Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC VILL PO POOH DISTT KINNAUR 172111 HP | KINNAUR | HIMACHAL PRADESH | 172111 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹34.6 L+₹4.5 L (15.0%)Rejected-Finance HOUSE NO 49 SECTOR 28 FARIDABAD 121008 HR | FARIDABAD | FARIDABAD | HARYANA | 121008 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.3 L+₹6.2 L (20.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹41.7 L+₹11.6 L (38.7%)Rejected-Finance H NO 816 NEAR GANDHI CHOWK KALKA 133302 HARYANA | KALKA | PANCHKULA | HARYANA | 133302 | L4 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | A P ENTERPRISES L3 | M/S Shamsher Negi Dewa L1 | m/s jupiter builders L4 | M/S Behl Sons L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets complete all as specified and directed by Engr in Charge. | 116.74 | Sqm | 40 ₹4,669.6 | 38 ₹4,436.12 | 38 ₹4,436.12 | 8 ₹933.92 Lowest |
| 2.00 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work complete all as specified and directed by Engr in Charge. | 1 | Cum | 500 ₹500 | 1,000 ₹1,000 | 480 ₹480 Lowest | 1,000 ₹1,000 |
| 3.00 | -Ditto- all as per item above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section. | 300 | RM | 10 ₹3,000 | 20 ₹6,000 | 12 ₹3,600 | 3 ₹900 Lowest |
| 4.00 | M & L for second class hardwood clean sawn scantlings as in timber framed and fixed complete all as specified and directed complete all as specified and directed by Engr in Charge. | 0.6 | Cum | 80,000 ₹48,000 Lowest | 92,500 ₹55,500 | 90,000 ₹54,000 | 80,000 ₹48,000 Lowest |
| 5.00 | Ditto all as above but except Timber. | 0.4 | Cum | 20,000 ₹8,000 | 9,950 ₹3,980 Lowest | 19,500 ₹7,800 | 18,000 ₹7,200 |
| 6.00 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed by Engr in Charge. | 240 | RM | 200 ₹48,000 | 84 ₹20,160 | 160 ₹38,400 | 45 ₹10,800 Lowest |
| 7.00 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed by Engr in Charge. | 60 | RM | 280 ₹16,800 | 200 ₹12,000 | 295 ₹17,700 | 120 ₹7,200 Lowest |
| 8.00 | M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed by Engr in Charge. | 116.74 | Sqm | 1,000 ₹1,16,740 | 850 ₹99,229 | 1,500 ₹1,75,110 | 720 ₹84,052.8 Lowest |
| 9.00 | M & L for preparation of wood and wood based materials, new or old surfaces any description not otherwise described and exc 10cm width or girth and applying two coats of creosote oil complete all as specified and directed by Engr in Charge. | 2 | Sqm | 80 ₹160 | 33 ₹66 Lowest | 85 ₹170 | 90 ₹180 |
| 10.00 | M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr in Charge. | 181.6 | Sqm | 80 ₹14,528 Lowest | 165 ₹29,964 | 85 ₹15,436 | 90 ₹16,344 |
Tender Value
₹37.1 L
EMD Value
₹74,300
Closing Date
22 Nov 2025, 6:00 pmClosed
GE 863 EWS
GE 863 EWS, c/o 56 APO
GE/863/EWS-T-53 OF 2025-26 SPL REPAIR TO BLDG NO T 01 AND T 02 MOR AND ATGM OF 19 BIHAR AND SPL REPAIR/REPLACEMENT OF OVERHEAD LINE INTO UNDERGROUND LT CABLE OF FSC AT POOH UNDER GE 863 EWS
2025_MES_732784_2
GE/863/EWS-T-53 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
POOH
As per tender documents
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹74,300
Yes
5 Jan 2026
10 Nov 2025
24 Nov 2025
10 Nov 2025
22 Nov 2025
17 Nov 2025
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets complete all as specified and directed by Engr in Charge.
Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work complete all as specified and directed by Engr in Charge.
-Ditto- all as per item above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section.
M & L for second class hardwood clean sawn scantlings as in timber framed and fixed complete all as specified and directed complete all as specified and directed by Engr in Charge.
Ditto all as above but except Timber.
M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed by Engr in Charge.
M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed by Engr in Charge.
M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed by Engr in Charge.
M & L for preparation of wood and wood based materials, new or old surfaces any description not otherwise described and exc 10cm width or girth and applying two coats of creosote oil complete all as specified and directed by Engr in Charge.
M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr in Charge.
Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr in Charge.
Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr in Charge.
S & F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr in Charge.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood plain, framed panelled shutters (any numbers of panels0 with panels of timber flat on both sides (feather edged) or od veneered particle board of medium density , wood particle board with commercial face veneers and fitted to chaukhats complete all as specified and directed by Engr in Charge.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed by Engr in Charge.
S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed by Engr in Charge.
S & F clamps, hold fast,hook washer & similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engr in Charge.
M & L for providing cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in hold fast blocks complete all as specified and directed by Engr in Charge.
S & F 125mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engr in Charge.
-Ditto- all as per item above but 75mm long.
S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engr in Charge.
S & F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr in Charge.
S & F 125mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr in Charge.
S & F 150mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr in Charge.
S & F 125mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr in Charge.
S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed by Engr in Charge.
M & L sheet glass, 4mm thick ordinary quality and glazing with oil putty or beadings in square not exc 0.5 sqm in each pane complete all as specified and directed by Engr in Charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engr in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr in Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr in Charge.
M &L 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate finishing surface even and smooth wuthout using extra cement a in plinth protection complete all as specified and directed by Engr in Charge.
M &L 75mm thick cement concrete type D2 1:4:8 in sub base floor complete all as specified and directed by Engr in Charge.
M &L chequered cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry over 20mm thick scrred bed in cement mortar 1 :4 as in floors with grey cement and pigment complete all as specified and directed by Engr in Charge.
M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr in Charge.
M & L for glazed ceramic coloured tiles in vertical surface 300 x 200 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engr in Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr in Charge.
M &L for pre-cast cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in block masonry with solid blocks, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engr in Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr in Charge.
M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and directed by Engr in Charge.
M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 and finished even and smooth (without using extra cement) complete all as specified and directed by Engr in Charge.
M & L for complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coats of distemper oil emulsion over a coat of primer on wall complete all as specified and directed by Engr in Charge.
M & L for preparing newly plastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engr in Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed by Engr-in-Charge
Taking down unserviceable submain wiring and service cable alongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site complete all as specified and directed by Engr in Charge.
Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge.
Matrial & Labour for point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded , 1100 volt grade copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceiling including provision PCV Box on top for fixing switches sockets etc. all as specified for one light point / fan / Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 46 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge.
All as per Srl item No 46 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with cable 1.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.
All as per Srl item No 46 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge.
Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge.
Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge,
Supply and fixing of Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge,
M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge.
Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr in Charge. Make : Anchor/leader/havells
Supply and fix in replacement LED Batten 20W , 4 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed by Engr in Charge. Make- Havells / Philips / Crompton
Supply and fixing 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engr-in-Charge. Make: Havells
Supply & Fixing LED Bldg security light fitting 30 Watt with best in class design & robust heat sink along with class leading IP 65,IK & surge protection for long lasting performance connected with copper conductor cable of suitable size. Make Havells/Bajaj/Crompton complete all as specified and directed by Engr in Charge. Note:- Sutable size bore of Security light suitable for GI Bracket measured and paid seperately in respective item.
Material and Labour street light bracket made out from GI Pipe 32 / 40 mm bore light grade 1.20 meter long bent to required shape and fixing to poles etc including fixing of clamps, nuts, bolts etc as specified and directed by Engr-in-Charge.
Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 08 way 240 volt complete all as specified and directed by Engineer-in-Charge .
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr in Charge. (i) SP 5 to 32 Amp
(ii) SPN 63 AMP
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed by Engr in Charge.
Supply and fixing House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. Grade), with two nos of suitable size of clamp,nuts, bolts and wahers etc fixed to GI sheet roof complete all as specified and directed by Engr in Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions complete all as specified and directed by Engr in Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engr in Charge.
Supply, laying and Testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core all as specified and directed by Engr-in-Charge
All as per item No. 67 above but of size 10 Sqmm 2 core all as specified and directed by Engr-in-Charge.
All as per item No. 67 above but of size 16 Sqmm 4 core all as specified and directed by Engr-in-Charge.
All as per item No. 67 above but of size 16 Sqmm 2 core all as specified and directed by Engr-in-Charge.
All as per item No. 67 above but of size 50 Sqmm 3.5 core all as specified and directed by Engr-in-Charge
Dismantling cross arms of MS channel or angle sections etc complete all as specified and directed by Engr-in-Charge.
Dismantling insulators any type and size complete all as specified and directed by Engr-in-Charge.
Dismantling of ACSR conductors complete all as specified and directed by Engr-in-Charge.
Supply and fix junction box made out of high quality thermoplastic polycarbonate enclosure with IP 65 degree protection, weather proof, corrosion proof, dust proof, insulated and shock proof, fire retardant non toxic material with internally embedded gasket with 0.5 to 6 Amp MCB and 4 nos terminal and overall size of box fixed to LT Pole with suitable size of clamp, nut, bolt & washer complete all as specified and directed by Engr-in Charge Make Hensel or equivalent make of sintex/universal complete all as specified and directed by Engr in Charge.
Supply and fix cable 3 core PVC cable of 1.5 sqmm ISI mark from street light to junction box complete all as specified and directed by Engr-in-charge
Supply and Fix in replacement of u/s street light with LED energy saving and enviromental friendly long life LED Street Light 60Watt made up of pressure die cast aluminium housing with high effciency LED as light source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK07 with street light bracket of 32/40 mm medium grade GI Pipe length not less than 1.5 meter bend to shape with two no of clamp incl nuts, bolts and washers complete all as specified and directed by Engr-in-Charge
M & L for earthing complete with galvanised steel, earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 4.5mtr below ground level) with top edge of the plate not less than 3.75 mtr below normalground level connected to galvanised earth trip as earthing lead (32x6mm) by means of bolts nuts check nuts and washer of galvanised iron/steel connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate wetering pipe 20mm dia GI medium grade GI sheet 0.63mm thick funnel , wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade upto 7.5 mtr from electrode and engraving of earth marking on near by structure/painting of earth results etc, complete all as specified indicated on electrical plate No-1 SSR Part_I 2009 Page No-479 and as directed including testing on completion complete all as specified and directed by Engr in Charge. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified ,indicated on electrical plate No 5 and as directed incl testing on completion complete all as specified and directed by Engr in Charge. NOTE: ( i ) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of size 40 mm with suitable size clamp, nut bolt washer etc complete all as specified and directed by Engr in Charge.
M & L for DWC High density polyethylene pipes (HDPE) of pressure rating PN-10 for mechnical protection of UG Cable fixed complete to walls , ceilings, hard standing, floor etc of size 40 mm bore complete all as specified and directed by Engr in Charge.
M & L for DWC High density polyethylene pipes (HDPE) of pressure rating PN-10 for mechnical protection of UG Cable layed into hard standing, road etc fixed complete size 63 mm bore complete all as specified and directed by Engr in Charge.
M & L for DWC High density polyethylene pipes (HDPE) of pressure rating PN-10 for mechnical protection of UG Cable layed into hard standing, road etc fixed complete size 75 mm bore complete all as specified and directed by Engr in Charge.
Supply and fixing of sheet metal enclosure double door for DBs Triple pole and neutral for 4 way 240 volt complete all as specified and direct by Engineer-in-Charge .
Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 8 way 240 volt complete all as specified and direct by Engineer-in-Charge .
Supply and fixing MCB TPN 40 amps 415 V complete all as specified and direct by Engineer-in-Charge .
Supply and fixing MCB TPN 63 amps 415 V complete all as specified and direct by Engineer-in-Charge .
Supply and fixing MCB SPN 63 amps 415 V complete all as specified and direct by Engineer-in-Charge .
Supply and fixing MCB SPN 40 amps 415 V complete all as specified and direct by Engineer-in-Charge .
Supply and fixing MCB SPN 32 amps 230V complete all as specified and direct by Engineer-in-Charge .
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc all as directed by Engr-in-charge.
M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable all as specified and directed
Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed by Engr in Charge. Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge.
Schedule of Credit
M/S Behl Sons (BID ID -3479836)
A P ENTERPRISES (BID ID -3479515)
m/s jupiter builders (BID ID -3485582)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.48 MB
Tender Documents
Tender Documents • 2.23 MB
BOQ
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .