Executive Engineer
Office of the Executive Engineer Mechanical and Hospital Division Anantnag
Supply, Installation, Testing and Commissioning of Fire Alarm and Fire Detection System at PHC Brakpora and PHC Sagam associated hospitals of GMC Anantnag
2023_PWDJK_240242_1
MHDA/TS/E-TENDER/35 OF 2023-23
Open Tender
Miscellaneous Works
Item Rate
45 days
PHC Sagam and Brakpora
Refer NIT
9 documents required · 9 mandatory
₹1,000
Executive Engineer M and H Division Anantnag
₹38,500
22 Feb 2024
14 Dec 2023
5 Jan 2024
15 Dec 2023
4 Jan 2024
15 Dec 2023
15 Dec 2023 - 30 Dec 2023
Amount
Supply, Installation, Testing & Commissioning of Fire Alarm and Fire Detection System at PHC Brakpora and PHC Sagam associated hospitals of GMC Anantnag
Supply and fixing of illuminated Fire exit signages. This sign may be used to Indicate all exits which can be used in the event of an emergency. It shall be accompanied: by an arrow as per IS-12349(1988) standards. Twelve each for PHC Brakpora and PHC Sagam
Providing and fixing of fire bucket stands for 6 No Buckets at designated locations. b Two each for PHC Brakpora and PHC Sagam
Providing and fixing of fire buckets of 9 Litre capacity to the stands. Twelve each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of microprocessor based 2 loop capacity networkable analogue addressable type fire alarm panel central processing unit with the following loop modles and capable of supporting of minimum 240 devices (including detectors) and minimum of 120 devices per loop and loop length upto 2 km,network communication card minimum 320 character graphic/ LCD display with touch screen or keypad and minimum 4000 event history log in the non-volatile memory (EPROM) power supply unit(230±10V, 50 Hz) 48 hrs backup with 24 volt sealed maintinance free batteries with automatic charger. the panel shall have facility to connect printer to print out the log and evacuation system (which is part of schudule under SH: PA system and shall be compatable with all accessories. The panel shall be compitable for IBMS system with open protocol BACnet/Modbus over IP complete as per specifications. One each for PHC Brakpora and PHC Sagam
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be EN54-VDS/UL-FM certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) 40 for PHC Brakpora and 50 PHC Sagam
Supply,Installation,Testing and Commissioning of Addressable analogue type Heat Detectors with combination of fixed type and rate of rise of temperature feature. Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54-VDS/UL-FM certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) EN54-VDS/UL-FM Certification. Six each for PHC Brakpora and PHC Sagam
Providing and Fitting of Response indicator for mounting on false ceiling at the entries of the cabin for indicating the operation for detectors in the above areas including Backbox. Ten each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of Addessable Manual break glass unit ( Double action) with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall be EN 54-VDS/UL-FM Certification. Two each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of Loop Powered Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements,with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be programmed from the panel. Shall be EN54-VDS/UL-FM Certification. Two each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doors etc. Shall be EN54-VDS/UL-FM Certification. One each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of Addressable Monitor Module with Inbuilt isolators for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts or Line monitoring resistors. Shall be EN54-VDS/UL-FM Certification. One each for PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of following size PVC insulated copper conductor armoured cable. The job includes providing and fitting of saddles and hinges as required. 2 C X 1.5 Sq mm armoured cable. For PHC Brakpora and PHC Sagam
Supply,Installation,Testing and Commissioning of following size PVC insulated copper conductor armoured cable. The job includes providing and fitting of saddles and hinges as required. 4 C X 1.5 Sq mm armoured cable. For PHC Brakpora and PHC Sagam
Supplying and Fixing of 25 mm PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required. For PHC Brakpora and PHC Sagam
Providing & Applying of oil based intumescent fire retardant paint suitable for Concrete/Wood/Steel .The product should be certified for upto 2 hours of fire rating and approved by local Fire Authorities.The thickness of the film shall be 550 to 700 microns. For PHC Brakpora and PHC Sagam
ASIAN MARKETING CO
BHAT SALES CORPORATION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .