Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹53.1 L
EMD Value
₹1.1 L
Closing Date
3 Nov 2026, 12:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Manager Works
Construction of Parking Shed at C and D Area New FA A and B Apartments Area at HAL Bangalore
TENDER NOTICE/NCP/72/26-27::HAL/FMD/C-71/26-27
TENDER NOTICE/NCP/72/26-27
Open Tender
Works
06MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
₹1.1 L
8 Oct 2026
8 Oct 2026
3 Nov 2026
3 Nov 2026
23 Oct 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Related Document to be Uploaded to eProcurement Portal * Category: E= 75 Lakhs - Lessthan= 100Lakhs F= 50Lakhs - Lessthan 75 Lakhs G = 25Lakhs - Lessthan 50 Lakhs H = 10Lakhs - Lessthan 25 Lakhs I = 5Lakhs - Lessthan 10 Lakhs J = 2Lakhs - Lessthan 5 Lakhs K = Lessthan 2Lakhs
I.T Returns for past 03 assessment years
Annual financial turn over during the last 3 years, ending 31st March 2025
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Solvency Certificate Details
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender [Work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Demolishing cement concrete of Nominal concrete 1:3:6 or richer mix manually / by mechanical means including disposal of material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Cutting of tree roots including digging out earth removal of tree roots upto 500 girth and taking out, etc., (length of root up to 1 metre), etc., all complete as directed by Engineer-in-Charge.
Earth work in surface excavation in all kinds of Soil not exceeding 30 cm in depth but exceeding 1.50m in width as well as 10Sq m on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.50m in width or 10Sq m on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, etc., all complete as directed by Engineer-in-Charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations, etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift, etc., all complete as directed by Engineer-in-Charge.
Disposal of moorum / building rubbish / malba / similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, etc., all complete as directed by Engineer-in-Charge. Note - Item to be applicable in urban areas having directions for restricted hours for movement / plying of load carrying motor vehicle of 3.50Cu m or more.
Construction of granular sub-base by providing close graded Material With material conforming to Grade-II (size range 53mm to 0.075mm ) having CBR Value-25 conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, etc., all complete as directed by Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources), etc., all complete as directed by Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1 (1/2):3 (1 Cement: 1(1/2) coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources), etc., all complete as directed by Engineer-in-Charge.
Supply and fixing of Steel reinforcement for RCC work including straighthening , cutting, bending placing in position and binding and all complete using Thermo-Mechanically Treated bars of grade Fe-500D or more for works up to plinth level and above plinth level, etc., all complete as directed by Engineer-in-Charge.
Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in superstructure above plinth level up tp floor 5 level in all shapes and sizes in cement mortar 1: 4 Cement mortar 1:4 (1 cement : 4 coarse sand), etc., all complete as directed by Engineer-in-Charge.
Plastering for external surface in Cement mortar (1:4) plastering 20mm thick for brick / concrete surfaces including scaffolding, curing, etc., all complete as directed by Engineer-in-Charge.
Supplying, fabricating and fixing Steel work in built up tubular Hot finished welded type tubes (round, square or rectangular hollow tubes, etc.,) trusses, etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers, etc., all complete as directed by Engineer-in-Charge.
Providing and laying factory made 80mm thick chamfered edge Cement Concrete paver blocks of M-35 grade with approved colour, design and pattern in footpath, parks, lawns, drive ways or light traffic parking, etc., of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, etc., all complete as directed by Engineer-in-Charge.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per Sq m as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size [5.50 x 55]mm with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required, etc., all complete as directed by Engineer-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint for Steel and Plastered Surfaces of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture, etc., all complete as directed by Engineer-in-Charge.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Sq m over and including priming coat of exterior primer applied @ 0.90 litre/10 Sq m), etc., all complete as directed by Engineer-in-Charge.
Rupees Forty Three Lakh Eighteen Thousand Six Hundred Eleven and Eighty Seven Paise Only
Light Fittings
Supply and fixing on existing wall /ceiling/Truss, testing & commissioning of surface mounting Industrial batten suitable for 18W/20W T8 LED Tube light (four feet) Luminaries made of white powder coated CRCA sheet steel housing , operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 1 No of 18/20W T8 LED Tube with lumens output Efficacy of minimum 120 lm/W. complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten may be of STREAKNEOT8UPTO1X22WSSBSWH & TITANIAPLUS2.01213T8SSTL18WLED865SPC / Equivalent model of approved make luminaries which meets the above technical specification and as directed by Engineer-in-charge.
Supplying, installation, Testing & Commissioning of 72W Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (As per CPWD Specification). Supply, fixing & bending to shape as per site requirement of suitable dia Class B GI pipe on the wall including necessary acccessories for installation of light fixture as per E-I-C.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement including with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
6 Way SPN MCB DB
Supply, fixing, testing & commisisoning of following rating MCCB/MCB/RCBO in the existing Distribution board/powder coated enclosure as directed by Engineer-in-Charge.
20A, 10 KA C'curve DP MCB
5-32A, 10 KA C'curve SP MCB
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
3 x 2.5 sq. mm Cu Wire with Conduits
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes/truss etc., testing & commissioning of PVC insulated PVC sheathed 3Cx6sqmm Industrial flat submersible copper cable ISI Marked of 1.1kV grade confirming to IS 694 including necessary accessories and complete as per E-I-C.
Rupees One Lakh Seventy Nine Thousand Three Hundred Seventy Five and Eighty One Paise Only
Rupees Forty Four Lakh Ninety Seven Thousand Nine Hundred Eighty Seven and Sixty Nine Paise Only
Approximate Amount Put to Tender
Rupees Eight Lakh Nine Thousand Six Hundred Thirty Seven and Seventy Eight Paise Only
Rupees Fifty Three Lakh Seven Thousand Six Hundred Twenty Five and Forty Seven Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.05 MB
TN72.pdf
pdf • 0.53 MB
71TBF.pdf
pdf • 3.56 MB
71PQF.pdf
pdf • 0.20 MB
71PBF.pdf
pdf • 0.41 MB
CivilTenderdrawing.pdf
pdf • 0.30 MB
ElectricalTenderdrawing.pdf
pdf • 0.09 MB
71ECSForm.pdf
pdf • 0.48 MB
71UNDERTAKING.pdf
pdf • 0.57 MB
71CHECKLIST.pdf
pdf • 0.19 MB
71PQ.xlsm
xlsm • 0.03 MB
71PB.xlsm
xlsm • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .