Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.4 L+₹39,344 (3.03%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹15.8 L
EMD Value
₹31,500
Closing Date
9 Mar 2021, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
PROVN OF CERTAIN SANCTION RW AND SPECIAL REPAIR WORK IN THE AREA OF AGE B/R-II UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
2021_MES_420549_1
GE SGNR/ TOK-50 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
E Class a (i) and for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹31,500
Yes
16 Mar 2021
9 Feb 2021
11 Mar 2021
9 Feb 2021
9 Mar 2021
16 Feb 2021
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Surface dressing n. exc. 15 cm deep in soft/loose soil and watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L PCC 1:3:6 type C-1(20 mm graded aggregate) for filling of pressed steel frame and hold fast etc. complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:3:6) type C-2, (40 mm graded stone aggregate) as in foundation of posts and struts complete all as specified and directed by Engineer - in - Charge
M&L cement concrete 1:5:10, Type E-2 (40 mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M & L for PCC 1:2:4 Type B –1 (20mm graded stone aggregate)as in RCC pit cover, chajja, kitchen slab etc for kerb stone and similar works with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in CM 1:4 with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L for Providing precast cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone wallin). corbels, brackets etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM (1:4) complete with joints to match complete all as specified and directed by Engineer - in - Charge
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 but except bricks complete all as specified and directed by Engineer - in - Charge.
Cutting holes in brick (n. exc. Half brick) walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engineer - in - Charge.
M&L 20mm thick Granite (of any type) (table rubbed and polished) work in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed by Engr-in-charge.
S & F Second class hard wood factory made wire glazed and skeleton window shutters, 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing gauze/wire cloth, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer - in - Charge.
S & F 35mm thick,Second class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames (without taking off shutters from the frame) n. exc.1.5 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames (without taking off shutters from the frame) exc. 1.5 sqm and n. exc.4 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down shutters of any description exc. 1 Sqm but n.exc 2 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down steel window or ventilator of any type complete all as specified and directed by Engineer - in - Charge.
S & F alluminium anodised barrel tower bolts 150mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S & F alluminium anodised barrel tower bolts 125mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S&F 300mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. complete all as specified and directed by Engineer - in - Charge.
S & F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engineer - in - Charge.
S&F in repair 100 mm hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-charge.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
S & F Continuous (piano) hinges, mild steel, bright finish or electro galvanised Width of flaps (when open) in 30mm complete all as specified and directed by Engineer - in - Charge.
S&F 10 mm dia MS round bar for fixing in steel window with complete accessory complete all as specified and directed by Engineer-in-charge.
S&F mild steel work i.e. angle iron/ flat iron 40x6 mm as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
S&F mild steel flat iron 25x6 mm as in hold fast conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
S&F 100 mm longmild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 10 mm complete all as specified and directed by Engineer - in - Charge.
M&L for TMT bars 8 to 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in - Charge.
S&F 10 mm dia MS round bar for fixing of chain link fencing with post complete all as specifies and directedby Engineer - in - Charge.
M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge.
Fixing only of chain link fencing including line wires, any mesh size and type to any type of satanderds, rails, straining bolts etc including binding wire complete all as specifed and directed by engineer-in-charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer - in - Charge.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay with glazing bars, complete all as specified and directed by Engineer - in - Charge.
M&L for pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer - in - Charge.
Supply only chain link fencing galvanised mild steel hot dipped(IS -2721) of 4 mm dia of mesh size 100x100 mm complete all as specified and directed by Engineer - in - Charge. Note:- The weight of chain link fencing shall be ascertained by BOO as directed by GE and payment shall be paid accordingly BOO duly countersigned by GE shall be encloused with final bill.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including fittings complete all as specified and directed by Engineer-in-charge.
S&F in repair , Prelaminated particle board,19 mm thick interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge.
M & L for 20-25 mm thick machine cut kota stone slab flooring laid over and including 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 20-25 mm thick machine cut kota stone slab as in vertical surfces such as skirting, dados etc, laid over and including 10 mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C –1 (20mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge.
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 100mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 40 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for virified tiles light shade 10mm thick (square / rectangular) area of each tile n. exc 0.36 Sqm in floors etc. laid over and including 15 mm thick screed bed in CM 1:6, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles interior grade, of size 450x300x8 mm thick as on vertical surfaces like dados or skirting laid over and including 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises,complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick or concreate wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. complete complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 5 mm thick rendering in CM 1:3 on ceiling surfces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or un-plastered surfaces of ceiling and applying two coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, over a coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or un-plastered surfaces of walls by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying one coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or un-plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil emulsion distemper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of primer complete all as specified and directed by Engineer-in-Charge.
S & F 4mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-charge.Note; Aluminium snap beading shall be paid separately.
S & F 4mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in suqares n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer - in - Charge
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge
Taking down 15 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Fixing only Galvanised steel water tubing 15mm bore with new fitting including cutting chases to brick wall /ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 94 shall be re-used.
Taking down 20 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Fixing only Galvanised steel water tubing 20mm bore with new fitting including cutting chases to brick wall /ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 94 shall be re-used.
Taking down 25 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Fixing only Galvanised steel water tubing 25mm bore with new fitting including cutting chases to brick wall /ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 94 shall be re-used.
Dismantling and taking down water tank of capacity exc. 250 Litre but n. exc. 500 litre capacity complete all as specified and directed by Engineer - in - Charge.
S&F rotational moulded white colour polyethylene water storage tank 500 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having three layres )
S & F in repairs, 15mm bib tap cast copper alloy,fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. Make:- Parryware cat part no-G4636A1, Prayag cat part No- 8550, CREA cat part No. -F1005501
S&F in repairs, 15mm bore stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm bore stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 25 mm bore stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer - in - Charge.Note:- (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
S&F grating doom 100 mm dia of PTMT complete all as specified and directed by Engineer-in-Charge. Note:- Minimum weight 25gms
S & F CP towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge
S&F PVC connections 15mm size with PTMT nut of length 600mm complete all as specified and directed by Engineer-in-Charge.
S&F 100mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 75mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 100mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 100mm bore cast iron Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) pipes single socked in any length with rubber ring joints,laid in trenches or in floors all as specified and directed by Engr-in-charge.
M & L for PCC 1:3:6 type C –2 bed to drain pipes 150 mm including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer - in - Charge.
M&L for Salt - glazed stone ware drain pipes 150mm bore laid in trenches and jointed complete all as specified and directed by Engineer - in - Charge
S&F in repairs , chromium plated shower rose of size 125mm with or without shivel joints including fixing to pipe or union complete all as specified and directed by Engineer - in - Charge. Make: Parryware cat part no-T9808A1, Prayag cat part No- BS-73, Jaguar cat part no - EOS-542A
S&F in repair vitreous china wash down water closet pan (Pedstal pattern) white excluding flushing cistern & flush pipe but including seat cover complete all as specified and directed by Engineer - in - Charge.
S&F in repair water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests and CI 'P' trap and proper connecting to flushing cistern complete all as specified and directed by Engineer-in-charge.
S&F 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 32mm dia and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
S&F vitreous china wash hand basin counter shank with green/black granite slab to be cut and polished at site as per requirement white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge. (Note:- Granite shall be measured and paid seperately)
S&F stainless steel soap dish 160x160x90 mm fixed with screws complete all as specified and directed by Engineer - in - Charge
Demoliton of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer - in - Charge
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer - in - Charge
Dismantling timber scantlings 40 sq. cm and over in section, framed work in any position complete all as specified and directed by Engineer - in - Charge.
Demolition and breaking up 150 mm bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed by Engineer - in - Charge
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer - in - Charge
Dismantling brick tiles or terracing tiles, single layer on roof complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) .complete all as specified and directed by Engineer - in - Charge
S&F heat resistance tiles of size 300 x 300 x 10 mm thick on roof slab of any colour approved over and laid including 15 mm thick in CM 1:4 technicial specification of roof tiles shall be as per IS 4457:2007 complete all as specified and directed by Engineer - in - Charge. Make :- Johnson endura, kajaria, orient
S&F MS handle (left/right) for fixing in steel window with complete accessory complete all as specified and directed by Engineer - in - Charge
M&L for water proofing treatment to RCC sunken portion as specified below and as directed by Engineer-in-charge:- (a) Cleaning the surface with wire brush / coir brush, removing loose material like dust particles dirt etc and fixing 25mm bore dia GI Pipe minimum length 450mm as a spout pipe (b) M&L 15mm thick plaster in CM 1:3 with WPC on floor & raised vertical surface with making proper slope towards spout pipe (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surfaces. (e) Provision of glass fibre mesh of 2x2 mm immidiately on above coating (f) Apply second coat of two component modified polymer coating after 72 hours (g) Laying concrete 1:4:8 over the coating as per requirement (h) Joining the sanitary pipe with non shrink cementatiuos grout (k) Complete the treatment to be carried out by authorised applicator of water proofing manufacturer Make :- Dr.Fixit/ Fosroc/ BASF/ STP. NOTE : (i) The Treatment shall be carried out as per the manufacturers instructions and as directed by Engineer-in-charge. (ii) The plan area of floor shall be consider for payment.
M&L for roof treatment to RCC roof by applying the following method complete all as specified and directed by Engineer - in - Charge. (a) cutting and uprooting grass on roof top, removing rubbish off the premises, cleaning the roof surfaces throughly using wire brushes to remove sharp projections. cleaning joints, washing, drying and removing all dust and dirt to receive concreate padding/ plaster etc complete (b) providing 15mm thick screed bedding layer of cement mortor 1:4 with WPC finished even and smooth without using extra cement (c ) providing one coat of approved bitumenious primer @ 100mm gm per Sqm over dried plaster surface (d) laying 3mm thick APP membrane (Mineral finish) reinforced with nonwoven polyster fabric by torch application, the overlapping while torching shall be 75mm on longitudial direction and 100mm on the transverse direction Note:- (i) All joints and change in directions should be covered with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement/as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage (iii) WPC shall be got carried out by approved authorised applicator of manufacture only. The name of firm shall be got approved from GE before carrying out the work (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane (v) The guarantee of treatment shall be for minium 10 years reckoned from date of completion of whole work
S & F Fiber Glass Reinforced plastic (FRP) Door Frames of required colour of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides, MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge
S & F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge.
Taking down copper/aluminium point wiring (light,fan,socket or power)complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge.
M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -123 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -123 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 123 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 123 here in before butone light point controlled by two (2) ways switches complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S & F switch piano flush type 5/6 Amp single pole two way complete all as specified and directed by Engineer - in - Charge
S & F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F in replacement sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTPN 4 ways, 415 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F in replacment MCCB TPN 40 Amps with breaking capacity 16 KA, fixed TM and 415 volts AC Supply complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
Dismantling and refixing of ceiling fans on any size including providing fan hooks clamps complete all as specified and directed by Engineer - in - Charge.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
S & F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn and including steel dia "medium quantity" PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surface and white wash or existing colour, necessary junction box and cover including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
Supplying, laying and testing in replacement 25 Sqmmx 4 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F in replacement water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S&F in replacement compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10 WH, Crompton cat part No. LDL-10-CDL
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Note : Amount of credit of Rs 19076.00 for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
Aggarwal brothers and company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .