| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.9 L+₹13,539.80 (0.36%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.0 L+₹23,846.40 (0.63%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.3 L+₹1.5 L (3.90%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.1 L+₹3.3 L (8.74%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
17 Aug 2021, 6:00 pmClosed
GE SATWARI
GE SATWARI
SPECIAL REPAIR TO BLDG NO P 5/10 ORs LIVING ACCN AND PROVN OF CHLORONOME PLANTS AND SEWAGE LINE FROM BLDG NO P 7/11 AND P 7/12 TO MAIN SEWAGE LINE UNDER GE SATWARI AT MIL STN JAMMU
2021_MES_459850_1
GEJM-43/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SATWARI
D Class Cat a i b i
9 documents required · 9 mandatory
₹500
GE SATWARI
₹86,000
Yes
19 Jan 2022
15 Jul 2021
19 Aug 2021
15 Jul 2021
17 Aug 2021
4 Aug 2021
Amount
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) n exc 1.5 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) exc 1.5 sqm & n. exe 4 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) ground floor to 4th floors and pavings n exc 15 cm thickness (below or above ground level ) and removing unserviceable material exc 100 mtr as specified.
Demolition of reinforced cement concrete of any discription ground to 4th floors and removing unserviceable material exc 100 mtr as specified.
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key, scrubbing down with water etc all as specified and removing unserviceable material outside the premises.
S & F pressed steel frames made of size 1.25mm thick MS steel for door with one or more rebates incl lugs, hold fast, lock strike plate etc complete of size 125 x 60mm including one coat of red oxide primer and PCC 1:3:6 as in back fill to chowkats all as spfd.
M&L 35 mm thick 2nd class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as speciied.
S&F 35mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive gauge etc without sash bar but with lock rail fitted with cut and mitered beads complete all as speciied.
S&F steel window/ Ventilator 1.25 mm thick Box type (Double Shutter) (primer coated) ERW hollow P section of size 60 mm x 25 mm single rebated comprises glazed & wire gauged skelton shutter ERW sec 50 mm x 20 mm and 1 mm thick with two Nos sash bar of T- section 20 mm x 3 mm complete welded to frame with one vertical mullion of ERW box type T- section of size 60 mm x 25 mm and 1.25 mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 four No for each window incl following fitting welded to frame shutter hold fast of 150 mm long of 12 mm x 3 mm FI made to shape 4 No, handle of Z section 20 mm x 25 mm x 100 mm long 1 No per leaf, MS tower bolt 150 mm long 2 No per leaf, Z sec 20 mm x 25 mm, 100 mm long stopper 1 No on per leaf, MS Pintal hinges of size 75 mm x 12 mm 2 No per leaf fabrication, including 10 mm Square bar grill, specing of grill 100 mm center to center and fixing arrangement as per drg No CEPZ/TD-324,325/0
S&F Mild steel works of flat iron, square bar, round bars etc. as in framed work such as grills, guard bars, gratings etc incl bending, cutting and welding as necessary of confirming to Gde Fe 310-0 all as specified.
S&F 3 mm thick sheet glass ordinary quality glazing with steel pins,oil putty to steel windows and, beads nails etc to wooden surfaces as in square exc 0.50 sqm in each pane, all as specified.
S&F in repair Galvanised mild wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S & F in repair mild steel helical/ordinary rat tail rod pattern door spring 300mm including roller and roller plate complete fixed with welding all as specified.
S&F Aluminium anodised, barrel tower bolts size 200 mm of extruded section and fixed complete all as specified. (ISI Marked)
S&F Aluminium handles, cast type, anodised Size-150mm, anodised section and fixed complete all as specified. (ISI Marked)
S&F Aluminium alloy, anodised, sliding door bolt Size- 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed cpmplete all as specified.
S&F aluminium Floor door stopper fixed complete all as specified.
S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20-22 gauge and with stainless steel brackets near to ends with stainless steel finials for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clesr opening of doors/windows. ( Including necessary fittings)
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified.
M&L Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over cement screed bed 20 mm thick CM 1:4 complete all as specified.
M&L Machine cut Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar and pigment to match the shade of the slab including rubbing and polishing laid over cement plaster, 10 mm thick CM 1:4 complete all as specified.
Material and labour 75mm thick PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in floor/ plinth protection laid in alternate bays finished even and smooth without using extra cement including joints filling by using mastic filling comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as directed
Complete Removing old brick tiles/ RCC Padding including Mud phuska and removing from site and clean the surface of roof, with cleaning with water and remove dust complete including grubbing up of trees and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove to remove all loose dirt/dust complete all as specified. Note:- All debris remove from site and throw away from out of Cantt area.
M&L for 15 mm thick plaster in cm 1:4 finished fair and even on RCC roof slab ( upto 4th storey building) incl mixing of integral water proofing compound. Note :- IWPC shall be measured and paid for separately
M&L applying roof treatment as below:-- (i) Applying a coat of bitumen primer membrane 0.4ltr/sqm by the same membrane manufacturer of density at 25 degree C’ 0.87-0.89Kg/Litre and viscosity 70-160 CPS till the surface properly impregnates and insolvent oil primer evaporates completely. (ii) Applying a coat of blown 85/25 graded bitumen confirming to IS 702 @ 1.2 Kg/sqm. (iiI) Applying Polymeric Polypropylene polymer membrane “APP” (Atactic poly propylene polymer ) modified prefabricated five layer 3mm thick not less than 3.6 Kg/Sqm with 160 grams/sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 overlap in length using butane torch with 10cm over laps which shall be thermo fused by flame (iv) Applying course of two coats of aluminium paint over the APP membrane all as specified. All joints and change in direction shall be covered with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement and curved before laying membrane.
Supply only Integral water proofing compound liquid.
M&L for PCC 1:2:4 type B 1 using (20 mm graded aggregate) as in blocks for hold fasts, benching, coping apex stones, bed plates and the like including weathering slightly rounded or chamfered angles and throating all as specified. Note: Form work required for these items included in the unit rate of this item.
Dismantling of CGI/AC or plain or corrugated steel sheeting, any gauge, thickness, including nanital or similar pattern roof covering.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
Pre- painted galvatume aluminum zinc coating (AZ-150 Micron) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates, or flat sections) including distance pieces, cleats etcFe 410 -W (GdeE- 250) qualityA complete all as specified.
M&L Mild steel screw bolt (machine made) dia 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5cm and n exc 30cm long complete all as specified.
M&L RCC 1:2:4 Type B1, ( 20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, Chajja, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified.
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified.
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
M&L for rendering 15 mm thick in CM 1:4 on fair face of brick work/ stone wall surfaces finished even and smooth without using extra cement all as specified. ( incl all necessary scaffolding, lifting arrangement for three story building on external surfaces).
M&L for rendering 05mm thick in CM (1:3) as in ceiling finished even and smooth w/o using extra cement.
M&L for repairing of concrete surfaces such as correction of chajjas, upward facia, downward facias, ceiling and similar items with plain cement concret 1:2:4 type B-0 or rendering 10mm thick in CM 1:3 includind dubbing coat without using extra cement finished even and fair including necessory formwork and scaffolding complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth complete all as specified
M&L for applying two coat of synthetic enamel paint on new wooden surfaces of any description over a coat of pink primer having width/girth exceeding 10 cm including preparation and necessary filling by chalk putty as and where requered to make surface even and smooth complete all as specified.
M&L for preparation of new plastered surfaces of walls, & applying two coats of oil bound distemper over two coat of wall care putty of 1 to 2 mm thick and one coat of primer complete all as specified.
M&L for preparation of old plastered surfaces of walls, & applying two coats of oil bound distemper over two coat of wall care putty of 1 to 2 mm thick and one coat of primer complete all as specified.
M&L for preparation of old/new decorative plastered/concreat surface of wall, chajja, facia, face of columns, beam ect by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots & rubbing with sand paper and applying one coat of weather proof exterior emulsion (APEX) with necessary scaffoding up to 4th storey, including necessary filling of wall care putty on uneven surface as and where required all as specified.
M&L for preparation of new plastered/concrete surfaces of walls, (up to 4th sorey with necessary scaffolding) and applying two coat of cement based paint over one coat of primer complete all as per specified and directed by Engr-in-charge.
M&L for preparation of old decorated plastered /concrete/ brick surfaces of walls and applying one coat of cement based paint on old decorated surfaces including preparation.
M&L for preparation of new wall surface, Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, oil, greasy spots & rubbing with sand paper and and applying two coat of white wash on ceiling.
M & L for preparation of old wall surface , Pillars, cornices etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, oil, greasy spots & rubbing with sand paper and and applying one coat of white wash on ceiling.
M&L for ATT Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors
M&L for repairing of concrete surfaces such as chajjas, upward facia, downward facias, ceiling and similar items with plain cement concret 1:2:4 type B-0 or rendering 10mm thick in CM 1:3 includind dubbing coat without using extra cement finished even and fair including necessory formwork and scaffolding complete all as specified and directed.(Up to fourth storey bldg)
M&L for applying one coat of synthetic enamel paint on old painted steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth and apply putty and primer where requred complete all as specified
Supply and fixing in repair 4 mm dia plain galvanised wire class 3 , in detached work such as mosquito nets including fixing arrangement ( fixing with 12 mm bolt through dril in wall with plates which will be use as washer at both side of wall) to wall both side complete all as specified as directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10Sqm on plan and n.exc 1.5m in depth and getting out any type of soil etc complete and all as specified and as directed
Excavation in trenches, n.exc 1.5m wide and exc 1.5m to 3.0 mm in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10Sqm on plan and n.exc 1.5m in depth and getting out any type of soil etc complete and all as specified and as directed
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified.
Demolition and breaking up drain pipes 150/200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified.
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm etc complete all as specified.
Removing excavated material in exc 250m but n exc 500 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified etc complete all as specified.
M&L HDPE Double wall corrugated pipe with 150mm (S4 ) with integral socket and necessary fittings, laid in trenches jointed complete all as specified
M&L Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation for manhole etc, complete all as specified.
M&L Brickwork with subclass ‘B’ bricks, old size brick, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe ( Internal dia 150 to 200mm ) and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required.
M&L Providing, cement concrete 1:2:4 Type-B0 ( 12.50mm graded aggregate) in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L Providing precast cement concrete Type B1, 1:2:4 ( 20 mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
S&F angle iron, flat, tee, for manhole cover frame including all necessary drilling, bolting or welding etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L Septic tanks, exc, in ordinary soil, foundation In PCC 1:2:4, brick work in CM 1:4, RCC Slab covers M-25 including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 150 users. ( Drg No.- CEPZ-TD /13/13 Sheet 1/5 to 5/5 )
M&L Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in 1:4 CM, RCC cover slab in M-25 Filling with brick bats, complete of size 2.4 M dia X 3.0 M deep. ( Drg No.- CEPZ-TD /13/13 Sheet 1/5 to 5/5 )
Cleaning of sewage manhole (any size) completely by emptying liquid/solid (Sewage) , including cleaning of inlets, outlets and getting out manualy, and removing and disposing the same at a place meant for disposal of foul material out side the cantonment area all as directed.
Taking down carefully aluminium conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
Taking down of Unsv MCB DB SPN/TPN along with MCB's
M&L for complete point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , terminated into modular galvanised suitable size sunken boxes including white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc complete all as specified and as directed for the following :- (a) One light/fan point controlled by one, one way switch 6 Amp complete
(b) One 3 pin socket outlet 6 amp independent
(c) One 3 pin socket outlet 6 amp same board
Ditto all as per Srl item No 72 above but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
M&L modular type switch, one way 6 Amps , 1 module complete all as specified and directed.
M&L modular type socket 5 pin, 6 Amps combined 2 module complete all as specified and directed.
M&L modular type switch, one way 16 Amps, 1 module complete all as specified and directed.
M&L modular type socket 5 pin, 6 A/16 Amps combined 2 module complete all as specified and directed.
M&L modular type fan regulator step down 120 Watt, 2 module complete all as specified and directed.
Supply and fixing ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
Supply and fixing LED tubelight fitting 18-20 W LED, 230V, batten type High quality aluminium extruded with decorative end caps complete in all respect . Make : Jaquar Model Glaze LED Batten cat part no LGLZO1X020XC or equivalent in Wipro , Havells .
Supply and fixing complete energy saving new generation 10W LED IP65 bulk head luminary with opal diffuser complete all as specified and directed. Make : Crompton Cat part LBHP-10-CDL or equivelant in Havells, Wipro
S & F of lamp holder,PVC /Polycarbonate type with back plate for batten fitting .
S & F LED lamp suitable for B22 holder of capacity 10 Watt. Make: Havells model ADORE Ball lamp cat part no LHLDERUEMD8X010 equivalent in crompton or bajaj
S&F Distribution Board (SPN) double door 12 Way and should be IP 43 protected with Copper Bus bar,Earth Bar ,neutral Bar Door Earthing. Makes: IndoAsian Optipro Cat Part No 811807 or equivalent in Havells/ Seimens/C & S Electric
S&F MCB SPN complete 32 Amp with rupturing capacity 10 KA 'C' series, complete all as specified and directed. Make:- IndoAsian Optipro Cat Part No 811151 or equivalent in Havells/ Seimens/C & S Electric
S&F MCB single pole 6 to 32 Amp with rupturing capacity 10 KA 'C' series,ISI Marked complete all as specified and directed. Make:- IndoAsian Optipro or equivalent in Havells/ Seimens/C & S Electric
S&F sub main wiring with single core cable 2x 6 sq mm FRLSH insulated Unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x6 Sq mm FRLSH insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including chesing, cutting & making good to match with the existing surface complete all as specified and directed.
M&L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6.3mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.
S &F Distribution Board (TP&N) ,double door suitable for TP MCCB 100 Amps as incomer and out going MCBs 4 ways including MCCB 100A 3 pole 16KA and should be IP 43 protected with Copper insulated BusBar assembly ,Isolated Neutral Bar ,Earthing bar ,door earthing Note:- MCB shall be measured & paid seperately. MCCB,MCB & DB shall have the same make.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty electric cable with XLPE insulated screened PVC bedded aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of size 16 Sqmm x 4 core.
Supply and fixing of Ceiling Fan Complete with Blades downrods (as per site requirement) electronic regulator and acessories 230 V 1200 mm Sweep minimum air delivery 210 (CFM) with service value 6.00 BEE 5 Star rated with brushless direct current Motor (BLDC)
Supply and spreading sand dry, clean in trenches as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as specified
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified
M&L for tube light grade galvanized with all fitting and fixed complete to wall and ceiling or laid in floors of size 40 mm dia
Taking down of fan ceiling cable and dismantling blades and depositing Fan and blades in safe custody of user or MES store yard of AGE E/M.
Supply, install, testing and commissioning of chemical dosing system plunger type suitable to inject solution upto 25 LPH @ 10 kg/cm2 working pressure dosing pump coupled with 3 phase electric motor of 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 Ltrs capacity complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with chemical grade PVC NRV with 3 Phase DOL starter for dosing pump made of power coated MS fabricated box comprising of LED indicators,digital volt meter, Amp meter, Single phase preventer, high voltage low voltage protection complete all as specified. Make : Model No. SSAPS/CDSPT/25 of M/s Sathya Sai Aqua Pura Services or equivalent in ION EXCHANGE/ MAIC INDIA / JESCO Note: Rate includes necessary electric and water connection from existing sources incl necessary Civil wk as required to install the dosing plant.
S&F unplasticised PVC pipe of pressure rating 10 Kgf/cm Squre fixed complete to walls ceilings or in floors along woth NRV, stop valve etc of size 15mm bore as directed by Engr-in-charge.
Supply and laying testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm, 3 core 1100 volts grade complete all as directed by Engr-in-Charge
Cutting of existing pipe of any size for alterations or additions as directed by Engr-in-charge.
M/S VED PAUL MAHAJAN
Azurite Engineering
M/S Shesh Paul Gupta
CELMAC REGD
M/S RAJ ENGINEERS
Jatinder Singh
MOHINDRA ENTERPRISES
M/S PARAMJEET SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .