Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹17.6 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹18.5 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹19.9 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FOURTH₹20.7 LRejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | FOURTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹21.2 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Sept 2021, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIR AND MAINTENANCE OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY INCLUDING STREET LIGHT AT 26 ED AND MP CAMP UNDER GE AF MARATHAHALLI BANGALORE
2021_MES_464335_2
8888/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹50,000
Yes
31 Dec 2021
25 Aug 2021
20 Sept 2021
25 Aug 2021
14 Sept 2021
1 Sept 2021
Amount
Taking down carefully copper / aluminum point wiring (Light/Fan/Socket/power) complete including fittings and fixtures such as switches , ceiling roses , pendents , regulators , sockets , light fittings etc., and making good the disturbed surfaces of walls/ floors etc complete all as specified and as directed .
Taking down submain wiring of any size /description from wooden battens/PVC conduits from walls/floors/ceiling etc., complete and making good the disturbed area complete all as specified and as directed .
Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated sheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC conduit of 20mm dia and all conduit accessories(surfaced/ concealed in walls/ceilings/floors/roof) and including provisiion of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor connected to common earth dolly in the existing mild steel terminal boxes with new 3 mm thick hylum sheet top cover for housing switches,socket outlets,fan regulators,with frame concealed in walls top cover fixed with brass screws and cup washers etc. all as specified and directed.(a) One light point / Ceiling fan / Ex fan / Call bell point controlled by oneway switch 5/6 Amps. Note:-( cutting/chases in walls making good to walls/ceilings including two coats of white colour washing/distembering to the distrubed surfaces to match the exisiting).
All as per Item No.3 above, but ,of One 2/3 pin,5/6 Amps socket outllet point on same board controlled by one,one way 5/6 Amps switch..compete all as specified and as directed.
All as per Item No.3 above, but , of One 5/6 Amps socket point controlled by Independent switch board complete all as specified and as directed .
Material and Labour for Point wiring complete with 2.5 sqmm single core PVC insulated un sheahted FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC conduit of 20mm dia and all conduit accessories (surfaced/ cincealed in walls/ceilings/ floors/roof) and including provision of 2.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor connected to common earth dolly mild steel terminal box made out of 1.60 mm thick MS sheet sunk in walls,with 3 mm thick hylem sheet top cover for housing switches,socket outlets the box concealed in walls top cover fixed with brass screws and cup washers etc, all as specified and as directed for One 15 amps socket outlet point on independent board controlled by one .one way 15 amps switch complete all as specified and as directed.
All as per Item No.3 above ,but ,of One light point controlled by two way switch.5/6 Amps complete all as specified and as directed .
All as per item No.3 above, but, of stove enamelled steel concealed conduit of 25 mm dia,meadium grade complete all steel conduit accessores/fittings, One light/ fan/Exhaust fan point controlled by one,one way switch 5/6 Amps complete all as specified and as directed.
Supply and fixing in repairs Switch piano flush button single pole one way 5 Amps, 230 V complete all as specified and as directed .
Supply and Fixing in repairs bell push flush type 5 Amps,230V complete all as specified and directed.
Supply and fixing in repairs Switch piano flush button single pole Two way 5 Amps, 230 V complete all as specified and as directed .
Supply and fixing in repairs Switch socket combination 5 pin, 5 Amps, flush type, multipurpose, universal complete all as specified and as directed .
Supply and fixing in repairs Switch socket combination 5 pin, 15 Amps, flush type universal complete all as specified and as directed .
Supply and fix in repairs ceiling rose surface PVC / polycarbonate isolated body with three terminals complete all as specified and as directed .
Supply and fixing in repairs Socket outlet 3 pin ,5 Amps, flush type complete all as specified and as directed.
Supply and fixing in repairs Socket outlet 3 pin ,15 Amps, flush type complete all as specified and as directed.
Supply and Fixing in repairs switch piano flush type, 15Amps, single pole, one way complete all as specified and as directed .
Supply and Fixing in repairs Call bell Ding Dong AC 230 Volts, complete all as specified and as directed .
Supply and fixing in repairs stepped type electronic fan regulator 5 step speed control for fans complete all as specified and as directed .
Supply and fixing in repairs LED Light fitting 1 x 20 W, Surface mounted, battern type luminaire with CRCA body, pre-coated in white & pre-wired for LED tube, bipin holders, connector block etc., including 20W -1 No LED T8 tubular lamp with in built driver with all accessories and connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings complete all as specified and as directed .
Supply and fixing in repairs LED Light fitting 2 x 20 W, Surface mounted , industrial box type luminaire with CRCA body, pre-coated in white & pre-wired for LED tube, bipin holders, connector block etc., including 20W - 2 Nos LED T8 tubular lamp with in built driver with all accessories and connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed
Supply and fixing in repairs LED Light fitting 1 x 10 W, Surface mounted, battern type luminaire with CRCA body, pre-coated in white & pre-wired for LED tube, bipin holders, connector block etc., including 8W - 1 No LED T8 tubular lamp with in built driver with all accessories and connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed
Supply and fix in repairs 100 Watts LED Highbay light with PDC housing, intrgraldriver, frame, toughened glass & IP65 protection including fixing arrangement on trusses complete all as specified and as directed .
Supply and fix in repairs Square surface mounted 18 Watts LED flat panel 1' X 1' with PDC aluminium housing and PMMA including electonic driver and LED luminaire all as specified directed
Supply and fix 36 W LED, high efficacy 2 x 2 recess LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified.
Material and Labour for Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Material and Labour for Sub main wiring complete with two runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Material and Labour for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including PVC rigid conuit of 20 mm dia alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Material and Labour for Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable size PVC rigid conduit alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note : 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Material and Labour for Sub main wiring complete with four runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two runs of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable size PVC rigid conduit alongwith accessories on surface of wall , roofs etc., all as specified and as directed. Note : 4 runs of PVC FRLS cable, two runs of earth continuity conductor cable and one run of PVC conduit shall be measured as one length/running metre.
Supply and fixing in repairs Metal clad switch socket Single pole neutral enclosure, with a two pin and earth plug and socket and one No MCB SP 20 A and fixed concealed on walls, including making good disturbed surfaces all as specified and as directed
Taking down old unserviceable MCB DB SPN and Supply and fixing sheet metal enclosure with distribution board MCB SPN 8 way, double door, 240 V, with 200 amps rated bus bar fixed to surface / concealed on walls including making good disturbed surfaces complete all as specified and as directed .
Taking down old unserviceable MCB DB TPN and Supply and fixing sheet metal enclosure with distribution board MCB TPN 4 way, double door, 240 V, with 200 amps rated bus bar fixed to surface / concealed on walls including making good disturbed surfaces complete all as specified and as directed .
Taking down old unserviceable MCCB DB TPN and Supply, fixing and connecting up complete MCCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knock outs on both sides complete all as specified and as directed .
Taking down old MCB SP and Supply and fixing MCB SP 6 - 32 Amps rating, 'B' series , 10 KA breaking capacity, 240 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCB SPN and Supply and fixing MCB SPN 6 - 32 Amps rating, 'C' series , 10 KA breaking capacity, 240 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCB DP and Supply and fixing MCB DP 32 Amps rating, 'C' series , 10 KA breaking capacity, 240 V, 50 Hz AC supply including making all connections complete all as specified .
Taking down old MCB TPN and Supply and fixing MCB TPN 63 Amps rating, 'C' series , 10 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCB and Supply and fixing MCB TPN , 3 pole 40 Amps rating , fixed thermal and magnetic setting , 16 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections with suitable lugs complete all as specified and as directed .
Taking down old MCCB and Supply and fixing MCCB , 3 pole 25 to 100 Amps rating , fixed thermal and magnetic setting 16 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCCB and Supply and fixing MCCB , 3pole 160 Amps rating , fixed thermal and magnetic setting , 25 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCCB and Supply and fixing MCCB , 3 pole 200 Amps rating , fixed thermal and magnetic setting , 36 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old MCCB and Supply and fixing MCCB , 3 pole 400 Amps rating , fixed thermal and magnetic setting , 36 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified and as directed .
Taking down old Hylam sheet and Supply and fixing 3 mm thick hylam sheet cut to size suitable for switch board housing switches , sockets and fan regulators including cadmium plated screws complete all as specified and as directed .
Material and labour for Cutting chases in brick walls for concealed conduit wiring, ,not exc 10 cm girth , pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc,and making good complete all as specified and as directed .
Material and labour for Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed .
Material and labour for Preparation of surfaces and applying one coat of external emulsion paint to RCC poles of 9 mtr height above the ground level ,including marking pole number as per existing pattern complete all as per specified and directed.
Material and labour for Preparation of surfaces of LT pole 9 metres height above the ground level and applying two coats of aluminium paint including marking the pole numbers as per existing pattern complete all as specified and as directed
Supply and fix 1.5 MFD Capacitor suitable for Ceiling fan of size 1200 mm sweep complete all as specified and as directed .
Supply and fix 2.5 MFD Capacitor suitable for Ceiling fan of size 1200 mm sweep complete all as specified and as directed .
Supply and fixing in repairs 18 watts LED PLL lamp, 4 pin type with extruded plastic body and PC diffuser complete with in built drivers after taking down old lamp complete all as specified and as directed .
Supply and fixing in repairs Retro LED T8 ,tubular lamp ,8 watts , 2 feet, with extruded aluminium body .PC diffuser and in built driver ,after taking down old lamp complete all as specified and as directed .
Supply and fix in repairsT5 LED tube light with external driver complete inlieu to T5 tube light all as specified and directed. Note: The rate deemed includes change of internal connection wiring to the extising fitting and minor spares such as side holder.
Dismantling old unserviceable terminal box and Supply and fixing moulded PVC / SMC Junction boxes out door type, weather proof, of size 240 x 130 x 95 mm to be fixed at the bottom of street light pole complete with suitable clamp , nut, bolt, washers and suitable glands ,to accommodate 01 No MCB SP 5 Amps 10 KA, with suitable connectors for incoming and outgoing connections , complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Voltmeter digital type 0-500 Volts complete all as specified and as directed .
Supply and fix in repairs Ammeter digital type 0-200 Amps complete all as specified and as directed .
Dismantling and taking down the unserviceable and defective streetlight /flood light fitting/HPSV/MH/CFL of any type make and wattage from the pole along with fixing arrangements complete up to 400 watt capacity from any height of pole or building and hangar the height
Supply and fixing in repairs LED Aviation obstruction light fitting with powder coated pressure die cast aluminium housing with polycarbonate enclosure with built -in LED chips including 302 Nos of LED luminaries complete all accessories pre wired including necessary electric connection all as specified and as directed.
Supply and fixing in repairs LED street light fitting 60 Watts, with powder coated pressure die cast aluminium housing and IP 66 protection , built-in control gear complete with anodised reflector, toughened heat resistant glass cover, LED 60 watts white colour lamp, connector block with all accessories pre wired including necessary electric connection all as specified and as directed.
Supply and fixing in repairs LED street light fitting 35 Watts, with powder coated pressure die cast aluminium housing and IP 66 protection, built-in control gear complete with anodised reflector, toughened heat resistant glass cover, LED 35 watts white colour lamp, connector block with all accessories pre wired including necessary electric connection all as specified and as directed.
Supply and fixing in repairs LED flood light 70 watt pressure die cast housing with IP65 protection with efficient high output emitter LED for better distribution with all accessories pre wired including necessary electric connection all as specified and as directed.
Suply and fixing LED decorative post top lantern fitting 20W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed.
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified and as directed
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and as directed.
Material and labour for Sand cushioning to cables with a layer of sand before and after laying the cable complete all as specified and as directed. Note :- Sand shall be measured after punned down.
Material and labour for Brick protection cover on cable with sub class 'B' bricks, across in trenches laid dry and flat adjacent to each other complete all as specified and as directed
Laying only bricks cover for cable protection, across in trenches laid dry and flat adjacent to each other complete all as specified and as directed
Material and labour for Cutting PCC / road 150mm thick for laying of LT UG cable and making good the disturbed surfaces with cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate complete all as specified and directed.
Material and labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts including taking down/up old unserviceable GI tubing complete all as specified and as directed.
Material and labour for cement concrete 1:3:6, type C1, using 20mm graded stone aggregate as in coping, bases of electric poles including necessary form work and finishing the exposed concrete surfaces of concrete even and fair complete all as specified and as directed by Engr-in-charge.
Material and labour for straight through joints (epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 25 to 35, Sqmm 3.5 core all as specified and directed.
Material and labour for straight through joints (epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 50 to 95 Sqmm, 3.5 core all as specified and directed.
Material and labour for straight through joints (epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 120 to 185 Sqmm, 3.5 core all as specified and directed.
Taking out old unserviceable UG cable of size 6 Sqmm , 4 core and supply and laying 6 sqmm, 4 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100 volts ,with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.
Taking out old unserviceable UG cable of size 10 Sqmm , 2 core and supply and laying 10 sqmm, 2 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100 volts ,with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.
Taking out old unserviceable UG cable of size 16 Sqmm , 4 core and supply and laying 16 sqmm, 4 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable of 1100volts with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.
Taking out old unserviceable UG cable of size 25 Sqmm ,4 core and supply and laying 25 sqmm, 4 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable of size 25 Sqmm 4 core 1100volts with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.
Taking out old unserviceable UG cable of size 35 Sqmm 3.5 core and supply and laying 35 sqmm, 3.5 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100volts with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed.
Taking out old unserviceable UG cable of size 50 Sqmm 3.5 core and supply and laying 50 sqmm, 3.5 core LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip wounded ,electric power cable 1100volts with stranded aluminium conductor and making connection with suitable lugs complete all as specified and directed Note;- for ser item No 78 to 83: (i) Earth work excavation , sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule..
Material and labour for mild steel section for cross arms fencing post/ bracings, supports, clamps, and back plates etc fabricated including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive two coats of Aluminium paint over a coat redoxide zinc chrome primer including dismantling of old corroded cross arms of any description from poles complete all as specified and directed.
Taking down old rusted Double stiff pendants, and material and labour double siff pendants comprising of galvanised steel or chromium plated brass bell mouth connectors 2 Nos with back plate and 2 x 1.50 metre long parallel 20 mm dia galvanised or stove enamelled screwed steel conduit withtwo check nuts for fixing tube light fitting and upto 1.5 metre long twin core 0.5 Sq mm copper concuctor flexible wire/cable etc., fixed complete on steel members with MS clamps, bolts, nuts and washers all as specified and as directed.
Suply and fix ISI 15652-2006(super seeding IS 5424 synthetic insulating mat suitable for electrical insulation of 2 Mtr X 1 Mtr X 2 mm thick including removing the existing Rubber mat complete all as per directed.
Supply and fix plates (plain or cherquered)channels, square cut or notched (ordinary and counter sunk ) forming holes, without any attachment complete all as per directed.
Supply only 10 KVAR Capacitor ( Heavy duty) 440 volts with inrush current limiting coil Note :- The quoted rates for Sl item No 86 to 90 shall be inclusive of taking down old item and refixing the new item .
Supply only 20 KVAR Capacitor (Heavy duty) 440 volts with inrush current limiting coil Note :- The quoted rates for Sl item No 86 to 90 shall be inclusive of taking down old item and refixing the new item .
Supply only 25 KVAR Capacitor ( Heavy duty) 440 volts with inrush current limiting coil Note :- The quoted rates for Sl item No 87 to 89 shall be inclusive of taking down old item and refixing the new item .
Supply only Add on Auxiliary contact Block 2 NO + 2 NC Note :- The quoted rates for Sl item No 87 to 89 shall be inclusive of taking down old item and refixing the new item .
Supply only Electronic ON delay timer 0-30 seconds, 415 Volts complete all as specified and as directed . Note :- The quoted rates for Sl item No 87 to 89 shall be inclusive of taking down old item and refixing the new item .
supply and fixing in repairs modular switch 1 way 6A,1 module complete all as specified and as directed .
supply and fixing in repairs modular switch 1 way 16A,1 module complete all as specified and as directed .
supply and fixing in repairs modular soocket 6A ,2/3 pin combination 2 module complete all as specified and as directed .
supply and fixing in repairs modular switch 1 way 6A/16A,2/3 pin combination 2 module complete all as specified and as directed .
supply and fixing in repairs modular fan regulator 120 w 2 Module complete all as specified and as directed .
supply and fix in repairs modular metal flush box 1/2 module complete all as specified and as directed .
supply and fix in repairs modular metal flush box 3 module complete all as specified and as directed .
supply and fixing in repairs modular switch socket combination16A,6 pin 3 module complete all as specified and as directed .
S & F in replacement on load changeover switch 415 V, 4 Pole, 63 Amps, open execution type all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel complete all as specified and as directed .
S & F in replacement on load changeover switch 415 V, 4 Pole, 200 Amps, with sheet enclosure all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel complete all as specified and as directed .
S & F in replacement on load changeover switch 415 V, 4 Pole, 125 Amps, with sheet enclosure all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel complete all as specified and as directed .
Material and labour for repair of LT Panel board indoor type / outdoor type repair/replacement of rusted , damged door hinges,door handles front and back side,supporting legs 40x40x6mm MS angle and necessary cutting,welding driling hole .works required at site and burnt out cables,lugs by trimming of loose wires,replacement of new cable lugs,rusted bolts & nuts. cleaning inside/outside of the panel . one coat of red oxide and two coat of enamel paint over on it including pcc foundation repair work complete all as specified and directed
Material and labour for repair/replacement of Aluminium cables lugs silver coated upto 70 sq. mm including necessary crimping tool complete all as specified and directed
Material and labour for repair/replacement of Aluminium cables lugs silver coated upto 95-120 sq. mm including necessary crimping with Crimping tool complete all as specified and directed
Supply and fixing street light panel analog time switch and contractor relay in repairs /replacement of parts with battery back up of 100 hours, having current capacity 16 A, module 240 volts with 1 changeover for controlling of security light fitting with proper connection and testing operation complete all as specified and as directed .
Supply and fixing in repairs new heating element suitable to existing model and make 1.5 KW Dual clip type/tri angle type / round type with rubber gasket suitable for geysers up to 25 Ltr capacity complete all as specified and as directed .
Supply and fixing in repairs new heating element suitable to existing model and make 2 KW Dual clip type/tri angle type / round type with rubber gasket suitable for geysers up to 50 Ltr capacity complete all as specified and as directed .
Supply and fixing in repairs new heating element suitable to solar water heater existing model and make 3 KW Dual clip type/tri angle type / round type with rubber gasket suitable for solar water heater complete all as specified and as directed .
Supply and fixing in repairs dual thermostat temperature controller (Range 30 C° to 80 C and acting at 70 C°) for geysers instant type complete all as specified and as directed .
Supply and fixing in repairs thermostat clip type (Range 30 C° to 80 C and acting at 70 C°) for geysers up to 50 Lts complete all as specified and as directed .
Supply and fixing in repairs PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser complete all as specified and as directed .
Supply only PVC connections up to 600 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser complete all as specified and as directed .
Supply only pressure release valves suitable for geyser up to 50 ltrs capacity complete all as specified and as directed .
Supply only indicating lamps green / red suitable for geysers up to 50 Ltrs complete all as specified and as directed .
Supply only 2.5 sqmm , 3 core PVC round sheathed, copper conductor (flexible) industrial cable, 1100 Volts, complete all as specified and as directed .
Material and labour in repairs and supply and fixing 15 mm dia Non return valve and GI pipe fitting complete all as specified and as directed .
Material and Labour for Repair /replacement of leakage inner stainless steel tank with base assembly for geyser 25 lts of capacity complete all as specified and as directed .
Supply and fix water heater storage type (vertical type) steel body with copper inner tank and heating element up to 2 KW capacity energy efficient electric water heater capacity 25 lts BEE 5 Star rated completed with all as acessories such as safety valve,thermostat,NRV connection pieces etc all as specifed and directed. Note Old un-serviceable geyser to be handed over to E/M store yard.
Material and labour for arresting the leakage in inner tank of solar water heater of any size / make of complete with brazing work and leak test, servicing and assembling in existing place etc complete all as specified and as directed .
Taking down old unserviceble exhaust fan and Fixing exhaust fan in position (M.D. supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and as directed .
Taking down old unserviceble ceiling fan and Hanging ceiling fan and fixing it if required (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed .
Taking down old unserviceble exhaust fan lovers for 300 / 350 / 450 mm in repair / replacement and provn of new lovers fixing in position complete all as specfied and as directed.
M & L for painting of ceiling fan complete, at site with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust all as specified.
Labour for servicing the ceiling / exhaust fan of any make including greasing /oiling /repairs and replacing the spares such as cater pin unserviceable / rusted bolts, split pins, rubber wheel, bearing, washers, bush all as specified and directed .
Supply only GM bush of ISI marked suitable for ceiling fan of size 1200 / 1400mm sweep complete all as specified and as directed .
Supply only GM bush of ISI marked suitable for Exhaust fan of size 300 / 380/450 mm sweep complete all as specified and as directed .
Supply only ball bearing suitable for ceiling fan of 1200 /1400mm sweep complete all as specified and as directed .
Supply only ball bearing suitable for Exhaust fan of 300 /380 /450 mm sweep complete all as specified and as directed .
Replacement of old unserviceable capacitors 4.0 MFD of the fan in position complete all as specified and as directed .
M & L for dismantling the defective exhaust fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
M & L for dismantling the defective Ceiling fan motor by taking out the burnt copper winding, rewinding the motor with super enamelled copper winding wire of existing gauge and weight, varnishing , including replacement of all insulation material, and other petty items required for making motor functional and checking the winding leak proof complete all as specified and directed.
Supply and fixing in repairs 15 amps plug top 3 pin backalite power sockets/ geysers complete all as specified and as directed .
Supply and fixing in repairs 5 amps plug top 3 pin backalite sockets complete all as specified and as directed .
Taking down old unserviceble electric meters in meter board and refixing in same position after repairs, replacement of parts including internal connections and made working condition complete all as specified and as directed .
Supply and fixing in repairs electronic energy meter (KWH) 5-20 Amps LCD digital type,tampered proof single phase 230 volts AC supply removing unfunctional/burnt meter and refixing with new one in position including taking down old meters and making functional all as specified and directed.Note : Old un-serviceable metersto be handed over to E/M store yard.
GKR and CO
Pacific Enterprises
RRK PROJECTS
KUZHIKKAL ENTERPRISES
ABHISHEK CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .