| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC SCO 109 SECOND FLOOR SECTOR 45 C CHANDIGARH CHANDIGARH 160047 UDYAM CH 01 0010114 | CHANDIGARH | CHANDIGARH | 160047 | ₹14.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹14.4 LRejected-Finance 1ST FLOOR SCO 3 SECTOR 41 U T CHANDIGARH | NA | NA | 160001 | ₹14.4 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Does Not Qualified Technical Bid |
Tender Value
₹14.1 L
EMD Value
₹28,190
Closing Date
2 Mar 2026, 12:00 pmClosed
Er. Gurpreet Singh Bhains
Office of the Executive Engineer, Electrical Division No. 1, Sector-9,Chandigarh.
PROVIDING CCTV CAMERA AT TRANSIT ACCOMMODATION, SECTOR-19, CHANDIGARH (IBM SCHEME NO.G1/2025/25274)
2026_CHD_90810_1
E1/TN-580
Open Tender
Electrical Works
60 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹28,190
24 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
DSR item No. 40.5.2 5/6MP IP IR Dome Camera Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc, (As per Complete Item No. 1 of the DNIT).
5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera.
DSR item No. 40.6.2 5/6MP IP IR Bullet Camera Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc,(As per Complete Item No. 2 of the DNIT).
5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.
DSR Item No.40.10.2 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below, etc,(As per Complete Item No. 3 of the DNIT).
16 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16
DSR item No.40.12.3 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.(As per Complete Item No. 4 of the DNIT).
8TB (Terabytes)
DSR item No.39.12.1 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cordshould have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required., (As per Complete Item No. 5 of the DNIT).
CopperPatchCordsoflength1m(3ft)
DSR item No.39.1.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher,(As per Complete Item No. 6 of the DNIT).
8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
DSR item No.39.3.1 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min.,(As per Complete Item No. 7 of the DNIT).
24portPoELayer2NetworkSwitchwithPoESupportof 370W or higher with each cooper port supporting 802.3at PoE+ min.
DSR item no.39.23 Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, (As per Complete Item No. 8 of the DNIT).
6U Rack
9U Rack
DSR item No.39.26 Supply and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. Etc. complete as required.
DSR item No.39.17.1Supplying,drawing,Installation,Testing and commissioningof CAT6UTPLSZH23AWGTwistedPair Cableinexisting conduit/ on surface, Category 6 Unshielded Twisted Pair, (As per Complete Item No. 10 of the DNIT).
1Runofcable
DSR item no.26.1.1 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply.,(As per Complete Item No. 11 of the DNIT).
DSR item no.42.4.2 LED Display Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, (As per Complete Item No. 12 of the DNIT).
42 inch or larger
DSR item no.39.11 Supplyof24portCat6PatchPanelloaded.Mustbeof1U heightwithclearlabelholdersandwhitelabelwiththepanel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required
DSR Item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
DSR item No.39.21.1 Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in,
6PortLIU
DSR item No.39.19.1 Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, (As per Complete Item No. 17 of the DNIT).
Single Mode 6 Core Optical fiber cable
DSR item No. 39.6.1 Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.
1G SFP Single Mode/Multi Mode
DSR item No.39.22 Supply and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 deg C to +50 deg C, Storage Temperature – 10 deg C to +50 deg C, Length -- 2meter, Type -- LC-LC Duplex etc. complete as required.
DSR item No.15.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
63 mm dia. (OD-63 mm & ID-51 mm nominal)
DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Labour charges for horizontal boring by mechanical means (hydraulic excavator)/ manual means 1 Meter below the ground level for laying of DWC Pipe including cost of 2 nos. Pit digging and refilling, disposal earth to be leveled and neatly dressed complete in all respects to entire satisfaction of the Engineer in Charge of the work.
Providing comprehensive AMC for 5 year (after expiry of defect liability period i.e. 1 year) for the various components as under including all part of hardware as well as software. Preventive Mtc. service of the equipment under AMC must be carried out once in fortnight., (As per Complete Item No. 23 of the DNIT).
2nd year
3rd year
4th year
5th year
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.99 MB
BOQ_111057.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid