 15.00 mtrs.
Rising Main
(a) Length 3150.00 mtrs.
( b) Dia 80mm dia.
pumping hours 16 hours.
Altitude of installation above MSL 520.00 mtrs.
Charactrstic of water
(a) Temperature : 20 degree centigrade
(b) Ambient temperature
Operating frequency
( c) Turbiduty Up to 50 PPM
Alkalanity
(e) Size of the solids
(f) Other
Supplying and fixing of prefabricated control panel consisting of Ampere Meter, Voltmeter, OCB/MCB/MCCB, ON/OFF push button, Circuit breaker, Voltage monitor relay, Power factor meter, Frequency meter, Bus bar chamber, Change oevr switch / ICTP main switch with HRC fuses and other accessories, Capacitor, Strarter (Direct on line/ Star delta /Auto transformer), Phase Preventor, Hour run meter and other accessories suitable for pumping machinery under item No. 21 as per technical specification sheet attached complete in all respect. = 1 Nos.
Supplying and fixing of Kirloskar/Leader/KSB make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe Class PN1.0 provided with hand wheel/Cast iron Cap= . 2 Nos.
Supplying and fixing of Kirloskar/Fourcess/Gled/BHEL /Leader /KSB make of suitable size cast steel double flanged sluice valve having size one step higher to delivery of pump and capable of with standing nominal seat pressure of 52 Kg/CM^2 class ASA -300 conforming to BIS1414 = 2 Nos
Supplying and fixing of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader/KSB make of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 52 Kg/CM^2 class ASA-300. conforming to BIS 1868 = 2 Nos
Supply and fixing of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main ie. 80mm for withstanding nominal seat pressure of 52Kg/CM^2 of Class ASA 300. conforming to BIS 1868 = 1 No.
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay /Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a) On supply side of 3½ core coper cable of suitable size ( From HPSEB Meter to Switch & Starter). = 10 Mtr.
b) On motor side 3 core flat joint less copper cable of suitable size ( From Switch & Starter to Motor) pump installed in the P/well. = 20 Mtr.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg / Bourden / Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. = 2 Nos.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of = 1 Job a) Suction Pipe XXX = to be specified by the Tenderer b) Delivery pipe XXX = to be specified by the Tenderer c) Common header = 80 mm dia NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. = 1 Job.
Installation of all the above items S. No. 16 to 25 complete in all respect to the entire satisfaction of the Engineer-in-charge.
Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double/ multistage centrifugal pump of recommended such as Mather & Platt/KSB /Kirloskar as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear water for under mentioned characterstics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage SPDP (screen protected drip proof) or TEFC (Totally enclosed fan cooled) induction motor of standard make such as Kirloskar/ Crompton/ NGEF/KSB /ABB /BHEL/GEC/Seimens/Jyoti and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/ second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excessof the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1980 with up to date amendments read with IS:900-1972. It should include cost of bearing nuts, bolts and pointing etc and should meet the following requirement.
Discahrge (Q) : - 3.50 LPSor 12.60 Cum/hour
Total dynamic head : Mtr
(a) LWL in sump well (h) : 660.00 Mtr
(b) Shaft level : 660.00 Mtr
(c ) Level at discahrge point : 748.00 Mtr
(d) Suction lift : 0.50 Mtr
(e) Residual head : 3.00 Mtr.
(f) Static head : 88 Mtr.
(i) Rising Main :
(a) Length 1600 Mtr.
(b) Dia. : 65 mm
(iv) Pumping Hours : 8 Hours
(v) Altitude of installation above MSL :
(vi) Characteristics of water :
(a) Temperature : 0 C
(b) Ambient temperature 0 C
(c ) Turbidityupto 50 PPm
(d) Alkalinity Mg/Ca Co3
(e) Size of the solids mm
(f) Other
Supplying and fixing of prefabricated control panel consisting of Ampere Meter, Voltmeter, OCB/MCB/MCCB, ON/OFF push button, Circuit breaker, Voltage monitor relay, Power factor meter, Frequency meter, Bus bar chamber, Change oevr switch / ICTP main switch with HRC fuses and other accessories, Capacitor, Strarter (Direct on line/ Star delta /Auto transformer), Phase Preventor, Hour run meter and other accessories suitable for pumping machinery under item No. 32 as per technical specification sheet attached complete in all respect. = 1 No.
Supplying and fixing of Kirloskar/Leader/KSB make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe Class PN1.0 provided with hand wheel/Cast iron Cap. = 2 No.s
Supplying and fixing of Kirloskar/Fourcess/Gled/BHEL /Leader /KSB make of suitable size cast steel double flanged sluice valve having size one step higher to delivery of pump and capable of with standing nominal seat pressure of 21 Kg/CM^2 Class ASA -150 conforming to BIS1414 = 2 Nos.
Supplying and fixing of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader/KSB make of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 21 Kg/CM^2 Class ASA-150. conforming to BIS 1868 = 2 Nos.
Supply and fixing of Kirloskar/Kilburn/IVC/Fourcess/Gled/BHEL/Leader of suitable size cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main ie. 65mm for withstanding nominal seat pressure of 21 Kg/CM^2 of Class ASA 150. conforming to BIS 1868 = 1 No.
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay /Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
a) On supply side of 3½ core coper cable of suitable size ( From HPSEB Meter to Switch & Starter). = 10 Mtr.
b) On motor side 3 core flat joint less copper cable of suitable size ( From Switch & Starter to Motor) pump installed in the P/well. = 20 Mtr.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg / Bourden / Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. = 2 Nos.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of = 1 Job. a) Suction Pipe XXX = to be specified by the Tenderer b) Delivery pipe XXX = to be specified by the Tenderer c) Common header = 65 mm dia NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s. = 1 Job.
Installation of all the above items S. No. 27 to 36 complete in all respect to the entire satisfaction of the Engineer-in-charge. =2 Job.
Sanat Sharma
M/S MEERAN UDYOG
SB Trading company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .